Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISION: GenPad pg 2.
;ETE PAD FOR GENERATORS D HONEYWELL UNITS) APPLICATIONS ONLY) llvl'_ roTy fl l plb \ T \ Y _ J ISOMETRIC VIEW FRANK L. SENNAR 0, -P.E. ALLOWABLE DESIGN PE#00465x9 f/j PRESSURE: SEE TABLE REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED ((��^] 2018 7 p FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER 0 LSI r _- ZO 1 S SEPARATE CERTIFICATION ON A 30B -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE-SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE ""ECKea, i cP.e. nrr SNur� WITH THE APPLICABLE BUILDING CODE $HALL BE LESS GO N F TIS[S5, P.E THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PE# 82 8 PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR VALID ROEVI -PERMIT ONLY N. GENERAL NOTES ANY ASSEMBLY AS SHOWN. 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). 2. POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. 3. MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. 4. THE AREA UNDER CONCRETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS..THESF CONCRETE PADS HAVE BEEN DESIGNED FOR A MINIMUM SOIL COEFFICIENT OF FRICTION = 0.25 AND MINIMUM BEARING CAPACITY OF 2,000 PSF AND MINIMUM SUBGRADE MODULUS = 100 PCI. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. 5. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et, al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN 15 7. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE TNSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 8. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR.. 9. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFI.0 PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA. AND. MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALI©ATE OUR CERTIFICATION. 10. , EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE ,,...INTENDED, CONCRETE PAD UNIT DIMENSIONS -(IN) -' MINIMUM, UNIT CONCRETE T WEIGHT PAD MODEL # WIDTH LENGTHiHEIGHT (LBS) 25.00 48.00, 29.00 360 FG3154-4G SCHEDULE (DLu o -w- - � 'ra� �xow PAD DIMENSIONS (IN) WIDTH LENGTH THICKNESS 30.56 53.56 4.00 PAD WEIGHT (LBS) WIND LOADS ALLOWABLE PRESSURE (PSF) ALLOWABLE RESULTANT (LBS) 240 30.72 296.93 25.00 48.00 29.00 407 FG3154-4G 30.56 53.56 4.00 240 33.13 320.25 25.00 48.00 29.00 435 FG3154-4G 30.56 53.56 4.00 240 34.57 334.21 25.00 48.00 29.00 448 FG3154-4G 30.56 53.56 4.00 240 240 35.26 340.85 25.00 48.00 29.00 513 FG3154-413 30.56 53.56 4.00_ 38.53 372.44 25.00 48.00 29.60 471 FG3154-4G 30.56 53.56 4.40 240 240. 240 240` 240 36:40 351.88 332.20 342.12 378.93 25.00 48.00 29.00 431 FG3154-4G 30.56 53.56 4.00' 34:37 35.39 3 38.70374.09 34.20 25.00 48.00 29.00 451 FG3154-4G 30.56 53.56 4.00 25.00 48.00 29.00 516 FG3154-4G 30.56 53.56 4.00 4.00 25.00 48.00 29.00 526 FG3154-4G 30.56 53.56 F PROVIDED BY MANUFACTURER, VERIFIED BY OTHERS. ,S SHALL BE CONSTRUCTED WITH SOLID PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH, Pc=.4,000 PSI AT 28' DAYS HOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS. LARGER CONCRETE PADS MAY BE DESIGNED PER DIFFERENT LOAD COMBINATIONS. )VIDE 5/8" DTA. (0.675" O.D.) GALV. TUBE ASTM A53B SCH 40 MIN. OR 1/2" DTA. SOLID COPPER BAR SPIKE, 4' MIN. EMBED. (ALSO SEE MIN. LECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE PAD FOR SLIDING RESISTANCE PURPOSE, 12 DIAMETERS EDGE DISTANCE (NOT SHOWN) . SIGNATURE ON SHEET 1, PHIS SHEET IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. IF THERE IS NO DIGITAL SIGNATURE ON SHEET I OR THIS SHEET DOES NOT CONTAIN AN ENGINEER'S .ORIGINAL SIGNATURE R SEAL, 19 %D N Z 0 tit O W I`1 CEco O �J In 4u�i��n r(� w H WII LLIn ^XW# �L! O 2 �•, w a x W vz a V � w->< w R x 'wL70 0igig c E WW xI7 wwu O_-' J W O W mOH LL Lo 0 "Z LU o W w 09 -1 0 C p n (DLu o -w- - � 'ra� �xow 0 o 0 r\ w w wLLJoo QCD °0 ur) c:)� Q V ¢ 0 ai p in LL w = LL Trq F p � p 0O U C) 7 O Lu H 8- S7 F LL w W w U) 3 V m 0" u) z ¢ Ln w'" �- Q a 'J cis o � Y Q � r o -w- - � 'ra� �xow - im5 rh eA w mJ �o-56 fJ H F F LL �w�oa z J J J C) wodv= " r n a � E hm�oz mzaozd Y su o LL U Q uy } COPYRIGHT ENGINEERING EXPRESS® 14-1669A SCALE: NTS UNLESS NOTED os