Code Version 2017 FL# ALL
Application Type ALL Product Manufacturer TAMKO Building Products LLC
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results,-A plications
FL# Type Manufacturer Validated By (Status
FL1960- Revision TAMKO Building Products LLC Locke Bowden P.E. Approved
RSO Category: Roofing (334)300-1800
History- Subcategory:Cements-Adhesives-Coatings
FL3901- Revision TAMKO Building Products LLC John W. Knezevich, PE Approved
R9 Category: Roofing (954)772-6224
History Subcategory: Metal Roofing
FL4103- Revision TAMKO Building Products LLC John W. Knezevich, PE Approved
R10 Category: Roofing (954)772-6224
History Subcategory:Roofing Accessories that are an Integral Part of
the Roofing System
FL12328- Revision TAMKO Building Products LLC Locke Bowden P.E. (Approved
R8 Category: Roofing (334)300-1800
History- Subcategory: Underlayments
FL13281- Affirmation TAMKO Building Products LLC Robert Nieminen, PE, NEMO Approved
R4 Category: Roofing ETC, LLC
History Subcategory: Cements-Adhesives-Coatings (203) 262-9245
FL17491- Revision TAMKO Building Products LLC Zachary R. Priest,P.E. Approved
R4 Category: Roofing (813)480-3421
History Subcategory: Modified Bitumen Roof System
FL18355- Revision TAMKO Building Products LLC Locke Bowden P.E. lApproved
R5 Category: Roofing (334)300-1800
History Subcategory:Asphalt Shingles
FL19948- Revision TAMKO Building Products LLC Locke Bowden P.E. lApproved
RS Category: Roofing (334)300-1800
History- Subcategory: Underlayments
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::PrivacyStatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 55.275(l),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
e0heck � .
https://www.floridabuilding.org/pr/pr_app Ist.aspx 1/2
I�
i
Certificate of Authorization No. 29824
1: C R E E K 17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,GP EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19,2017
P.O.Box 1404
Joplin,MO 64802
(417)624-6644
htto://www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAM KO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKOO Master ASTM D 6380,Class S,Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOO Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO®No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
I
i
CRTAMKO BUILDING PRODCUTS,INC.
K TAMKO Underlayments
0 TECHNICAL SERVICES,LLC
TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKO®TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO®Moisture Guard®shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO®TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof Mineral Wood
Asphalt Panels and Surfaced Roll Shingles and Slate Clay and
Underlayment Shingles Shingles Roofing Shakes Shingles Concrete Tile
TAMKO®ASTM Slate Y1 N N N N Y
Surfaced Roll Roofing
TAMKO®ASTM Tile N N N N N Y
Underlayment
TAMKO®Master Smooth Y' N N N N N
TAMKOO Moisture Guard® Y N N N N N
TAMKO®No.15 ASTM
Asphalt Saturated Organic Y Y Y YZ N N
Felt
TAMKO®No.15 UL Asphalt Y Y Y Y2 Y N
Saturated Organic Felt
TAMKO®No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKO®No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKO®TW Metal and Tile Y Y N N N Y
Underlayment
TAMKO®TW Underlayment Y Y N N N N
TAMKO®TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
I
i
�,�RK TAMKO BUILDING PRODCUTS,INC.
I1 TAMKO Underlayments
TEbHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
G REETj TAMKO BUILDING PRODCUTS,INC. �S• -
(� TAMKO Underlayments Am
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(201 7)as evidenced in the referenced documents submitted by the named manufacturer.
F1 P``,�tt1111I1Iy���,
ENS R'Ftr' �._. 2 017.10.19
No 74.021 12:15:58
-04'00'
.• STATE OF ���
,c
��T •. O P,.•N��. Zachary R.Priest,P.E.
�i�s• R C?��` Florida Registration No.74021
�'�is;0►vq Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not