HomeMy WebLinkAboutFt. Pierce, FL - Drawings<<w=175; h=175; n=BLANK - SIG; a=11>> SITE NAME: SITE NUMBER: ATC PROJECT NUMBER: SITE ADDRESS: FORT PIERCE - OMNIAMERICA 75123 OAA753661_C6_06 14101 W ANGLE RD FORT PIERCE, FL 34945 THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 G-001 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 COVER 0 FIRST ISSUE BJK 01/30/20 0 COMPLIANCE CODE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. ANSI/TIA/EIA: STRUCTURAL STANDARDS (222-G EDITION) 2. INTERNATIONAL BUILDING CODE (2015 IBC) [FOR SPECIAL INSPECTION REQUIREMENTS ONLY] 3. 6TH EDITION FLORIDA BUILDING CODE (2017) PROJECT LOCATION GEOGRAPHIC COORDINATES LATITUDE: 27.46630278 LONGITUDE: -80.46502222 SHEET SHEET TITLE REV. G-002 IBC GENERAL NOTES 0 G-003 SPECIAL INSPECTION CHECKLIST 0 G-004 REBAR LIST 0 C-101 DETAILED SITE PLAN 0 S-201 MODIFICATION PROFILE 0 S-501 FOUNDATION INSTALLATION DETAILS 0 S-502 FOUNDATION INSTALLATION DETAILS (CONT'D)0 S-601 GUY WIRE TENSION CHART 0 S-602 GUY WIRE RETENSIONING AND STANDARD SAFETY WIRE DETAILS 0 Z-501 GUY ANCHOR FENCE & GROUNDING DETAILS 0 PROJECT DESCRIPTION THE MODIFICATIONS PRESENTED ON THESE DRAWINGS ARE BASED ON THE RECOMMENDATIONS OUTLINED IN THE STRUCTURAL ANALYSIS COMPLETED UNDER ENGINEERING PROJECT NUMBER OAA753661_C3_02 DATED 01/13/20. SATISFACTORY COMPLETION OF THE WORK INDICATED ON THESE DRAWINGS WILL RESULT IN THE STRUCTURE MEETING THE REQUIREMENTS OF THE SPECIFICATIONS UNDER WHICH THE STRUCTURAL WAS COMPLETED. PROJECT TEAM TOWER OWNER AMERICAN TOWER 10 PRESIDENTAL WAY WOBURN, MA 01801 ENGINEERED BY ATC TOWER SERVICES 3500 REGENCY PARKWAY, SUITE 100 CARY, NC 27518 CARRIER INFORMATION CARRIER:HC2 HOLDINGS, INC. CARRIER SITE NAME:WEST PALM BEACH,FL 2 CARRIER SITE NUMBER: 1031097-182904-WDOX-LD VICINITY MAP LOCATION MAP SITE LOCATION 440 FT GUYED TOWER MODIFICATIONS WEST ANGLE RD CO D Y L N <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 G-002 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 IBC GENERAL NOTES 0 FIRST ISSUE BJK 01/30/20 0 MAXIMUM ALLOWABLE ANGLE CLIP 1.5 X L MAX. L AREA OF ANGLE TO BE CLIPPED GENERAL 1. ALL WORK TO BE COMPLETED PER APPLICABLE LOCAL, STATE, FEDERAL CODES AND ORDINANCES AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS FOR WIRELESS TOWER SITES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND ABIDING BY ALL REQUIRED PERMITS. 2. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS EXPERIENCED IN TOWER AND FOUNDATION CONSTRUCTION. 3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY OF ANY INSTALLATION INTERFERENCES. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS. DETAILS NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL FOLLOW SIMILAR DETAILS FOR THIS JOB. 4. ANY SUBSTITUTIONS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES AND SPECIFICATIONS, AND SHOULD BE SIMILAR TO THOSE SHOWN. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 5. ANY MANUFACTURED DESIGN ELEMENTS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES AND SPECIFICATIONS AND SHOULD BE SIMILAR TO THOSE SHOWN. THESE DESIGN ELEMENTS MUST BE STAMPED BY AN ENGINEER PROFESSIONALLY REGISTERED IN THE STATE OF THE PROJECT, AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION. 6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES AND OSHA SAFETY REGULATIONS. 7. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL MISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS, ETC. NECESSARY, PER ANSI/TIA-322 AND ANSI/ASSE A10.48, TO PROVIDE A COMPLETE AND STABLE STRUCTURE AS SHOWN ON THESE DRAWINGS. 