HomeMy WebLinkAboutRevision, Approved Deferred submittal3'
0
RUN
1"
RI
S
E
3'
6
1" BEYOND SLIDING GLASS DOOR
PERIMETER SEAL
3/4" RECESS
RECOMMENDED WATERPROOFING BE PROVIDE AT THE COLD JOINT BETWEEN
THE DECK AND THE CMS TO PREVENT WATER INTRUSION. RECOMMEND
WATERPROOFING BE PROVIDED 1" BEYOND THE SLIDING GLASS DOOR
PERIMETER SEALANT TOWARD THE INTERIOR; 1" ON THE DECK OUT FROM THE
RETURN; 2" OUT AWAY FROM THE CMU; AND SIX TO EIGHT INCHES UP THE
EXTERIOR FACE OF THE WALL
RECOMMENDED 3/4" X 3/4" SILICONE CANT PRIMER. IF REQUIRED CANT BEAD
TO BE PROVIDED AFTER STUCCO AT THE JUNCTION OF THE CONCRETE SLAB
AND THE EXTERIOR FACE. CANT BEAD TO TIE INTO THE SLIDING GLASS DOOR
PERIMETER SEALANT.
VULKEM TRAFFIC COATING TO BE
USED ON BALCONY SURFACES
MEMBRANE
WATERPROOFING
STUCCO
CANT BEAD
SLIDING GLASS DOOR
FRAME SILL
CONCRETE BLOCK
06 WATERPROOFING @ BALCONY NTS 02 STAIR RAIL DETAIL 3/4" = 1'-0"
03 WOOD BALCONY RAILING DETAIL 3/4" = 1'-0"
D1 TYPICAL 2-STORY WALL SECTION 3/4" = 1'-0"D2 TYPICAL 3-STORY WALL SECTION 3/4" = 1'-0"
TOP OF BEAM
@ +23'-0" A.F.F.
HARDWOOD
RISERS
HARDWOOD
TREADS
DECORATIVE
HARDWOOD SKIRTBOARD
WOOD
STAIRS
HARDWOOD BALUSTERS
SPACED TO REJECT
4" DIAMETER SPHERE
GRASPABLE TOP RAIL PER
N.F.P.A. 101 5-2.2.4.5 (C)
HARDWOOD BALUSTERS
SPACED TO REJECT
4" DIAMETER SPHERE
NEWEL POST
TANDEM CAP @
NEWEL POST
R 311.5.6 HANDRAILS SHALL BE PROVIDED
ON AT LEAST 1 SIDE OF EACH STAIRS &
SHALL BE CONTINUOUS FOR THE FULL
LENGTH OF THE FLIGHT
UPPER STAIR - RISE=7.09", RUN=11"
LOWER STAIR - RISE=6.95", RUN=11"
3
4" GYPSUM TOPPING ON 3
4" T&G
PLYWOOD GLUED & SCREWED TO
FLOOR TRUSSES. (PLACE PLYWOOD
PERPENDICULAR TO TRUSSES)
5
8" GYPSUM BOARD CLG ATTACHED
TO BOT CHORD OF TRUSSES OR
METAL FRAMING @ SOFFITS
24" DEEP PRE-ENG FLOOR
TRUSSES @ 24" O/CMAX2'
0
P.T. 1x3 FIRESTOP CONT.
P.T. 1x4 CONT.
TOP OF BEAM & 1ST FLOOR
ELEV 0'-0"
TOP OF BEAM
@ +11'-4" A.F.F.
F1
A802
MIN 8"x8" BOND BEAM
SEE STRUCTURAL PLANS)
P.T. 1x3 FIRESTOP CONT.
RATRUN RESTRAINTS
SEE STRUCTURAL PLANS)
SEE ANCHOR SCHEDULE
ON STRUCTURAL PLANS
FOR ROOF TIE DOWNS
SEE SHEET A802 FOR
TRUSS END DETAILS
PRE-ENG. ROOF
TRUSSES @ 24" O/C
5
8" GYPSUM BOARD CLG ATTACHED
TO BOT CHORD OF TRUSSES
12
4 1/2
8"x16" BOND BEAM
SEE STRUCTURAL PLANS)
SEE STRUCTURAL PLANS
FOR PILING, GRADE BEAMS,
FOUNDATION DETAILS
GRADE VARIES
3/4" RECESS
FILLED CELLS w/ VERT. DOWELS
SEE STRUCTURAL PLANS
FOR SIZES & LOCATIONS)
GARAGE/LOBBY @
ELEV -14'-10"/-11'-0"
P.T. 1x4 CONT.
