HomeMy WebLinkAboutDrawingNEW UUUKS I U tat IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED
NO.
1
2
3
OPENING
WDTH.
36
36
36
HGT.
80
80
80
SO.
FTG.
20.00
20.00
20.00
WIND
ZONE
4
4
4
OPENING
PRESSURES
POS. NEG
40.2 43.8
40.2 43.8
40.2 -43.8
PRODUCT
APPROVAL
FN 0 67#2
FL20867.2
Fl 208--
DESIGN
PRESSURES
60.0 60 0
60.0 60.0
60.0 60.0
COMMENTS
KITCHEN - SMSMI
SIDE GARAGE
SIDE GARAGE - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE, NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 23 FT 2 IN
NAVARETTA RESIDENCE
7309 RESERVE CREEK DRIVEI DOOR REPLACEMENT PLAN
PORT ST. LUCIE, FLORIDA