Loading...
HomeMy WebLinkAboutConstruction PlansI M BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A7003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-143/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL GROUND ANCHOR WITHIN 6" OF EACH POST. ANCHOR SECURED WITH z" GRADE 5 BOLT MINIMUM WITH 2" WASHERS GRADE DOUBLE 4" HELIX EARTH AUGER GROUND ANCHOR (SEE CHART FOR LENGTH) GROUND ANCHOR FEB 0 4 2020 ST. Lucie County, Permitting SWINGING DOOR M RAIL DETAIL BASE RAIL ASPHALT OR MINIMUM SOIL BEARING CAPACITY 2,000 PSF (TYP.) BASE ROLL —UP DOOR ROLL —UP DOOR 'Ground Anchor Length (all huilding'w dths53D1 Wind Speed (mph) Soi l Type: <140 145155 160-170 175480 Verydenseand/orcementedsand,coarsegravel, 30" 30" 48"' 48" cobl ies,preloaded silts, cia ys a nd cora I. Medium dense coarse sands,sandygravels, 30" aR 48" 60" ve stiff-silts,anddays Loose"to medium dense sands, firm 'tostiff 48" 48" 60" 60° clays, s i its, a nd al I uvia I fi I I Loose sands, firm days, silts, and alluvial'fiI1 48" 60" 60"" 60"* '-2 anchors per post unless -soil changes td a more desi reable'type atha If depth or. sha l lower. 90 0 ��.cci��2 RINVIEWE® FOR CODE COMPLIANCE ST. LUCIE COUNTY B®CC �1 I a , C®p). CODE I BUILDING TYPE IUTILITY STRUCTURE PROTECTION 0.1 SQ. Fr. MTB I— -" 2790 Gentile Rd., Ft. Pierce II 1"" 351 X 26'W X 10'H II E Z3 z C O Y W Z Sheet. A I 11/22/19 Matthew T. Baldwin P.E. Florida License N64608 CA-1 OF 4 CAMMSANY MH CODE INFORMATION CODE VERSION BC 2017 6th Edition b. ¢S MANUFACTURER ACAIRPORTS ANYWHERE b� BUILDING TYPE UNLRY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE '�' '-t}• '-t}• '-t}' •-t}• OCCUPANCY UTILITY, U .�. .�. WIND SPEED Vult-165mph EXPOSURE B •q DODOORP �woaP ENCLOSURE ENCLOSED OPEN Y 4 INTERNAL PRESSURE COEFF. +/- 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 300Ib P.L. FLOOR DEAD LOAD 10PSF 3'-�' '�'-t• FLOOR LIVE LOAD 50PSF L, "R`RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 FRONT WALL EMI END WALL REAR END NiALC HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 910 SQ. FT. REVISIONS REV I DESCRIPTON DATE IB7 DMWN W' MTB DAM.11/20/19 U)=ON: 2790 Gentile Rd.. Ft. Pierce sm 35'L X 26'W X 10'H LEFT SIDE WALL Cn LLJ W .o C� Z • o.a Vnx. Q W ,s' a RIGHT SIDE WALL 1 1 /22/ 19 Matthew T. Baldwin P.E. Lt1 Florida License #64608 � Sheet: CA—L OF 4 bl I 1 1 1 I 1 I 1 1 1� I II Ago CARPORTSANYWHERE CODE INFORMATION CODE VERSION BC 2017 6th Edition SCE-7-1 0 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph 4 4 EXPOSURE B ENCLOSURE ENCLOSED OPEN INTERNAL PRESSURE COEFF. +/- 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1DPSF ROOF LIVE LOAD ZOPSF OR 300jP..L FLOOR DEAD LOAD 1OPSF _ FLOOR LIVE LOAD 5OPSF s•-o• as'-o• _I zs•-o• "R"RATING OF WALLS,FLOOR,ROOF N/A FRONT END WALL MID END WALL REAR END WALL MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 910 SQ. FT. REVISIONS REV DESCRIPTON DATE BY .o DM N ar: MTB