Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method ProjectName: CROWELL & RAUSCH RESIDENCE BuilderName: Street: 2711 S. 19th ST. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermilNumber: Owner: MANSUETA CROWELL & THOMAS RAUSCH Jurisdiction: 6611000 Designi-ocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1800.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Steel, Exterior R=30.0 1485.0011 b. Frame -Wood, Adjacent R=11.0 315.00 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types (2088.0 scift.) Insulation Area 5. Is thisaworst rase? No a. UnderAtlic(Vented) R=38.0 2088.00 ft' 6. Conditioned floorarea above grade(ft2) 2088 b. N/A R= - IF Conditioned floorarea below grade(ft� 0 c. N/A R= ft' 11. Ducts R 112 7. Windows (107.5 sqR) Description Area a. Sup: Attic, Ret: Attic, AH: UTILITY 6 175 a. U-Factor: Sgl, U=0.65 107.50 ft' SHGC: SHGC=0.25 b. U-Factor: N/A ft' 12. Cooling systems kBtuthr Efficiency SHGC: a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft' SHGC: - 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area WeightedAverage Overhang Depth: - 5.258 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap:509allons B. Floor Types (2088.0 s ft. Insulation Area 4 ) EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2088.00 ft2 b. Conservationfealures b. N/A R= ft' None c. NIA R= I' 15. Credits None Glass/Floor Area: 0.051 Total Proposed Modified Loads: 57.04 PASS Total Baseline Loads: 58.50 I hereby certify that the plans and specifications covered by in the Florida Energy Review of the plans and1�Slq by this this calculation are compliance with specifications covered Code. calculation indicates compliance with the Florida Energy Code. sow 4 ¢ PREPARF�jD BY: � DATE: J-26-20 O Before construction is completed this building will be inspected for compliance with Section 553.908 �, - " _> I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OD11rE OWNER/AGENT BUILDING OFFICIAL: DATE: 3/26/20 DATE: M J�• - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CROWELL & RAUSCH RESI Bedrooms:. 3 Address Type: StreetAddress Building Type: User ConditionedArea: 2088 Lot# Owner Name: MANSUETA CROWELL&TH Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 2711 S. 19th ST. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie' Jurisdiction: 6611000 Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.5% Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2088 20462.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 UTILITY 125 1225 No 0 1 No Yes Yes 2 M BATH 108 1058.4 No 0 1 Yes Yes Yes 3 WIC 108 1058.4 No 0 1 Yes Yes Yes 4 MASTER BEDROO 253 2479.4 No 0 1 1 Yes Yes Yes 5 KITCHEN 443 4341.4 Yes 0 1 Yes Yes Yes 6 LIVING 602 5899.6 No 4 1 Yes Yes Yes 7 BEDROOM 2 182 1783.6 No 0 1 1 Yes Yes Yes 8 BATH 85 833 No 0 1 Yes Yes Yes 9 BEDROOM 1 182 1783.6 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value • Tile Wood Carpet 1 Slab -On -Grade Edge Insulation UTILITY 1 ft 0 126 ft2 ---- 0 '1 0 2 Slab -On -Grade Edge Insulation M BATH 9ft 0 '108 ft. ---- 0 1 0 - 3Slab-On-Grade Edge Insulation WIC 21 If 0 108 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulation MASTER BEDRO 14 It 0 252 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulation KITCHEN 39 It 0 443 112 ---- 0 1 0 6 Slab -On -Grade Edge Insulation LIVING 32If 0 _ 602 ft2 - 0 1 0 7 Slab -On -Grade Edge Insulation BEDROOM 27 It 0 182 ft2 ---- 0 1 0 3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpel 8 Slab -On -Grade Edge Insulation BATH 9ft 0 85 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulation BEDROOMI 14 It 0 182 ft' ____ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2200 ft2 0 ft2 Unfinishe N 0.5 No 0.7 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fullattic Vented 150 2088 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAffic(Vented) UTILITY 38 Blown 126 ft2 0.1 Wood 2 UnderAttic(Vented) M BATH 38 Blown 108 ft' 0.1 Wood 3 UnderAttic(Vented) WIC 38 Blown 108 ft2 0.1 Wood 4 UnderAttic(Vented) MASTER BEDRO 38 Blown 252 ft2 0.1 Wood 5 UnderAttic(Vented) KITCHEN 38 Blown 443 ft2 0.1 Wood 6 UnderAftic(Vented) LIVING 38 Blown 602 ft2 0.1 Wood 7 UnderAltic(Vented) BEDROOM 38 Blown 182 ft2 0.1 Wood 8 UnderAttic(Vented) BATH 38 Blown 85 ft2 0.1 Wood 9 UnderAttic(Vented) BEDROOM 1 38 Blown 182 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below % _ 1 BE Exterior Frame -Steel M BATH 30 9 0 9 0 81.0 ft2 0 0.25 0.4 0 2 NE Exterior Frame -Steel WIC 30 12 0 9 0 108.0 ft2 0 0.25 0.4 0 _ 3 BE Exterior Frame -Steel WIC 30 9 0 9 0 81.0 ft' 0 0.25 0.4 0 _4 NE Exterior Frame - Steel MASTER BE 30 14 0 9 0 126.0 ft2 0 0.25 0.4 0 5 NE Exterior Frame -Steel KITCHEN 30 34 0 9 0 306.0 fie 0 0.25 0.4 0 6 NW Exterior Frame -Steel KITCHEN 30 5 0 9 0 45.0 ft2 0 0.25 0.4 0 _ 7 SW Exterior Frame -Steel LIVING 30 32 0 9 0 288.0 ft' 0 0.25 0.4 0 8 SW Exterior Frame -Steel BEDROOM 30 14 0 9 0 126.0 112 0 0.25 0.4 0 9 NW Exterior Frame -Steel BEDROOM 30 13 0 9 0 117.0 ft2 0 0.25 0.4 0 10 NE Exterior Frame - Steel BATH 30 1 0 9 0 