Loading...
HomeMy WebLinkAboutBarker Product Approval Gulf LokBCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications % Contact Us BCIS Site Map ! Links Si d,b,, � USER:Product Approval " USER: Public User Product Approval Menu > Product or ApRlication Search > Application List > Application Detail FL # FL11651-113 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Gulf Coast Supply & Manufacturing, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-0778 info@gulfcoastsupply.com Eng David info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 david.eng@guifcoastsupply.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Profess Engineer Evaluation Report - Hardcopy Received Daniel S. Kuhn PE-75519 Keystone Certifications, Inc. 04/12/2024 Locke Bowden P.E. Validation Checklist - Hardcopy Received FL11651 R3 COI Cert of Independence 2017-10-09.pdf Referenced Standard and Year (of Standard) Standard FM 4471 TAS 100 TAS 110 TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 1992 1995 2000 2003 2012 2006 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # E Model, Number or Name .032" Aluminum SV Crimp 11651.1 T0 Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.2 10.032" Aluminum Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.3 1 1" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--131.OPS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing Install per manufacturers details. For use in HVHZ Zones. 11651.4 1" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.5 1" VersaLoc .032" Aluminum Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.6 1.5" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detais. For use in HVHZ Zones. 11651.7 1.5" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Description Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail-signe .pd Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 1 R3 0325vCrimp 15-32Piywood NonH £igned.R4if Created by Independent Third Party: Yes Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Piyv Installation Instructions FL11651 R3 11 FL11651 2 R3 Metal Roof Panel Detail-sigr OAJ Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15- 32Plywood NonHVHZ-signed pdf Created by Independent Third Party: Yes 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail-signed.pd Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 3 R3 124GuIfSnap 17 1 - 32PIy-w-q HVHZ-signed.p-if Created by Independent Third Party: Yes 1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Installation Instructions--�___..._�._.___ FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail-sionn ,p-d Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 4 R3 24Versaloc SR 16.5 15- 1 plywood HVHZ-sioned,p, cif Created by Independent Third Party: Yes i" VersaLoc min .032" Aluminum over 15/32" Plywood w� Instailation Instructions FL11651 R3 II FLi1651 5 R3 Metal Roof Panel Detail-signed,pi Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports l FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc SR 16 15- 32Piywood HVHZ-Signed.p-df Created by Independent Third Party: Yes 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Installation Instructions } FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail-signed.od Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 6 R3 1.5 24GuIfSnap 16 is- 32P(ywood HVHZ-signe p-d Created by Independent Third Party: Yes ^1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15132" Plywood Installation Instructions FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail-signed.pdd Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.8 i 2" 24ga. MegaLoc Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.SPSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.9 24 Ga. Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-96.7PSF Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf @ 5-1/8" O.C. fastener spacing.-121.75 psf @ 5-1/8" fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.10 124 Ga. Gulf Seam Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.SPSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.11 124 Ga. Gulf Seam Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones 11651.12 126 Ga. 5V Crimp Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -1O8.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.13 26 Ga. 5V Crimp Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.PSF Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ 16" o.c. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. 11651.14 126 Ga. SV Crimp Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.15126 Ga. Gulf Lok Limits of Use Approved for use in HVHZ: Yes Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15- 2Plywood HVHZ-signed.pdf Created by Independent Third Party: Yes Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail-signe .pd Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651. R3 AE_FL11651.8_R3 24VersaLoc 18 15- J?Pjywood NonHVH2-signnd pdf Created by Independent Third Party: Yes Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Installation Instructions FL11651 R3 1I FL11651 9 R3 Metal Roof Panel Detail-signed.0 Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651.4_R3 24GulfLok 16 15- 2P ywood NonHVHZ-signe .pdf Created by Independent Third Party: Yes Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins ov 15/32" Plywood :Installation instructions FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail-signed.o Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15- 32Plywood NonHVHZ-sigpgd.pdf Created by Independent Third Party: Yes Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 it R3 Metal Roof Panel Detail-signed.g Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 it R3 24GulfSeam 18 15- 32Plywood NonHVHZ-signed pdf Created by Independent Third Party: Yes Min 26 Ga. SV Crimp Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail-sign,q Verified By: Dan Kuhn, P.E. 75519 Created by independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 12 R3 265vCrimp 15-32Plvwood HVHZ Slgneddf .o Created by Independent Third Party: Yes Min 26 Ga. 5V Crimp over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail-signe R Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 13 R3 265vCrimp 15-32Piywood NonH ,gne .pdf Created by Independent Third Party: Yes Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail ig amp Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 14 R3 265vCrimp 1x4 15- 32Plywood NonHVHZ-signed,pdf Created by Independent Third Party: Yes Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood _ Installation Instructions FL11651 R3 II FL11651 15 R3 Meta( Roof Panel Detail-signned.p Approved for use outside HVHZ: Yes Verified By: Dan Kuhn, P.E. 75519 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-161.OPSF 1 Evaluation Reports Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" FL11651 R3 AE FL11651 15 R3 26GulfLok 16 15-32Plywoo H\j spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing. Install per Ligned,p- f manufacturers details. For use in HVHZ Zones. 