Loading...
HomeMy WebLinkAboutBuilding Plansf 8.68kW SOLAR ARRAY PLANS FOR HENRY LAFOUNTAIN 122 DUSK WAY FORT PIERCE, FLORIDA 34945 ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE DATE: W `fo ' PLUMB: DATE: MECH: DATE FILE COPY PROJECT DESCRIPTION: 28 MODULES - MISSION SOLAR: MSE310SQ8T 2 INVERTERS - SUNNY BOY: SMA 5.0 GOVERNING CODES: 2017 FLORIDA PLUMBING CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA BUILDING RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA MECHANICAL CODE, 6TH EDITION NEC 2014 NFPA 1 2015 INVERTER & DISCONNECT IN. f UEARANCE . �� oER NEC 71026(A) MISSION SOUR: MSE310S00T W, G 3, 1% TYP. MODULE ROOF LAYOUT 0 ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE DATE: PLUMB: DATE: MECH: DATE: FILE COPY � c120tiT ' tiREAR__ GENERAL NOTES: 1. THIS IS TO CERTIFY THAT TO TEE BEST OF MY KNOWLEDGE AND BELIEF, THESE PUNS CONFORM WITH FLORIDA BUILDING CODE 2017 WITH ALL SUPPLEMENTS AND ADDITIONS. 2. ALL PRODUCTS TO BE INSTALLED PER MANUFACTURER'S WRITTEN SPECIFICATIONS. I, ANDREW D. HALL PEJ 87479 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC 107. Wind Design Data Wind Speed 160 mph Risk Category ➢: Exposure C Gust Factor f0.18 "A" Dimension 5.1 ft Roof Pressure for Components and Cladding Zone 1 21.47 psf -33.75 psf Zone 2 21.47 psf -59.40 psf Zone 3 21.47 psf -87.75 psf NO 0479 9 ' �4'i'�TE""O F '• �: a 8 W_ U �NG.I lRO7 m TECH. a DRAWING INDEX: w oc np15 rj�nCpll S-1 COVER 3 oc C2) f o Cr4l S-2 ARRAY LAYOUT & DETAILS a N S-3 ELECTRICAL S-4 NOTES v S-5 SPECIFICATIONS S-6 SPECIFICATIONS a S-7 SPECIFICATIONS E3 a QMR-UEC (TYP) PV MODULE 3/8"-16 X 3/4" HEX HEAD BOLT 3/8" - 16 FLANGE NUT QUICK MOUNT PV KIT (TYP)� QMR-UMC CUP QMR CROSSRAIL STANDARD I 'EXISTING UNDERLAYMENT EXISTING ROOF TRUSS 1/2" PLYWOOD 5/16" DR SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS QUICK MOUNT PV K (TYP) OMR-IIM(. (`1IP TOP VIEW NTS UUIUK MUUNI YV KII '+0 MAA. U.U. (TYP) (TYP) w MISSION SOLAR: MISSION SOLAR: MSE310SQ8T QMR-UMC CLIP MSE310SQBT (TYP) (TYP) (TYP) w d QUICK MOUNT PV KIT J (TYP) QMR-UMC CUP (TYP) TYPICAL LAYOUT NTS -�-L QMR-RS14 (TYP) n a y n STANDARD QMR-UEC CLIP (TYP) QMR-UEC CLIP (TYP) No A0479 R w w U CV] V J J S—L NOTES: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE USTED PER NEC 690.4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPUANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ 'WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT WHERE TWO DIFFERENT AMPACTIIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) 10. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 12. LINE TAPS TO BE MADE WITH ILSCO KUP-L-TAPINSUTATION PIERCING CONNECTOR. 