8. CONTRACTOR'S PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESS TO, ANY EXISTING OPERATIONAL AND SAFETY EQUIPMENT. STRUCTURAL STEEL 1. ALL DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE AISC SPECIFICATIONS, LATEST EDITION. 2. ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION PER ASTM A123. EXPOSED STEEL HARDWARE AND ANCHOR BOLTS SHALL BE GALVANIZED PER ASTM A153 OR B695. 3. ALL U-BOLTS SHALL BE ASTM A36 OR EQUIVALENT, WITH LOCKING DEVICE, UNLESS NOTED OTHERWISE. 4. FIELD CUT EDGES, EXCEPT DRILLED HOLES, SHALL BE GROUND SMOOTH. 5. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES & GROUND SURFACES WHERE EXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIRED WITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURERS RECOMMENDATIONS. 6. ALL STRUCTURAL STEEL EMBEDDED IN THE CONCRETE SHALL BE APPLIED WITH (2) BRUSHED COATS OF POLYGUARD CA-14 MASTIC OR EQUIVALENT. REFER TO THE MANUFACTURER SPECIFICATIONS FOR SURFACE PREPARATION AND APPLICATION. APPLICATION OF POLYGUARD 400 WRAP IS NOT ESSENTIAL. 7. CONTRACTOR SHALL PERFORM WORK ON ONLY ONE (1) TOWER FACE AND REPLACE/REINFORCE ONE (1) BOLT/MEMBER AT A TIME. 8. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BE STANDARD HOLES, AS DEFINED BY AISC, UNLESS NOTED OTHERWISE. PAINT 1. AS REQUIRED, CLEAN AND PAINT PROPOSED STEEL ACCORDING TO FAA ADVISORY CIRCULAR AC 70/7460-1L. WELDING 1. ALL WELDING TO BE PERFORMED BY AWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE AWS WELDING CODE D1.1. 2. ALL WELDS SHALL BE INSPECTED VISUALLY. IF DIRECTED BY ENGINEER OF RECORD, 25% OF WELDS SHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE (100% IF REJECTABLE DEFECTS ARE FOUND) TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. REPAIR ALL WELDS AS NECESSARY. 3. INSPECTION SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR. 4. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER AND/OR BASE METAL, PER AWS D1.1, UNLESS NOTED OTHERWISE. 5. IN CASES WHERE BASE METAL GRADE IS UNKNOWN, ALL WELDING ON LATTICE TOWERS SHALL BE DONE WITH E70XX ELECTRODES; ALL WELDING ON POLE STRUCTURES SHALL BE DONE WITH E80XX ELECTRODES, UNLESS NOTED OTHERWISE. 6. PRIOR TO FIELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING 1/2" BEYOND ALL FIELD WELD SURFACES. AFTER WELD AND WELD INSPECTION IS COMPLETE, REPAIR ALL GROUND AND WELDED SURFACES WITH ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURERS RECOMMENDATIONS. BOLT TIGHTENING PROCEDURE 1. STRUCTURAL CONNECTIONS TO BE ASSEMBLED AND INSPECTED IN ACCORDANCE WITH RCSC SPECIFICATIONS. 2. FLANGE BOLTS SHALL BE INSTALLED AND TIGHTENED USING DIRECT TENSION INDICATING (DTI) SQUIRTER WASHERS. DTI SQUIRTER WASHERS ARE TO BE INSTALLED AND ORIENTED / TIGHTENED PER MANUFACTURER SPECIFICATIONS TO ACHIEVE DESIRED LEVEL OF BOLT PRE-TENSION. 3. IN LIEU OF USING DTI SQUIRTER WASHERS, FLANGE BOLTS MAY BE TIGHTENED USING AISC / RCSC "TURN-OF-THE-NUT" METHOD, PENDING APPROVAL BY THE ENGINEER OF RECORD (EOR). TIGHTEN FLANGE BOLTS USING THE CHART BELOW: BOLT LENGTHS UP TO AND INCLUDING FOUR DIAMETERS BOLT LENGTHS OVER FOUR DIAMETERS BUT NOT EXCEEDING EIGHT DIAMETERS 4. SPLICE BOLTS SUBJECT TO DIRECT TENSION SHALL BE INSTALLED AND TIGHTENED AS PER SECTION 8.2.1 OF THE AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS", LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION. THE INSTALLATION PROCEDURE IS PARAPHRASED AS FOLLOWS: FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONE OF THE METHODS DESCRIBED IN SUBSECTION 8.2.1 THROUGH 8.2.4. 