HomeMy WebLinkAboutBuilding PlansTOP HEADER RUBBER COUPLING 4'x8', 19 OR 12' UPPER HOLD DOWN CLAMP SOLAR PANELS \ (SEE DETAIL A) (2 PER PANEL MIN.) NOT > 46" CTC, NOT < 16" CTC PANEL (TYP.) L— BOTTOM HEADER (SEE DETAIL B) PANELS SCALE= NT.S. w. He Copy R I �ED OR CODE COMPLIANCE ST. L CIE COU TY ATTACHMENT HARDWARE NOTE: CONTRACTOR TO USE OEM ATTACHMENT PARTS ONLY MOUNT A - (2) NO.14 x 2" MIN SS HEX WASHER HEAD OR SHEET METAL SCREW PER ANCHOR LOCATION DISTANCE DECREASES FOR COLLECTOR COUPLING ARRAYS ENCROACHING IN PRESSURE HOSE CONNECTOR ZONE 2 AND/OR 3 (2) NO. 14 x 2" MIN SS HEX ASHER HEAD OR SHEET METAL SCREW PER MOUNT N "A" LOCATION INTO PLYWOOD SHEATHING OR ONE SCREW I WITH FULL EMBEDMENT IN RAFTER OR TRUSS z 1 O O ``c/Poop O?O ~ V J c0 `�% '.CTOR HEADER 2.00" 1. D. U w m 0 COLLECTOR TUBES o N i N N O w �— EXISTING ROOFING m z w uj O C U Aml 1" DIA SS FENDER WASHER J MINIMUM 1/2" O.S.S. OR 112" COX OD SHEATHING ESIGNOF PER SCREW PLYWDETAIL SHEATOHINGBYOTHERS) SCALE- N.T.S. OEM PVC ANCHOR co 1/2" PLASTIC COATED 316 BUTTON OR 16 GA. 7/8" X STAINLESS STELL STRAPPING 1/2' SS ANGLE (1 1/8" .048" THICK, 670 LB BREAK N0.14 x 3" MIN SS HEX LONG) SLOTTED LEG FOR.. ;IN w STRENGTH WASHER HEAD OR SHEET STRAP INSTALLATION C a: METAL SCREW PER (TYPO 50" CTC MAX. j ANCHOR LOCATION ROOFING (EXISTING) MINIMUM 1/2" O.S.B. OR 1/2" COX CONTINUOUS PLYWOOD SHEATHING (DESIGN OF SS STRAP TRUSSES OR RAFTER I/ \I SHEATHING BY OTHERS) y�l ANCHORING SCREWS SHALL HAVE DETAIL B U z EMBEDMENT IN TRUSS OR RAFTER x 1/2" PLASTIC COATED 316 SCALE- NT& MAX. 50" CTC MAX. ALONG STRAP STAINLESS STELL STRAPPING Q N NO.14 x 3" MIN SS HEX .048"THICK, 670 LB BREAK WASHER CL ¢ n STRENGTH HEAD OR SHEET co METAL SCREW PER ANGLE OR = LL a m ] PVC BUTTON ANCHOR LOCATION ROOFING (EXISTING) F L) !J] rn = C .. Z W�a MINIMUM 1/2"O.S.B.OR1/2"COX Q y / PLYWOOD SHEATHING (DESIGN OF TRUSSES OR RAFTER) SHEATHING BY OTHERS) O DETAIL C 1. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE DRAWINGS WERE DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017) AND ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES". 2. WIND SPEED IS 170 MPH ULTIMATE VELOCITY (132 MPH NOMINAL WIND SPEED) RISK CATEGORY it STRUCTURES. 