Loading...
HomeMy WebLinkAboutPlan View111111111111111111111 Property 0' 10, 20' Line � Scale Matthews Residence 10701 S. Ocean Dr., Lot 865 Jensen Beach, FL 34957 4 ��08 &NVlF aei p Permit Numbcr a air Sutb South st - as vis' Proposed Dock and Boat Lift for the Plan View �Mafthpw,_ Rnsirianr_a 3' /6 Proposed 4 piling boat lift roposed marginal dock (100 sq.ft. over MHW) Waterbody: Man-made canal off of the Indian River Width: min.100'+/- Wilco Construction, Inc. I Date: 12/20/19 (772)460-6928;FAX(772)460-6929 P_oPerty Line to be installed on top of existing seawall cap. No work in water. Matthews Residence 10701 S. Ocean Dr., Lot 865 Jensen Beach, FL 34957 Property Line m Permit Number 0 56-383517-001,002-EE 4 O JOUflledif DISTICI 11111111111111111111i 0' 10, 20' Scale e 3' y Proposed 4 piling boat lift roposed marginal dock (100 sq.ft. over MHW) 12 Waterbody: Man-made canal off of the Indian River Width: min.100'+/- 3' �irrs- Proposed Seawall CAP Repair Wilco Construction, Inc. Date: 12/20/19 Plan View Matthews Residence (772)460-6928;FAX(772)460-6929 The work specified herein ias been designed and all work shall be in accordance with the 2017 Florida Building Code (6th Edn.). All codes reference herein are per the latest adopted edition. STRINGERS: 2"x8" 0.4 ACQ spaced at max,16" with min.112" S lag bolts on each piling (lap spliced) Pilings: TYPICAL DOCK AND ACCESSWAY CROSS SECTION min. 8"0, 2.5 CCA (N.T.S.) PT wood, max. 10' OC OF Ely Width: Varies 4 m a APermit Number Decking: 514"x6" Composite Decking fastened wl min. 2.5" stainless steel composite decking screws To bE added as needed: 2"x6" 12" 0.4 ACQ strap block @mid stringers (fastened wlmin. 3 ea. min. " SS screws/nails) L 1 56-383517-001,002- i d p Southeast District 1 0 Nails Typical / Joist: J 2"x8" 0.4 ACQ on each side of piling. Bolted wl 518" SS cut rods. CANAL BOTTOM Seawall Side 1 I 6' min. Li penetration Cross View Matthews Residence- Wilco Construction, Dock Structural Inc. o O r Property0' 10, 20' Line Scale 3' Matthews Residence 10701 S. Ocean Dr., Lot 865 Jensen Beach, FL 34957 ON `�R 4 O* roperty Line a w Permit Number � 4 r 56-383517-001,002-EE a r b p Southeast District y° Proposed Dock and Boat Lift for the Plan View Matthews Residence 3' Proposed 4 piling boat lift Ldock(100 nal over MHW) dy: e canal off ian River in.100'+/- 3' Wilco Construction, Inc. (772)460-6928; FAX(772)460-6929 FL Property0' 10, 20' Line Scale to be installed on top of existing seawall cap. No work in water. 3' Matthews Residence 10701 S. Ocean Dr., Lot 865 Jensen Beach, FL 34957 17" 1" Permit Number a 56-383517-001.002-EE e p Southeast District o c V X 9-- Property Line Proposed Seawall CAP Repair Plan View Matthews Residence 3' 3' 4 piling boat lift Proposed marginal dock (100 sq.ft. over MHW) Waterbody: \ Man-made canal off of the Indian River Width: min.100'+/- Wilco Construction, Inc. (772)460-6928; FAX(772)460-6929 7245ys 4� 0 C s artman Ce.FL 4947 U �b T r has been designed and al work shall be in accordance with the 2017 Florida Building Code (6th