8.2.1 TURN-OF-NUT PRETENSIONING BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT TO A SNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1, UNTIL ALL THE BOLTS ARE SIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED. FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BE TIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED ABOVE. DURING THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOT TURNED BY THE WRENCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY. 5. ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHT TO A SNUG TIGHT CONDITION AS DEFINED IN SECTION 8.1 OF THE SPECIFICATION. ALL BOLT HOLES SHALL BE ALIGNED TO PERMIT INSERTION OF THE BOLTS WITHOUT UNDUE DAMAGE TO THE THREADS. BOLTS SHALL BE PLACED IN ALL HOLES WITH WASHERS POSITIONED AS REQUIRED AND NUTS THREADED TO COMPLETE THE ASSEMBLY. COMPACTING THE JOINT TO THE SNUG-TIGHT CONDITION SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE JOINT. THE SNUG-TIGHTENED CONDITION IS THE TIGHTNESS THAT IS ATTAINED WITH A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH TO BRING THE CONNECTED PLIES INTO FIRM CONTACT. APPLICABLE CODES AND STANDARDS 1. ANSI/TIA: STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES, 222-G EDITION. 2. 2015 INTERNATIONAL BUILDING CODE (FOR SPECIAL INSPECTION REQUIREMENTS ONLY). 3. 6TH EDITION FLORIDA BUILDING CODE (2017) 4. ACI 318: AMERICAN CONCRETE INSTITUTE, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. REFERENCE LATEST APPROPRIATE EDITION TO MATCH LOCAL AND/OR INTERNATIONAL BUILDING CODE(S) LISTED ABOVE. 5. CRSI: CONCRETE REINFORCING STEEL INSTITUTE, MANUAL OF STANDARD PRACTICE, LATEST EDITION. 6. AISC: AMERICAN INSTITUTE OF STEEL CONSTRUCTION, MANUAL OF STEEL CONSTRUCTION, LATEST EDITION. 7. AWS: AMERICAN WELDING SOCIETY D1.1, STRUCTURAL WELDING CODE, LATEST EDITION. SPECIAL INSPECTION 1. A QUALIFIED INDEPENDENT TESTING LABORATORY, EMPLOYED BY THE OWNER, SHALL PERFORM INSPECTION AND TESTING IN ACCORDANCE WITH IBC 2015, SECTION 1704 AS REQUIRED BY PROJECT SPECIFICATIONS FOR THE FOLLOWING CONSTRUCTION WORK: a) STRUCTURAL WELDING (CONTINUOUS INSPECTION OF FIELD WELD ONLY) b) HIGH STRENGTH BOLTS (PERIODIC INSPECTION OF A325 EXTENSION FLANGE BOLTS TO BE TIGHTENED PER "TURN-OF-THE-NUT" METHOD) 2. THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS TO THE BUILDING DEPARTMENT, THE ENGINEER OF RECORD, AND THE OWNER IN ACCORDANCE WITH IBC 2015, SECTION 1704, UNLESS THE FABRICATOR IS APPROVED BY THE BUILDING OFFICIAL TO PERFORM SUCH WORK WITHOUT THE SPECIAL INSPECTIONS. <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 G-004 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 REBAR LIST 0 FIRST ISSUE BJK 01/30/20 0 BAR SIZE WEIGHT STANDARD REBAR CHART 3 0.376 1 1/8" 1'-0" 4 0.668 1 1/2" 1'-6" 5 1.043 1 7/8" 6 1.502 2 1/4" 7 2.044 2 5/8" 8 2.670 3" 9 3.400 4 1/2" 10 4.303 5" 11 5.313 5 1/2" 2'-0" 2'-0" 2'-4" 2'-8" 3'-0" 3'-6" 4'-0" BAR DIAMETER (in.) 0.375 0.500 0.625 0.750 0.875 1.000 1.128 1.270 1.410 MINIMUM OVERLAP LENGTHS INSIDE BEND RADIUS DRILLED HOLE DIA. 1/2" 5/8" 3/4" 7/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 5/8" A A B A D B C B C C A AD B C B C AD INSIDE RADIUS INSIDE RADIUS INSIDE RADIUS INSIDE RADIUS GENERAL FOUNDATION AND CONSTRUCTION NOTES: 1. CONCRETE TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS. 2. MAXIMUM ALLOWED WATER/CEMENT RATIO = 0.45 3. REINFORCED CONCRETE CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH ACI STANDARDS 318. 4. MINIMUM CONCRETE COVER OVER REBAR IS 3", OR AS NOTED. 