13. CA BUILT IN TO ALL SUNNY BOY INVERTERS. #6 THWN-2 (3 CONDUCTOR) 1" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC CONDUIT L2 L1 PV AC DISCONNECT 60A 240V 2-POLE 60A RK-1 FUSE METER O 60A SUB PANEL PV AC DISCONNECT (2) 30A 2-POLE BREAKERS NEUTRAL BONDED TO GROUND AC PANEL 200 L1 SUNNY BOY: 5.0-US W/ SUNNY BOY RSB-2S-US-10 & RSC-IX-US-10 SYSTEM RAPID SHUT DOWN COMPONENTS PER NEC 690.12 #8 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC CONDUIT L1 \AC L2NTHWN-2 G SOLADECK COMBINER BOX 60OV/ NON -FUSED #10 THWN-2 3/4" EMT OR FMC CONDUIT #10 AWG CU WIRE POSITIVE & NEGATIVE 3/4" MNLT CONDUIT 7 MISSION SOLAR: Lt MSE310SQ8T (TYP) L1 7 MISSION SOLAR: U2 MSE310SQ8T (TYP) 30#8 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR SOLADECK COMBINER G N APPLICATION USE PVC OR BOX 600V/ NON -FUSED LFMC CONDUIT 7 MISSION SOLAR: 3 N Lt MSE310SQ8T (TYP) L1 DC 19 L2 #6 THWN-2 CU CONDUCTOR AC Lt 7 MISSION SOLAR:L2W/ (1) #8 E.G.C. IN A G MSE310SQ8T (TYP) 1" EMT, FMC, FOR EXTERIOR #8 THWN-2 APPLICATION USE PVC OR LFMC CONDUIT SUNNY BOY: 5.0-US #10 AWG CU WIRE W/ SUNNY BOY RSB-2S-US-10 #10 THWN-2 POSITIVE & NEGATIVE GEC BOND AT & RSC-IX-US-10 SYSTEM 3/4" EMT OR FMC 3/4" MNLT CONDUIT RACKING SYSTEM BARE COPPER GEC RAPID SHUT DOWN COMPONENTS CONDUIT (SEE NOTE #2) PER NEC 690.12 No 8L479 :T F T w•. t..moms si P^4N� 0 d 0 U U U J V) M z O M O 3'� Zgo� Nm� wow w�=� H N Z N Z M a n w w o z or a z Z S-3 MODULE SPECIFICATION MODULE MAKE MISSION SOLAR MODULE MODEL MSE310SQBT FSEC CERTIRMON i1 PMAX (SIC) 310 W VOC (SIC) 40.12 V VMPP (STC) 33.17 V ISC (STC) 9.76 A IMPP (STC) 9.35 A - NOCT 48 C TO ISO 0.039 S/C TO VOC -0.280 8/C TO PMPP -0.377 S/C OPERATING TEMP. -40-+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WfTH ANSI Z535.4-2011. SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: "PHOTOVOLTAIC DISCONNECT.° THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL INVERTER SPECIFICATION INVERTER MAKE SMA SUNNY BOY INVERTER MODEL SMA 5.0-US MAX AC POWER OUTPUT 5000 kW MAX. INPUT VOLTAGE 480 V NOM. DC VOLTAGE ® 240V 380 V NON. AC VOLTAGE 208 V MAX. CONTINUOUS OUTPUT CURRENT 24 A MAX. DC CURRENT 18.0 A KW. DC POWER (STC) 5150 W CEC EFFICIENCY 96 % N AN EMERGENCY CONTACT ALTECH ELECTRIC 1-863-399-2175 � CAUTION THIS SERVICE IS SUPPLIED BY MULTIP SOURCES. SEE DISCONNECTS BELOW. Ai PHOTOVOLTAIC SYSIETE EQUIPPED WITH RAPID SYSTEM SHUTDOWN SOLAR PHOTOVOLTAIC SYSTEM -WARNING- AUTHOR® PERSONNEL ONLY RATED AC CURRENT: 60A NOMINAL AC VOLTAGE 208V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT Ai -WARNNG- ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DCATION: AC Z& WARNING - ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THE PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUDIONIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOLUS, OTHER ENCLOSES HOLDING DC CONDUCTORS DIRECT -CURRENT PHOTOVOLTAIC POWER SOURCE _® WARNING - AUTHORIZED PERSONNEL ONLY RATED MAXIMUM POWER-PONT CURRENT: 46.10A RATED MAXIMUM POWER -POINT VOLTAGE: 239Y MAXIMUM SYSTEM VOLTAGE 239V SHORT CIRCUIT CURRENT: 48.8A LOCATION: INVEHIER ENO J6 479 .