HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
ProjectName: CROWELL & RAUSCH RESIDENCE
BuilderName:
Street: 2711 S. 19th ST.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermilNumber:
Owner: MANSUETA CROWELL & THOMAS RAUSCH
Jurisdiction: 6611000
Designi-ocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1800.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame -Steel, Exterior
R=30.0 1485.0011
b. Frame -Wood, Adjacent
R=11.0 315.00 ft2
3. Number of units, if multiple family 1
c. WA
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10.Ceiling Types (2088.0 scift.)
Insulation Area
5. Is thisaworst rase? No
a. UnderAtlic(Vented)
R=38.0 2088.00 ft'
6. Conditioned floorarea above grade(ft2) 2088
b. N/A
R= - IF
Conditioned floorarea below grade(ft� 0
c. N/A
R= ft'
11. Ducts
R 112
7. Windows (107.5 sqR) Description Area
a. Sup: Attic, Ret: Attic, AH: UTILITY
6 175
a. U-Factor: Sgl, U=0.65 107.50 ft'
SHGC: SHGC=0.25
b. U-Factor: N/A ft'
12. Cooling systems
kBtuthr Efficiency
SHGC:
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft'
SHGC: -
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area WeightedAverage Overhang Depth: - 5.258 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap:509allons
B. Floor Types (2088.0 s ft. Insulation Area
4 )
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2088.00 ft2
b. Conservationfealures
b. N/A R= ft'
None
c. NIA R= I'
15. Credits
None
Glass/Floor Area: 0.051 Total Proposed Modified Loads: 57.04
PASS
Total Baseline Loads: 58.50
I hereby certify that the plans and specifications covered by
in the Florida Energy
Review of the plans and1�Slq
by this
this calculation are compliance with
specifications covered
Code.
calculation indicates compliance
with the Florida Energy Code.
sow 4 ¢
PREPARF�jD BY: �
DATE: J-26-20 O
Before construction is completed
this building will be inspected for
compliance with Section 553.908
�, - " _>
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OD11rE
OWNER/AGENT
BUILDING OFFICIAL:
DATE: 3/26/20
DATE:
M
J�•
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: CROWELL & RAUSCH RESI Bedrooms:.
3
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 2088
Lot#
Owner Name: MANSUETA CROWELL&TH
Total Stories:
1
Block/Subdivision:
#of Units: 1
Worst Case:
No
PlatBook:
BuilderName:
RotateAngle:
0
Street:
2711 S. 19th ST.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie'
Jurisdiction: 6611000
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design DailyTemp
V Design Location
TMY Site
97.5 %
2.5%
Winter
Summer DegreeDays Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
2088 20462.4
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 UTILITY
125 1225
No
0
1 No
Yes
Yes
2 M BATH
108 1058.4
No
0
1 Yes
Yes
Yes
3 WIC
108 1058.4
No
0
1 Yes
Yes
Yes
4 MASTER BEDROO
253 2479.4
No
0
1
1 Yes
Yes
Yes
5 KITCHEN
443 4341.4
Yes
0
1 Yes
Yes
Yes
6 LIVING
602 5899.6
No
4
1 Yes
Yes
Yes
7 BEDROOM 2
182 1783.6
No
0
1
1 Yes
Yes
Yes
8 BATH
85 833
No
0
1 Yes
Yes
Yes
9 BEDROOM 1
182 1783.6
No
0
1
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
Joist R-Value •
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
UTILITY 1 ft
0
126 ft2
----
0 '1
0
2 Slab -On -Grade Edge Insulation
M BATH 9ft
0
'108 ft.
