Loading...
HomeMy WebLinkAboutPERMIT PACKAGE NEW (2) tanks specsAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 4/24/20 COUNTY Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT TYPE:GAS PROPOSED IMPROVEMENT LOCATION: Address: 11001 S INDIAN RIVER DR Property Tax ID #:3532-503-0030-000-6 Site Plan Name: POLHEMUS Project Name: POLHEMUS DETAILED DESCRIPTION OF WORK: EXTERIOR LP GAS TANK AND LINES CONSTRUCTION INFORMATION: Permit Number: Building Permit Application Commercial Residential X Lot No.2,3 Block No. 3 Additional work to be performed under this permit —check all that apply: _Mechanical XGasTank Gas Piping _Shutters —Windows/Doors Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: _ Cost of Construction: $ 2300 Sq. Ft. of First Floor: Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Theresa Polhemus Name: Cheyenne Ellison Address:11001 S Indian River DR Company: Elite Gas Contractors City: Fort Pierce State: _ Zip Code: 34982 Fax:(772)220-1829 Phone No.(772)220-9678 Address:2130 Poma Drive City: Palm City State: FL Zip Code: 34990 Fax: (772)220-1829 Phone No(772)220-9678 E-Mail:emcintosh@elitegasco.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mailemcintosh@elitegasco.com State or County License 18361 If value of construction is 52500 or more, a RECORDED Notice of Commencement is requires. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Not Applicable MORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR�ANNAATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."OMMENCEMENT C / 4 _/ �A. _ / XXL., S&aeure o wner/ Lessee/Contractor as Agent for Owner Sig �FVE�Co ractor/License Holder STATE OF FLOR COUNTY OF STATE OF FLORIDA COUNTY OF /YLdr>�w The forgoing instrument was acknowledged before me this day of Y��9�� . 20 V by The fo_rYoing instrume t was acknowledged before me this day of , 20 e2�by s O tti. �i� H �N rat ���f 'SO Name erson making atement. Name of p on makingFtatement. Personally Known OR Produced Identification Personally Known �// OR Produced Identification Type of Identification Type of Identification Produced Produced ignature f1' otaryvft_ Notary Public State of Florida Commission No. Desiree N Ztosh y Com GG 283399 -44W Expires 1211112022 (,Sigaahir o tl� .�t' Notary Public State of Florida Commission No. '� Desiree N Mc{ t 5 h _ ommisstord 93399 m Expires 12/11/2022 REVIEWS FRONT COUNTER ZONING REVIEW SUPERVISOR REVIEW PLANS REVIEW VEGETATION REVIEW SEA TURTLE REVIEW MANGROVE REVIEW DATE RECEIVED DATE COMPLETED ev. Sl101 H39'avl OZet 3NJB 0012'11 IUH1131w 'M O'J ¢Y03q Mpy WAMq y Z O 2 m ti o r k Z rn m n C/) m a to h-I i a CO m Z C, 0 7m�i Z oR x V r, � a Ewa � V n iwnnY WNW9AITIJIbWO �YNW 3s1OA3/iA1ISMbl36YM3bJd3tl 4S—W� xaawdmA3nu U OAAIIWAB3tl311:Nouroeaa3osao�3nans3JViNt6VA gYtl39wM NWJ3]N3i.'J3 tl3MJLL10lpJLN•.M:NOad/a0S3n 7VO37:S310NSa0A3Aans VM-VIgLLtlA3t31Ctl6•Aq0•:SAfGUY MMMOY 1107 �y E.VD078 Slub ,O`� way avaam 400X,°�"'� aad rmarau 1—._._, _ _ _./NAfi-YSt-mokei."N. Avaxwm saovav 37VOS 011ON',fM NOl1VO07 _ —i I I _.—.—.—.r �awm � — . tl^iV�i W.N Sh - 9107 llt-3•!J •ir! > EH0078 I awaxwamx m,ae� �� _ ��. A eaalremxm ..n.orl.umr d ilwvgix fp`44 .0 .ffJ. AMS0/HO =W lX.svenaam wwnmamuva,onfwwa >N0078 4107 it w-n<ml I Aga lu) TWOS OIHdVHD JO&C VO/807430H31d ld 3AI80 a3AIY NVIGNVS ON A Sn .gH70d VS383H1 80- 03aVd3ad (3JVYVJ 03HOV130 N0d NV7d 31/S) d3AYnS DlHd VYDOdOi 7 AYVC7Nnos r X (Ti = S � I O J r � r r rt' Michelle Franklin, CFA-- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: Parcel ID: Account#: Map [D: Use Type: Zoning: City/County: Ownership Theresa Polhemus 11001 S Indian River DR Fun Pierce. FL 34982 Legal Description B.S.HARRIS' S/D BLK 3 LOTS 2 AND3 Current Values Just/Market Value: $209,500 Assessed Value: $209,500 Exemptions: $o Taxable Value: S209,500 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collectors Office Download TRIM for this parcel: Download PDF 11001 S INDIAN RIVER DR 3532-503-0030-000-6 116384 35'32N 0100 RS-4 Count Saint Lucie County Total Areas Finished/Under Air (SF): 1,802 Gross Sketched Area (SF): 2.424 Land Size (acres): 0.41 Land Size (SF): 17,564 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. PIPE AND TUBING SIZING Table 15.1(o) Polyethylene Plastic Pipe Sizing Between FirstStage and Second -Stage