Product Approval
t_ _ USER:Public User
Product Aooraval Menu>Predec:or Aonttrat nn Search>hanllraticn fisc>Application DetaB
'r y FL# 117804-R10
U Application Type Revision
Code Version 2017
Application Status Approved �n
Rodd
v V
Comments
Archived
Product Manufacturer Entegra Roof Tile,LLC
Address/Phone/Emaii 1289 NE 9th Avenue
Okeechobee,FL 34972
(602)-515-6933
thomasjemmett@boral.com
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
I
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Ties
Compliance Method Evaluation Report from a Holida Registered Architect or a licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida license PE-59166
. Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contrast Expiration Date 11/01/2018
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R10 COI 2016 01 COI Nieminen,odf
�I
Referenced Standard and Year(of Standard) Standard Year
ASTM 01492 2003
FRSAfM Apn12012 2012
SSID 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 1995
TAS 102(A) 1995
TAS 112 1995
Equivalence of Product Standards
Certified By
i
http7/wwwtioridabuddingorg/prlpr aop dti"aspx?param=wGEVXQwtDquovOjOH[%2bAMgsl7g%2bkb9MWULRpAyR%2fOOg31x7gHM6LOA%3d%3d 112
E)CTERIOR RESEARCH DESIGN,LLC.
Certifticate of Authortzatlan 1!9503
353 CHRISTIAN STREET,UNITH11 2
TRNTY ERD OXFORD,Cr 06478
(203)262-9245
EVALUATION REPORT
Entegra Roof rile,LLC Evaluation Report E39310.IL11-1-R4
r.NTEGRA 12-89 NE 9th Avenue FL7804-RI0
i
T Z- -
E Okeechobee,FL34972 Date of Issuance:11/02/20.0
(602)515-6933 Revision 4:10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 6IG20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Niemlhen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance With the but Edition (2617) Florida Building Code
(HYHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(HV`HZ jurisdictions)
LABEuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,'the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle_
ADVERTISEMENT:The Evaluation Report number preceded by the words"rrinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPEMON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through 8.
Prepared by:
zv-
7
Robeft.I.M.Nierrilnen,P.E. The racshnge sea]ameash wazauthvdz*dWRavnNk"L,'CP,
2o"
10/17MV.his damn as an cleectraMmW 518Atd
Florida Registration No.59166,Florida DC4 ANE1983 IMN- P.F-andm=enL StpedznTtdhnd=p1=haim bMU2rWwdt1Cd to the
Pmdu=AppravatAdmtahtraterardiathenaniedtilent
CEFmFicA,noN OF INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or Will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates. IE
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor Will acquire,a financial interest in any other entity involved In the approval process of the
product i
S. This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record foir any
project an which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.rpose.
I i ,
ROOFING SYSTEM EVALUATION:
1. SCOPE:
i
Product Category. Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof'file, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth
herein.
i
2. STANDARDS:
Section Prove Standard Year
1523.65.2 Physical Properties TAS 112 1995
1523.65.2 Wind Driven Rain TAS 100 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
3523.6.5.2.3 Static Uplift Resistance TAS 102 1995
3523.65.2.3 Static Uplift Resistance TAS 102(A) 1995
3. REFERENCES:
Entitv Examination Reference Date
ERD(TST6049) TAS 101 P39740.02.12 02/21/2012
ATL(TSr3782) Physical Properties RT0624.05-14 07/03/2014
ATL(T5T3782) Physical Properties RT0624.04-14 07/07/2014
ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015
ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015
An(TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/0712015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015
An(TST 3782) Physical Properties RT1103.05-15 11/07/2015
Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014
Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015
Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016
Miami-Dade(CER3592) HVHZ Compliance 16-0112.08 02/25/2016
Tile Roof Institute TAS 100,TAS 101,102,302(A) Membership Confirmation Current
PRI(QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018
I
I
I i
Exterior Research and Design,U.C. Evaluation Report E39310.11.11-1�R4
fridjlcnreofAadborhadorr895o3 eEDMON 12017)FBG HVHZ EVALUATION FL7804-RIO
Entegra Roof riles Revision 4:10/17/2017
Page 2 of 8
I
i
I
s �
TRiNffy ER®
4. PRODUcr mscRi mom.
4.1 TAS 112,Type 3a($lat-proflea
BERMUDA FIAT,PLANTAnom FIAT and HORIZON FLAT'
16° t .
� IO•
Y
Ig•
2'
< 7
10• Bea'
Bermuda Flat Plantation Flat
e
17-1W
Horizon Flat
' I
II
I
Exterior Research and Design,LLC Evaluation Report E39310.11AI-1-114
CertlfrcatcofAudivrtzvtivnp9503 6'"EDITION(2017)FBC HVHZ EVALUATION FL7804-RIO
Entegra RaofTlies Revision 4:10/17/2017
Page 3 of 8
i
i
j .