* cr J r v J V) M z O M 0 O -13M U UY J c a� Lu Lu U z a M Lu Lu � s Ci a H Z DAS. NO. S-4 0 n • •1 ELECTRICAL SPECIFICATIONS Power Output Pmax WP 300 305 310 M6SWle Ef(Kie`ncy :? ' � g,. i',^ 80S`�' 1ii.35 : 18.65 Tolerance 0-+3% 0.+3% 0-+3% Sh .grtult Current .} 't(4c J4 fi �9571 *.� 9.664' 9.760' Open Circuit Voltage Voc V 40.08 40.10 40.12 Rated Voltage Vmp V 33.12 33.14 33.17 ormafOpera IlgCelliTemperatur'o[NOGn�:.�"�'�46.09°C (t3°C1- . Temperatwe Coeffidernuf Pmax -0.377%/°C 7empeatlaeCoeffidentof,Vac x_;-i`=� '-tr280961'G rr TemperatweCoeffldentoflsc 0.039%/°C 10 •• • • • a 3 �4aidmum 5ystemYoltage 1,000VDC - -' - `o Opemfblg Temperate eRange-40°C(-4(°F)to+85°C(1857) a Fire Safety Classification Classc Hall SafetylmpactVelodty 25mm at 23 m/s Cell orientation 60 ceils(6#0), 5 busbar � uie dime4sl p 166,4QtiiAR 99�Rmm 15,k4mm , t � � ` Weight 182 kg(40.1 lb) mntGlas3 ': 3.2mmt0 i267n.Jlctin'" �, tx>. .�; w=iA001GeLt€�iY Frame Anodized aluminum alloy J-Box Protection class IP67with 3 bypass -diodes Connector MCA 1101- Container FTC Paliets;Panels 305W 53' Doubiestack 36 936 285.48 kW Double stack 28?28'. 222J1M1kW ' ' Panels Weight Height Width Length NRet 26 j1051bs'' 45.50: ' 45.50` I 67.0W Mlssion Solar Energyreserm Me r•hz W matr zpedfizaepn plwnees wlNOue nobw a :CL_ASS,'L'_EAO NG'30Q-31'OV1` FEC 61225 / 61730 / 61701 UL 1703listed q©°' lad. CEC MSE305SQ&T: 30SW P, 60CELL SOLAR MODULE CURRENT -VOLTAGE CURVE c utww•n•c Inddenikrd--1.mU=w(^• 305.1 w ] :riV nNdent IrrE.=6o0_=w{m.,1 y_ loadem lnd.4co sW/m ax Incident esd.200?W/m 0 0 W ID G Voltage M Cumem-wltage characteristics with dependence on madlance and module temperature BASIC DESIGN (UNITS: mm) FrontView Back Yew 711 MISSION SOL A ENERGY Maden Solar EneWl 8303 S New Bnuafels Ave SanAnWin T as78235 In100Msslpnwlarwm l www.mixai0nwlaewm General dam Fealares r INS Q MD3FNU3Aq :... �@ wVSW 4-9 1 dx i5a k'. �No 8 479 ,* ��`• TGnn\QP'fo=� E d �m fi U U T n 6 U U J J S-5 0 1 1 e_ J_ _ `ItNlli Y toft` k Toml44aTIIM X=mx .r AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)l Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Quick Mount PV Manufacturer: Quick Mount PV Address: 2700 Mitchell Dr. Bldg. 2 Address: 2700 Mitchell Dr. Bldg. 2 Walnut Creek, CA 94598 Walnut Creek, CA 94598 Country: USA Country: USA Contact: Benjamin Kuttesch Contact: Benjamin Kuttesch Duane Menton Duane Menton Phone: (925) 478-8743 Phone: (925) 478.8743 (925) 478-8847 (925) 478-8847 FAX: (925) 478-8765 FAX: (925) 478-8765 Email: ben.kuttesch@quickmountpv.00m Email: ben.kuttesch@quickmountpv.com duane.menlon@quickmountpv.com duane.menton@quickmountpv.