5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION
STAPLED TO P.T. 1x2 FURRING @ 24" O/C
MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED
OPEN CELLED FOAM INSULATION THAT PASSES
ACC 377 APPENDIX 'X' WITHOUT A COATING
MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED
OPEN CELLED FOAM INSULATION THAT PASSES
ACC 377 APPENDIX 'X' WITHOUT A COATING
3
4" GYPSUM TOPPING ON 3
4" T&G
PLYWOOD GLUED & SCREWED TO
FLOOR TRUSSES. (PLACE PLYWOOD
PERPENDICULAR TO TRUSSES)
5
8" GYPSUM BOARD CLG ATTACHED
TO BOT CHORD OF TRUSSES OR
METAL FRAMING @ SOFFITS
24" DEEP PRE-ENG FLOOR
TRUSSES @ 24" O/CMAX2'
0
P.T. 1x3 FIRESTOP CONT.
P.T. 1x4 CONT.
TOP OF BEAM & 1ST FLOOR
ELEV 0'-0"
8"x16" BOND BEAM
SEE STRUCTURAL PLANS)
SEE STRUCTURAL PLANS
FOR PILING, GRADE BEAMS,
FOUNDATION DETAILS
GRADE VARIES
3/4" RECESS
FILLED CELLS w/ VERT. DOWELS
SEE STRUCTURAL PLANS
FOR SIZES & LOCATIONS)
GARAGE/LOBBY @
ELEV -14'-10"/-11'-0"
P.T. 1x4 CONT.
5/8" GYP BOARD OVER R4.1 FI-FOIL INSULATION
STAPLED TO P.T. 1x2 FURRING @ 24" O/C
MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED
OPEN CELLED FOAM INSULATION THAT PASSES
ACC 377 APPENDIX 'X' WITHOUT A COATING
3
4" GYPSUM TOPPING ON 3
4" T&G
PLYWOOD GLUED & SCREWED TO
FLOOR TRUSSES. (PLACE PLYWOOD
PERPENDICULAR TO TRUSSES)
5
8" GYPSUM BOARD CLG ATTACHED
TO BOT CHORD OF TRUSSES OR
METAL FRAMING @ SOFFITS
24" DEEP PRE-ENG FLOOR
TRUSSES @ 24" O/CMAX2'
0
P.T. 1x3 FIRESTOP CONT.
P.T. 1x4 CONT.
TOP OF BEAM & 2ND FLOOR
@ +13'-0" A.F.F.
8"x16" BOND BEAM
SEE STRUCTURAL PLANS)
MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED
OPEN CELLED FOAM INSULATION THAT PASSES
ACC 377 APPENDIX 'X' WITHOUT A COATING
F1
A802
MIN 8"x8" BOND BEAM
SEE STRUCTURAL PLANS)
P.T. 1x3 FIRESTOP CONT.
RATRUN RESTRAINTS
SEE STRUCTURAL PLANS)
SEE ANCHOR SCHEDULE
ON STRUCTURAL PLANS
FOR ROOF TIE DOWNS
SEE SHEET A802 FOR
TRUSS END DETAILS
PRE-ENG. ROOF
TRUSSES @ 24" O/C
5
8" GYPSUM BOARD CLG ATTACHED
TO BOT CHORD OF TRUSSES
12
4 1/2
MIN R-20 1/2 lb. PER CUBIC FOOT SPRAY APPLIED
OPEN CELLED FOAM INSULATION THAT PASSES
ACC 377 APPENDIX 'X' WITHOUT A COATING
01 INTERIOR FRAME WALL (NON BEARING)1 1/2" = 1'-0"
NOTE:
P.T. 2x4 FRAMING AROUND
ALL SHOWER OPENINGS
BATT INSULATION FOR WALLS
BETWEEN CONDITIONED and
UNCONDITIONED SPACES, AT
OPT. LOCATIONS FOR SOUND-
SEE PLANS
35 8" METAL STUDS
25 ga) @ 24" O/C
35 8" METAL RUNNER
TRACKS (25 ga) TOP & BOTFORFIRERATED & ADJACENT WALLS:
TOP & BOT RUNNERS TO BE FASTENED TO
CEILING & FLOOR @ MAX 24" O/C w/ 5/8"
EMBED NAILS OR SELF TAPPING SHEET
METAL SCREWS FOR METAL TO METAL
5/8" GYP BOARD w/ A
LEVEL 4 FINISH OR
5/8" DUROCK @ WET AREAS
GENERAL NOTE SPECIFICATIONS:
ALL CONCRETE SHALL BE OCEAN MIX
ALL NAILS SHALL BE GALVANIZED
ALL FASTENERS SHALL BE STAINLESS STEEL
GENERAL NOTE SPECIFICATIONS:
ALL CONCRETE SHALL BE OCEAN MIX
ALL NAILS SHALL BE GALVANIZED
ALL FASTENERS SHALL BE STAINLESS STEEL
04 ALUMINUM GUARD DETAIL 3/4" = 1'-0"
3'
0
112"x112" SQ
PICKET
TYP.)