4.2 TAS 112,Type la(interlocking,high-profile) BELLA HIGH"S"
1trlt" 13,4
Bella High"5"
4.3 TAS 112,Type lb(interlocking,low-profile) ESTATE"S"and HAcmvDA
Nail Holes
o ,
0
o
Estate"S" Hacienda
43 TAS 112,Type 2a(non-interlocking,high-profile) GALENA SPANISH"S"and REGAL
i
17„
y
10"
Galena Spanish"S" Regal
I
Exterior Research and Design,4C. Evaluation Report E39310.11,11-14R4
CerQICOeopAUCfta ItfVng95W 6�mi-noP1(2o17)FBcHVHZxvAwAmN FL7804-RIO
Entegm Roof Tiles Revision 4:10/17/2017
Page 4 of 8
7rR NTY ERD
5. UivirrNnoNs;
5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, In any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was Used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
53 Fire classification is not part of this evaluation;refer to FOC I516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference Is made to FBC 1512.4.2-4 regarding field testing of completed the roof installations.
55 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS M,Appendix W.
5.6 Minimum underlayment shall comply With the RAS 118, RAS M or RAS 120,as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck.requirements shall be in accordance with applicable FOC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
6IG20-3.
6. lwrALLATiom:
6.1 Entegra Concrete Roof riles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions,but not less than the requirements of RAS 118,
RAS 119 or RAS 120,as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof rile shall be evaluated as a 'Moment-Based System' In
accordance With Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1:AERODYNAMIC MULTIPLIERS-L
Ille Batten Application Direct-Deck Application
Bermuda Flat 0.189 0.205
Plantation Flat 0.267 0.289
Horizon Flat 0.305 0.330
-Bella High'IS" 0.349 0378
Estate"S" 0.267 0.289
Hacienda 0.267 0.289
Galena Spanish"S" N/A 0M5
Regal 0.287 0.311
TABLEZ: REsToRING MOMENT DUE TO GRAVITY-M13(Fr-LBF)
Roof Slope(0)
'I'lle 2:12<G<3:12 3:12<0<4-12 4:12<0<S:1Z S:U< <6:12 6:32<
0<7-17 8>7-.1.2
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Bermuda Flat 5.22 6.43 5.17 637 5.09 6.27 4.98 6.25 4.86 6.00 4.72 5.83
Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7-52 6.44 732 6.26 7.04
Horizon 7.60 832 7.52 8.24 7.41 8.12 7.26 795 7.09 7-76 6.89 755
Bella High"S" 6.19 6.89 G-U 6.80 5.99 6.67 5.85 6,51 5.68 633 550 6.13
Estate"S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5-40 6.14
Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 655 5.56 6.39 5.41 6.22
Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A S.89 NIA 5.74 N/A 9.57
Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.62
Exterior Research and Design,U.C. Evaluation Report E39310M.11-1-114
cerdiftore of Audw&adda#SSW G"EDITION(2017)FBC HVHZ EVALUATION FL7804-1110
Entegra Roof Tiles Reidslon 4:10/17/2017
f 8
Page 5 o
�I -
TRINITYERS
TABLE 3A:ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT--LBF)
MECHANICAuy ATTACHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.1513r (ndn.19/32"
Tile Type K Size Shank Cup plywood) plywood) Battens
Nail One 1 lad Smooth or A
N 7.3 4
( } / 9 8 .9
Nail. Two(2) lad Smooth or Screw N/A 14.0 18.8 7A ,
Nail One(1) lad Smooth or Screw Eave 19.0 19.0 22.1
Nail One(1) lad Smooth or Screw Field 243 24.3 24.2
Bermuda Flat, Nail Two(2) lad Smooth or Screw Eave 31.9 31.9 32.2
Plantation Flat or Nal Two(2) lad Smooth orScrew Field 355 3S5 34.8
Horizon Nail Two(2) Sad Ring N/A 30.9 38.1 17.21
Nall' Two(2)' l0d' Ring' N/A 50.3' 65.51 483'
Screw One(1) IIS N/A N/A 30.8 30.8 18.2
Screw Two(2) d8 N/A N/A 51.7 51.7 24.4
'Installation with a 4-inch tile_headcap and fasteners located min.2X-inch from head of tile.
