1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND
BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD
LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS_ IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING
DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED
BY CARPORTS ANYWHERE, INC_, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS
ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2.
4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15.
5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE
RESPONSIBILITY OF THE OWNER.
6. ROOF AND WALL SHEATHING SECURED WITH #12-140" SELF -DRILLING SCREWS WITH SEAL WASHERS ® 6" 0_C_ MAX.
7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF -DRILLING SCREWS.
8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP.
9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH.
10. 12 GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL.
--------------- -----------------------------
i
,
i
i
i
i
I
L
-0"
SUB -GRADE SOILS:
-TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION
R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION
- INIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
-ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE
DESIGNED TO SLOPE AWAY FROM THE STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
-MINIMUM GRADE 40 STEEL
-REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
-THE REBAR IS BENT COLD
-THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED
6 -BAR DIAMETERS: AND
-REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT
EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL
CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
-COVER:
-2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY
IN CONTACT WITH SOIL OR WEATHER, AND 14" ELSEWHERE. REBAR EMBEDDED IN
GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE
GROUT, AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL.
REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING
GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO
EARTH OR WEATHER, AND 1j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR
WEATHER.
GALVANIZATION:
-METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY
EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153,
CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
J"x5A" EXPANSION ANCHOR WITHIN 6"
OF EACH POST/TRUSS ALONG SIDES
AND EVERY OTHER END -WALL POST
2" MIN.
`~12"
MINIMUM SOIL BEARING
CAPACITY 2,000 PSF(TYP.)
RAIL
2,500 PSI 4"
CONCRETE SLAB WITH
W.W.F. OR FIBER MES[
(2) #5 REBAR ® 6" O.C.
CONTINUOUS WITH MINIMUM
12" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
2 5" PLAN VIEW DOOR FRAMING
1 if J" RECESS
4
DOOR WIDT I
CARPORTS ANYWHERE
ELEVATION VIEW
DOOR FRAMING
" RECESS
•75"TOOR WIDT
4"
OPTIONAL ROLL—UP DOOR
CONCRETE SPLASH—GUARD RECESS
II -B
MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER
MESH) AND 12"x12" REINFORCED FOOTER PERIMETER 12"x12" REINFORCED FOOTER
--- -- - -- -
_________________________ ___________________________
-0"-
SWINGING
DOOR
ROLL -UP
DOOR
N
-0"
0'-
-0„ FRAME
------------------ DLTT-----
---------------FRAME----
'-0" OUT
0'-C
CODE VERSION
FEIC 2017 6th Editior
ASCE-7-10
ANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II -B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-165mph
ENCLOSURE PARTIALLY ENCLOSED/OPEN
INTERNAL PRESSURE COEFF. +/- 0.55/0.0
IMPORTANCE FACTOR 1.0
ROOF DEAD LOAD 10PSF
f� -0 ROOF LIVE LOAD 20PSF OR 3001b P.L.
FLOOR DEAD LOAD 10PSF
---------------- FLOOR LIVE LOAD 50PSF
i
"R"RATING OF WALLS, FLOO R,ROO F N/A
MODULES PER BUILDING 1
i
HURRICANE PROTECTION USAGE NO
HURRICANE SHELTER USAGE NO
SQUARE FOOTAGE 1,650 SQ. FT.
REV DESCRIPTON DATE BY
1 REDESIGNED LAYOUT 4/1/20 MTB
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
I' 55'L X 30'W X 12'H 11
QFlorida License #64608
Sheet: CA -1 OF 4
'1 //� ��`4
'J Ibj ���•f
—
I- c
,.
LLJ
4./
Matthew T Baldwin P E
QFlorida License #64608
Sheet: CA -1 OF 4
b
N
CARPORTSANYWHEIM
CODE INFORMATION
CODE VERSION FBC 2017 6th Edition
ASCE-7-10
MANUFACTURER CARPORTS ANYWHERE
BUILDING TYPE UTILITY STRUCTURE
CONSTRUCTION TYPE II -B
RISK CATEGORY I
FIRE PROTECTION NONE
FIRE SUPPRESSION SYSTEM NONE
OCCUPANCY UTILITY, U
WIND SPEED Vult-165mph
EXPOSURE B
ENCLOSURE PARTIALLY ENCLOSED/OPEN
INTERNAL PRESSURE COEFF. +/— 0.55/0.0
IMPORTANCE FACTOR 1.0
ROOF DEAD LOAD 1OPSF
3a'-0"
FRONT END WALL
ROOF LIVE LOAD 20PSF OR 3001b P.L.
