HomeMy WebLinkAboutProduct Approvals WERIOR RESEARCH&DESIGN,LLC
r
CertiftwIte aftuthatuation 050
353 CHRISTIAN STREET,UNIT#13
Jj RINITTERE) OXFORD,Cr 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
East Coast Metals,Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-R4
Hialeah,FL 33010 Date of Issuance:09103/21308
Revision 4:03/17/201
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nierninen,P.E.for
use of the product under the Florida Building Code and Florida Building Code,Residential Volume- The products described
herein have been evaluated for compliance with the 5th
Edition(20?4)Florida Building Code sections noted herein-
DESCRIPTIOx. East Coast Metals Channel Metals
LASEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
Cote NUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Niernlinen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "r1rinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then itshall be done in its entirety.
h9ISPEc-tioN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection atthe job slte.at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
A3 yvx-
't-. W
S-is
Robert J.M-Nierninen,P.E. . -sJ AV The atthartmd by Rob-Melehm
4g.."A P.L mii?rmm maticeimawne2s an
Florida Regbtrodan No.39166,Rorldo DCA ANE1983
I,Itt aa• ?,v&dApWevAA*WnInrztCr;;=d to the named crient
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it Intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products itevaluates.
3. Robert Nleminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nierninen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. 1
5. This Is a building code evaluation. Neither Trinity I ERD nor Robert Alleminen,P.E.are,in anyway,the Designer of Record for any
Project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
s ifically for that purpose.
pect
Reviewed For
Code Compliance
kiayn&Shoemake,
01/22/2019
C-%US Niz
ROOFING CompcNwr EVALUATION:
1. SCOPE.,
Product Category: Roofing
Sub-Category: Rooflng Accessories that are an Integral Part of the Roofing System
Compliance Statement: San Coast Metals Channel Metals,as produced by East Coast Metals,have demonstrated compliance
with the following sections of the Florida Building Code through testing in-accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations j Conditions of Use set forth herein.
-2. STANDARDS*
Section Propertv Standard Year
I507.3.7 Installation,non-HVHZ TRSJ; Ml April 7012(0442) 2012
I518.8a Installation,HVHZ RAS 3-18,129-&220 2995
I523.65Z2 Static UpliftResistance TAS 101 1995
171121 Static Uplift Resistance SOCCI 557011 1997
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Static Uplift Resistance E42730.011j3 08M/2023
ERD(rsrlimg) Static UpliftlIesistance EC1v1;,SC6795-12-14-1 02/27/2015
ERD CIS4E049) Static Uplift Resistance ECIVI-5C6795-U14-2 02127/2015
Florida TEC(TST7393) TAS 101 S20.628R 10/27/2020
PRI CrST5878) TAS 201 ECM-Colroz-ol 09/21/200I
PRI(TM5878) TAS 101 ECfvl-003-O2-01 06/13/2008
PRI(T5r5878) TAS 101 EcrVI-00"Z-01 06/13/2009
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008
PRI(i*ST5878) TAS 101 EM1-0O6-M-01 06MI2008
PRI(TS75878) TAS 101. E04-007-02-01 05/23/2008
PRI(TSTS878) TAS 101 EZ WG08-02-01 061413/3008
Florida Building Code Attachment Requirements FRSA/rRI A - 0412012
Florida Building Code-HVH7- Attachment Requirements RAS and:120 MS
East Coast Metals Metal Quality Certifications Various
Architectural Testing(QUA1844) Quality Control Participation Letter .22/32P-01 8
4. Piton=I)Esauprow
4.1 Hip & Ridge Channel Metal: Pre-fanned metal c nnel
deigned for use as a hip and ridge base to which f tiles
are banded in FBC Approved roof tile adhesive.
Hip&Ridge Channel Metal is available in W /84nch
3/8-inch)length by2.5A3.5,4,S.6or74n (_3/8-inch)
heights with 1.5-inch L-1116-inch)deck-flan
Exterior Research and DesIgn,U.C. atian Report E10240.08.03-R4
lertir
Reublon 4-02117J201S
Page 2 of 7
TPJ NITY ERD
4.2 Trim Lock, Channel Metal. Fre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for Interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/3-inch L+ at
3/8")length by 3,3.5,4,S or 6-inch(±3/8-Inch)heights
with 1.5-inch It 1/16-inch)deck-flanges.
4.2 Trim Lock Plus Channel Metal-Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal Is characterized by its profiled and is �jI
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive Z
and its perforated deck flanges, designed for Installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows-through and
interlocks with the underlying adhesive. /.r. Y.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(t 3/8")length by 3,3.5,4,5 or 64nch(±3/8-inch)heights
with I-S4nch L+1/16-inch)deck-flanges.
-d
4.4 East Coast Metals Channel Metals are fabricated of the following metals.
• Galvanized Steel: Min.0.019±0.0024 rich,ASTM A653(G-90),min.33 I(S).
• Galvalume Steel: Min.0.019±0.002-Inch,ASTM A792,A255,min.BS KSI.
