Loading...
HomeMy WebLinkAboutEnergy CodeRECEMM a-dt7eP-Miic -®�y-3 r y9s 2 4 1016 FORM R405-2017 Permittny Department St. LLW4 County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Departrnent of Business and Professional ReWLifi n - Rewje dW PeQfolmlance Mednod PfojectName: FREDCOMER BulderName: skeet 6WALEXANDI M1CMILE Paniolfca: Cdy,Sta1P-Zrc FT.PIERWE,68., Pbramiundes_ DesgnLoration: FL,FartPienE .b®fe1&fK¢ Coudy. St. Lucia P"idacbrutezohe 2) 1. Newmshuctionorejastirg Addition a War Types ON-0 SOL) Insulation Area 2 Smo�etaee'hy�oomi efnrhiy-%4b4w* &Fr.-WeAl5dafo R=13ft 354Meff b.11M► It-= fe 3 Q WA R-- if 4. NumberofBedrooms (Sedrms lnAddr7hon) 0(0) d. WA R= fF 5. Is Otis a worst rase? No 10.Cefling Types (297.0 sgiL) Insulation Area a UnderAtic(Vented) R=30.0 297.00ft- 6. 297 b.NdA R= fe Oondifiwnsdhmr belowgpad9W) 0 Q IN A R= IF 9�a 7. Wndows(110.0 sqa) Der Area Affr_RetAffir AH: FLRO®ARCOM 6 5M a. U-Factor. Sgl, U=1.01 75.001P SHGC: SHGC=025 b. U-f - SgL U=0.65 35AOfe 12'CaoFgsysters kBhNv Ef6uarg SHGC:: SHG�25 aCraddoed 36.0 58 5w a: 7bFad1w- RNA fe SHGQ 13.Re fiigsyslars Lstmft ftkff- q d. U-Factor. N/A ft a. Electric Heat Pump 27.0 HSPF:820 SHGC: Area WeighbadAverageOwshmhgDeplh: 2AW a AreaWa4ledAraage SHM O 14_Hatmalcosyskirs-NmhereaPired EL sglt) ksu�h Ann a Cap�cf�/A a -Slab 303radeEdgainsulation RSA 297.01E b-CorservationfanWres ERG b. WA R= ft' a WA R= W 15.Credits None Gkk5SffbWAMM 0-370 Total Proposed Moffod IDad 9.81 PASS Total Baseline Loads 1040 I hereby ontify that the plans and specifications covered by Review of the plans and this calculation are in wah tie Rhonda Energy Spet>ala<0F6 covered by this VFO .o Cade Rmidle PREPARED BY: Y min the Energy Codle. Before construction is completed m DATE:-3-3-2D2 this building will be Inspected for compliance with Section 553.M I hereby c hatty that this laidng, as is TiM h the Rmedm Enog �t +Cc&- OWNER/AG�. ske(I .rro+L 774) BUILDINGOFRCIAL: DATE: 21le 20 DATE: - Cantpfoee regries eerWwalion by the arwlhada unit r as lhat Uri a haler endasue gmfdes as roomed factay-sealed it accudloce with 14403 A 1. - Cunpliahce repo es an Aror Bare and' ' Iiiii iecpe i Ch ecifst in aoeordahce with R402A.1.1 old this Wga2 mWi es an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402A.1.2). RECENED FILE 430 Permitting. Department 3/3/2020 7:29 AM Ene St. Lucie County rgyGauge®USA6.0.02 (Rev. FBC 6ih Edition (2017)CompfiantSoOware Page tof4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tie: BuddrgType: OwnerName: #of Units: BuildmrName= PenrR006>ra< .Wad¢ FamgyType: New/Existing: comment FIRMCO MER User 1 Single-family Addition Oedhm s: 0 CondiLonedAma: 297 Total Stories: 1 WastCase No RotaBeAngle: O cn=svedti!#fmi¢ WIImlieHmseFMo A&hess1r Lot# BlooldSubdivision: PlatBooic Street SMALF701110RIACO2 C SLIat e CId➢.Mft.Zgic Fr PERM. FL, CLWATE _ / V DeslgnLcoation Design Temp TMYSite 97.5% 2.5% IntDesign Temp Heating Design DaTyTemp Winter Summer Degree Days Moisture Range FL.FadPieoe FL VHm_BEIICH L%M 39 9m 70 75 299 62 Lam BLOCKS Number Name Area Volume 1 LmgreHarg 297 2376 SPACES Number Name Area Volume IGtchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 FLROIDA ROOM 297 2376 NO 1 1 Yes Yes Yes FLOORS # FloorType Spars: Pabneter R Value Arm Tole Wood Carpet 1 Slab-On-GradeEdgeinsulation FLROIDA ROOM 76 ft 0 297 fP 0 0 1 ROOF V # Type Rand GWA� pad Materials Area Area Color Rad Barr Sdl2T SR Fseilit Fs7Il DIer$ PWEh Abwr. Tested Tested Insui. (deg) 1 Lip Compost3astftles 322111- 0fl. Medam N OS NO 09 No 0 226 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fault vermd 15O 297W N N CEILM # CeflingType Space R-Value Ins Type Area Framing Frac Truss Type 1 LhderAtlic(VaABM RRRODAROOM 30 Blown 2971 0.11 Wad 3I320207:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (20M Compliant Software Page 2of4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS _ 1 S 2 E AIR Exterior Exterior Frame -Wood Frame -Wood Caaity