9.0 IF 0 0.25 0.4 0 11 NW Exterior Frame -Steel BATH 30 8 0 9 0 72.0 ft2 0 0.25 0.4 0 12 NW Exterior Frame -Steel BEDROOM 30 14 0 9 0 126.0 ft2 0 0.25 0.4 0 Y3 N Garage Frame -Wood BEDROOM 11 35 9 315.0 1112 0.23 0.4 0 3126/20208:53 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition(2017) Compliant Software Page 3of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt DoorType Space Storms U-Value Width Ft In Height Ft In Area 1 2 NE SW Insulated Insulated KITCHEN LIVING None None, .39 6 .39 3 6 8 6 8 40 ft' 20 ft' WINDOWS Orientation shown isthe entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation IntShade Screening 1 2 3 4 5 6 7 8 NE 4 Metal NE 5 Metal NE 5 Metal SW 7 Metal SW 8 Metal NW 9 Metal NW 11 Metal NW 12 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes Yes Yes Yes Yes Yes Yes Yes 0.65 026 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 12.0 ft' 10 ft 0 in 0 ft 0 in 7.8 ft' 1 It 0 in 0 ft 0 in 7.8 W 10 it 0 in 0 ft 0 in 40.0 ft' 8 If 0 in 0 It 0 in 12.0 ft' 1 1110 in 2 ft 5 in 12.0 ft' 1 1110 in 4 ft 0 in 4.0 ft' 1 ft 0 in 6 ft 7 in 12.0 ft' 1 ft 0 in 4 ft 0 in None None None None None None None None None None None None None None None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 330 ft' 330 ft' 37 ft 9 If 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000311 1705.2 93.61 176.05 .117 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtuRv 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER: 16 29.4 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.95 50 gal 60.9 gal 120deg None 3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC Bin Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert# CompanyName System Model# CollectorModel# Area Volume FEF None None ft' DUCTS / —Supply-- —Return— Air CFM25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft' Attic 65 ft' DefaullLeakage UTILITY (Default) c(Default) c 1 1 TEMPERATURES Programabl[eTT'jhermostat N Ceiling Fans: Cooling Jan Feb r[X'] I[X Dec Venting HFeb mMar Apr May [�( Jun Aug Sep �[x1f Oct Nov Dec [ ]Jan [ Jul [ I^1 Thermostat5chedule: HERS 2006 Reference Hours Schedule -Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 fl' Oft 0.3 UTILITY Default(8 lbslsq.ft. ft' ft 0.3 M BATH Default(8lbs/sq.ft. ft' It 0.3 WIC Default(8lbslsq.ft. ft' It 0.3 MASTER BEDROO Default(Blbslsq.ft. ft' It 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 LIVING Default(8lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft' ft 0.3 BATH - Detault 8lbs/s .ft. ft' It 0.3 BEDROOM 1 3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts. R 6.0 c) AHU location UTILITY 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2088 d) Room unittPTAC EER e) Other 7. Windows, type and area . a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity ET c) Area 7c. 107.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) gb. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 30.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. f) Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 38.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 2711 S. 19th ST. City/FL Zip: FT. PIERCE, FL 3/26/2020 8:53:29 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 5th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CROWELL & RAUSCH RESIDENCE Builder Name: Street: 2711 S. 191h ST. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner. MANSUETA CROWELL & THOMAS RAUSCH Jurisdiction: 6611000 = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed: Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the lop plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarderwith overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on , installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring _ and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Eljectricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots WAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire sprinkler cover nlateq and wall celfinog. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/26/2020 8:53 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 . r yENT1LAtON gAL'cULAm6NB: Aft ventilation occurs through vented soffit on the sidewag overhangs. Per,IBQ Se the net free ventilatng area'shall not be less thaw ,1/300`ofthe area of the space ve (because a proper vapor barrier, `s.used; see.exception). Below are the calculation correspond to:venhlation requirements. These calculations are for the south'end of and. are given the worst case that is present _ vented ridge cap; 18 sq. in. of netfree area per lin. ft 1 ft sfdewall Soffitis instaWd in1 it lengths. ;.The pattern is 1'solid section, `overhang;; 4 vented sections.The vented sectonshave i2625'sq.;inof 'area per lin. ft..perside. since the vented ridge cap controls overhangs will only ventilate-1 B sq. m. per ft (9 sq. in. per side For the 40' wide build ng having a typical 5:•sectan: NET_FREE_AREA:=.�2-1tt $in2, -(58) NET_FREE_AREA=3.25,$? FREE -AREA -REQUIRED :=, (5ft)(40ft)• I FREE _AREA_REQUIRED='0:67•ft2 "0