HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SET 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. AC1318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8'58" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE I -ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 ii-i. AIR ENTRAINING +/- 1 %-ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM Al B5 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1"MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 272"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. S. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1 /2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8'. 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-WIN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT -.WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPRWISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2'k4'k0.044'k0. 100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE' FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2'SQ'k0.044" 2 x 3: 2'k3'k0.050" 2 x 4: 2"x4'k0.050" 2 x 5: n5'k0.050" OPEN BACK SECTIONS 1 x 2: M<2'k0.044" 1 x 3: 1'k3"x0.045" SNAP SECTIONS 2 x 2 SNAP: 2'S<nO.045" 2 x 3 SNAP: 2'k3<0.050" 2 x 4 SNAP: 2`xN'A0.045" SELF MATING (SMB) 2 x 4 SMB: ZX4"x0.044'kO. 100" 2 x 5 SMB: 2'k5'x0.050"x0.100" 2 x 6 SMB: 2'k696.050'k0. 120" 2 x 7 SMB: 2'k7"x0.057'k0.120' 2 x 8 SMB: n8NO.072'k0. 124' 2 x 9 SMB: 2x9'k0.082'k0.124" 2 x 10 SMB: 2"xI Mx0.092'x0.398" DETAIL A o u ui a o c w � N d 9 c c7 � N 0 V w rn U a 1 '1� GG GO �o ivle _® 6 - o w n: o 0 c m N m p\ a N 2X3X.050 DIAG. BRACE TYP. c Li rn li U O V N m J O In a J 0 cM z : ❑ U U o HOST 24" 0/H STRUC. GUTTER q W J O 0 N NW Q LL Lii .L 1X3 66' 0" 1X3 4 Z LIJ m ,c 2X5 DJ j 2X5 DJ o co — H o \ ; 4 Z O c 2X5 DJ \ 2X5 DJ Q Q w ^I Q Q = —T2X5SMB 2X5SMB U 0 r Ch I j N O00) M x `\ O i M M _ J . art o N ` N m \`\ i j %' + x N LL V O T` m m `\ �' i x N T` N x `\ % i 2SMB ;; 2XSSMB j O 09 U \ = u1 L 1X3 1X3 +8 0 --------------------------- -------------------------------------------------------------r i -� i `�' 1X3 + 3X2 \ \� m 2X10 SMB C.B. / U X N N m W d 2X3 TYP. % U Z LLi N ROOF RISE a'o^ M",) `� A Z) '`----------- 1X3 TYP. 1X3 TYP. /� // w w Q U o t�8'_0 F 5'-0" F 40 _0„ 5' 0" i a h �.. o w �nC°ia o rc I DESIGN DATE: 01/29/2020 i z'c^cealR RnIL L--1___________ REVISION I: DATE Roof RISE PROFILE REVISION 2: DATE PAGE: SCALE N.T.S. DRAWN BY: ST SCALE: NTS 2X3 TYP. N N N N to N N N N � N N N � N 2X3 TYP. , ,�_ �,.