• Aluminum: Mln.0.032±0.002-inch,ASTM B209,3003-1-124,min.21 KSI.
> Stainless Steel: Miq.0.019+0.002-inchASTM A240/A480,7304,min.35 KSI.
S. UmrrAncw.
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nierninen,P.E.are,in any way,the Designer Of
Record for any project on which this Evaluation Report,or previous versions thereof, is/weds used for permitting or
design guidance unless retained specifically for that purpose.
Exterfor Researds and Design,LLC- Evaluation Report E10240.08.08-R4
Certfjk a to of A u th a rkaOhn 99503 FL5374-R4
Revision 4:03/17/2015
Page2l of 7
-[RD
TRIN17f
5.2 FOR HVHZJURISDICnONS.-
5.2.1 For Hip &Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 218,Drawing 33, Detail 3;RAS M,
Drawing 12, Detail 3; or HAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal,refer to the installation
instructions herein.
5.2.2 For HVHZIurisclictions,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118,119 and
120,and the data in Tables 1A and 18 is supplemental to these prescriptivi allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance(MJ or uplift resistance(F,),
as determined in accordance with RAS 127,not greater than the fbilowmg.values.
Referto the-die adhesive manufacturer's published installation instructions for adhesive paddy placement details.
"INDEPENDENT"paddy placement means each indWidual tile is banded to the Channel Metal in its own,single
foam, paddy, tile head laps are not bonded. This method Is limited to 2-part the adhesives. Allowable
performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
> 'INTERDEPENDENT'paddy placement means each individual the is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
ThEmik PoiFoomAucEU=AnoNs-HVHZIwoEpammTPADDY PLAamewr
(2 21�b 1 OFSAWTALREADYAPPMED)
Hh IRIdge Metal Adhesive Allowable Performance.
Design Metal Type Tile Type Placement Moment eased Uplift Based
z Mr(ft-111f) F(Ibf)
Hip&Ridge galvanized day or 3W 2-Component Foam Independent 127 169
Channel Metal concrete Rual"File Adhesive AH-160—
galvanized,Gaivalumet, day or 3M—2-Component Foam Independent M 159
Trim Lock aluminum arstaintesssteel concrete Rool"Iffe Adhesive AH-160
Trim Lock Plus galvanized,Galvalume*, day or 3W 2-Component Foam independent 177 165
aluminum orstakilesssteelconcrete Roof Tile Adhesive AH 260
_1
TAeLEls:PERRmmANcELtmffATioNs-HVK7,INTewwewEurPADDY PLAamrw
f4To1AWW1NCF54FfiWAWFADYAPPVW)
Hilp/Ridgemetal Adhesive Allowable Performance
Tile Moment Based Upliftsased
Design Metal Type Type Placement M,(ft IbQ F(Ibf)
Trim Lock orTrim galvanized,GalwalumeP, day or 3W 2-Component Foam Interdependent 95 88
Lock Plus aluminum orstalnlesssteel concrete Roof Tile Adhesive AH-160
Trim Lock galvanized,GalvalumeP, day or 3W Roof Tile Adhesive Interdependent 99 94
stainless steel concrete RIA-1
Trim Lock aluminum day or 3Mm Foam Roof rile Interdependent 90 84
concrete Adhesive RTA-1
Trim Lock Plus galvanized,Galvalume*, day or 3M-Foam Roof Tile Interdependent 90 - 84
aluminum orstainless steel concrete Adhesive RTA-1
galvanized,Galvalume or day or TILE BOW'RoofTile
Trim Lock stairdemsteel concrete Adhesive Interdependent 223 117
clay or TILE BOND"Roof Tile
Trim Lock aluminum concrete Adhesive Interdependent 79 73
galvanized,GaivalumeO, day or TILE BOND'Roof Tile
Trim Lock Plus aluminum orstainless steel concrete Adhesive Interdependent 79 73
Trim Lock galvanized,GalvalumeP or day or Touch'n Seal StormBond Interdependent 146 139
staftilesssteel concrete Roof Tile Adhesive
day or Touch'n Seal Stormllond
Trim Lark Aluminum concrete Roof"nle Adhesive Interdependent 58 54
Trim Lock Plus galvanized,Galvalumec, c12 nBond Interdependent 58 54
aluminum or stainless steel concrete RaofTiileAdheslve
Exterior Research and Design,LLC. Evahiation Report E10240.08.08-R4
&Mricaft clAudwdmdan#35113 - RM74-114
Revision 4:03117/2015
Page 4 of 7'
RIMS ERS
5.3 FOR NOW-WHZJURLSDICTIONS:
53.1 For Hip&kidge Channel Metal or Trim Lock Channel Metal,refer to FRSA/TRI April 2012(04-12). For Trim Lock Plus
Channel Metal,referto the Installation instructions herein
53.2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined,In
accordance with Table 3A of MA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation Instructions for adhesive paddy placement details.
