HomeMy WebLinkAboutBuilding PlansI s General The swimming pools and spas consist of one-piece fiberglass construction shop -formed over a mold. The material is fiberglass reinforced plastic (FRP), a minimum of 1/4 inch 6.4 mm thick composed of isophtalic resin, vinyl ester resin, and fiberglass. The surface finish is a then pentyl glycol gel coat. Viking Pools produces various styles of swimming pools and spas. When installed in accordance to Viking Pools installation procedures, the pools and spas comply with applicable requirements of the following codes: 2015/2018 International Building Code® (IBC) 2018 International Residential Code (IRC) 1997 Uniform Building Code (UBC) BOCA® National Building Code/2003 (BNBC) 2018 International Plumbing Code® (IPC) 2012/2015 IAPMO Uniform Plumbing Code (IAPMO UPC) 2003 ANSI/NSPI-5 Residential Inground Swimming Pools 2012 ANSI/APSP/ICC 5a Residential Inground Swimming Pools 2014 ANSI/APSP/ICC-3 Permanently Installed Residential Spas and Swim Spas 2017 Florida Building Code 6th Edition 2017 Florida Plumbing Code 6th Edition 2017 Florida Fuel/Gas Code 6th Edition 2017 Florida Mechanical Code 6th Edition 2017 Florida Residential Code 6th Edition 2006 ANSI/APSP-7 2013 ANSI/APSP/ICC-7 Suction Entrapment Avoidance 2011 ANSI/APSP-16 2018 International Swimming Pool and Spa Code - (ISPSC-ICC) 2007 ANSI/ASME-Al12.19.8 2014/2017 National Electric Code (NEC) 2015 Uniform Swimming Pool, Spa, Hot tub Code (IAPMO) The overall pool dimensions, depths and capacities are shown in Table 1 and Table 4. The units comply with ANSI/NSPI-5, specified in Section AG103.1 of the IRC, and IAPMO IGC-2000', specified in the UPC. Models described in Table 2, Table 3, and Table 4 can be placed up to 19-1/2 inches (49.5mm) above ground. These pools and spas may be placed with or without concrete or wood decking. Unless elevated portions of the units are protected from sunlight by soil berms, decking, etc., these portions must be coated with a UV-inhibifing opaque paint that is compatible with the laminate. All plumbing must comply with the IPC or UPC. Electrical work must comply with the code in effect at the construction site. The pool and spa must remain full of water at all times. A permanent sign, bearing the following statement, must be attached to the pumping equipment: Notice -The pool or spa is designed to remain full of water at all times. The pool shell may be damaged if the water level is allowed to drop below the skimmer. When appreciable draw -down is noticed or if it becomes necessary to drain the pool or spa, contact Viking Pools or its dealers for instructions. A permanent label must be installed adjacent to the above sign indicating the Viking Pools dealer's name, address and telephone number. Installation Procedure: Viking pools and spas may be installed without a soil investigation by a registered design professional(RDP), subject to the building official's approval, provided none of the following conditions are encountered at the site: 1. The existence of uncontrollable groundwater within the depth of the pool or spa excavation. 2. The existence of an uncompacted fill in contact with any portion of the pool or spa. 3. The existence of any soil types with an angle of repose that will not support the walls of the excavation at desired slopes. 4. Danger to adjacent structures posed by the proposed pool or spa location. 