5. BACKFILL SHALL BE SELECTED MATERIAL, WELL COMPACTED IN LAYERS NOT EXCEEDING 12". 6. BACKFILL SHALL BE PLACED SO AS TO PREVENT ACCUMULATION OF WATER AROUND THE FOUNDATION. 7. REINFORCING MATERIAL SHALL BE IN ACCORDANCE WITH ASTM SPECIFICATION A615. 8. ALL REBAR TO BE GRADE 60 (UNLESS NOTED OTHERWISE). 9. ALL REBAR (HORIZONTAL & VERTICAL) SHALL BE SECURELY WIRE TIED TO PREVENT DISPLACEMENT DURING POURING OF CONCRETE. 10. GROUT ALL REBAR DOWELS INTO EXISTING FOUNDATION WITH HILTI HIT-RE 500 V3 EPOXY. 11. EMBEDDED STRUCTURAL ANCHOR STEEL SUPPLIED BY AMERICAN TOWER. 12. COLD CONSTRUCTION JOINTS TO BE THOROUGHLY CLEANED AND WETTED PRIOR TO SECOND POUR. FOUNDATION AND ANCHOR TOLERANCES: ALL TOWERS: 1. CONCRETE DIMENSIONS: PLUS OR MINUS 1" 2. DEPTH OF FOUNDATION: PLUS 3" OR MINUS 0" 3. DRILLED FOUNDATIONS OUT OF PLUMB: 1.0 DEGREE 4. REINFORCING STEEL PLACEMENT: PLUS OR MINUS 1/2" INCLUDING CONCRETE COVER 5. PROJECTIONS OF EMBEDMENTS: PLUS OR MINUS 1/4" 6. VERTICAL EMBEDMENTS OUT OF PLUMB: 1.0 DEGREE 7. SEE CHART BELOW FOR THE MINIMUM OVERLAP LENGTHS OF REBARS IF REQUIRED. SELF-SUPPORT TOWERS: 8. FACE SPREAD DIMENSION CENTER TO CENTER OF ANCHOR BOLT CIRCLES: PLUS OR MINUS 1/8" PER 5'-0" OF FACE SPREAD 9. MAXIMUM DISTANCE FROM CENTERLINE OF ANCHOR BOLT TO CENTERLINE OF FOUNDATION: 1/24TH OF PIER DIAMETER UP TO A MAXIMUM OF 2" 10. MAXIMUM DIFFERENCE BETWEEN ANY TWO FOUNDATION ELEVATIONS: 2" 11. ANCHOR BOLT SPACING: PLUS OR MINUS 1/8" 12. ANCHOR BOLT CIRCLE ORIENTATION : PLUS OR MINUS 0.5 DEGREES 13. ANCHOR BOLT CIRCLE DIAMETER: PLUS OR MINUS 1/8" GUYED TOWERS: 14. GUY RADIUS: PLUS OR MINUS 3% OF TOWER HEIGHT 15. ANCHOR ELEVATION: 3% OF TOWER HEIGHT ABOVE OR BELOW TOWER BASE. IF ELEVATIONS OF ANCHORS VARY BY MORE THAN 3%, ANCHOR RADIUS IS TO BE CHANGED TO KEEP THE ANCHOR LOCATED ON THE GUY FORCE RESULTANT. CALL AMERICAN TOWER FOR ASSISTANCE IF REQUIRED. 16. ANCHOR ALIGNMENT: (PERPENDICULAR TO GUY RADIUS): PLUS OR MINUS 1 DEGREE. 17. ANCHOR ROD SLOPE: PLUS OR MINUS 1 DEGREE 18. ANCHOR ROD ALIGNMENT: TOWARDS TOWER CENTER POINT, PLUS OR MINUS 0.25 DEGREE 19. GUY ANCHOR HEAD SIDES VERTICAL: PLUS OR MINUS 1 DEGREE. <<w=175; h=175; n=BLANK - SIG; a=11>> X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0D2908-SM4X15STUD0D2908-SM4X15STUD M6X200C8112A-S THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 C-101 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 DETAILED SITE PLAN 0 FIRST ISSUE BJK 01/30/20 0 LEGEND GROUNDING TEST WELL AV, A/V AIR VENT ATS AUTOMATIC TRANSFER SWITCH B BOLLARD C CABINET CS COAX SHROUD CSC CELL SITE CABINET D DISCONNECT E ELECTRICAL F FIBER GEN GENERATOR G GENERATOR RECEPTACLE HH, V HAND HOLE, VAULT HFC HYDROGEN FUEL CELL HSM HYDROGEN STORAGE MATERIAL IB ICE BRIDGE K KENTROX BOX LC LIGHTING CONTROL LPG LIQUID PROPANE GAS M METER OHW OVERHEAD WIRE P POWER PB PULL BOX PP POWER POLE T TELCO TRN TRANSFORMER PROPERTY LINE ADJACENT PROPERTY LINE LEASE AREA EASEMENT WOOD FENCE WIRE FENCE METAL FENCE GUARD RAIL CHAINLINK FENCE ROAD (DIRT) ROAD (STONE) ROAD (PAVED) * * * o X 0 10' 20' SCALE: 1"=10' (11X17) 1"=5' (22X34) <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 S-201 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 MODIFICATION PROFILE 0 FIRST ISSUE BJK 01/30/20 0 HC2 HOLDINGS, INC. EL: 390.0' [PROPOSED] EL: 0.0' [BOTTOM OF STRUCTURE] FW: 3.5' TOWER ELEVATION VIEW EL: 440.0' [TOP OF STRUCTURE] NOTE: CONTACT AMERICAN TOWER FIELD OPERATIONS WHEN EXISTING EQUIPMENT INTERFERES WITH INSTALLATION OF MODIFICATIONS. ONCE APPROVED, EXISTING EQUIPMENT MAY BE TEMPORARILY MOVED DURING INSTALLATION & REINSTALLED TO THE ORIGINAL HEIGHT & LOCATION BY CONTRACTOR POST COMPLETION OF MODIFICATIONS. R = 295.0' COAX DISTRIBUTION PLUMB AND TENSION NOTES: 1. PLUMB AND TENSION TOWER UPON THE COMPLETION OF ANY OTHER REQUIRED STRUCTURAL MODIFICATIONS DETAILED IN THE MODIFICATION PACKAGE. REFER TO GUY WIRE TENSION CHART FOR REQUIRED GUY WIRE TENSION VALUES. 