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008516 Authorized by: 004—us. i Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. In.mwaau canoe aym�a hma useaweaumm>suonm Men. odyme rnmnbeuu�.amc.mumr�rraasmewenmmroamomm�mmmaa en .. ..�..- _. rssmdeeta Ne anatlena lad M N aaaprem,entaW In We PUNonnllrn b Mao. MyNMerum aln" Inb,bknann Ira Ne eat fist W eppmm b x+l4np py lae�ek Wlld Fatlary Avammenb eM Fd1uW up SeMwaa,e htlle pWyoee olaeswlp eppreprlet egea N, Neyere mlblM pugaamorpoE,Aim yue0ry mntra eMEo rolldien Ne L4amalNtlraEllpallort.In OJa mpeR Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3a51 or 847-439-5667 Fax 312-283-1672 Standard(s): Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat - Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.t] Product: Photovoltaic Racking System QRall - Installed Using Quick Mount PV's QRaiI Series Installation Manual,Jan-2019 Rev 4 Brand Name: Quick Mount PV Models: QRaiI ATM for Report 101786065LAX-001 Page 1 of 2 ATM Issued: 5-Feb-2019 W 18115(PRp-17) WrAa 1 710Stud` af ENO UITY", lrigenyfty iriEnglneering+ � I C uick Mount ,-V, '_RESPECT THE ROOF% Rail Spans for Quick Mount PV QRail Standard System Mean Roof Height: 0 < h 515 ft Panel Orientation: Portrait Table 1 Roof Angle: 0< B 5 7 degrees Exposure Category: C Roof Ground Wind Speed (mph) Wind Zone Snow, Load 100 110 115 120 130 140 150 160 170 175 180 190 0 116 116 116 ,:114 104 95 -89' 82 -77. ; :75 ' 73-, , ;69.;= 10 102 102, 102 "101 100-1 ",95 ;:89- 82 ="77 75...E i"73 •:-69 >. 20 86 86 '86 86'. '86' )z86,:,' ;., 86 ?'-.. 82 ,'77 „75�.; 1,73 30 74 74: V =:: 74`'' - 74' 74, � "'°'74 -74 �- - ' 74 , 74 +� ' 73 � >:; 73,;r • �69 a Zone 40 '.65 65r•; `,, 85 c, �. ,65'„ 65,.,. �,�65 .�b5` 65` : `:;65. , _"65.- ', 65 . 65 1 50 ;59 ,, ;r±s55 .....59.=':.. 59 'i:r59 ", 60 5¢ '- 54:� "54' 54 5:4 ,'.54. ''54 `54-;" r54,-a"54° =54?70 ': 50D�; ' 50 50 „ -'Sox,-O ' `50 - ;50 � 0i8048 IsK.86"'.. 48 48 48 48 48 48 48 48 48 48 9044 44 44 44 44 44 44 44 44 44 44 0 100 - 86,. 82 75� 64 65. -60 .57 ',55 53 50SO 100 86 82 75 ;69 65 • 60 57 53 ,50 20 66":.82 75 . ;69 65 s 60 -57 "55 •'� 53 50k. 30 ', -74 '` 74 , ` ",i4 �74- 741' x69ri GS 5 60, ,57 55 e 53 SW Zone 40 '65' , .5 o-#5.,. ._ 65;, ,. 65.-..._EtS .,65 , 60' x... t' 53 ,.. r 50, 2 50 =.59.'t ,59,�m 59 ,. ;;`59i 59, y""59 °a .,.�59 ,' 59 57a#"_SS.._-:i $3 `..: 50-` 60 ''54 54" ; 54'*.. 54` 54:,,:';i54:: y"54 ". 54 t54 ."54 .:..'S3', 50'': 70 50 50' j !. SO' 50 50 SD - ''So 5o 50'--1'':so, 50' 1 So '- so 48 48 48 48 48 48 48 48 48 48 48 48 90 44 44 44 44 44 44 44 44 44 44 44 44 0 79 71, .68- '` 65 59- r:55 !..51 48 45 44 42 40 10 '79 7V", _.._. ..._.. 65 59 _..._. i55 ...'51 > 48 45 44 42 40 20 ' '79 65. -59, v..'S%" :51 :: 48 45 44 42 40 30 ;':74., ';7Uw.t 65'. 