DAM 11/20/19 taCA W 2790 Gentile Rd., Ft. Pierce SEE 35'L X 26'W X 10'H 35'-a• s' o LEFT SIDE WALL 4 co ne/�ArI'1nI W_ i RIGHT SIDE WALL W 1 1 /22/ 19 Matthew T. Baldwin P.E. LL1 Florida License #64608 r Y) Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SECURED TO WALL POST WITH MINIMUM 6" TS NIPPLE. NIPPLE (4)#12-14x}" SELF—DRIWNG (4)#12-14 SELF—DRIWNG SECURED TO WALL POST WITH Ir SCREWS (4)#12-14x4" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CUP SCREWS NIPPLE TO 2'x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14x}" BASE RAIL NIPPLE T A" SECURED WITH (4) #12-14)1 2"x2"x2" 16 GA. ANGLE CLIP SELF —DRILLING SCREWS BASE RAI L SELF —GRILLING SCREWS SECURED WITH (4) #12-14x4" _ _ _ _ _ _ _ _ _ SELF —DRILLING SCREWS SINGLE OR DOUBLE TS '11� III_I-II1-IIImo_- -�I-I -i I' ! -1 i = 1,-1' HEADER IPPLE T SINGLE OR DOUBLETS HEADER BASE RAI � �" INTERMEDIATE POST TO POST TO BASE RAIL END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION HEADER CONNECTION DETAIL CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 OPTION 2 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF —DRILLING SCREWS 26 GAUGE ROOF SHEATHING SECURED WITH VARIES (1)#12-14xj" SELF —DRILLING SCREWS ® ;nfPOST '2-1-2-1' (6" O.C. (9" O.C. MAX.)) TTD. MAX. SPACIN 2"x2"x2" 16 GA. ANGLE CLIPSECURED WITH (4) #12-14x{"MIN.SELF—DRIWNG SCREWS MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL WITH —14x " STD. MAX. SP CING 1" 16 GAUGE FURRING CHANNEL SELF —DRILLING SCREWS 48" O.C. MAX. SECURED WITH VARIES (2)#12-140" SELF —DRILLING SCREWS TO EACH RAFTER. NON-STRUCTURAL HEADER OR > SIDE WALL ROLL -UP WINDOW RAIL TO POST DETAIL DOOR/FRAME OUT ROOF PANEL CONNECTION POST TO TRUSS HEADER DETAIL VERTICAL SHEATHING OPTION CONNECTION INSTALL PER MANUFACTURERS INSTRUCTIONS KSCREWS #14x1" SELF —DRILLING #12-14x#" SELF —DRILLING SCREWS ® 6" O.C. MAX. SCREWS ® 10" O.C. MAX., & 6" MAX. FROM CORNERS GA. U—CHANNEL 3" MAX. FROM CORNERS ACE, MIN. 24" UP TO HORIZONTALLY/ 4" MAX. POST, MIN. 45" OVE FROM CORNERS VERTICALLY POST. MIN. 45' TO I II X. 69 FROM HORIZ. INTERIOR EXTERIOR 'I�" CLUDE END —WALLS) �12 " TS NIPPLE. NIPPLE MINIMUM 24" TS 2„O WALL POST WITH" x}" SELF —DRILLING NIPPLE DOOR FRAME TO POST CONNECTION ROLL -UP DOOR TO BOX EAVE RAFTER TO TRUSSED RAFTER POST CONNECTION POST CONNECTION DETAIL CONNECTION DETAIL DESIGN PRESSURES - 165 Mph ROOF +22.0/-48.4 WALLS +22.8/-25.4 DOORS +22.8/-25.4 WINDOWS +22.8/-25.4 1 2 3 4 5 ZONE +11.7 -25.8 +14.3 -39.1 +22.0 -48.4 +20.1 -23.8 +22.8 -25.4 APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1—R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL12765.3—R5 SERIES 3100 TYPE U ROOF DEAD LOAD JIOPSF ROOF LIVE LOAD OPOR 3001b P .L FLOOR DEAD LOAD 1SF OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS.FLOOR.ROOF N/A (n J_ Q t- w 0 11/201' ILOGnoN: 2790 Gentile Rd., Ft. Pierce 1'_. 351 X 26'W X 10'H 11 Sheet: P. 11/22/19 Matthew T. Baldwin P.E. CA-4 OF 4