5. The existence of any cracks or openings in soil that would not confine sand or 1/2" clean gravel bedding. If any of the conditions above is encountered, excavation must cease immediately. The specified conditions at the site must then be General Notes reviewed and recommendations made by the RDP. The building official must approve the RDP's report before work is completed. The pool or spa excavation profile must coincide with the contours of the pool. The over excavation is minimum 6 inches (152mm) on the sides and ends. The over excavation at the pool bottom is minimum 4 inches (102mri The backfill for the pool or spa bottom is a layer of 3-inch-thick (76mm) bedding sand matching the pool or spa profile. This sand layer is compacted using a manual tamper and water. The pool or spa is then set into place using a crane, excavator or manually and be within 1 inch (25mm) of level. Simultaneous waterfill and sand backfill operations then commence. The sand is compacted with a tamper and water. The installer must ensure that the backfill level and water level are approximately the same throughout this procedure. After completion of the backfill and plumbing, the decking is placed. Decks are prepared as indicated in Figures 1 though 4: 1. Cantilevered concrete decks are constructed as noted in Figure 1 in all cases. 2. Cantilevered decks are constructed with brick or stone as noted Figure 2 in all cases. 3. Raised bond beams are constructed as noted in Figure 3 in all cases. 4. Aboveground installations are constructed as noted in Figure 4 in all cases. Barriers are required where pools are on premises of UBC Group R, Division 3, Occupancies or IBC Group R Occupancies. The barders must comply with Appendix Chapter 4, Division 1, of the UBC or Section 3109.4 of the IBC Expansive soils: For installation of pools or spas in expansive soils, the following additional installation details must be followed subject to code official's approval: 1. All surfaces adjacent to the pool or spas must be excavated to a minimum depth of 12 inches (305 rum) beneath the pool bottom and minimum 6 inches (152 mm) behind the pool walls. 2. Any soft or loose soils exposed by step 1 must be removed until exposed material is solid. If the soil is still soft and loose, the upper 6 inches (152 mm) of all horizontal excavation surfaces must be scarified and compacted with mechanical equipment. The compacted surfaces and the excavated wall surfaces must be maintained in a moist condition until the first lift of backfill or fill is placed against the surface. The term compaction implies any method necessary to consolidate the native and fill materials to keep the pool or structure from settling. 3. The excavated bottom area of the pool or spa must be backfilled with granular import material to approximately 6 inches (152 mm) below the bottom of the pool or spa, wetted and compacted. 4. The remaining 6 inches (152 moll must be backfilled beneath the pool or spa and outside the pool walls with compacted clean sand. The pool or spa must be filled with water as backfilling progresses to a level equivalent to that of the backfill. The backfill must be placed in compacted layers of approximately 6 inches (152 mm) while a uniform height of backfill is maintained around the pool or spa. 5. Positive surface drainage away from the perimeter of the pool and surrounding deck is required and critical to installations in highly expansive soils. Surface area drains and surface drainage swales or subdreins must be placed as needed to prevent ponding or saturation