2. NOTIFY ATC ENGINEERING PRIOR TO RETENSIONING IF THE GUY ANCHOR DROP, RISE OR RADIUS EXCEEDS 15 FT AT ANY GUY ANCHOR LOCATION OR IF ANY GUY WIRE SIZE DIFFERS FROM THOSE STATED IN THESE DRAWINGS. 3. RETENSIONING OF EXISTING GUY WIRES SHALL BE PERFORMED AT A TIME WHEN THE WIND VELOCITY IS LESS THAN 10 MPH AT GROUND LEVEL AND WITH NO ICE ON THE STRUCTURE AND THE GUY WIRES. 4. PLUMB THE TOWER WHILE RETENSIONING THE EXISTING GUY WIRES. THE HORIZONTAL DISTANCE BETWEEN THE VERTICAL CENTERLINES AT ANY TWO ELEVATIONS SHALL NOT EXCEED 0.25% OF THE VERTICAL DISTANCE BETWEEN THE TWO ELEVATIONS (EXAMPLE, NOT TO EXCEED 0.6 INCHES FOR 20 FEET VERTICAL DISTANCE). 5. THE TWIST BETWEEN ANY TWO ELEVATIONS SHALL NOT EXCEED 0.5 DEGREES IN 10 FEET. THE MAXIMUM TWIST OVER THE STRUCTURE HEIGHT SHALL NOT EXCEED 5 DEGREES. 6. SEE "GUY WIRE RETENSIONING AND STANDARD SAFETY WIRE DETAILS" SHEET FOR ACCEPTABLE GUY WIRE TERMINATION EXTENSION, IF REQUIRED. 7. INSTALL / REINSTALL THE GUY ANCHOR SAFETY WIRE AS SHOWN ON THE "GUY WIRE RETENSIONING AND STANDARD SAFETY WIRE DETAILS" SHEET. 8. FOR GUY WIRE REPLACEMENT, PROVIDE TEMPORARY GUYING TO SECURE TOWER. CONTRACTOR TO ONLY REPLACE (1) GUY WIRE AT A TIME. HC2 HOLDINGS, INC. PROPOSED (1) 1 5/8" COAX INSTALLED ON TOWER FACE WITH LEAST AMOUNT OF EXISTING COAX RETENSION EXISTING 1/2" EHS GUY WIRE EL: 70.0' / I.T. = 10% BREAKING STRENGTH RETENSION EXISTING 5/8" EHS GUY WIRE EL: 140.0' / I.T. = 10% BREAKING STRENGTH RETENSION EXISTING 1/2" EHS GUY WIRE EL: 210.0' / I.T. = 10% BREAKING STRENGTH RETENSION EXISTING 9/16" EHS GUY WIRE EL: 280.0' / I.T. = 10% BREAKING STRENGTH RETENSION EXISTING 3/4" BS GUY WIRE EL: 350.0' / I.T. = 10% BREAKING STRENGTH RETENSION EXISTING 3/4" BS GUY WIRE EL: 420.0' / I.T. = 10% BREAKING STRENGTH EL: 20.0' SECTION 1 EL: 40.0' SECTION 2 EL: 60.0' SECTION 3 EL: 80.0' SECTION 4 EL: 100.0' SECTION 5 EL: 120.0' SECTION 6 EL: 140.0' SECTION 7 EL: 160.0' SECTION 8 EL: 180.0' SECTION 9 EL: 200.0' SECTION 10 EL: 220.0' SECTION 11 EL: 240.0' SECTION 12 EL: 260.0' SECTION 13 EL: 280.0' SECTION 14 EL: 300.0' SECTION 15 EL: 320.0' SECTION 16 EL: 340.0' SECTION 17 EL: 360.0' SECTION 18 EL: 380.0' SECTION 19 EL: 400.0' SECTION 20 EL: 420.0' SECTION 21 SECTION 22 INSTALL FOUNDATION PIER COLLAR AT EACH GUY ANCHOR [12'-0" X 12'-0" X 3'-6"] FROM EL: -2.5' TO 1.0'. SEE SHEETS S-501 & S-502 FOR INSTALLATION DETAILS. XX This portion can be permitted at a later date The plumb & tension and Anchor collar reinforcement is what is needed as soon as we can do it. <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 S-501 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 FOUNDATION INSTALLATION DETAILS 0 FIRST ISSUE BJK 01/30/20 0 PLAN VIEW TYPICAL FOUNDATION INSTALLATION DETAIL 295'-0" (TYP.) PLAN VIEW (NOT TO SCALE) 12 0 ° (T Y P . ) PROPOSED FOUNDATION PIER COLLAR (TYP.) TO CENTER OF TOWER 12'-0" 1'-0" (TYP. OF 3 SIDES) (10) EQUAL SPACES @ 12" = 10'-0" (TYP. OF 3 SIDES) 3" CLR (TYP.) 1'-0" (TYP. OF 3 SIDES) 3" CLR (TYP.) 12 ' - 0 " 1' - 0 " (4 ) E Q U A L S P A C E S @ 1 2 " = 4 ' - 0 " 3" C L R (T Y P . ) 3" C L R (T Y P . ) 6" 1' - 0 " 1' - 0 " (4 ) E Q U A L S P A C E S @ 1 2 " = 4 ' - 0 " 6" 9" MIN EMBED. (TYP.) B BA A PROPOSED FOUNDATION PIER COLLAR #6 X 11'-6" REBAR (TYP. TOP AND BTM SEE NOTE 2.) [24 TOTAL PER ANCHOR] #6 X 4'-6" DOWEL (TYP. TOP AND BTM SEE NOTE 3.) [26 TOTAL PER ANCHOR] #6 X 3'-10 1/2" REBAR (TYP. TOP AND BTM) [16 TOTAL PER ANCHOR] NOTES: 1. SEE SHEET S-502 FOR SECTION DETAILS "A-A" AND "B-B". 