MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE(NOA)►'�►�w.nFinufidade.ea4lrrnnnni}
Copper River Shake and Shingle LTD.
9550 2881h St.
Maple Ridge, B.C. V2W1L1
Canada
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Wood Shakes and Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 14-0107.05 and consists of pages I through 3.
The submitted documentation was reviewed by Freddy Semino 0
NOA No.: 18-0416.02
Expiration Date: 05/31/23
Approval Date: 05/31/18
Page 1 of 3
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Wood Shingles and Shakes
Materials
Wood
Duch Tyne:
Wood
SCOPE
This approves roofing system using wood shingles and shakes as manufactured by Copper River Shake and Shingle
LTD; and as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code,
high Velocity Hurricane Zone.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Snecirtentions
Resawn Cedar Shakes
Widths
= 4" - 14"
TAS 110
Length =
18 - 24"
Tapersawn Cedar Shakes
Widths
= 4" - 14"
TAS 110
Length =
18 - 24"
Wood Shingles
Widths = 4" - 14"
TAS 110
Length =
16"- 24"
MANUFACTURING LOCATION
1. Maple Ridge, British Colombia
Product Description
No. 1 grade hand split resawn, fire retardant,
preservative treated or natural cedar shakes.
No. 1 grade, fire retardant, preservative treated
or natural cedar shakes.
No. I grade western red cedar, fire retardant,
preservative treated or natural cedar shingles.
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test_Nume/Report
Date
PRI Asphalt Technologies
BCSS-001-02-01
TAS- 100
12/12/06
PRI Asphalt Technologies
BCSS-002-02-01
TAS-100
12/13/06
PRI Asphalt Technologies
BCSS-003-02-01
ASTM D-3462
05/02/07
(Nail Pull Through)
PRI Asphalt Technologies
CRSS-001-02-01
TAS-100
ASTM D-3462
04/09/18
(Nail Pull Through)
PRI Asphalt Technologies
CRSS-001-02-02
TAS-100
04/09/18
ASTM D-3462
(Nail Pull Through)
NOA No.: 18-0416.02
MmMEa4�E eounrrr Expiration Date: 05/31/23
Approval Date: 05/31/18
Page 2 of 3
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable Building Code
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Copper River Shake and Shingle LTD. Wood Shakes and Shingles and its components shall be installed in
strict compliance with Roofing Application Standard 130.
Fastener Pull Through Resistance
Description Maximum Pull Force lbs.
Resawn and Ta ersawn Wood Shake 170
Wood Shingle 132
LABELING
1. Shingle/Shake Bundles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade
County Product Control Approved".
■.1 014slolUklio
APPROVED
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
l .1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
END OF THIS ACCEPTANCE
NOA No.: 18-0416.02
Expiration Date: 05/31/23
Approval Date: 05/31/18
Page 3 of 3
MIAMI•[aAl]E
;11
L�1'll�l
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
w►vw.miamidnde. nvleennom
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino. U
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Cate Qorv: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Polystick IR-Xe
65' x 3'3 3/8"
ASTM D 1970
A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
6P x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location #2
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x 3'3 3/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location #1 & #2
underlayment.
Polystick TU P
32'10" x 3'3-3/8"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a the roof underlayment.
Polystick TU Plus
65' x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location # 1 & #2
Polystick MTS
65'8" x 3'3 '/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick NITS Plus
65'8" x 3'3-3/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 %"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
'Pest Agency
Test Identifier
Test Naine/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.1I
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
' NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing, and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations Days
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MIAMMAD, COUNTYF329,11402 Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick NITS and Polystick NITS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
NITS
S6 G
TU P, Tile Pro,
TU Max
NITS Plus
NITS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick NITS which shall be loaded onto battens.
v
M.
0
w
N
POL`anCKTU Plus
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and 410.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT
SAINT LUCIE COUNTY
FILE # 4701057 04/22/2020 08:55:31 AM
OR BOOK 4411 PAGE 1831 - 1831 Doc Type: NC
AFTER RECORD] NG-RETURN TO: RECORDING: $10.00
PERMIT NUMBER: I — Iln.',p;,-i— 0
NOTICE OF COMMENCEMENT
The undersigned hereby given notice that improvement wilt be made to certain real property, and in accordance with Chapter 713,
Florida statutes the following information is provided in the Notice of commencement.
l • DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 1414-601-0000-000-9
SUBDIVISION BLOCK TRACT LOT BLD.G UNIT
14/34S/40EM Northh_ATart Pierce, L 3—
2. GENERAL DESCRIPTION OF IMPROVEMENT: Remove wood shingles, nail wood deck, install wood shingles.
3. OWNER INFORMATION: a, Name BRYN MAWR Ocean Towers Condominium Association Inc
b. Address 835 20th Street, Vera Beach,32960 c. interest in property
d. Name and address of fee simple titleholder (if other than
4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: The Roof Authority, Inc
6771 North Old Dixie Highway, Fort Pierce, FL 34946 (772) 468-7870
5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT:
6, LENDER'S NAME, ADDRESS AND PHONE NUMBER:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (])(a) 7., Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section
713.13 (1)(b), Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is
specified) , 20
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I SECTION 711 j ,_Sz RIDA ST,AIIITI .S, AND CAN RLMILT
Signature of Owner or Print Name and Provide Signatory's Title/Office
Owner's Authorized Officer/Director/Partner/Manager
State of Florida / 1
County of 1 t R \r/Brr1 I p
The fAoing Instrument was acknowledged before me this J day of 06 0 r I L 2CL
By� X O1C R S5 , as r
P! rr,e of pemn) (Type of nuth r ty...e.g. Owner, officer, trustee, attorney in fact)
For i l IW ( li)u.es .
(Name be party on behalf of whom instrument was executed) Personally Known or produced the following type of ID:
CbeLL'
JULIE BARRETT
otary Public •State of Florida
Conlmisslon � GG 243242
(Printed Name of Notary Public) (Si cure of Notary Public) (Sell) � Coma% Exolres Sep 28, 2022