HomeMy WebLinkAboutSewage PERMIT #:56-SF-2051226
APPLICATION #:AP1475827 _
STATE OF FLORIDA
~F •; . ,
� ,, �, •r. _�
DEPARTMENT OF HEALTH DATE PAID:
F �� ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM RECEIPT #:
u� DOCUMENT #:PR1321619
I
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: (Hang Blue Builders, Inc)
PROPERTY ADDRESS: 2802 Flotilla Ter Fort Pierce,FL 34949
LOT: 3 BLOCK: 6 SUBDIVISION: Coral Cove Beach
PROPERTY ID #: 1425-701-0158-000-2 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF; SECTION
381.0065; F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT ,GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO 'MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER ! FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 900 ] GALLONS / GPD Septic New CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [ 375 ] SQUARE FEET Drainfield New SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [X] STANDARD [ ] FILLED [ ] MOUND [ ]
I CONFIGURATION: EXI TRENCH [ ] BED [ ]
N
F LOCATION OF BENCHMARK:- Site BM set mag nail CL of road
I ELEVATION OF PROPOSED SYSTEM SITE [ 2.00 ] [ INCHES FT ] [ ABOVE BELOW]BENCHMARK/REFERENCE POINT
. E BOTTOM OF DRAINFIELD TO BE [ 14.00 ] [ INCHES FT ] [ABOVE BELOW BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED: [ 2.00] INCHES EXCAVATION REQUIRED: ] INCHES
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of j
O 300 gpd.
T
A
E
R
SPECIFICATIONS BY: Hunter A Collier TITLE- Environmental Specialist I
APPROVED BY: TITLE: Environmental Specialist I St.Lucie CRD
ureter A Collier
DATE ISSUED: 04/06/2020 EXPIRATION DATE: 10/06/2021
DH 4016, 08/09• (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, -FAC Pagel of 3
v 1.1.4 AP1475827 SE1270284
APPLICATION # A{�'{475827
STATE OF FLORIDA
DEPARTMENT OF HEALTH PERMIT # 56-SF-2051226
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
DOCUMENT # SE1270284
SITE EVALUATION AND SYSTEM SPECIFICATION
I,
1
Y US
APPLICANT,:P Harry Blue Builders, Inc
CONTRACTOR / AGENT:
LOT: 3 BLOCK: 6
SUBDIVISION: Coral Cove Beach ID#: 1425-701-0158-000-2
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [X ]YES [ ]NO NET USABLE AREA AVAILABLE: 0,22 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [RESIDENCES-TABLET / OTHER-TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 549.99 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SQFT
BENCHMARK/REFERENCE POINT LOCATION: Site BM Set mag nail CL Of road
ELEVATION OF PROPOSED SYSTEM SITE 2.00 L INCHES / FT ] [ ABOVE / BELOW ] BENCRMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT DITCHES/SWALES: 15 FT NORMALLY WET: [ ]YES ' [X]NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON-POTABLE: FT
BUILDING FOUNDATIONS: 8 FT PROPERTY LINES: 10 FT POTABLE WATER LINES: 43 FT
SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X NO 10 YEAR FLOODING? [ ]YES , [X]NO]
10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD
SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2
USDA SOIL SERIES:Canaveral fine sand, 0 to 5 perc USDA SOIL SERIES:Canaveral fine sand, 0 to 5 perc
Munsell#/Color Texture Depth Munsell#/Color Texture Depth
10YR 5/2 Sand 0 To 16 10YR 5/2 Sand 0 To 18
10YR 6/4 Sand 16 To 33 10YR 6/3 Sand 18 To 27
10YR 6/2 Sand 33 To 42 10YR 7/2 Sand 27 To 45
10YR 7/2 Sand 40 To 56 10YR 7/1 Sand 45 To 72
10YR 7/1 Sand 56 To 72
OBSERVED WATER TABLE: 56.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ]
ESTIMATED WET SEASON WATER TABLE ELEVATION: 40 INCHES [ ABOVE / BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: [ ]YES [X ]NO MOTTLING: [X ]YES [ ]NO DEPTH: 40.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [X] TRENCH [ ] BED [ ] OTHER (SPECIFY)
REMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soil borings. 10YR 7/2 stripping in 10YR 6/2 matrix>10%with diffuse boundaries starting
at 40"in SB1. SBI 2"above BM. S132 5"above BM.
SITE EVALUATED BY: 1 DATE: 03/30/2020
Collier,Hunter(Ttle:Environmental Specialist 1)(Florida Department of Health In SL L
DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated; 64E-6.001, FAC Page 3 of 4
AP1475627 EID2051226 v 1.0.2
anCz mu
STATE OF 'FLORIDA PERMIT NO.
4 DEPARTMENT OF HEALTH DATE PAID:
ONSITE 'SEWAGE TREATMENT AND DISPOSAL FEE PAID: $fir t�d
SYSTEM RECEIPT #:
pry`°°° '`�• APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
[f7 New System [ ] Existing System ( ] Holding Tank ,( ] Innovative
[ ]. Repair [ ] Abandonment [ J Temporary [ l
APPLICANT:
AGENT: y IK/ff� TELEPHONE: /
V -
MAILING ADDRESS: y . 1
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3) (m) OR 489.552, FLORIDA STATUTES, IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY 'INFORMATION /�Q /J
LOT: BLOCK: 4! SUBDIVISI.ON:Azz C06C t,fJ� SCF-(7� PLATTED:
PROPERTY ID #: ZONING. I/M OR EQUIVALENT: [ YIN ]
PROPERTY SIZE. ' 11,L- ACRES WATER SUPPLY: [ J PRIVATE PUBLIC X]<=2.000GPD [ 1>2000GPD
IS SEWER AVAILABLE AS PER, 381.0065, FS? [ Y/�! ] DISTANCE TO SEWER: FT
PROPERTY ADDRESS:
DIRECTIONS TO PROPERTY: � }'/'�/ /'. i}/ T2l-,YDL9
BUILDING INFORMATION �><RESIDSNTIAt [ 7 COMMERCIAL
Unit Type of No. of Building Commercial/Institutional System Design
No Establishment 'Bedrooms Area Sqft Table 1, :Chapter 64E-6, PAC
3
4
[ ] . Floor/Equipment Drains [ ] Other (Specify)
SIGNATURE: DATE- (442
i
DH 4015, 08/09 (Obsoletes previous- editions which may not be used)
Incorporated 64E-6.001, FAC Page 1 df4
i