�..8'-4"+8'-4"i-8,_4„+--8'-4"�8'-4"-F�8,_4,�--I 0 GIRT FASTENED INTERNALLY AT EACH END w/ #10M.5'EACH SCREW GROOVE. FASTEN TO BEAM W/ 2XZX.125 ANGLE (2) #12 SMS INTO BEAM 8 (2) 0101.5 THRU ANGLE INTO GUTTER WHERE NO GIRT IS PRESENT, ATTACH ANGLE DIRECTLY TO GUTTER PX218'.12 ANGLE \ w/(D SMS EACH LEG , BEAM CLOSE BOTTOM OF 11� I o 0 BEAM WHEN TRIMMED .044 RECEIVING CHANNEL FASTEN W$D #12 SMS EACH SIDE OF BEAM - GIRT #10 SMS WITHIN 6' OF BEAM 8 24' D.C. FOR BEAMS ABOVE 2X8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS 8 INCLUDE 2' GUTTER BRACE AT EACH BEAM LOCATION FOR GUTTER TO FASCIA: (2) #R SMS (0 #14 0 IS-D.C. FOR GUTTER BRACE/ STRAP: (2) #A EA. STRAP SEE TOP VIEW FOR BEAM OVER 2aS .OLD RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLY WE) #12 SMS ALTERNATELY 2x2X1/0' ANGLE BELOW GIRT, (2) #14 SMS INTO BEAM a (2) #12 SMS INTO STRUCTURAL GUTTER SIDE VIEW FASTEN GUTTER TO FASCIA W/ #I4x2' WOOD SCREW 18' O.C. (2) #12 SMS .05V GUTTER STIFFNER FASTEN TO FASW W(D #14A2- WOOD SCREW FASTEN TO GUTTER FIE) #12 SHE , GUTTER GUTTER WHEN BEAM 6 PURLIN HIT ON CORNER - FASTEN OUTSIDE OF SE AM 8 PURLIN / 1/0'xTx2' ANGLE 8 (4) #12 SMS EACH LEG FASTEN INSIDE CORNER IIIIII A IIIIII (BEAM TO PURLIN) W/ 2 SMS ANGLE T) #12 SMS INTO EA. MEMBER (BEAM fl PURLI W DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: N.T.S. �(2) #16x2' 2x2X1/r ANGLE WOOD SCREW (2) #12 SMS EA. SIDE OF BEAM (2) #12 SMS EACH LEG EACH SIDE FASCIA T'x6'MIN. EXISTING) #12 SMS EA. LE W/(2) GIRT -� #12 SMS EA. LEG STRUCTURAL GUTTER TOP VIEW SMB DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: N.T.S. U8'X2'X4' STRAP r-F (2) #12 SMS INTO BEAM (2) #12 SMS INTO GUTTER 0 0 T o o I ° FJ °I O of O� 01 0 1 0 l \o �I A ° F 3/16'-5052-H32 GUSSET �\ 0' ° F INTERNAL OR EXTERNAL 8' INTO EA. SIDE TYP. 2X2XIM ANGLE w/T) ° F (2XIOSMB ILLUSTRATED) 012 SMS EA. LEG -� NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8'MIN. FROM EDGE. FASTENERS MAY STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN I/Y SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8-MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8' OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 TABLE B-I BEAM SIZE COL. TO OFM ATY SMG/ SIDE OF COL. BEAN TO OEAM OT1 SMS/ FACEISIOE 2 x 4 (5) #12 (9)#12 2 x 5 (5) #12 (9)#12 2 x 6 (7) #12 (9) #12 2 x 7 (10) #12 (10) #12 2 x B (12) #12 (IL) #12 2 x 9 (14) #14 (14) #14 2 x 10 (16) #IL (15) #IL DETAIL "K" GUSSET CONNECTION SCALE: N.T.S. (2) #14 WOOD SCREWS INTO FASCIA SIDE VIEW GIRT FASCIA SMB /B'XB'x4'STRAP (2) #12 SMS INTO BEAM j GIRT (2) #12 SMS INTO GUTTER