HomeMy WebLinkAboutLot 3 Tarpon Flats Letter Corporate Headquarters 531 Codisco Way Sanford, Florida 32771 Statewide (888) 831-COOL (2665) Fax (407) 333-3853 www.Delair.com State Lic. CAC032448 January, 27 2020 ATTN: St. Lucie County, FL Dept. of Building & Code Regulation Division RE: Phoenix Homes Realty Inc. - Lot 3 Tarpon Flats The mechanical ventilation calculations as required by 2017 FBC Mechanical, 6th Edition Chapter 401.2 for Lot 31 Tarpon Flats are designed per code and shall follow these parameters as described as proposed in the 2017 FBC – Energy Conservation, 6th Edition Chapter 4, not to exceed .01 x CFA + 7.5 x(Number of Bedrooms +1): Living Square Footage: 1976 Number of Bedrooms: 3 +1 = 4 .01 x 1976 = 19.76 4 x 7.5 = 30 19.76 + 30 = 49.76 CFM This method is also within compliance with the simplified 2017 FBC M1507.3.3(1) Chart as listed below: Del-Air designed and installed a 6” diameter fresh air ventilation intake including mechanical damper, control, and shut off to handle code mechanical ventilation requirement, when a residential building’s envelope tests below 3ACH50. Sincerely,