of the soil around the perimeter and vicinity of the pool to prevent excessive shrink -swell or volume changes in the soil. Identification: Viking pools and spas are identified by the following information imprinted on the top step of the pool or spa: manufacturer's name (Viking Pools) and address, pool or spa model designation, a coded serial number and the evaluation report number (ESR-2014). The units also bear the label of the quality control agency, Columbia Research & Testing Corporation (AA-527). Findings: That the fiberglass one piece swimming pools and spas are in compliance with the above listed codes as noted in ESR-2014 subject to the following conditions. 1. The construction and pooVspa installation comply with this report and the manufacturer's instructions. 2. Electrical and plumbing installation comply with the respective codes in effect at the construction site. 3.That all pools are installed in accordance with manufacturer's recommendations. 4. The pools and spas produced by Viking Pools Northeast, Inc. 176 Viking Drive Industrial Park, Jane Lew, West Virginia; Viking Pools Central, Inc., 10600 West Interstate 20 East, Midland, Texas; and Viking Pools, Inc., 121 Crawford Road, Williams,Califomia; Viking Pools Southeast,40119 Country Road 54E, Zephyrhills, FL are manufactured under a quality control program with inspections by Columbia Research &Tesfing Corporation (AA-527). FEB 21%20 ST, LuUe Gouaty PerMitting VIKING POOLS THE STANDARD of FIBERGLASS Page 1 General Notes Expansive Soils Page 2 Tables 1-4 Page 3 Figures 1-4 Page 4 Pool Models Page 5 Pool Models Page 6 Pool Models 7 Spa Models & Hydra Zone Models He e 81 Attemmive Recirculation Systems Length, Width and depth may vary up to 3%- all dimensions are to outside edge of roping, measured from parallel lines. Reviewed by Donald R. Poindexter, PE Florida Lic. No. 64901 4119 Trinity Dr Santa Rosa CA 95405 Phone 707-494-8761 Seal: R• CENS4P STATE OF r LOR10P`a s!oiva►. SEP 16 2019 �J w � to 1L c a � H a:M ^ J D Q � 5 $ ma o J N d) � O U ld C � cc U � U C r 0 in N MIN rn M r v rn C; .(✓ � ro n U W v f^�Q .QC ran li m LL li C m 0) z m c m c � � 0 Y Qa M n M O> do a. Z ro 4i OQ ==a= a oc 0 a Coa J Q a � �UU- C J -J C N T co - z U ro IV J Page of 8 7 ie L v 12" i_ BRICK, FILLED BLOCK, OR POURED CONCRIKE MAXIMUM } 24" 8 .X 8— a \ 12" I� 16" f / FIG.1 \ YPICAL CANTILEVER CONCRETE DECK 6"X6"-WlAX W1.4 T MIN. WIRE MESH OR REBAR NO. 3, ON T O.C. ,f 9n EACH WAY. SLOPED 1/4"=1' I I 61, k 66" 10.1 1/4"GALVANIZED FOR CLAY CHAIN (ADOBE) 3" THICK COMPACTED SOIL ONLY. SAND (TYPICAL) 4" MIN. THICK COMPACTED GRAVEL FOR CLAY (ADOBE) SOIL ONLY. SAND OR 1/2" CLEAN GRAVEL FIBERGLASS POOLSHELL FIG. 3 TYPICAL BOND BEAM CONSTRUCTION 3' MIN. $ e BACKFILLED DIRT REBAR NO. 4, ON 2' O.C. EACH WAY. 101, Length. vridth and depth may vary up to 3%- all dimensions are to outside edge of coping, measured from parallel lines. FIG. 2 CONCRETE DECK BRICK NATURAL WITH BRICK OR STONE STONE DECK 6"X6"- W1.4X 3' IN. WIRE MESHESHOR REBAR NO. 3, ON T O.C. EACH WAY. FIG. 4 TYPICAL ABOVE GROUND INSTALLATION 3" THICK CO CTED SAND (NPICAL 4"MIN. THICKCO 'ACTED MAXIMUM GRAVEL FOR CLAY 19 1/2" (ADOBE) SOIL ONLY. SAND OR 1/2" CLEAN GRAVEL FIBERGLASS POOL SHELL J 6" \L ECK Reviewed by: Donald R. Poindexter, PE Florida Lic. No. 64901 4119 Trinity Dr Santa Rosa CA 95405 Phone 707494-8761 Seal: �'.