>
"INDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in its own,!single
foam paddy,the head laps are not bonded. This method is limited to 2parttile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to I margin of safety applied to ultimate performance.
> "INTERDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel metal Using a single
foam paddy- Allowable performance data below for"INTERDEPENDENT'paddy placement already has a 4 to I
margin of safety applied to ultimate performance.
TAsLE2A-.PomamANcEL=rrATioNs—WoN-HVH41meowENrPAoDYPLACSMMT
(ITal mmaiNoFs4wYALmvrmwuw)
Hip/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type Type Placement tPsf)
Hip&Ridge galvanized day or 3M—2-Component Foam Roof Independent 169
Channel Metal concrete Tile Adhesive AH-160
Trim Lock galvanized,Galvalumec,aluminum or day or 3M1 2-Component Foam Roof independent 273
stainless steel concrete I Tile Adhesive AH-16D
Trim Lock Plus galvanized,Galvalume,aluminum or day or 3W"2-Camponent Foam Roof Independent 178
stainless steel concrete TileAdhadveAH160
TABLE2B:PERFoRmANcELtmrrATior4s—No"VH4IN7mwM PAUDYPLACBwW
(4 W I AM R G TAI OFSA FMA LRFA DY APPUM)
Hip/Ridge Metal — 'rile Adhesive Allowable'Llpfifli:
Design MetalType Type Placement (PSO
Trim Lock or Trim galvanized,Galvalume*,aluminum or clay or 3M—2-Component Foam Roof interdependent 98
Lock Plus stainless steel concrete Tile Adhesive AM-160
Trim Lock galvanized,Galvalume or sta7hiless day or 3M-Foam Rool"Ille Adhesive interdependent no
steel concrete ffkwl
Trim Lock aluminum day or 3M'11 Foam RoofTHeAdheslve interdependent 93
1 1 concrete RTA-1
Trim Lock Plus gaivarfized,GaivalumePalurrdnumor dayor3M—Foam Rool"rile Adhesive interdependent 93
stainless steel concrete RTA-1
Trim Lock galvanized,Galvalume*orstainless day or TILE BOND—Roof Tile Adhesive interdependent 252
steel concrete
Trim Lock aluminum day or TILE BOND-RoofTHe Adhesive Interdependent 82
concrete
Trim Lock Plus galvanized,Galvalume3,aluminum or day or TILE ROND—Rool"TUe Adhesive Interdependent 92
stainless steel concrete
Trim Lock galvanized,Galvalume or stainless clay or Touch'n Seat Stormilond Roof interdependent 149
steel concrete 'rile Adhesive
Trim Lock Aluminum day or Touch'n Seat StormBond Roof Interdependent 61
concrete Tile Adhesive
Trim Lock Plus galvanized,GaInlume13,aluminum or clay or Tau ch'n Seal Star—tiftnfoof Interdependent 61
stainless steel concrete rile Adhesive
ExUrlar Research and Design,LLC. Evaluation Report E10240.08.08-R4
CaWl-ft afAuthadtatkii MO FL5374-R4
Revision 4-03/17/2015
Page 5al`7-
T IN a
6. IIWAUATION:
6.1 The roof deck shall be minimum 15/32-inch plywood(non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip&Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min.it ga.x IYA4nch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o c. along both deck-flanges. Fasteners shall be
positioned V Inch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVH2,refer to
FBC RAS 118,Drawing 13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of file adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lode Plus Channel Metal into the wet
adhesive and allow It to set-up prior to installation of roof tiles.
... N.
4,1 :. ;
R 10
T
View of Polyset AH160 Placementfor Trim Lock Plus channel Metal Installation
6.3.1 it is critical that the bond between the Trim Lode Plus Channel Metal,the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underiayments are the codified'30/90'system or other FBC Approved roof underlayments listing approved
use of the subject file adhesive.
Exterior Research and DeSIM LLC. Evaluation Report E10240.08.08-R4
eerttirrnre ojAuthadratfan M03 F15374-R4
Revision 4:Q3/17/2Q35
?age 6 of
i
li
RINITY ERD
6.4 Tile shall be Installed atop the Channel Metal in accordance with the tile adhesive manufacturees Approved,published
installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed With Approved mortar or weather blocking adhesive in accordance with FRSA/TRl April 2012(04-12) or RAS
US,RAS 1.19,RAS 120 requirements.
Hip/Ridge Tile
...........
.............. Tile Adhesive
Trim Lock Plus
1%
Ve
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive.
7. BUILDING PEwrr REQUIRsaiim:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MAmuFAcruRixG PLAN s:
Contact the named QA entity for manufacturing facilities covered-by F.A.C.Rule 61620-3 QA requirements.
9. QUALITY Awmmcii Emm:
Architectural Testing,Inc.—QUA1844,(717)764-7700
-END OF EVALUATION REPORT-
Exterior Research and Design,LLr_ Evaluation Report E10240.08-011-114
CordJkate of AuMarkadi7a 09503 F1.5374-114
Revision 4-03/17/2015