HomeMy WebLinkAboutBuilding PlanTOP HEADER RUBBER COUPLING 4'x8', 10' OR 12' UPPER HOLD DOWN CLAMP SOLAR PANELS \ (SEE DETAIL A) (2 PER PANEL MIN.) NOT > 48" OTC, NOT < 16" CTC PANEL (TYP.) L BOTTOM HEADER (SEE DETAIL B) PANELS SCALE= NTS, &EWED FOR CODE COMPLIANCE ST. LUCIE COUN BOCC �? � ATTACHMENT HARDWARE NOTE: CONTRACTOR TO USE OEM ATTACHMENT PARTS ONLY MOUNT A - (2) NO.14 x 2" MIN SS HEX WASHER HEAD OR SHEET METAL SCREW PER ANCHOR LOCATION DISTANCE DECREASES FOR COLLECTOR COUPLING ARRAYS ENCROACHING IN PRESSURE HOSE CONNECTOR ZONE 2 AND/OR 3 (2) NO. 14 x 2" MIN SS HEX —WASHER HEAD OR SHEET METAL SCREW PER MOUNT C',"A" LOCATION INTO PLYWOOD 0 - SHEATHING OR ONE SCREW co WITH FULL EMBEDMENT IN RAFTER OR TRUSS 04 FEB 2'01010 F Permitting w W N Department :CTORHEADER fb(Hcb.0 ..tv o U w y COLLECTOR TUBES Way Z m S � m ,may O W �— EXISTING ROOFING m z O O U O N co WE I DIM SS FENDER WASHER 1/2" O.S.B. OR 1/2" CDX (DESIGN OF PERSCREW DETAIL A INMINIMUM SHEATHING HG BY OTHERS) SCALE= N.T.S. OEM PVC ANCHOR W 1/2" PLASTIC COATED 316 _ BUTTON OR 16 GA. 718" X STAINLESS STELL STRAPPING 1/2" SS ANGLE (1 1/8" .048" THICK, 670 LB BREAK NO.14 x3" MIN SS HEX LONG) SLOTTED LEG FOR STRAP SPACIN TRAPSPACC(SEE w STRENGTH WASHER HEAD OR SHEET STRAP INSTALLATION DETAIL C METAL SCREW PER (TYP•) SO" CTC MAX. ANCHOR LOCATION ROOFING (EXISTING) MINIMUM 1l2" O.S.B. OR 1/2" CDX CONTINUOUS PLYWOOD SHEATHING (DESIGN OF SS STRAP TRUSSES OR RAFTER SHEATHING BY OTHERS) DETAIL B ANCHORING SCREWS SHALL HAVE 1/2" PLASTIC COATED 316 EMBEDMENT IN TRUSS OR RAFTER SCALE- - N.T.S. MAX. 50" CTC MAX. ALONG STRAP STAINLESS STELL STRAPPING M .048" THICK, 670 LB BREAK N0.14 x 3" MIN SS HEX to STRENGTH WASHER HEAD OR SHEET io METAL SCREW PER ANGLE OR PVC BUTTON ANCHOR LOCATION ROOFING (EXISTING) TRUSSES OR 1. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE DRAWINGS WERE DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017) AND ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES". 2. WIND SPEED IS 170 MPH ULTIMATE VELOCITY (132 MPH NOMINAL WIND SPEED) RISK CATEGORY II STRUCTURES. 3.• WIND EXPOSURE CATEGORY = C 8 D (SEE NOTE #7) 4. ROOF ANGLE: 0" TO 45" 5. HEIGHT OF STRUCTURE < 60 FT. 6. MEAN ROOF HEIGHT (MRH): UP TO 30' 7. SS STRAP SPACING FOR WIND EXPOSURE C IS 36" OC FOR ZONE 1, 24" OC FOR ZONE 2 , 16" OC FOR ZONE 3 FOR MPH UP TO 15'. SS STRAP SPACING FOR WIND EXPOSURE D IS 30" OC FOR ZONE 1, 20" OC FOR ZONE 2. 