2. FIELD TRIM REBAR AS NECESSARY TO MAINTAIN 3" CLR FROM EXISTING GUY ANCHOR HEAD. 3. FIELD TRIM DOWELS TO MAINTAIN 3" CLR FROM EDGE OF PROPOSED FOUNDATION PIER COLLAR. 3. CONTRACTOR NOT TO BURY ANY OF EXISTING GUY PULL-OFFS ON ANCHOR HEAD. 4. EXISTING ANCHOR FENCING TO BE REMOVED PRIOR TO PROPOSED FOUNDATION PIER COLLAR INSTALLATION. INSTALL NEW ANCHOR FENCING ONCE INSTALLATION IS COMPLETE. SEE SHEET Z-501 FOR INSTALLATION DETAILS. 5. CONCRETE FOUNDATION PIER COLLAR TO BE INSTALLED AROUND (3) EXISTING PIER FOUNDATIONS. TOTAL CONCRETE REQUIRED: 50± CUBIC YARDS. 6. FOR REBAR LIST/FOUNDATION NOTES SEE SHEET G-004. 7. CONCRETE COVER OVER REBAR 3" MIN. (TYP.) U.N.O. 8. CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS = 4500 PSI. 9. SEE SHEET G-004 FOR DOWEL DRILLED HOLE SIZES. DO NOT CUT REBAR IN EXISTING FOUNDATION. 10. DRILLED HOLES SHALL BE FREE OF MOISTURE, DEBRIS AND LAITANCE. 11. GROUT DOWELS INTO EXISTING FOUNDATION WITH HILTI HIT-RE 500 V3 EPOXY. 12. REMOVE ALL LOOSE CONCRETE FROM EXISTING FOUNDATION PIER AND PAD PRIOR TO POURING NEW CONCRETE. 13. CRACKS & BROKEN CONCRETE TO BE CLEANED WITH BUSH HAMMER OR SANDBLASTING. AFTER CLEANING, ALL CRACKS TO BE ROUTED TO 3/8" - 1/2" WIDE & 1/4" DEEP WITH GRINDER. INJECT CRACKS WITH SIKADUR® 35 HI-MOD LV EPOXY AFTER ROUTING. PATCH IS THEN TO BE GROUTED FLUSH TO EXISTING FOUNDATION WITH HIGH STRENGTH NON-SHRINK GROUT. 14. COAT INTERFACE OF NEW AND EXISTING CONCRETE AND COLD JOINTS WITH SIKADUR 32® HI-MOD LPL BONDING AGENT OR APPROVED EQUIVALENT, PRIOR TO POURING NEW CONCRETE. ADDITIONAL SIKADUR 32® HI-MOD LPL BONDING AGENT MAY BE REQUIRED TO ACCOMMODATE FIELD CONDITIONS. 15. PRIOR TO INSTALLATION, REMOVE ORGANICS AND DELETERIOUS MATERIAL. COMPACT AREA UNDER PROPOSED FOUNDATION PIER COLLAR IN ACCORDANCE WITH ATC CONSTRUCTION SPEC. SECTION 312000. 16. CONCRETE, REBAR, AND FORM WORK SHALL BE IN ACCORDANCE WITH ATC CONSTRUCTION SPEC. SECTION 033000. 17. FOUNDATION DESIGN BASED UPON GEOTECHNICAL REPORT BY: DELTA OAKS GROUP, DELTA OAKS GROUP PROJECT GEO20-05594-05, DATED JANUARY 7, 2020. <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 S-502 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 FOUNDATION INSTALLATION DETAILS (CONT'D) 0 FIRST ISSUE BJK 01/30/20 0 GRADE 9" 3' - 6 " 6" C L R 2' - 6 " 6" C L R GRADE 3" CLR (TYP.) 1'-0" (TYP.) (4) EQUAL SPACES @ 12" = 4'-0" (TYP.) 6" (TYP.) 1'-0" (TYP.) 12'-0" 1'-0" (TYP.) (4) EQUAL SPACES @ 12" = 4'-0" (TYP.) 6" (TYP.)3" CLR (TYP.) SECTION "A-A" TYPICAL DETAIL SECTION "B-B" TYPICAL DETAIL (EXISTING ANCHOR HEAD NOT SHOWN FOR CLARITY) 3' - 6 " 6" C L R 2' - 6 " 6" C L R 3" CLR (TYP.) 1'-0" (TYP.) (10) EQUAL SPACES @ 12" = 10'-0" (TYP.) 12'-0" 1'-0" (TYP.)3" CLR (TYP.) PROPOSED FOUNDATION PIER COLLAR PROPOSED FOUNDATION PIER COLLAR #6 X 4'-6" DOWEL (TYP.) [26 TOTAL PER ANCHOR] #6 X 3'-10 1/2" REBAR (TYP. TOP AND BTM) [16 TOTAL PER ANCHOR] #6 X 11'-6" REBAR (TYP. TOP AND BTM SEE NOTE 2.) [24 TOTAL PER ANCHOR] #6 X 4'-6" DOWEL (TYP.) [26 TOTAL PER ANCHOR] #6 X 3'-10 1/2" REBAR (TYP. TOP AND BTM) [16 TOTAL PER ANCHOR] #6 X 11'-6" REBAR (TYP. TOP AND BTM SEE NOTE 2.) [24 TOTAL PER ANCHOR] 9" <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 S-601 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 GUY WIRE TENSION CHART 0 FIRST ISSUE BJK 01/30/20 0 NOTES: THE MAXIMUM DEVIATION FROM THE DESIGN INITIAL TENSIONS ARE: 1. ±10% FOR GUYS < 1" DIAMETER, OF THE INITIAL TENSIONS SPECIFIED ON THIS TEMPERATURE/TENSION CHART. 