----
0 1
0
- 3Slab-On-Grade Edge Insulation
WIC 21 If
0
108 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulation
MASTER BEDRO 14 It
0
252 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulation
KITCHEN 39 It
0
443 112
----
0 1
0
6 Slab -On -Grade Edge Insulation
LIVING 32If
0
_ 602 ft2
-
0 1
0
7 Slab -On -Grade Edge Insulation
BEDROOM 27 It
0
182 ft2
----
0 1
0
3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType
Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile
Wood Carpel
8 Slab -On -Grade Edge Insulation
BATH 9ft
0
85 ft'
____
0
1
0
9 Slab -On -Grade Edge Insulation
BEDROOMI 14 It
0
182 ft'
____
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 2200 ft2
0 ft2 Unfinishe
N
0.5
No 0.7
No 0
18.4
ATTIC
/
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Fullattic
Vented
150
2088 ft2
N
N
CEILING
#
CeilingType
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
UnderAffic(Vented)
UTILITY
38
Blown
126 ft2
0.1
Wood
2
UnderAttic(Vented)
M BATH
38
Blown
108 ft'
0.1
Wood
3
UnderAttic(Vented)
WIC
38
Blown
108 ft2
0.1
Wood
4
UnderAttic(Vented)
MASTER BEDRO
38
Blown
252 ft2
0.1
Wood
5
UnderAttic(Vented)
KITCHEN
38
Blown
443 ft2
0.1
Wood
6
UnderAftic(Vented)
LIVING
38
Blown
602 ft2
0.1
Wood
7
UnderAltic(Vented)
BEDROOM
38
Blown
182 ft2
0.1
Wood
8
UnderAttic(Vented)
BATH
38
Blown
85 ft2
0.1
Wood
9
UnderAttic(Vented)
BEDROOM 1
38
Blown
182 ft2
0.1
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing
Solar
Below
%
_ 1
BE
Exterior Frame -Steel
M BATH
30 9
0 9
0
81.0 ft2
0
0.25
0.4
0
2
NE
Exterior Frame -Steel
WIC
30 12
0 9
0
108.0 ft2
0
0.25
0.4
0
_ 3
BE
Exterior Frame -Steel
WIC
30 9
0 9
0
81.0 ft'
0
0.25
0.4
0
_4
NE
Exterior Frame - Steel
MASTER BE
30 14
0 9
0
126.0 ft2
0
0.25
0.4
0
5
NE
Exterior Frame -Steel
KITCHEN
30 34
0 9
0
306.0 fie
0
0.25
0.4
0
6
NW
Exterior Frame -Steel
KITCHEN
30 5
0 9
0
45.0 ft2
0
0.25
0.4
0
_ 7
SW
Exterior Frame -Steel
LIVING
30 32
0 9
0
288.0 ft'
0
0.25
0.4
0
8
SW
Exterior Frame -Steel
BEDROOM
30 14
0 9
0
126.0 112
0
0.25
0.4
0
9
NW
Exterior Frame -Steel
BEDROOM
30 13
0 9
0
117.0 ft2
0
0.25
0.4
0
10
NE
Exterior Frame - Steel
BATH
30 1
0 9
0
9.0 IF
0
0.25
0.4
0
11
NW
Exterior Frame -Steel
BATH
30 8
0 9
0
72.0 ft2
0
0.25
0.4
0
12
NW
Exterior Frame -Steel
BEDROOM
30 14
0 9
0
126.0 ft2
0
0.25
0.4
0
Y3
N
Garage Frame -Wood
BEDROOM
11 35
9
315.0 1112
0.23
0.4
0
3126/20208:53 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition(2017) Compliant Software Page 3of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt
DoorType
Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
2
NE
SW
Insulated
Insulated
KITCHEN
LIVING
None
None,
.39 6
.39 3
6 8
6 8
40 ft'
20 ft'
WINDOWS
Orientation shown isthe entered, Proposed orientation.