12" OC FOR ZONE 3 FOR MPH UP TO 15'. FOR EACH 5 FT. INCREASE IN MPH UP TO 30'- DECREASE STRAP SPACING BY 1". S. NO USE IN PRESSURE ZONE 3 IN HVHZ m VN \ DETAIL C SCALE= N.T.S. MINIMUM 1/2" O.S.B. OR 112" COX PLYWOOD SHEATHING (DESIGN OF SHEATHING BY OTHERS) ANCHORING SCREWS SHALL HAVE EMBEDMENT IN TRUSS OR RAFTER MAX. 50" CTC MAX. ALONG STRAP NOT VAUD WITHOUT THE BLUE INK SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED ENGINEER. ` PULLED REQUIRES A MAY VYi1G1 OF THIS PLAN. MAY `B . R P 11N FILE. 0�\\\GINS gL i 10 A I-- � - i8 A,....., ROF�g?GAP U z LLILU m 0_ m¢� zm m ^� z n fn y = C Z Wwa oN 0 F- a. O LL cc OW K Q Q = OJ 0 IL J Q Q N N 2 INSTALL A 3/8" S.S. N SCREW THROUGH TUBE TOP OF S-5 CLAMP . N 1' SQ. X 1/8" ALUM, TUBE (6061-T6) 1'f INSTALL A MIN. OF (2) 3/8" BULLET NOSE STAINLESS STEEL SET SCREWS TO STANDING "S-5' ALUM. CLAMP (6061-T6) NOTE: FOR TIEDOWN ANCHORAGE OF SOLAR PANELS TO METAL ROOF, STRAPPING ASSEMBLIES DETAILED ON PAGE S-1 SHALL BE ANCHORED TO ASSEMBLY DETAILED ABOVE FOR CONNECTION TO STANDING SEAM METAL ROOFS. SCREWS SHALL BE #14 X 1" MIN. SS HEX WASHER HEAD OR SS SELF TAPPING SHEET MEAL SCREWS. ASSEMBLY ANCHORAGE INSTALL 1" SO. X 1/8' SQUARE ALUM. TUBING TRACKS FOR SOLAR PANEL ANCHORAGE OVER 'S-5" ALUMINUM CLAMP (6061-T6 ALLOY) AS MANUFACTURED BY 'DYNAMIC FASTENER-) OVER STANDING SEAM OF ROOF PANELS. CLAMP SPACING TO MATCH STRAP SPACING (48" CTC FROM PANEL EDGE TO PANEL EDGE, AND AS SPECIFIED ON PAGE S-1 FOR MAX. SPACING DADAI I Cl m Died nV DAMM % GENERAL NOTE. is COMPONENTS ARE OPTIONAL TYP. PLUMISING f3CHE"M M srur.: KTS LEGEND VACUUM RELIEF THERM13METER SENSOR BALL VALVE CHECK VALVE 3-WAY VALVE NOTES: 1. CONTRACTOR IS ENCOURAGED TO INSTALL SYSTEM IN PRESSURE ZONE 1. IF PART OF SYSTEM MUST ENCROACH INTO PRESSURE ZONE 2 OR 3, ANCHORING SHALL BE ADJUSTED AS PER SPECIFICATIONS HEREIN. CONTRACTOR SHALL ATTACH COLLECTOR ARRAY WITH OEM HARDWARE AND STRAPPING. CONTRACTOR MUST BE CAREFUL TO ;,CENTER" ANCHORS SO SCREWS ARE INSTALLED INTO THE CENTER OF THE TRUSS TOP CHORD OR RAFTER BELOW. AN APPROVED ALTERNATIVE WOULD BE CONTRACTOR INSTALLED NOMINAL 2"X4" SOUTHERN PINE- #2 BLOCKING BETWEEN TRUSSES OR RAFTERS AT SCREW LOCATION, CENTERED ON SCREW. BLOCKING SHALL BE CONNECTED TO TRUSS OR>RAFTERaWITH SIMPSON A34 OR A23 ON EACH FACE OF BLOCKING (2,CCIVNEiCTORS PER CONNECTION TO TRUSS OR RAFTER). 