• STATE OF °'FSs�aNAIL r,/rrnummmSEP 1 6 �O� fn W O Z U c V! N n 1- 1 n 4 cp 10 th }i U U'^) m 7 VJ O UJ � Lu ��o' v m m ` m v u x O m li m IL 0a E m N � O) M 7 cO10 rn m n v Y L O O O OY_ Z O C 6 O 0 M< E f L a a W t a Q J 0 nLL J J C E t > � >1 co CL U m S N U cu J Page -�3of 8 TRINIDAD - TR 19,300 gal. approx. 0' m 3,$.. ISLAND BREEZE II- N 22,000 gal. approx. 0' o= � o > v E to vo 1Q 3 6 - " CARIBBEAN - MR 17,000 gal. approx. —„a o E E 30' "a 2 a ' SANTA BARBARA - RS 12,500 g pprox. 3 6- FIJI - FJI 12,000 gal. approx. v 19,600 gal.�approx 17,000 gal. approx. LF SHORES - GS 15,000 gal. approx. r ST.THOMAS -L 13,700 gal. approx. v T\c onvr« - uu 15,000 gal. approx. a Monaco - AT 21,000 Gal. Approx. :EZE - OB approx. 33'-6" io v ry m 3'-5" CANCUN - CC 3,_6„ SEA BREEZE - K 14,000 gal. approx. 16,000 gal. approx. 12,400 TRITON - TN 13,500 gal. approx. VALENCIA - ST 10,000 gal. approx. LAGUNA DELUXE - LGX 9,000 gal. approx. Reviewed by: Donald R. Poindexter, PE Florida Lic. No. 64901 4119 Trinity Dr Santa Rosa CA 95405 Phone 707-494-8761 Seal: STATE OF / ;-;k- '�kp [OR1�P: F '''V,"""1.SSION AL �a#,\\Ox `• 16 2019 to w O Z (3 C v r^ (V m R m M N +� U) m�^� W A U UJ O L � N M N LL V X O LL OLL //O� cC o aJ LL m r�i � 7 m rO10 rn CP � n CL o m � r- v n Q t o o R o>��// Q Z d o o Q C a L a a O O L a m r: C Q t t a a Q J Q J FULL ) C E c0 L > /R \N W 0)-0=_ }� L rL a) U N ,C a--i U_ Cu J Page 4of 8 POSEIDON - PS 17,500 gal. approx. ACAPULCO-AC 16,700 gal. approx. CHESAPEAKE -CP 10,500 gal. approx. 23'-11" m r A - CM approx. FREEPORT-FP 6,000 gal. approx. -CRUD .Approx. )A - AL approx. a TROPICANA - MP 2,500 gal. approx. 20' 30' AVAILABLE TO 39' IN LENGTH c o v 0 3' I CLEARWAY -SP v 3,600 ga prox. LAGUNA - LG 10,000 gal. approx. PANAMAI-BL Gallons Vary AVAILABLE T45' 30' IN LENGTH a, Reviewed by: ' Donald R. Poindexter, PE Florida Lie. No. 64901 m MAUI - MTK 4119 Trinity Dr Santa Rosa CA 95405 v ,300 gal. approx. Phone 707-494-8761 T ROCKPORT - PANAMA II - BL seat 12,600 gal. aPP Gallons Vary 1"�71gU1111111111r1//l/I//////i 42' 40 ���`\\•"a�'O C.E 0/4fa, 901 61 STATE OF T 3 T `' R tv v KINGSTON - AP Oceania - BHGI Venice �N1A1111N��x���x�"` 17,500 Gal. Approx. 19,300 Gal. Approx. TGEN 16.000 gall . approx. IIiISEP 16 2019 to W 0 Z n � M LU �aM v _ Pe O a) ula O m LL; LL LL MWiZ M ? oco m N n rO0— v Y L o o M CL a m MW /m O> of Z C 2 2 C \V m 0 0 //•�� m O L aIL Q J L.L Q m 1-2 0 u- E m d C E L O7 M T \O W N�> N V N }+ U Cu J J KEY WEST L 9,000 gal. ap -ARU I. Approx. -rm approx. C34' 15' L 3'T- „ M-1mill BAJA - SFF 9,000 gal. approx. CARMEL-FF 12,000 gal. approx. Barcelona - BAR 18,500 gal. approx. EMPRESS 7,600 gala Majesty - FR14 11,200 gal. approx. DELRAY - B 8,100 gal, approx. ME JAMAICA - LD 3,750 gal. approx. U 33' r � v —0 v m r n U m v v C/) o M 3_70 m ck ? . m CLAREMONT-V O aO M'1 m m LL 11,700 Gal. Approx. 'o LL rn 19 A ^^ Z 1..� ui m n °D r- 0 \\ L 35' o� O / CL M m WZ c a c o c o Q r E m t a a / a m o: aLL J Reviewed by: �' rp F U 0 w y L✓- Donald R. Poindexter, PE C t 6'-6 3' 4'-3" Florida Lic. No. 64901 J ro Co j 4119 Trinity Dr Santa Rosa CA 95405 fTS �_ — L Phone 707-494-8761 CU W }j C CANCUN D XE- CCX seat V N 11,500 gal. mx. "\`\ }� U \\\\\\\1\I II I I I I I I I I I ////' ICU 1s' op I,\ c.PO �'o •. STATE OF pp'• A. 4 MILAN- CTL-,,�' .�ORP76of O 2,450 gal. approx. '''��/� S81ONAWWLpr� G° U 1FY ,6 2.0,9 PLACID - BOS 475 Gal. Approx. � E m a E d n oo' � a o $od � o A 5� c a L_L_LJJ E JE m tg3mgNO tog!)1- ROYAL - Ft1� REGAL - RG 600 Gal. Approx. 600 Gal. Approz. PLACID SPILLWAY- BOSSW ROYAL SPILLWAY- RSW REGAL SPILLWAY- RGSW 475 Gal. Approx. 