Edn.). All codes reference hereir are per the latest adopted STRINGERS: 2"x8" 0.4 ACQ spaced at max. 16" with min.1/2" S! lag bolts on each piling gap spliced) Pilings: TYPICAL DOCK AND ACCESSWAY CROSS SECTION min. 8" O, 2.5 CCA (N.T.S.) PT wood, max.10' OC pF EIVt,r4G Width: Varies ¢ 4 Decking: 514"x6" Composite Decking fastened w/ min. 2.5" stainless steel composite decking screws To bE added as needed: 2"x6" 12" 0.4 ACQ strap block @mid stringers (fast ed wlmin. 3 ea. min. " SS screwsinails) Nails Permit Number I 56-383517-001,002-1 4 p Southeast District d� o� ''o $avas/ Joist: J 2"x8" 0.4 ACQ on each side of piling. Bolted wl 5/8" SS cut rods. CANAL BOTTOM Seawall Side r. 1 I 6' min. Li penetration V Matthews Residence- Wilco Construction, � i S, I �'s View Dock Structural Inc. oncrete Block —Ca' Filled C'000 (8" x16") 2' psi concrete 16" 8" .. �a a < ,.. a ., d .• .. ., e, a .e a .o �, G•, "� Rebar 41 41 < ;a •.a_ C � Qe e°.. '.°. e . .. .d. ., e' •. 'a• ° .e .. 'e. .• .a ud. a °, v' ° 'd. a .a o .. .a. .e ° .a 'e e d a 'd a e •a � .d°• � .°� as �. n � ae Existin Concrete Zi33NjcJ Canal Cap to Remain a � W .E.# � p UlI cross New Seawall Cap for the Wilco Construction, Inc. Date:12/30/19 Scale: Dim Section Matthews (Lot 865) (772)460-6928; Fax (772)460-6929 ENGINEERING RENEW: BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITH WIND LOAD REQUIREMENTS OF THE 6TH EDITION (2017) FLORIDA BUILDING CODE, PER ASCE 7, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOCIATIONSS ALUMINUM DESIGN MANUAL. BEAMS AND MOUNTING BRACKETS INSTALLED PER HI —TIDE INSTRUCTIONS WILL EXCEED ULTIMATE DESIGN WIND SPEED OF 180 MPH (EXPOSURE CATEGORY C OR D) BOATS ARE TO BE REMOVED FROM BOAT LIFTS PRIOR TO A MAJOR WIND EVENT. PILINGS: PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB —SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 2017. ALL PILINGS TO BE 8" MINIMUM DIAMETER 2.5 C.C.A PRESSURE TREATED WOOD, PRE —STRESSED CONCRETE OR COMPARABLE EQUIVALENT. p i. fD Q rL£LECTRICAL REVIEW.• t-41/2 HP ELECTRIC MOTOR 8.8 AMPS 0 115V EACH 4.4 AMPS 0 230V EACH QUANTITY: 2 TOTAL WATTS: 2024 X2 £L£C7RICAL REVIEW; 1 HP ELECTRIC MOTOR 12.8 AMPS ® 115V EACH 6.4 AMPS 0 230V EACH QUANTITY., 2 TOTAL WATTS: 2944 FEB 2 4 ;/ 0 ST. Lucie County, N07E TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY.' O y\r'E NB�B�oOo e N0.43866 � � � it VED DEC 0 9 1 STATE OF lu 4 VI e' Fe FL OR 0 °Oo 8° � N A o ono "�00000 D ROGER BABER P.E. NO. 43855 MCR PROFESSIONAL ENGINEERING C.A. NO. 26967 1014 NE PINELAKE DR. STUART,, FL 34994 Win. r�„►rin. rnrr�r• r.-F� MINIMUM (2) 3/8- DIA. SS LAG BOLTS FOR WOOD PILING OR SS CONCRETE ANCHORS FOR CONCRETE PILINGS PER PILING REOUIRED.MINIMUM (2) 3/8" DIA. SS CARRIAGE BOLT FOR ATTACHING MOUNTING TAB TO LIFT REQUIRED PER PILING. MOUNTING TAB CONSTRUCTED FROM 1/4- X 2- ALUMINUM 6061—T6 FLAT BAR. 9,000 LB. GEAR DRIVE & M L7 v BOA77IF7S AND MARINE PRODUCTS GEAR DRIVE X2 BOAT LIFT (2017 FBC) UU�O4050 SELVITZ ROAD FORT PIERCE, FL 34981 R. HTDE SCALE. N75 DATE:1/2/18 REV. 1 1-800-544-0735 WWWhi—tlde.Com