wroa r FLROIDA RO 13 27 8 FLROIDA RO 13 11 8 EEigR SbB3lfift Frarng Sakcr 216.0IF 023 0.5 88.0 111 023 05 A1eA® 0 0 DOORS # Omt D"Type Spam Storms U-Value W"MOr Height Ft In Ft In Area 1 N Wood FLROIDA RO None 2 .1 -1 .1 IF WINDOWS ChiEMbf= callo, M HP altiombffiNTL / V # Omt Wall ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation ImShade Screening 1 2 3 _ 4 5 6 7 S S S S S S E 1 1 1 1 1 1 2 Vial V®g6 Vary* Vinyl Vinyl WrA MEW Lo EEngle Lo E%ngb L�ESngle Law-ESingle Lo ESirgle Lo Mrgje now-Evinglia Yes 055 a25 N Yes 1.01 02i N Yes I.M 025 N Yes 1.01 0.26 N Yes 1-01 025 N Yes IIAM 02I N Yes Offi 0LM N 15D0° 150W 150tiF 15.0 fF 15.0 fF 15.DfF 2111.012- 200ir 100iu Drapesmrufs 2ft0in 1ffi0in unipmMm3ft 200in 100in Drdipm 'ved5 2R0in IRO In Drapeslblinds 2110ir 100 in Drapeslbfurds 2ROin 1201ie DrAmsifidftads 220® 114 inn M2pesUnts Erdaim1 EvaTkur1 Eaetiml E#edarl Emmiart 1 / INFILTRATION A scope 1111alhod SA CRA 50 E$A EdA ACH ACH59 1 Wholdrwsn ) J003254 195 1057 21DA4 AM 5 HEATING SYSTEM 8 arsnonaTypee SpWd Ellmrn ADucas 1 n Nuns score ESFF.A2 27iE3b tm 1 sgsin COOLING SYSTEM # SlistanTiTe SrrtAo Subkpe Effidency Caparilyr AuFlme S R Bb* Ducts 1 C0031URNSuppkmertAbra None Snmjk SEER 15 35 b13Ardbr 1003 cEm 08 1 53s" SOLAR HOT WATER SYSTEM FSEc Cant # camparyNa a Sys2em6fodAAi CdfiockwVbdeW cooemor Slnrage Area V111=3 FEF 3/6202D 729 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - RaRes2D17FBC 61h EcI lion (2017) CompBant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS —S — Air CFM25 (XIM H VAr-X V IF Location R-Value Arm Lo[afm Area LealugeType Handier TUr OUr ON RLF Heat Cod 1 Attic 6 59.4 fF Attic 14.8511' DefauBLeakage FLROIDAR (De%uB)c(Default)c 1 1 TMPERATURES Pam��mal T9reD N CallingFamac Coding [[X]JJan Him [[X�JFeb FFeb [[X]Mar E]1Apr [[]]May im [pC]�Jun Jul JJun [[XJ]Aug [[X]�Sep E]j Od [� Nov [XjJ Dec vBBeMkg L 1 lxlm Kl4 L 1 l 1 Jul l lAu9 l l lxJ Oct lxl N l l D FELS21011GReftmaece Hours sduadildmrwe 1 2 3 4 5 e 7 a 9 10 11 12 Cooling(WD) PM 78 78 78 78 78 78 78 78 78 78 78 78 CQotJ(WEN) PU 78 78 78 78 78 78 78 78 78 78 78 78 Heafing(WD) m as ® fm as 88 a � GE a a SE 88 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Tggoe An® wmhmr Farn llizaFmckm SPRva DaPdApasbrIA OfP 00 0.3 FLRO®AR0008 31=020729 AM EnergyGauge® USA 6.0.02(Rev.1)-RaRes2017FBC 8th Edfion(2017) ComptiantSoftware Page 4of4 * � 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12 Ducts, location & insulation level a) Supply duds R 6.0 2 Single-family or multiple -family 2. Single -fa b) Return duds R &0 c) AHU location FLROIDA ROOM 3. No. of units (d multiple -family) 3. 1 4. Number of bedrooms 4. 0 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. it) 6. 297 7_ Windows, type and area a) U-factor.(weighted average) 7a. 0.895 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7a 110.0 6. Skylights a) Wactor.(weighted average) 6a. NA b) Solar Heat Gain Coefficient (SHGC) Sb NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2 Masonry (Insulation R-value) B. Adjacent 1. Wood frame (Insulation R-value) 2 Masonry (Insulation R-value) 11. Ceifing type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A7_ 13.0 10A2. - 13. Cooling system_ Capacity 36.0 a) Split system SEER b) Single package SEER c) Groundfwater source SEER/COP d) Room und/PTAC EER e) Other 15.0 14. Heating system: Capacity27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 11.20 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 1) Heat recovery unit Heaf tec% -. g) Other 10B1. 10132. 16. HVAC credits claimed (Performance Method) a) Cetfing fans 11a. 19.0 b) Cross ventilation No 11b. c) Whole house fan No 11¢ d) Mult¢one cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Othenmise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 6207 ALEXANDRIA CIRCLE City/FL Zip: FT. PIERCE. FL i 2111202010:36:53 AM EnergyGauge® USA 6.0.04 (Rev.1) - FlaRes2017 FBC 6th EdWmn (2017) Compliant Software Page 1 of 1