600 Gal. Approx. 600 Gal. Approx. SEMI CIRCLE TANNING LEDGE - TSCT 400 Gal. Approx. POOL-HZE 3,600 gal. approx. POOL-HZDXS 2,800 gal. approx. L 10^ TAHOE-LOS 450 Gal. Approx. 'SPILLWAY- LOSSW 450 Gal. Approx. RMOSA - VFTL RECTANGLE TANNING LEDGE - RTL 200 Gal. Approx. 400 Gal. Approx. 7' m SUPERIOR - CS TA -LRS 700 Gal. Approx. 420 Gal. Approz. MYSTIC - M 550 Gal. Approx. SUPERIOR SPILLWAY- CSSW SHASTA SPILLWAY - LRSSW MYSIC SPILLWAY- MSW. 700 Gal. Approx. 420 Gal. Approx. 550 Gal. Approx. Reviewed by: Donald R. Poindexter, PE Florida Lic. No. 64901 4119 Trinity Dr Santa Rosa CA 95405 Phone 707-494-8761 Seal: STATE OF 0 R1�P Al. �l? 162019 ,n w O Z DEBRIS REMOVAL SYSTEM SUCTIONOUTLEtSINSERIES VENTCOVERMAY (OPTIONAL) DEBRIS BE GUTTER DRAIN-\ 9 CONTAINMENT 11$°O VENT LINEN N (UCTIONO I(DRAINLOOR (SUCTION OUTLET) ATMOSPHERIC VENT PIPE LENGTH MINIMUM = 16' MAXIMUM = 30' \X/ WMIN 2P MAX GENERAL NOTES 1. THE DEBRIS REMOVAL SYSTEM IS TO BE INSTALLED IN ACCORDANCE WITH DRAIN MANUFACTURER'S RECOMMENDATIONS. 2. CONTRACTOR TO INSTALL VACUUM REU EF BACKUP SYSTEM IN ACCORDANCE WITH SECTION 424.2.6.6 FBGBUILDING 2007 AND SECTION R4101.6.6 FBGRESIDENTIAL 2007, INCLUDING 2009 SUPPLEMENT AND 2017 FBGaUILDING AND RESIDENTIAL 3. ALL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. 4. THE FLOOR DRAIN MEETS THE REOUI REMENTS OF ANSVASME Al12.19.&2007 AND DRAIN COVERS MEET THE REQUIREMENTS OF ANSVASME Al12.19.&200T FOR ANTI -HAIR AND BODY ENTRAPMENT AND ANSIIAPSPACGT 2013 STANDARD. 5. THIS DRAWING WILL SUPPLEMENT CONTRACTOR'S SPECIFICATION DRAWING ON FILE FOR METHODSAND MATERIALS OF CONSTRUCTION, REFER TO CONTRACTOR'S ENGINEERED AND SEALED SPECIFICATION DRAWING ON FILE WITH THE BUILDING DEPARTMENT. 6. ATTACH PLACARD WHICH STATES THAT VENT IS A SWIMMING POOL SAFETY DEVICE AND SHOULD NOT BE TAMPERED WITH. T. THE MAXIMUM VACUUM WITH ONE SUMP PLUGGED ANDTO RELEASE A BODY ENTRAPMENT ON THE OTHER SUMP WILL NOT EXCEED 4.5INCHES OF MERCURY IN 3 SECONDS B. MAXIMUM SUCTION PIPE VELOCITY SIX (6) FPS OR 59 GPM 9. AN APPROVED VACUUM RELEASE SYSTEM SUCH AS THE VAC -ALERT SVRS SYSTEM IS AN ALTERNATIVE TO THE OTHER SYSTEMS SHOWN. VENT COVER MAY BE GUTTER DRAIN SUCH AS HAYWARD MODEL SP-1019 90° ELBOWG FINISHED GRADE DUAL SUCTION OUTLETS IN PARALLEL WTH OPTIONAL ATMOSPHERIC VENT SYSTEM. TI TO BE INSTALLED IN ACCORD IMTI SECT4242662007 FLORIDA BUILDING CODE: BUILDING AND SECT R4101.6S 20 W FLORIDA BUILDING CODE: RESIDENTIAL, INCLUDING 2009 SUPPLEMENT. 201 GaO14 FLORIDA BUILDING CODE: BUILDING AND 2017 FLORIDA BUILDING CODE: RESIDENTIAL 2013 ANSVAPSPACC-T Supion SM.P.Mrd A.W.D. SWIMMING POOL WITHOUT RECIRCULATION MAIN DRAINS LOW (EXAMPLE) F'r— OUT TO OPTIONAL WATER FEATURE(S) OR SPA STANDARD NOTES: I: USES SCHEDULE 40 PIPE. LEGEND 2 DO NOT USE 90 DEGREE ELBOWS ON SUCTION SIDE, 3. CHECK VALVES MAY DE NEEDED IF EQUIPMENT IS MORE THAN IC ABOVE WATER UNE. )= FIBER OPTIC LIGHT TJOINT 4. KEE➢VALVES WITHIN FOF THE PUMP ANDNR FILTER. Pw� SKIMMER W MAIN DRAIN /y�' y 3-WAYVALVE ' JJJ RETURN 'ITS PLUMBING \ SPILLOVER Reviewed by: Donald R. Poindexter, PE Florida Lic. No. 64901 4119 Trinity Dr Santa Rosa CA 95405 Phone 707-494-8761 R• STATE OF/.:Q:pf )OrNnAilm n SEP' t 6 2fl19 In W 0 Z U c r O m V) N DID pDO ' n n r IIY..IIN___ S 03 N DO �! � n V w M 65 DO < _ 70 0 (1) m R x x m //�0 �DTLL e SOO I..L m OB m N v CV 00 r- r- O t O O CL d DO v O I \J a%cl� Z C ui 6 C O E O Q C L O L G D L t 0 A M a a J L.L m �_ 0 m rotL E m J ) C 9 N a a) 6=z W N ^d g N U N m J Page