1 Created by Independent Third Party: Yes 11651.16 126 Ga. Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.SPSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.17 126 Ga. GulfPBR Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details. Not for use in HVHZ 11651.18 i 26 Ga. GulfPBR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure. +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf @ 12" fastener spacing. Install per manufacturer's details. For use in HVHZ Zones 11651.19 126 Ga. GulfPBR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. For use in HVHZ Zones. 11651.20 {26 Ga. GulfPBR Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure +N/A/-151.7PSF Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf @ 12" fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood installation Instructions i FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail-signedp Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 16 R3 26GulfLok 16 IS- 322PIywood NonHVHZ-signe .pff Created by Independent Third Party: Yes Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood i Installation Instructions FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail-signed.p Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 17 R3 26GulfPBR 15-32Piywood NonH' sig tie spy Created by Independent Third Party: Yes Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions—._._.....__ FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail-sigrn p Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15-32Plywood 1- 1igl>Q&LPAf Created by Independent Third Party: Yes Min 26 Ga. GulfPBR over 15/32" Plywood Installation Instructions FL_1_1651 R3 II FL11651 19 R3 Metal Roof Panel Detail-signe .p Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 19 R3 26GulfPBR 15-32PIl wood HVHZ !i:igng�Lpdf Created by Independent Third Party: Yes Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail -signed p Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 15- 32PIlywood NonHVHZ-signed ppff Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CopyLight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not se electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuar Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email adds they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wi: supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a liter under Chapter 455, F.S., please click here . Product Approval Accepts: eC e6 CM Credit Card Safe ASSEMBLY A/B 16" COVERAGE (1) # 10-12 X 1" TYPE A PANCAKE SPACING: SEE UPLIFT TABLE ASSEMBLY C 1/4"-5/16" DIAMETER BEAD OF TITEBOND SEALANT FL# 11651.9 R3 * OCTOBER 5, 2017 (1) #10-12 X 1" TYPE A PANCAKE SPACING: SEE UPLIFT TABLE ASSEMBLY D W/CLIP — GulfLok T" CLIP 24 GA.— (1) #10-12 X 1" TYPE A PANCAKE SPACING: SEE UPLIFT TABLE I % t % I I I I I t I , , " •tEEL S ,, ,�k C E IV Z*: No. 7,5519 0 STATE OF 0 R I ID '%O/VAL "' * i % t'% 0/051201 . '.l a of H X , Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC , Il 1, 111 111 111 ;i1i'l � jqg ill: " I , jj� I I I �1:' ;; Florida Product Approval #11651.9 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Valiclator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 11651.9 R3 * OCTOBER 5, 2017 LLC. J C E /V Z*: No. 75519 z STATE OF �0- R 19 '0"01VAL'r--t0,%% , , , , " I - , - li� 1'i0/0'5'/20:L7 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfLokTM, 7/8" Nailstrip Roof Panel, Minimum 24 Ga. Steel, Maximum 16" Coverage, Roof panel restrained with fasteners into minimum '$%2" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 24 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.0235" Minimum Width: 16" Coverage Maximum Female Rib: 7/8" Tall Male Rib: 3/ " Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: 24 Ga. Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only, where required design pressures exceed-121.75 psf. Panel Fastener: Through Panel Slot: (1) #10-12x1 " Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design uplift Pressures: Table "A" Maximum Design Pressures µ�0. IM -; Maximum Design Pressures 81.75 psf 96.75 psf -121.75 psf -161 psf bE' vJ"� _ 'C.;a4'z r'�'k'y i hn'.a k:' `Ng+ :+^ x•{*_'.w IN � c. �. ," ,.. 4*tA'. `�"`� xi�",f ��. �:�' ��<`r a, .,x2 .t"'.s„"°q^'�. m=,.t -_. Sealant No No Yes No ,� AN Y *Design Pressure includes a Safety Factor = 2.0. FL# 11651.9 R3 + OCTOBER 5, 2017 Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0089T-05 Dated 06/2005 2. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0301 T 10A-C, Dated 07/26/2013 3, TAS 125 Architectural Testing, Inc. (FBC Organization # TST-1527) Report No. B9000.01-450-18, Dated 12/12/2012 4. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) Q Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL# 11651.9 R3 • OCTOBER 5, 2017 /' ■ am 11:1 _. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.9 R3 • OCTOBER 5, 2017 AOM AO"' I & V2 X ,, ENGINEER LOAD TABLE: 24 Ga. Gulf LokTM 16" Wide Roof Panel over 15/32" Plywood 4 Q'ff '2110 M'411'a �,z 't Owl AN INV, WE NO' 41 4- 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE (MIN. 1/4" (MIN. 15/32-) ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPEED Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING =0 a ffis "a ZONE (1) #10-1120" PLYCDWOX OD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A 5 SW 1.) PANEL DESCRIPTION: GULFLOKTM, MIN. 24 GA, 7/8" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM. 2.) PANEL FASTENER: (1) #10-1 2X1 " PANCAKE TYPE A, 1/4" MIN. PENETRATION THROUGH PLYWOOD. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 81.75 PSF AT 101/4" O.C. ASSEMBLY A, 96.75 PSF AT 51/8" O.C. ASSEMBLY B, -121.75 PSF AT 51/a" O.C. WITH SEALANT ASSEMBLY C, -161 PSF AT 51/s" O.C. WITH CLIP ASSEMBLY D. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING & TESTING. 4.) PLYWOOD DECKING: MIN.'5/32" THICK, APA RATED PLYWOOD, GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. UID prv%r 3 Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or 3 feet. ASSEMBLY A/B 16" COVERAGE (1)#10-12 X 1" TYPE A PANCAKE------/ SPACING: SEE UPLIFT TABLE Aqqf=KARI Y r. I/4"-5/W DIAMETER BEAD OFTITEBOND SEALANT—­ #10-12 X V TYPE A PANCAKE—­/4 SPACING: SEE UPLIFT TABLE ASSEMBLY D W/CLIP GutfLok" CUP 24 GA SPACING: SEE UPLIFT TABLE