2. CONTRACTOR SHALL ADHERE TO REQUIREMENT OF FBC CHAPTER 15 (ROOFING) AND BEST PRACTICES OF NRCA=ROOFING. & WATERPROOFING MANUAL TO ENSURE THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE -SYSTEM "AGES". 3. AS LONG AS CONNECTOR SPACING AND NUMBERS ARE NOT REDCUED THE CONTRACTOR MAY USE A SUBSTRATE OR ALUMINUM MOUNTING FRAME, "SANDWICHED" BETWEEN THE COLLECTOR AN,D_ROOF,.O& FLUSH MOUNT INSTALLATIONS ONLY. y 4. OEM STRONGLY RECOMMENDS AGAINST CLAMPS ONVTHE BOTTOM HEADER. 5. SOLAR UNITS INSTALLED PER THIS PLAN SHAALL=-NOT.FORM PART OF THE BUILDING ENVELOPE (I.E. WINDOW, DOOR). SOLAR UNITSISHALL BE MOUNTED ABOVE ROOF SURFACE LIKE A A/C CONDENSER. THEREFORE NOT REQUIRING A PRESSURE RATING (I.E. WINDOWS, -DOORS). SOLAR UNITS SHALL BE MOUNTED VERY CLOSE TO THE" ROOF,; SURFACE, TO PROVIDE PRESSURE EQUALIZATION BETWEENITHE ROOF SURFACE AND THE BACK OF THE SOLAR UNITS.. THIS RESULTSLIN NO -SIGNIFICANT CHANGES IN THE LOADS ON THE ROOF FRAMING FOR A`PARALLEL MOUNT AND MODEST CHANGES IF TILT UP. HOWEVER THEJNTERNAL AND EXTERNAL COMPONENTS OF WIND PRESSURE DECOUPLE, E.G. THE%`ROOF RESISTS THEO: INTERNAL WIND PRESSURES AND THE SOLAR„UNITS.RESIST THE EXTERNAL WIND PRESSURES. THE EXTERNAL WIND FORCES%ARE THEN h TRANSFERRED TO THE ROOF FRAMING THROUGH THE SOLAR ATTACHMENT HARDWARE. " 0; 5. SOLAR POOL HEATING COLLECTORS ARE REQUIRED Ta; BE TESTED, CERTIFIED AND LISTED BY THE FLORIDA SOLAOaENERGY CENTER. CONTRACTOR SHALL PROVIDE DOCUMENTATION TO OWNER OF THEIR LISTING AND RATINGS. / 1" CIA SS FENDER WASHER --, WATER SENSOR PROVIDE 1/4" STAINLESS STEEL TAPCON SCREWS OF ADEQUATE LENGTH TO SECURE BRACKET TO FILTER CEMENT TILE DRILL HOLE THRU CONC. TILE ON"Y -T PUMP (NOT INTO ROOF MEMBRANE) AND INSTALL TAPCON SO AS NOT TO BREAK TILES. 10� AUKILLARY HEATER Ili AUTOMATIC MNTR13L • OPTIONAL COMPONENTS 3M POOL NOTES: 1. PLUMBING SHALL BE INSTALLED AS PER DETAIL AND ALL REQUIREMENTS OF THE 6th ED. FLORIDA PLUMBING CODE (2017). SPECIAL CARE SHALL BE TAKEN REGARDING PIPE SUPPORT, PER FPC TABLE 30&5. THE ABS VALUE OF 4 FT. SHALL BE TAKEN AS THE MAXIMUM FOR HORIZONTAL AND 10 FT. FOR VERTICAL SOLAR PIPING. PER 6th ED. FLORIDA MECHANICAL CODE, CONTRACTOR SHALL INSTALL