Regulators: Nominal Outside Diameter (ITS) i Gas: Undiluted Propane Inlet Pressure: 10.0 psi Pressure Drop: 1.0 psi Specific Gravity: 1.52 Plastic Pipe S4 in. 3/4 in. I in. 11/4 in. 1'/s in. 2 in. Length SDR 9.33 SDR 11.0 SDR I1.00 SDR 10.00 SDR 11.00 SDR 11.00 (ft) (0.660) (0.860) (1.077) (1.328) (1.554) (1.943) 30 2143 4292 7744 13416 20260 36402 40 1835 3673 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 60 1473 2950 5322 9220 13924 25019 70 1355 2714 4896 8483 12810 23017 80 1261 2525 4555 7891 11918 21413 90 1183 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1983 3578 6199 9361 16820 .f 150 897 1797 3242 5616 8482 15240 175 826 1653 2983 5167 7803 14020 200 778 1539 2775 4807 7259 13043 225 721 1443 2603 4510 6811 12238 250 681 1363 2459 4260 6434 11560 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4989 8965 430 495 992 1789 3100 4681 8411 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4385 2000 221 443 798 1383 2089 3753 IPS: Iron pipe size. SDR Standard dimension ratio. Notes: (1) Capacities are in 1000 Btu; hr. (2) Dimensions in parentheses are inside diameter 2014 Edition Bulletin LP-7- R122H March 2010 Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Two -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life — The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both internally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps — Built-in 1/8 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability — A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation — A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation — The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. FISHER Figural. Type R1221-IFirst-Stage Regulator Superior Overpressure Protection — The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with a R622 or R652, the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant — Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. • Positive Draining Spring Case — When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. EMERSON Process Management Bulletin LP-7: R122H Table 1. Ordering If TYPE NUMBER CAPACITY BTU/HR CONNECTIONS NOMINAL OUTLET SETTING PROPANEM INLET x OUTLET R122H-AAJ 1.100.000 1/4-Inch x 1/2-inch NPT 10 psig (0,69 bar) 1 Capacity is based on 30 PSIG (2.07 bar) inlet pressure and 20% droop 114-18 NP WE 0: (11, INCHES Figure 2. Type R 122H Dimensions (rom) LP -Gas Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872 USA Telephone: 1 (800) 558-5853 Telephone: 1 (972) 548-3574 For further information visit www.fisherregulators.com/tp The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher COMM. Inc.. a business of Emerson Process Management. The contents of this publication are presented tar Womcational purposes only. and while every effort has been made to ensure their accuracy. they are rot to be construed as warranties or guarantees, express or Implied, regarding the products or services described herein or their use or applimWity. We reserve the right to modtfv or Improve the designs or spectitcations of sum products at any time without notice. Emerson Process Management does not assume responsibility for the selectim. use or maintenance of any product. Responsibility for proper sekKtion, use and maintenance of any Emerson Process Managerrrent product remains solely with the purchaser. k i EM ERSOM CEmetsonProms Maaa%moitRegutatorTechrokKM. Inc, 2M.2010:AllRigtrtsReserved Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Comp. • Protec Screel .tune 21110 • Hinh Canaclty • Inlet and Outlet Pressure Gauge Taps Figure 7. Type R622 Pressure Reduong Regulator Introduction telief !eight Type R622 direct -operated, spring -loaded regulators applications. These regulators can be used with provide economical pressure reducing control in natural, manufactured. or propane gases and have the a variety of residential. commercial. and industrial same inlet and outlet pressure capabilities. a FISHER EMERSON. Bulletin 71.1: R622 Specifications Body Size and End Connection StyleO Pressure Registration 1 /2 NPT inlet and outlet Internal Maximum Allowable Inlet Pressurel') Operating: 125 psig (8.6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure0) Operating to Avoid Internal Part Damage: 3 psid (0,21 bar d) above outlet