3. WIND EXPOSURE CATEGORY = C & q (SEE NOTE #7) 4. ROOF ANGLE: 0" TO 45" 5. HEIGHT OF STRUCTURE < 60 FT. 6. MEAN ROOF HEIGHT (MRH): UP TO 30' 7. SS STRAP SPACING FOR WIND EXPOSURE C IS 36" OC FOR ZONE 1, 24" OC FOR ZONE 2 , 16" OC FOR ZONE 3 FOR MPH UP TO 15'. SS STRAP SPACING FOR WIND EXPOSURE D IS 30" OC FOR ZONE 1, 20" OC FOR ZONE 2, 12" OC FOR ZONE 3 FOR MPH UP TO 15'. FOR EACH 5 FT. INCREASE IN MPH UP TO 30'- DECREASE STRAP SPACING BY 1". B. NO USE IN PRESSURE ZONE 31N HVHZ ANCHORING SCREWS SHALL HAVE SCALE- N.TS. EMBEDMENT IN TRUSS OR RAFTER MAX. 50" CTC MAX. ALONG STRAP NOT VALID WITHOUT THE BLUE INK SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED ENGINEER. PULL9,ED REQUIRES A MAY R P ONTFlLE.PLAN. a.SEALE 5 :W U: nR• pl to rb )B i INSTALL A 3/8' S.S. MACHINE SCREW, THROUGH TUBE INTO 1' SQ. X 1/8' ALUM, TUBE TOP OF S-5 CLAMP (6061-T6) "S-5" ALUM. CLAMP i� (6061-T6) INSTALL A MIN. OF (2) 3/8" BULLET NOSE STAINLESS STEEL SET SCREWS TO STANDING SEAM STANDING SEAM METAL ROOF CONNECTION ASSEMBLY SCALE,-- N.T.S. NOTE: FOR TIEDOWN ANCHORAGE OF SOLAR PANELS TO METAL ROOF, STRAPPING ASSEMBLES DETAILED ON PAGE S-1 SHALL BE ANCHORED TO ASSEMBLY DETAILED ABOVE FOR CONNECTION TO STANDING SEAM METAL ROOFS, SCREWS SHALL BE #14 X 1" MIN. SS HEX WASHER HEAD OR SS SELF TAPPING SHEET MEAL SCREWS. ASSEMBLY ANCHORAGE: INSTALL 1' SQ. X 1/8' SQUARE ALUM. TUBING TRACKS FOR SOLAR PANEL ANCHORAGE OVER 'S-5" ALUMINUM CLAMP (6061-T6 ALLOY) AS MANUFACTURED BY 'DYNAMIC FASTENER') OVER STANDING SEAM OF ROOF PANELS. CLAMP SPACING TO MATCH STRAP SPACING (48' CTC FROM PANEL EDGE TO PANEL EDGE, AND AS SPECIFIED ON PAGE S-1 FOR MAX. SPACING DADdnn m ouu nr D1l,ri\ LEGEND VACUUM RELIEF THERMOMETER SENSOR BALL VALVE CHECK VALVE NOTES: 1. CONTRACTOR IS ENCOURAGED TO INSTALL SYSTEM IN PRESSURE ,ZONE 1. IF PART OF SYSTEM MUST ENCROACH INTO P.i2ESSURE ZONE 2 OR 3, ANCHORING SHALL BE ADJUSTED AS PER S{, CIFICATIONSHEREIN. CONTRACTOR SHALL ATTACH COLLECTOR ARRAY W-,(H OEM MARDWARE h h AND STRAPPING. CONTRACTOR MUST BE CAREFUL='TO "CENTER" ANCHORS SO SCREWS ARE. INSTALLED INTO THE CENME -OF JTHE TRUSS TOP CHORD a OR RAFTER BELOW. AN APPROVED ALTERNATIVE WOULD BE CONTRACTOR a INSTALLED NOMINAL 2"X4" SOUTHERN PINE #2 BLOCKING BETWEEN TRUSSES OR RAFTERS AT SCREW LOCATION; CtRTERE-D�QA SCREW. a BLOCKING SHALL BE CONNECTED TO TRUSS-.