2. ±5% FOR GUYS > 1" DIAMETER, OF THE INITIAL TENSIONS SPECIFIED ON THIS TEMPERATURE/TENSION CHART. <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 S-602 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 GUY WIRE RETENSIONING AND STANDARD SAFETY WIRE DETAILS 0 FIRST ISSUE BJK 01/30/20 0 STANDARD GUY WIRE HARDWARE HA R D W A R E Van Beest Green Pin® G-6315 OR Crosby® HG-227 ® Van Beest® E-6120 OR Crosby® G-414 Van Beest Green Pin® G-5263 OR Crosby® G-2130A SIZE U.T.S. W.L. SIZE PIN Ø SIZE SIZE SIZE SIZE PIN Ø 3/16" EHS 4.0 K 2.0 K 5/8 X 12 1/2" 3/16" 3/16" 3/8" HVY 5/8" 3/4" 1/4" EHS 6.7 K 3.3 K 5/8 X 12 1/2" 1/4" 1/4"3/8" HVY 5/8"3/4" 5/16" EHS 11.2 K 5.6 K 5/8 X 12 1/2" 5/16" 5/16" 3/8" HVY 5/8" 3/4" 3/8" EHS 15.4 K 7.7 K 3/4 X 18 5/8" 3/8" 3/8" 1/2" HVY 5/8" 3/4" 7/16" EHS 20.8 K 10.4 K 3/4 X 18 5/8" 7/16" 7/16" 1/2" HVY 5/8" 3/4" 1/2" EHS 26.9 K 13.5 K 7/8 X 18 3/4" 1/2" 1/2" 5/8" HVY 5/8" 3/4" 9/16" EHS 35.0 K 17.5 K 1 1/4 X 24 1 1/8" 9/16" 9/16" 3/4" HVY 5/8" 3/4" 5/8" EHS 42.4 K 21.2 K 1 1/4 X 24 1 1/8" 5/8" 5/8" 3/4" HVY 3/4" 7/8" 11/16" EHS 50.0 K 25.0 K 1 1/4 X 24 1 1/8" 11/16" 11/16" 7/8" HVY 3/4" 7/8" 3/4" EHS 58.3 K 25.7 K 1 1/4 X 24 1 1/8" 3/4" 3/4"1" HVY 3/4" 7/8" 7/8" EHS 79.7 K 39.9 K 1 1/2 X 24 1 3/8" 7/8" 7/8" 1 1/8" HVY 7/8" 1" 1" EHS 104.5 K 52.3 K 1 1/2 X 24 1 3/8"1" 1"1 1/8" HVY 1"1 1/8" 1/2" BS 30.0 K 15.0 K 7/8 X 18 3/4" 1/2" 1/2" 5/8" HVY 5/8" 3/4" 9/16" BS 38.0 K 19.0 K 7/8 X 18 3/4" 9/16" 9/16" 5/8" HVY 5/8" 3/4" 5/8" BS 48.0 K 24.0 K 1 1/4 X 24 1 1/8" 5/8" 5/8" 3/4" HVY 5/8" 3/4" 11/16" BS 58.0 K 29.0 K 1 1/4 X 24 1 1/8" 11/16" 11/16" 7/8" HVY 3/4" 7/8" 3/4" BS 68.0 K 34.0 K 1 1/4 X 24 1 1/8" 3/4" 3/4" 1" HVY 3/4" 7/8" 13/16" BS 80.0 K 40.0 K 1 1/2 X 24 1 3/8" 13/16" 13/16" 1" HVY 7/8" 1" 7/8" BS 92.0 K 46.0 K 1 1/2 X 24 1 3/8" 7/8" 7/8" 1 1/8" HVY 7/8" 1" 15/16" BS 108.0 K 54.0 K 1 3/4 X 24 1 5/8" 15/16" 15/16" 1 1/8" HVY 1" 1 1/8" 5 THREADS, MINIMUM DEAD END GRIP INSTALL SHACKLE INSTALL SHACKLE ANCHOR HEAD PLATE THIMBLE GUY WIRE TAIL DEAD END SLEEVE 5 THREADS, MINIMUM ALLOWED GUY WIRE TERMINATION MODIFICATION TO RETENSION GUY WIRES SEIZING WIRE INSTALLATION TYPICAL DETAIL GUY WIRE 18 GAGE SEIZING WIRE SEE NOTES 2 & 3SEE NOTE 1 GUY WIRE 18 GAGE SEIZING WIRE TYPICAL SAFETY WIRE INSTALLATION DETAIL W/O SHACKLES TYPICAL SAFETY WIRE INSTALLATION DETAIL W/ SHACKLES 3/8" EHS SAFETY WIRE (20 FT) (2) WIRE ROPE CLIPS, 3/8" THREAD SAFETY WIRE THROUGH ALL THIMBLES, TURNBUCKLE BODY AND JAW ENDS THEN FASTEN LOOP WITH (2) 3/8" WIRE ROPE CLIPS. 3/8" EHS SAFETY WIRE (20 FT) (2) WIRE ROPE CLIPS, 3/8" THREAD SAFETY WIRE THROUGH ALL THIMBLES, TURNBUCKLE BODY AND JAW ENDS THEN FASTEN LOOP WITH (2) 3/8" WIRE ROPE CLIPS. SEIZING WIRE INSTALLATION: 1. LAY ONE END OF THE SEIZING WIRE IN THE GROOVE BETWEEN TWO STRANDS IN THE GUY WIRE AND WRAP THE OTHER END TIGHTLY OVER THE PORTION IN THE GROOVE. 2. CONTINUE TWISTING WITH PLIERS TO TAKE UP SLACK AND TIGHTEN. WRAP SEIZING WIRE AROUND GUY WIRE FOR A WIDTH EQUAL TO THE GUY WIRE DIAMETER. 3. WRAP SEIZING WIRE TIGHTLY AGAINST SERVING, WINDING TWISTED WIRE INTO KNOT BEFORE CUTTING OFF ENDS OF THE WIRE. POUND KNOT SNUGLY AGAINST THE GUY WIRE. INSTALL LONGER TURNBUCKLE NOTES: 1. TO OBTAIN CORRECT GUY WIRE TENSIONS, IT MAY BE NECESSARY TO REPLACE THE DEAD END GRIP (PREFORM) OF SOME GUY WIRES DUE TO EXISTING OVER-CONTRACTED TURNBUCKLES. 