2"x2" SQ
VERTICAL
TYP.)
612"
3
1
2 "
TOP CAP ON
2"x2" TUBE
08 ALUMINUM GUARD DETAIL 3/4" = 1'-0"
3'
0
TOP CAP ON
2"x212" TUBE
NOTE:
ALL FASTENERS FOR RAIL ATTACHMENTS
TO BE STAINLESS STEEL
2" x 2" SQ
PICKET
2" x 2" SQ
PICKET
12" DIA SOLID
ALUM ROD
TYP.)
NOTE:
PICKET SPACING TO
REJECT 4" DIA. SHERE
3
1
2 "
INSULATION NOTES:
1. ALL INSULATION TO COMPLY w/ FBC 2017 R302.10 FOR
FLAME SPREAD & SMOKE DEVELOPED INDEX.
2. FLAME SPREAD INDEX NOT TO EXCEED 25.
3. SMOKE DEVELOPED INDEX NOT TO EXCEED 450.
INTERIOR WALL & CEILING FINISH NOTES:
1. ALL INTERIOR WALL & CEILING FINISHES TO COMPLY w/ FBC 2017
R302.9 FOR FLAME SPREAD & SMOKE DEVELOPED INDEX.
2. FLAME SPREAD INDEX NOT TO EXCEED 200.
3. SMOKE DEVELOPED INDEX NOT TO EXCEED 450.
NON-SKID FLOORING ON
EPOXY BASED SETTING MATERIAL
GROUT OVER TRAFFIC COATING
NO PHOSPHATE BASED MORTAR)
BULLNOSE
EDGE
SMOOTH STUCCO
FINISHED BALCONY
TRAFFIC COATING
05 BALCONY EDGE DETAIL NTS
WATER DRIP
GROOVE
07 EXTERIOR RAILING ATTACHMENT NTS
4"
MIN POST EMBEDMENT = 4"
3 1/4" DIA x 4" DEEP HOLE
INTO CONCRETE, FILL HOLE
w/ EPOXY BONDING/GROUTING
ADHESIVE (SIKADUR 32 HI-MOD)
RAILING POST (REFER TO SHOP
DRAWINGS FOR SIZE & LOCATIONS)
4" MIN EDGE
DISTANCE
1 D3
INTERIOR NON-BEARING
BREAKAWAY WALL CONSTRUCTION
1 1/2" = 1'-0"
35 8" METAL STUDS
25 ga) @ 16" O/C
35 8" METAL RUNNER
TRACKS (25 ga) TOP & BOT2x4NAILEDTO
FLOOR TRUSSES
2) 16d each truss)
NORMAL
MATERIALS
FLOOD PROOF MATERIALS
CLASS 4 OR 5 PER FEMA
TECHNICAL BULLETIN #2)
P.T. 2x4 w/ 1/4" x 3"
CORROSION RESISTANT
TAPCONS @ 16" O/C
No. 6 x 1" GALV SCREWS
@ 32" O/C TO BOT PLATE
DESIGN FLOOD
ELEVATION (DFE)
SEE PLANS
No. 6 x 1" GALV SCREWS
@ 32" O/C TO TOP RUNNER
1
THIS DESIGN ALLOWS THE METAL FRAMED WALL
TO BREAKAWAY FROM THE PERMANENT TOP &
BOT 2x4 RUNNERS WITHIN THE 10-20 PSF LOADING
RANGE WITHOUT HARM TO THE ELEVATED PORTION
OF THE BUILDING OR SUPPORTING FOUNDATION
EAST COAST METAL
STANDING SEAM METAL ROOF
OVER TAMKO ASTM TYPE 2
30# FELT OVER GAF VERSASHIELD,
TIN TAG FELT TO APA 40/20 19/32"
EXPOSURE 1 PLYWOOD
EAST COAST METAL
STANDING SEAM METAL ROOF
OVER TAMKO ASTM TYPE 2
30# FELT OVER GAF VERSASHIELD,
TIN TAG FELT TO APA 40/20 19/32"
EXPOSURE 1 PLYWOOD
2
2
AC
Q
U
A
V
I
S
T
A
L
O
T
1
VE
N
E
T
I
A
N
A
D
M
I
N
I
S
T
R
A
T
I
O
N
L
L
C
4.
2
0
2
0
2
0
ob No. 1802011
IBO GS 4.17.2018
ENG REV'S GS 8.6.2018
1 1st Bldg Comments GS 3.1.2019
2 As built roofing GS 4.20.2020
A801