59a55>:y d51 '-: 48 45 44 42 40 Zone 40 65 '654-'t,'65' .65' 59'.°51 :i 48 45 44 42 40 3 50 '''59 59 '- ` 'S9 59' 59 • -5S' ' ' 151' 48 45 44 42 40 60 54 54',' 54 54 54 ''54 51; 48 45 44 42 40 70 so 50-,'; 50 50 50 ''`50 `:.50 48 45 44 42 40 80 48 48 FI 48 48 48 48 48 48 45 44 42 40 90 44 44 44 44 44 44 44 44 1 44 44 1 42 40 Notes: 1. Tables are based on critical rail span for load combinations as specified In chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" 959 Larchmont Court, Aurora, IL 60504 630-219-1997 (P) www.structuralenginuityinc.com 3/4/2019 bit ���•- 'CEN3'ry�l�'G No $I479 *V W 0. P, : �� d U J 3 lam L-Mount Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket Locate, choose, and mark centers of millers to be Carefully lift composition roof shingle with roofing Insert Flashing between lst and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of Flashing is at least N" higher mounts will be placed. nails as required and backfill holes with aproved than the burtedge of the 3rd course and lower sealant See 'Proper Flashing Placement' on next flashing edge is above the butt -edge of 1st course. page. Mark center for drilling. Ifaltachingwith lagbolt usea%u"bit (Lag). Use Clean offanysawdust, and fill holewithsealant Place L-foot onto elevated flute and rotate L-foot re %'bit(ST) forattachingwhh the stmcturalsarew. compatible with roofing materials. desiredarientadon. Drill pilot hole into roof and rafter. taking care to drill square to the root Do not use mount as drill guide. Drill a 2' deep hole Into rafter. L-Mount I QMLM / QMLM-ST Elevated Water Seal Technology® DESCRIPTON 1 WASHER, SFAUNG, 5/1 a ID X 3/4' OD, EPDM BONDED SS I I' 4 LAG SCREW. HEX HEAD. 5/16'xb", 18-8SS I 2.0c) v9.397— -LW 2.07 3.30 .90, O I o- 2.(3.11541 414 2.1 1 J_ QMLM QMLM-STT �� +w u- ,n u• a A1{oNCRM0YMrV -... ` w4G -- 1,.w,vervTE-ron XUCT STRURAL SCREW AVAILABLE ON QMLM-ST VERSIONS ONLY / AVAILABLE IN MILL, AND BLACK FINISHES Quick Mount laV' QMLM & QMLM-ST: L-MOUNT, 2-1 /16" SLOT ^aasr<"uu ;SIZE nRAWN Bx: RAn RS iM.VLb WCIM1I I pAie 7/16/3m0 it 9 2 B %%%I {ur////'/ N0 re U J ..5 V) ' a Z rn Q M tn m tn Z o LU CD I W U = a M bb N CD t N Z a n W to W w CD Or d Z N W O Prepare lag bolt or structural screw with sealing You are now ready for the rack of your choice. O washer. Using a'Mnch socket on an Impact gun, Follow all the directions of the rack manutactuer w (/ \�' drive prepared lag bolt through L-foot until L-toot as well as the module manufacturer. NOTE: Make Gp is Mount PV® can no longer easily rotate. DO NOT oveo-torque. � Um top of L.Footmakes solid contact with racking NOTE: Structural screw can be driven with T-30 hex RESPECT THE ROOF 3 head bit BI7.2.3-44 Jul-2018 Rev 4 81723-44 Jul-2018 Rev4 U W CD U arN ll w po S-/