FLOOR DEAD LOAD 1OPSF
FLOOR LIVE LOAD 50PSF
"R"RATING OF WALLS, FLOOR, ROOF N/A
MODULES PER BUILDING 1
HURRICANE PROTECTION USAGE NO
HURRICANE SHELTER USAGE NO
SQUARE FOOTAGE 1,650 SQ. FT.
zZZ
o
_
REVISIONS
FRAME
OUT
REV DESCRIPTON DATE BY
1 REDESIGNED LAYOUT 4/1/20 MTB
---- '--""---'-DOOR --------""
iV
SWINGING
O
DRAWNar-
MTB
DATE.3/8/20
LOCAT'N20
Hammock Lane., Pt. St. Lucie
SIZE` 551 X 30'W X 12'H
30'-0" MID END WALL
REAR END WALL"'—'`
b
iV
in,i4G
LLJ
\
/
C7
r='f
/
�%:lCtI I1i}'
AME
FROUT
I_ 55'-0"
LEFT/RIGHT(MIRRORED) SIDE WALL
LLJ
F
-:Matthew
B loridaLcensT. e #64608
Sheet: CA -3 OF 4
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
S(4)CREWS #12-14xj" SELF—DRILLING
NIPPLE TO
BASE RAIL NIPPLE T
BASE RAI
POST TO BASE RAIL
CONNECTION
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH Ir
SC)REWS 14xj" SELF—DRILLING
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi" 2"x2"x2" 16 GA. ANGLE CLIP
SELF—DRILLING SCREWS SECURED WITH (4) #12-14xj"
_— SELF—DRILLING SCREWS
INTERMEDIATE POST TO
END POST TO BASE RAIL HEADER/BASE RAIL/OR
CONNECTION WINDOW RAIL DETAIL
2"x2"x2" 16 GA. ANGLE CLIP SECURED
WITH (4) #12-14xi" SELF—DRILLING
�SCRFWS
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF—DRILLING SCREWS
NON-STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
INTERIOR
#12-14xj" SELF—DRILLING
SCREWS ® 10" O.C. MAX.,
3" MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX.
FROM CORNERS VERTICALLI
EXTERIOR
DOOR FRAME TO POST
CONNECTION
1i"
ES
MAX. SPACIr
I-3" MIN.
STD. MAX. SP*CING
N VARIES
SIDE WALL ROLL—UP
DOOR/FRAME OUT
HEADER DETAIL
INSTALL PER MANUFACTURERS INSTRUCTIONS
#140" SELF—DRILLING
SCREWS ® 6" O.C. MAX.
& 6" MAX. FROM CORNERS
ROLL -UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
- 165 Mph
ROOF
+27.8/-62.5
FL27402.1 —R1
WALLS
+32.5/-35.2
II—B
DOORS
+32.5/-35.2
FL274O3.1
WINDOWS
+32.5/-35.2
INONE
SWINGING DOOR
1
2
3
407 STEEL DOOR
4
5
ZONE
+17.3
-24.9
+20.4
-48.3
+27.8
-62.5
+30.9
-33.1
+32.5
-35.2
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF—DRILLING SCREWS
SINGLE OR DOUBLETS
—HEADER
HEADER CONNECTIO
DETAIL OPTION 1
26 GAUGE ROOF SHEATHING SECURED WITH
(1)#12-14x4" SELF—DRILLING SCREWS
'2-1-2-1' (6" O.C. (s" O.C. MAX.))
1" 16 GAUGE FURRING CHANNEL
48" O.C. MAX. SECURED WITH
(2)#12-140" SELF—DRILLING
SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
NIPPLE TO
\\TRUSS _
16 GA. U—CHANNEL
BRACE, MIN_ 24" UP TO
7' POST, MIN. 48" OVEF
7' POST. MIN. 45' TO
MAX. 60' FROM HORIZ.
(EXCLUDE END—WALLS)
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xi" SELF—DRILLING
SCREWS
BOX EAVE RAFTER TO
POST CONNECTION DETAIL
IPPLE
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH ,.. a1��
SCREWS 14x" SELF—DRILLING �(..iL�7
SINGLE OR DOUBLETS
HEADER CONNECTION DETAIL
OPTION 2
NIPF
TO TRU
MINIMUM 6" TS NIPPLE.
NIPPLE SECURED TO WALL
POST WITH (4)#12-14xj"
SELF—DRILLING SCREWS
POST TO TRUSS
NIPPLE
TRUSSED RAFTER
CONNECTION DETAIL
CONNECTION
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1 —R1
UTILITY STRUCTURE
Hampton Rib Roof Panel
II—B
WALL SHEATHING
Carports Anywhere
FL274O3.1
INONE
Hampton Rib Wall Panel
INONE
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
Vult-165mph
407 STEEL DOOR
HURRICANE SHELTER USAGE
ROLL—UP DOOR
JANUS INTERNATIONAL CORPORATION
FL12765.3—R5
REVISIONS
SERIES 3100
CODE VERSION
FBC 2017 6th Edition
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
INONE
FIRE SUPPRESSION SYSTEM
INONE
OCCUPANCY
JUTILITY, U
WIND SPEED
Vult-165mph
ENCLOSURE
PARTIALLY ENCLOSED/OPEl'
INTERNAL PRESSURE COEFF.
+/— 0.55/0.0
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
0PSF OR 3001b P.L
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR,ROOF N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,650 SQ. FT.
REVISIONS
1 IREDESIGNED LAYOUT 1 4/1/20 1 MTB II
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
55'L X 30'W X 12'H
.01
Jy�
Q 0'8' heW T. BaldWin P.E.
Florida License #64608
w W
F Sheet: CA -4 OF 4