/
V #
Wall
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
IntShade
Screening
1
2
3
4
5
6
7
8
NE 4 Metal
NE 5 Metal
NE 5 Metal
SW 7 Metal
SW 8 Metal
NW 9 Metal
NW 11 Metal
NW 12 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 026 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
12.0 ft' 10 ft 0 in 0 ft 0 in
7.8 ft' 1 It 0 in 0 ft 0 in
7.8 W 10 it 0 in 0 ft 0 in
40.0 ft' 8 If 0 in 0 It 0 in
12.0 ft' 1 1110 in 2 ft 5 in
12.0 ft' 1 1110 in 4 ft 0 in
4.0 ft' 1 ft 0 in 6 ft 7 in
12.0 ft' 1 ft 0 in 4 ft 0 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
FloorArea
CeilingArea
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
330 ft'
330 ft'
37 ft
9 If
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000311
1705.2 93.61 176.05 .117
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtuRv
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
CentralUnit/
Split
Single SEER: 16
29.4 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type
SubTpe
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
UTILITY
0.95 50 gal 60.9 gal 120deg
None
3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC Bin Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert# CompanyName
System Model# CollectorModel# Area Volume
FEF
None None
ft'
DUCTS
/ —Supply--
—Return—
Air
CFM25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6
175 ft'
Attic
65 ft'
DefaullLeakage UTILITY
(Default) c(Default) c
1 1
TEMPERATURES
Programabl[eTT'jhermostat N
Ceiling Fans:
Cooling
Jan Feb
r[X']
I[X
Dec
Venting HFeb
mMar
Apr
May
[�(
Jun
Aug
Sep
�[x1f
Oct
Nov
Dec
[ ]Jan
[ Jul
[
I^1
Thermostat5chedule: HERS 2006 Reference
Hours
Schedule -Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling(WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Heating(WD) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating(WEH) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 fl'
Oft
0.3
UTILITY
Default(8 lbslsq.ft.
ft'
ft
0.3
M BATH
Default(8lbs/sq.ft.
ft'
It
0.3
WIC
Default(8lbslsq.ft.
ft'
It
0.3
MASTER BEDROO
Default(Blbslsq.ft.
ft'
It
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
LIVING
Default(8lbs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft'
ft
0.3
BATH -
Detault 8lbs/s .ft.
ft'
It
0.3
BEDROOM 1
3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts. R
6.0
c) AHU location UTILITY
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
29.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2088
d) Room unittPTAC EER
e) Other
7. Windows, type and area
.
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
ET
c) Area
7c.
107.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
81b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
gb.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
30.0
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
f) Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
38.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 2711 S. 19th ST. City/FL Zip: FT. PIERCE, FL
3/26/2020 8:53:29 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 5th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CROWELL & RAUSCH RESIDENCE Builder Name:
Street: 2711 S. 191h ST. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. MANSUETA CROWELL & THOMAS RAUSCH Jurisdiction: 6611000
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed:
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the lop plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarderwith overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on ,
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
_
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Eljectricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
WAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between fire sprinkler cover nlateq and wall celfinog.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
. r
yENT1LAtON gAL'cULAm6NB:
Aft ventilation occurs through vented soffit on the sidewag overhangs. Per,IBQ Se
the net free ventilatng area'shall not be less thaw ,1/300`ofthe area of the space ve
(because a proper vapor barrier, `s.used; see.exception). Below are the calculation
correspond to:venhlation requirements. These calculations are for the south'end of
and. are given the worst case that is present _
vented ridge cap; 18 sq. in. of netfree area per lin. ft
1 ft sfdewall Soffitis instaWd in1 it lengths. ;.The pattern is 1'solid section,
`overhang;; 4 vented sections.The vented sectonshave i2625'sq.;inof
'area per lin. ft..perside. since the vented ridge cap controls
overhangs will only ventilate-1 B sq. m. per ft (9 sq. in. per side
For the 40' wide build ng having a typical 5:•sectan:
NET_FREE_AREA:=.�2-1tt $in2, -(58) NET_FREE_AREA=3.25,$?
FREE -AREA -REQUIRED :=, (5ft)(40ft)• I FREE _AREA_REQUIRED='0:67•ft2
"0