2. IF EXISTING TURNBUCKLE IS ALREADY FULLY EXTENDED, THE COMBINATION OF SHACKLES AND A LONGER TURNBUCKLE AS SHOWN MAY BE USED TO PROVIDE REQUIRED ADJUSTMENT. ALTERNATIVELY, IF THE EXISTING GUY WIRE TAIL IS LONG ENOUGH, THE DEAD END GRIP (PREFORM) MAY BE REINSTALLED TO INCREASE THE OVERALL LENGTH OF THE GUY WIRE. 3. IF REMOVAL OF EXISTING DEAD END GRIP (PREFORM) IS REQUIRED, IT CANNOT BE REUSED. 4. IF EXISTING GUY WIRE GROUNDING IS REMOVED DURING MODIFICATION INSTALLATION, IT MUST BE RECONNECTED AFTER THE COMPLETION OF THE TOWER MODIFICATIONS. IF ORIGINAL GROUNDING IS BROKEN OR DAMAGED AND CANNOT BE RECONNECTED, GUY WIRE GROUNDING IS TO BE REPAIRED OR REPLACED. GUY WIRE <<w=175; h=175; n=BLANK - SIG; a=11>> THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF AMERICAN TOWER WHETHER OR NOT THE PROJECT IS EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION ON FILE WITH AMERICAN TOWER. DESCRIPTIONREV. DATEBY ATC SITE NUMBER: ATC SITE NAME: SITE ADDRESS: ATC JOB NO: DRAWN BY: APPROVED BY: DATE DRAWN: SHEET NUMBER: REVISION: 75123 FORT PIERCE - OMNIAMERICA FLORIDA 14101 W ANGLE RD FORT PIERCE, FL 34945 BJK NOY 01/30/20 OAA753661_C6_06 Z-501 ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 GUY ANCHOR FENCE & GROUNDING DETAILS 0 FIRST ISSUE BJK 01/30/20 0 ELEVATION VIEW ANCHOR GROUNDING DETAIL PLAN VIEW GUY ANCHOR GROUNDING DETAIL ELEVATION VIEW GUY ANCHOR FENCE DETAIL 6' - 0 " (T Y P . ) 1'-0" (TYP.) 6' - 0 " (T Y P . ) 15 ' - 0 " M I N . TO B O T T O M G U Y 2' - 0 " M I N . TO B T M G U Y 8'-0" MAX (TYP.) FENCE POSTS CONCRETE FOUNDATION (4000 PSI) LINE POSTS W/ CONCRETE FOUNDATION (4000 PSI) [SEE NOTE] PIPE CAP (TYP.) 4" HOT DIPPED GALVANIZED PIPE (TYP.) [PAINT YELLOW (WITH REFLECTIVE PAINT WHEN NO FENCING REQ.)] 3' - 6 " (T Y P . ) 3'-0" FINISHED GRADE FORK LATCH WITH COMBINATION LOCK 1" GAP BETWEEN FINISH GRADE AND BOTTOM OF GATE 4'-0" WIDE MAN GATE NOTES:. 1. REPLACEMENTS TO MATCH EXISTING FOOTPRINT, TYPE AND HEIGHT UNLESS NOTED OTHERWISE BY THE CM. 2. 8" MAX BEND RADIUS FOR GROUND CONDUCTORS. 3. ANCHOR FENCING POSTS MAY BE FIELD CUT TO FACILITATE INSTALLATION ON FOUNDATION USING FENCING POST FLANGES OR SIMILAR CONNECTION AS SHOWN IN DETAIL "A". CONTRACTOR TO FIELD DETERMINE AND PROVIDE ALL MATERIALS AND HARDWARE NECESSARY FOR FENCE POST FLANGE INSTALLATION. 3'-0" 10'-0" ELEVATION VIEW GUY ANCHOR GATE DETAIL 1'-0" (TYP.)POST (TYP.) FENCE PAD AND PIER FOUNDATION ANCHOR ROD FINISHED GRAVEL BASE W/ WEED BARRIER FAN PLATE GUY WIRE 5/8"Ø X 10'-0" GALVANIZED GROUND ROD (TYP.) 2' MIN. X X X X X X X X X X X X X X X X X X 1/2" CROWN FOR DRAINAGE 5'-0" GUYED TOWER GUY WIRES 2" X 2" 9 GA. FENCE FABRIC 1 1/4"Ø RAIL (TYP.) FAN PLATE 2"Ø IN-LINE POST (TYP.) FINISHED GRADE 3/16" X 3/4" STRETCHER BAR AT CORNER AND GATE POSTS 2 1/2"Ø CORNER POST PAD AND PIER FOUNDATION GUY ANCHOR WEED BARRIER 3/8"Ø TRUSS ROD WITH TURNBUCKLE AT CORNERS AND GATE 30 " M I N . O R 6" B E L O W FR O S T D E P T H FINISHED GRADE DEAD END SLEEVE (REQUIRED ON ALL DEAD END GRIPS) DEAD END GRIP & THIMBLE (TYP.) 3/8" EHS SAFETY WIRE (15'-0") TO BE RUN IN FIGURE 8 THROUGH ALL THIMBLES, TURNBUCKLE BODIES AND JAW ENDS. SECURE LOOP TO SELF WITH (2) 3/8" WIRE ROPE CLIPS. FAN PLATE 2' MIN. #2 SOLID, BARE, TINNED COPPER GROUNDING CONDUCTOR (TYP.) EXOTHERMIC WELD (TYP. AT ALL GROUNDING RODS) 5/8"Ø X 10'-0" GALVANIZED GROUND ROD (TYP.) MECHANICAL CONNECTION LISTED FOR APPLICATION PAD AND PIER FOUNDATION DETAIL "A" TYPICAL FENCING POST FLANGE ANCHOR PER NOTE 3 & DETAIL "A" POINT OF DAYLIGHT