STI TOP VIEW DETAIL "L" CORNER GUTTER CONNECTION SCALE: N.T.S. (9) #IOX2 UB' PLATE ON 45DMGI OR I/8'x2'#' ANGLE WA #12 SMS INTO EACH INTERSECTING MEMBER PERIMETEI FRAMING EBOLT FOR DUE TENSION 1/0'STAINLESS STEEL BRAIDED CABLE DETAIL "1-2" CABLE CONNECTION AT CORNER SCALE: N.T.S. GIRT I/8' STAINLESS STEEL 3000 PSI CONC, STRUCTURAL GUTTER BRAIDED CABLE 40p MIN. 6x6-IOk0 "a MA%. WWM OR FIBERMESH - (2) GUTTER BRACES b t a EACH w/(2) #12 SMS ` �1 E® INTO GUTTER 8 (D #16 X 2' 4' MIN. SLAB WOOD SCREWS INTO FASCIA w/FOOTING A x 3' EMBED REVIE CONC. �8 (oANPCCOSN OR EQUAL° -®DE COW (VV��. 3000 PSI CONC. �uO 6X6M 4W MIN. OR 600 MAX. WWM OR FIBERMESH ' ®O B 0 0 a• CTURAL GUTTER 4• MIN. SLAB w/FOOTING 1.5'X5.5' ALUM. STRAP w/(2) 1/4'DIA. X 2-1/4• MASONRY ANCHOR (TAPCON OR EQUAL) DETAIL "I -I" CABLE CONNECTION AT FOUNDATION SCALE: N.T.S. O O LNn _1 _J I— co It Z Z Q E p V (3 U Lu -j O Oo m LU < J m LL Lf) .� Z I Lu � L HM 0 i c C O LLu Q W a) Q`i 0 M DO V 0 a 04 LL C3 N O z r U L1 LY 0- I� C) ILL LU LU EL J U Z L- CO of w Z' F- ILL a o �ZU W o Z Q of m m O O a w �C-4M Z O O' D: U OL DESIGN DATE: 01129Y2020 2 PAGE: DRAWN BY: ST /� SCALE: NTS /� 3/16" 5052-H32 GUSSET #14 SMS @ 1 1W O.C. 2" X PURLINS ATTACH TO 3EAM WITH MIN (4) #10 X 1 1/2" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER a %\ 1 1/4" (TYPICAL) " 0�2 2y9'T 6� �\�\`✓ 5 6 NOTES: 1. GUSSET DIMENSION ARE MINIMUM (2) REQ'D (1) EA SIDE OF BEAM - MAYBE INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1-1/4" C/C SPACING 3. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. 2"X2"X1/8" ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS INDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAIRRAIL EXTERIOR PLATE CORNER POST EAVE RAIL 1"x 2" O.B. PATIO SECTION 0 \ \` 3° x 3" x 0.050" MIN., 6063-T6 ALLOY O O PLATE DR STRONGER (ONE SIDE) WITH O (3)-912 x3/4" S.M.S. EACH SIDE AS SHOWN (3/8" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 2 x2 x 0.0 K-BRACE LATERAL "K"-BRACING CONNECTION DETAILS 'ANGLE ;1" INTO EACH DICATED BELOW CORNER POST (2) #10 X 1 1/2" SMS THRU SCREW BOSSES SLAB/FOOTING NOTES: SEE PLAN 1. CONNECTION DETAIL AT EAVE RAIL SIMILAR PLATE IERIES--\ SELF MATING DETAIL #2 3" x 2" x 0.050" MIN., 6063-TS ALLOY PLATE DR STRONGER (ONE SIDE) (3) - #12 x 3/4" S.M.S., EACH SIDE AS SHOWN (1I2" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) CONTRACTOR TO INSTALL (2) #14 X 2" SMS THRU BRACE INTO BEAM THRU GUSSET PLATE POST 2 x 0.093 3/8" 0 CONCRETE ANCHOR (2 PLATES) FOUNDATION IN LIEU OF TYP. 114" 