pressure setting Emergency: 20 psi (1,4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/8-inch (3,2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open Cv for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients XT: 0.78 FD: 0.82 FL: 0.89 Flow Capacities See Table 2 Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature Capabilities() -20° to 160°F (-29° to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: Delrin® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1. The pressweltemperature limas in this Buliebn or any appkable standard ttmnation should not be exceeded. OeUvO is a marts owned by EL du Pont de Ntemours and Co In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table ?. Outlet Pressure Ranges Specifications The Specifications section lets specifications for Type R622 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER. INCHES (mm) SPRING FREE LENGTH, INCHES (mm) 1.8 to 2.2-inches w.c. (4 to 5 mbar) T 14453TOO 12 Purple 0.051 (1,30) 3.40 (86.4) 5 to 7-tnches w.c. (12 to 17 mbar) T14398TOO12 Orange 0.062 (1.58) 340(86.4) 6.5 to 9-Inches w.c. (16 to 22 mbar) T 14399TOO12 Yellow 0.067 (1.70) 3.61 (91,7) 9 to 13-tndles w.c. (22 to 32 mbar) T 14400TOO 12 Silver 0.072 (1,83) 4 10 (104) 13 to 20-inc tes w.c. (32 to 50 mbar) T 14401 T0012 Gray O 080 (2,03) 3.60 (91.4) 16 to 35-inches w.c_ (40 to 87 mbar) T14402TOO 12 Pink 0093(2,36) 3.52 (89,4) 1 to 2.2 pstg (69 to 152 mbar) T14403TOO12 Light Blue 0 105 (2.67) 3.66 (93,0) Quality Steel Corporation AG/UG Propane Tanks TEG WIpTN 1450 wg. AND UP A000nv1aAAT9 ARnvFr,Rnl imn/i iNnFGROUND (AG/UG1 VESSEL DIMENSIONS AND SPECIFICATIONS f1r f WATER I'bV/%11V1n1 DIAMETER HEAD OVERALL V OVERALL _—. — —. - - LEG* LEG** WEIGHT **QUANTITY FULLLOAD PERSTACK CAPACITY (OD) TYPE LENGTH HEIGHT WIDTH SPACING (lbs.) *120 wg. 24" Ellip. 5'-891 3' 1'-11/291 2'-101/2" or 3 -11 260 108196 16112 *250 wg. 3013 Hemi. 7'-1011 3'-8i1 1'-5" 4'-1111 480 54 9 *320 wg. 30i1 Hemi. 9'-711 3'-811 1'-5" 5' 620 45 9 500 wg. 371/2" Hemi. 10, 4'-2" 1'-8" 5' 950 37130 8 1 6 1000 wg. 4111 Hemi. 16' 4'-5" 1'-891 10'-110 1,800 17115 6 1 5 1450 wg. 461/2" Ellip. 171-411 4'-1111 1'-9" 11'-71 2,650 12 4 1990 wg. 461/2" 1 Ellip. 23'-116' 1 4'-11" 1 1'-913 16' 3,520 - 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary. ' Leg spacing;/- 20. Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. '• Full load and stack quantities vary by shipping location. Check with your salesperson for details. GeneralSpecifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1. Complies with NFPA 58. - Rated at 250 psig from -20° F to 125° F. All vessels registered with National Board. - Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 w '. j ' • ; , � � x � � L1 f i� Yr e�>re:-s�j.�s u'°n�'�i • � t � � r � Wig � • �NtN�t�Nc�� aNVy3M , • `L�:�= Llll- :�!.iT;t[ TR 7/ : r' �rrt%; . ti I;.riti1..31Nf �:. .•.. �_-_I f-••. la.. f_ 1�.= . i •..,,.�_ .0 r-,.. Mil- I�l/N7Y • ...ram—...n.. . • ..1 , OK 7/VU LIM[. "I.�l'• 'i�1;_:�t�,.�:1 .1•• •,; :i�t-� f�{wlli •� �. ii r-� I !f•= •M' 't ,:f''� 11 .jil...-ll, 1 i any►• Wvpusa . WO Piz J i J t =.gat _ PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and inside building shall be SCH. •40 Galvanized ASTM A120 or AGA approved.corrugated stainless steel -(C.S.S.T.) pipe. 2. All. polypipe and Wings shall be ASTM D251-3 or ASTM D2517 and shall be buped-outside underground at a depth of 18" with warning tape and tracer wire. 3. All pipe and meter locations are approximate and subject to change.- .4. All polypipe shall be joined by heat fusion or approved mechanical. couplings. 5. All'galvaniied plpib shall be threaded. 6: All. pipe shall be pressure tested to 20 # PSI for a period of 24 hours. ' iUNDERGROUND TANK INSTALLATION • 2 to G • DOWNGRADED AWAY _ FROM DOME — -�-• --► •:j .� � MIN. f" i •,' � j ` I ANODE CABLE ` • • - SACRIFICIAL ANODE • -� :..••�• - ' • _ ••- • (MAGNESIUM BAGj -7 •- • • : • eft �� �� ;}�•.;;� ! I'j :t3•f• . �j • f • • � �•" .�;. - REGQt/nIN 1'OIt a�i t • t f�s - f SMUT GAS OFF AT QU 51-DE VALVE I, UPI ..�... • rev E GA�n `• �I IS EIS O 110 TAPE - �j ' -� RIS£ . • GRADE/CONCRETE SLEEVE ..• •.tee • � ` • • :• v a o. , ��M ol • • a u40 r ♦ • C3,. o •.f j r..- ° SERVICE LINE "° o . U-noe onoU110 tr-OAS ColitAIHER TRACE HIRE