- RUSS; OR RAFTER WITH SIMPSON a A34 OR A23 ON EACH FACE OF BLOCKING (2 C6NNECTORS PER Flat Roof Hip Roof (7^<6 A 27"t CONNECTION TO TRUSS OR RAFTER). S tii 2. CONTRACTOR SHALL ADHERE TO REQUIREMENTT OF"FBC'CHAPTER 15 (ROOFING) AND BEST PRACTICES OF NRCA ROOFING' & WATERPROOFING MANUAL TO ENSURE THE SOLAR INSTALLATION'qtlES}NOS CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM "AGES". h h 3. AS LONG AS CONNECTOR SPACING AND NUMBERSIARE NOT REDCUED THE a CONTRACTOR MAY USE A SUBSTRATE OR ALUMINUM MOUNTING FRAME, "SANDWICHED" BETWEEN THE COLLECTOR AND, OOF 91 FLUSH MOUNT INSTALLATIONS ONLY. f' a 4. (:!y` OEM STRONGLY RECOMMENDS AGAINST CLAMPS ONyTHE BOTTOM HEADER. 5. SOLAR UNITS INSTALLED PER THIS PLAN SHALL -,NOT FORM PART OF THE Gable Roof fB 57"1 Gable Roof (7"<Beg 45ot BUILDING ENVELOPE (I.E. WINDOW, DOOR). SOLAR UIJI:TS SHALL BE MOUNTED ABOVE ROOF SURFACE LIKE A A/C CONDENSER. THEREFORE ❑ hte pr zones End zones .rner zones 1bY,. b„MY,.Ln, NmI,. Ln,9WID-tm,] NOT REQUIRING A PRESSURE RATING (I.E. WINDOWS,,DOORS). SOLAR a.Ln] UNITS SHALL BE MOUNTED VERY CLOSE TO TI tE RWNSURFACE, TO PRESSURE ZONE NOTES PROVIDE PRESSURE EQUALIZATION BETWEEN7,7HE ROOFCSURFACE AND THE NTS BACK OF THE SOLAR UNITS. THIS RESULTS 1N NO SIGNIFICANT CHANGES IN THE LOADS ON THE ROOF FRAMING FOR A PARALLEL MOUNT AND PRESSURE ONE NOTES MODEST CHANGES IF TILT UP. HOWEVER THE INTERNA�AND EXTERNAL a. COMPONENTS OF WIND PRESSURE DECOUPLE; E G. THEryR00F RESISTS THE 10 PERCENT OF THE LEAST HORIZONTAL DIMENSION OR .4h, INTERNAL WIND PRESSURES AND THE SOLARIGNITS RESIST THE EXTERNAL WHICHEVER IS LESS, BUT NOT LESS THAN EITHER 4% OF LEAST WIND PRESSURES. THE EXTERNAL WIND FORCES'ARE THEN HORIZONTAL DIMENSION OR 3 FT. h: TRANSFERRED TO THE ROOF FRAMING THROUGH THE SOLAR ATTACHMENT MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE HARDWARE. r;pa USED FOR ROOF ANGLES < THAN 10 DEGREES. ,+") 0: ANGLE OF PLANE OF ROOF FROM: HORIZONTAL, IN DEGREES. 5. SOLAR POOL HEATING COLLECTORS ARE REQUIREDN40 BE TESTED, CERTIFIED AND LISTED BY THE FLORIDA SOL'AR-ENERGY CENTER. CONTRACTOR PROVIDE DOCUMENTATION TO OWNER OF THEIR FOR LISTING AND RATINGS. REVIEWED 3-WAY VALVE PROVIDE 1/4" STAINLESS STEEL TAPCON SCREW, VATER SENSOR OF ADEQUATE LENGTH TO SECURE BRACKET TO FILTER CEMENT TILE DRILL HOLE THRU CONC. TILE ONL) PUMP (NOT INTO ROOF MEMBRANE) AND INSTALL TAPC SO AS NOT TO BREAK TILES. AUKILLARY NEATER 1 (Ila) AUTOMATIC CONTROL - OPTIONAL