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL "K"-BRACING CONNECTION DETAILS ' " O !0 1" X 2" O.B. FASTENED TO CORNER ul POSTW/#12X11/2"SMSAT6"FROM a O TOP & BOTTOM RAILS TYPICALLY @ 24" O.C. p 1/8"X2"X2" EXTRUDE ANGLE 5052 -I— H-32 ALLOY EA CORNER W/(2)#14 X2°m SMS INTO POST & (1) 3/8" DIA CONCRETE SCREW ANCHOR INTO I 0 O CONCRETE 11 6. rn ui m Q Q % — 211VMikoNc rvcNoBEVSEDMENT 1 U N m J (D U-) o J rn co�I1 V Z Z Q E U = O U SIDE VIEW o 6 W=j 000- CORNER K-BRACE DETAIL W Q jrnrn LL. Lo .S SCALE: N.T.S. Z r ~_ LLI Ur I- °i c ~tea 2" Lu 0) � 1 CORNER POST W/1"X2"@ (4) #14 X 3/4" SMS /BACKSIDE INTO < 3/8" X LENGTH AS REQUIRED FOR 21/4" EMBED CONCRETE SCREW ANCHOR INTO CONCRETE 1"X 2" BASE PLATE ANCHORED TO CONC W/ 114" — CONCRETE SCREW (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST AND FRONT VIEW CP- CORNER POST TO CONCRETE DETAIL A-4 SCALE: NTS 6" x 5" x 0.050" COLUMN 6063-T6 ALLOY PLATE (ONE SIDE) OR STRONGER 2 x 2 x0.093 BRACE(TYP.) K-BRACE 2 x 3 x 0.070 CHAIR RAIL O O 0` _________1 0 i O O i O GIRT (CHAIR RAIL) K-BRACE 0 O O O i � 2 x 2 x 0.093 BRACE(TYP.) (11 TOTAL)-#12 x 3/4" S.M.S. AS SHOWN (W" MIN. PLATE EDGE DISTANCE & LATERAL "K"-BRACING C-C FASTENER SPACING) CONNECTION DETAILS (3) 1/4" DIA. MACHINE BOLTS ` w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST ® CARRIER BEAM POST VARIES 1'k2"MEMBER FOR SCREENING HORIZONTAL BEAM ON ITS SIDE (IF REQUIRED) \ �-REC RECEIVING RECEIVING CHANNEL OR EACH SIDE SINGLE HORIZZ'FOONTAL HORIZONTAL BEAM DOUBLE ANGLE HORIZONTAL HORIZONTAL BEAM OR 4k4" (6)#lOxO.7S'SMS EACH SIDE VFOR TRIPLE HORIZONTAL BEAM OR 6X6 #lS MS OF (6) FO 2 ROWS OF (6) FOR 2 R RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL SCALE: NTS T' FROM EDGI OF SLAB/FIG. (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE 91 THIS PAGE ,> FOR BOLT PLACEMENT l :ASTENED TO CARRIER I #10x1-1/2'SMS INTO EW BOSSES EACH END CARRIER BEAM O O O 1'k2'MEMBER O FORSCREENING-\ O ROOF BEAM (SLOPED OR FLAT) (NOTE USE SIMILAR DETAIL FOR NOTCHED UPRIGHT CONNECTION TO CARRIER BEAM #10x1-1/2'SMS@24" FOR SCREW SIZE/ GUANTRY O.C. MIX CONNECTING TO 1'k2" CARRIER BEAM NOTE: FOR DOUBLE OR TRIPLE CARRIER #10x1-1/2'SMS@24" BEAM, OUTSIDE WEBS SHALL OVERLAP O.C. MAX CONNECTING 24' 4x4 POST OR NOTCH POST AS ABOVE i0 NNE POST FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: NTS FOR BOLT PLACEMENT (2) 1/4" DIA. MACHINE BOLTS w/ WASHERS ® 2' FROM EDGE OFSLAB/FTG. TOP VIEW 3'k3" POST (SEE PAGE-2 FOR SIZE) (2) 3/B" DIA. EXPANSION BOLTS SEE NOTE # I THIS PAGE FOR BOLT PLACEMENT (2)w/ WASHERS (2 TO POST/SMB