MANUAL DRAIN DOWN VALVES AND INSTRUCT OWNER IN DRAINING AND RE -STARTING THIS SOLAR POOL HEATING SYSTEM. OWNER SHALL BE INFORMED THAT FREEZE PROTECTION IS IP TO OWNER. IF SOLAR POOL HEATER FREEZES, IT IS THE OWNER'S SOLE RESONSIBILITY. FREEZE DAMAGE RESULTS FROM AN ERROR IN OPERATION. COLLECTORS SHOULD ALWAYS BE DRAINED BY OWNER OR OWNER'S REPRESENTATIVE IN ADVANCE OF NEAR FREEZING WEATHER. Flat of Gable Roof IB 57"1 Will Roof W< B 5 27"1 Gable Roof O"< e 5 46"1 (Interior Zones End Zones . CCoornm Zones PRESSURE ZONE NOTES NTS PRESSURE ZONE NOTES 10 PERCENT OF THE LEAST HORIZONTAL DIMENSION OR .4h, WHICHEVER IS LESS, BUT NOT LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3 FT. MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF ANGLES < THAN 10 DEGREES. ANGLE OF PLANE OF ROOF FROM HORIZONTAL, IN DEGREES. APPLY ADHESIVE TO THE INTERFACE OF THE SOLAR WORLD°MOU(JTING BRACKET AND PVC BUTTON ANCHORS BEING ATTACHED TO THE" CONCRETE FLAT TILE OR BARREL TILE. CONTRACTOR SHALL ALSO APPLY ANCHORING EPDXY TO TAP, CON SHAFT PRIOR TO INSTALbNG;1`AP CON. TAP CON TO BE INSTALLED PRIOR TO EPDXY SETTING.i Wx1"z1/8" ALUMINUM (ALLOY: 6061-T6) ANGLE MAY BE USED TO MOUNT PANELS TO TILE AS A CONTRACTORS OPTION. APPROVED ANCHORING EPDXIES ARE CHEMLINK "M-1", SURESOND "SB-190" OR APPROVED EQUAL. INTERMEDIATE BUTTON ANCHORS TO BE PROVIDED FOR SS STRAPPING AS DETAILED ON PAGE S-1. SPACING OF BUTTON AN40ORS ARE 48" OC ALONG THE SS STRAFING. PA T PING IS 27- L G SPACING OF S RA 66 (EXP. C) 8 24" OC (EXP. D) FOR PRESSURE ZONE 1 AND 16" OC (EXP. C) & 12" QC (EXP. D) FOR PRESSURE ZONE #2. PANELS ON TILE SHALL NOT BE INSTALLED IN PRESSURE ZONE 3. ADJUST STRAPPING SPACING FOR MEAN ROOF HEIGHT OF STRUCTURE FROM 15 FT. TO 30 FT. AS SPECIFIED ON PG. S-1. BUTTON ANCHORS TO BE INSTALLED INCENTER AND/OR TRAP B TRACKET TILE ROOF < a7 SCALE= N.TS, REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC COLLECTOR HEADER 2.00" I.D. 5/32" WALL THICKNESS COLLECTOR TUBES 0.220 I.D. VVITH 0.030 WALL m > m<n m U.< m m QUN FZn _ w<Nm cn CONC. BARREUFLAT TILE � MINIMUM 1/2" O.S.B. OR K O PLYWOOD SHEATHING RAFTER Q� IA W QD` jf11'NOU� TDfJE Egg INK SIGNATUR (0.14 AhD flR16�` AL OF IVPEBMIT A U.0 -1 _ 1 E7`0ji6 EVERY HIT PULLED SE�$gl�,���ry�p1RIGMAL O J EQUIR A PAPER COPY OF PL fgVCIN001'BE 0f*FLR PLANS ON a O Z O FILE. S