COMPONENTS IM POOL GENERAL NOTE- ■ COMPONENTS ARE OPTIONAL TYP. PLUMBMO SCHE MAI= SDML. KTs NOTES: 1. PLUMBING SHALL BE INSTALLED AS PER DETAIL AND ALL REQUIREMENTS OF THE 6th ED. FLORIDA PLUMBING CODE (2017). SPECIAL CARE SHALL BE TAKEN REGARDING PIPE SUPPORT, PER FPC TABLE 308.5. THE ABS VALUE OF 4 FT. SHALL BE TAKEN AS THE MAXIMUM FOR HORIZONTAL AND 10 FT. FOR VERTICAL SOLAR PIPING. PER 6th ED. FLORIDA MECHANICAL CODE, CONTRACTOR SHALL INSTALL MANUAL DRAIN DOWN VALVES AND INSTRUCT OWNER IN DRAINING AND RE -STARTING THIS SOLAR POOL HEATING SYSTEM. OWNER SHALL BE INFORMED THAT FREEZE PROTECTION IS IP TO OWNER. IF SOLAR POOL HEATER FREEZES, IT IS THE OWNER'S SOLE RESONSIBILITY. FREEZE DAMAGE RESULTS FROM AN ERROR IN OPERATION. COLLECTORS SHOULD ALWAYS BE DRAINED BY OWNER OR OWNER'S REPRESENTATIVE IN ADVANCE OF NEAR FREEZING WEATHER. SS :R WASHER APPLY ADHESIVE TO THE INTERFACE OFT HE SOLAR VJORLD OUNTING BRACKET AND PVC BUTTON ANCHORS BEING ATTACHED,fO THE'° CONCRETE FLAT TILE OR BARREL TILE. CONTRACTOR SHALL ALSO APPLY ANCHORING EPDXY TO TAP CON SHAFT PRIOR TO INSTAI,LING*AP CON. TAP CON TO BE INSTALLED PRIOR TO EPDXY SETTING. A 3' X1'Sc1/6" ALUMINUM (ALLOY: 6061-T6) ANGLE MAY BE USED TO MOUNT PANELS TO TILE AS A CONTRACTORS OPTION. APPROVED ANCHORIV..EPDXIES ARE CHEMLINK "M-1", SUREBOND "SB-190" OR APPROVED EQUAL INTERMEDIATE BUTTON ANCHORS TO BE PROVIDED FOR SS STRAPPING AS DETAILED ON PAGE S-1. SPACING OF BUTTON ANCHORS ARE 48" OC ALONG THE SS STRAPING. SPACING OF STRAPING IS 27" OC (EXP. C) & 24" OC (EXP. D) FOR PRESSURE ZONE 1 AND 16" OC (EXP. C) & 12" OC (EXP. D) FOR PRESSURE ZONE f12. PANELS ON TILE SHALL NOT BE INSTALLED IN PRESSURE ZONE 3. ADJUST STRAPPING SPACING FOR MEAN ROOF HEIGHT OF STRUCTURE FROM 15 FT, TO 30 FT. AS SPECIFIED ON PG. S-1. BUTTON ANCHORS TO BE INSTALLED IN CENTER ATILE. STRAP BRACKET TILE ROOF < SCALE= N.T.S. CODE COMPLIANCE ST• LUCIE COUNTY SOCC - COLLECTOR HEADER 2.00" I.D. 5/32" WALL THICKNESS COLLECTOR TUBES 0.2201.D. WITH 0.030 WALL CONC. BARREL/FLAT TILE MINIMUM 112" O.S.B. OR PLYWOOD SHEATHING �IIRAFTER 1 EE \ gAN��G44 `\ �DRRj76F i1 QU� TL{JE �Wj INK SI NATUI 1 D EQVa AEAL OFEVERY F'ESMIT PULLED ` EOUIR& AA SE RIGINAL FFFAPER COPY C FIHISV:LE. P 60. BE L)FWFZR PLANS C N VJ LU no UI N > N D n¢n 2 LL2m w QON p Z W_L O F- O K g-1 J H < O_j 00 Z0 Fea O S U Z Q