Nail One(1)2 lad Smooth or Screw N/A 8.8' 11.8= 4.1'
Nail Two(2) lad Smooth or Screw N/A 16.4 21.9 7.1
Nail One(1)2 30d Smooth or Screw Eave 19.02 19.0' 22.12
Nail One(1)2 lad Smooth or Screw Field 243' 243' 24.22
Nal Two(2) lad Smooth or Screw Eave 31.9 31_9 32.2
Estate"S"or Hacienda Nail Two(2) Sad Smooth or Screw Feld 35.5 355 34.8
Nail Two(2) Sad Ring N/A 27.8 37.4 28.8
Nail' -rwo(2)1 led' Ring' N/A 43.0' 675' 509'
Screw one W' Ila N/A N/A 25.82 25.82 22.92
Screw Two(2) u8 N/A N/A 47.1 47.1 49.1
'Installation with a 4-inch tile headlap and fasteners located min.2%-inch from head of tile.
2 For one(1)fastener installations,utilize hole that is approximately 4'Y.-inch from the interlocking edge.
Nail One(1) lad Smooth or Screw N/A 8.1 6.8 2:8
Nail Two(2) lad Smooth or Screw N/A 6.9 9.2 7.3
Nail One(1) lad Smooth or Screw Field 231 23.1 19.0
Nail One(1) Sad Smooth orScrew Eave 29.3 29.3 24.0
Nail Two(2) lad Smooth or Screw Field 27.6 27.6 38.6
Bella High"S",Galena Nail Two(2) lad Smooth or Screw Eave 38.1 38.1 41.8
, Spanish"S"or Regal
Nail Two(2) lad Ring N/A 28.6 41.2 19.4
Nal' Two(2)' 10d' Ring' N/A 33.1' 48.1' 50.9'
Screw One(1) d8 N/A N/A 20.7 20.7 18.1
Screw Two(2) 08 N/A N/A 43.2 431 29.8
'Installation with a 4-inch file headlap and fasteners located min.234 Inch from head of tile.
i
i
Exterior Research and Design,U.C. Evaluation Report E39310.11.11-1-R4
CertrflcoteofAvthcricaden#9503 6M EDITION(2017]nCHVHZ EVALUATION F12804-1110
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
I
I
I
j
TPJNITY EPO
TABLE 4:ATTACHMENT RESISTARtCE EXPREMD AS A MOMENT—MF(FT-LBF
MORTAR AND ADHESivE-SET SYSTEMS
Note from Entegra Roof 77e,LLC: The performance data listed in Table 4 are based on the respective adhesive manufacturers'test
reports and Miami-!Jade NOAs. Entegra Roof Tfle,CLC relies upon the adhesive manufacturers to provide these values far our Inclusion
in this FBC HVHZ Evaluation Report Please consult the individual adhesive manufacturer for information on product approvals,
limitations,revisions or other information for determining wind load and overturning moment performance.
Tile Adhesive
Tile Product Product Approval Placement Mf(ft-lbf)
'TILE BOND"'"by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 41
Bermuda 'Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 73
Flat, —"Polyset°RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 52
Plantation
Flat or "Polyset°AH-160"by ICP Adhesives& Interdependent(2-paddy) 43
Horizon Sealants NOA 17-0322-03 Independent(medium paddy,"30 g) 51
Independent(large paddy,45 g) 92
'TILE BOND'"by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 44
"Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421M Interdependent(2-paddy) 42
Estate"5"or "Polyset*RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 44,
Hacienda "Polyset°AH-160"by ICP Adhesives& Interdependent(2-paddy) 50
Sealants NOA 17-0322.03 Independent[medium paddy,"30 g) 37
Independent(large paddy,-54 g) 61
Mortar Various Per RAS 120 21'
"TILE BOND"'by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 481
'Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 521
Bella High "Polyset°RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 361
"S",Galena Interdependent(2-paddy) 30�
Spanish"5" "Polyset°AH-160"by ICP Adhesives&
or Regal Sealants NOA 27-0322.03 Independent(medium paddy,-30 g) 491
Independent(large paddy,-63 g) 94
Mortar Various Per RAS 120 251
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
E N T '
Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella nigh"S",Galena Spanish"S"
Exterior Research and Design,LLC. Evaluation Report E39310AL11-1-Et4
CesHfTaQte afaathOdrarlan N9SO3 6TM EDITION(2017)FBC HVHZ EVALUATION FL7804-RIO
Entegra Roaf Tiles Revision 4:10/17/2017
Page 7 of 8
i
• I '
i
TRINJ l ■ -ERR
I
i
I
and/or
&WAIR&I Allow,
EF"'Ow 5
oil
Labeling:Horizon Flat,Hacienda,Regal
8. Buiwiwis PERMITREQuIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installatioq of
this product
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee,FL Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
Ft.Myers,FL Horizon Flat,Hacienda
Deerfield Beach,FL Horizon Fiat,Hacienda,Regal
10. QuALrry ASSURANCE ENTITY:
PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777