CONN (2) 3/9' DIA. EXPANSION 3'k 'POST (SEE PAGE-2 FOR SIZE) TOP VIEW ROOF BEAM TO C.B. W/ REC. CHANNEL TABLE BEAM SIZE QUANTITY/SIZE LEG TO BEAM EIS QUANTITY/SIZE TO BEAM. INTERNAL 2x4 (4)#12 OR(2)#16 (8)#12 OR(3)916 2x5 (5)#12 OR(3)#16 (10) 9 12 0 R (3) # 16 2x6 (5)#12 OR(3)916 (10)#12 OR(4)#I6 2x7 (6)#14 OR(4)916 (12)#14 OR(4)#I6 2x8 (71#14 OR(4)#I6 T2)#14 OR(6)#16 2x9 1 (8)#14 OR(5)#16 (14)#140R(6)#I6 2x 10 (9)#14 OR(6)#16 (14)#12 OR (7)#16 iR SIZE)cL (2) 1/2' DIA. EXPANSION BOLTS SEE NOTE 02 THIS PAGE FOR BOLT PLACEMENT 114" DIA. MACHINE .TS w/ WASHERS 2' FROM EDGE - OFSLAB/FTG. STITCH w/(2) #12x3/4"SMS @ 12' O.C. \ �3k3k0.12S'ANGLE 50.725 ANGLE • 30DO PSI CONIC. 3000 PSI CONIC. SLAB/FIG. FRONT VIEW SLAB/FTC. FRONT VIEW 6X&I0x10 WWM 6x6-IOx10 W WM OR FIBERMESH OR FIBERMESH 3"x3" POST CONNECTION DETAIL 3"x3' POST w/ 2x SMB CONNECTION SCALE: NTS DETAIL SCALE: NTS NOTES: 1.3X3 POST TO HAVE 3/8" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2" FROM EDGE OF SLAB AND PROVIDE MINIMUM 2" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3" MINIMUM EDGE DISTANCE. 2.4x4 POST TO HAVE 1/2 - RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3-3/4" FROM EDGE OF SLAB AND PROVIDE MINIMUM 3-3/4" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2- FOR PAVER THICKNESS MORE THAN 2-1/2" SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION. (2) 3.3/4" FROM E OF SLAB/ FIG. (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU POST CARRIER BEAM & POST TOP VIEW O CARRIER BEAM O (3)1/4"DIA. MACHINE BOLTS) POST w/ 3/4" DIA. WASHERS THRU CARRIER BEAM &POST lvl FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: NTS -(3)1/4"DIA. MACHINE (4)3/9k4"TAPCON THRU BOLTS w/ WASHERS BOTTOM LEG OF ANGLE INTO CONIC. 3-3/4" FROM EDGE OF SLAB/FIG. TOP VIEW 4'k4"POST (SEE PAGE-2 FOR SIZE) �2k4'k .125ANGLE 3000PSICONC. ®.I sue/FiG. FRONT VIEW 6x6-IOx10 W WM OR FIBERMESH 4"x4" POST CONNECTION DETAIL SCALE: NTS MACHINE BOLTS WASHERS THRU 4M & POST r L r TOP VIEW B J O LLo J rn M Z Z Q_ U elf O U U U WJO co � W Q Lo .L Z ~ r w CD c— M F �'- C c G T W Q �rn Q < 0 F¢- U 0 � ��O M CC) LL cq o N Z ipO U O a COLUMN PER PLAN (3) 1/4" DIA. MACHINE BOLTS w/ WASHERS (LENGTH) ANGLE (4) 3/6T (INTERNAL) THRU BOTOTTOMM LEG LEG U OF ANGLE INTO CONIC. J H J U W W W • a •• �1�-�e w L U HLL 3000 PSiCONC. Z ~ Q /e SLAB/FIG. FIR V (fto ��1r Z U 6x6-10x10WWM ?'!- ��� OR FIBERMESH Q"'. ' > }" O < coJ 4X4 COLUMN ALT. BAS4q A]TAGHMENT a 2 o O coo a DETAIL I SCALE: Tb(;o Z a o w a �9 Q W REVISION 2: PAGE: DRAWN BY: ST �? SCALE: NTS v