Loading...
HomeMy WebLinkAboutProduct approvals, 5 V Metal BCIS Home Log In User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I ,Search a a Product Approval b 10%r USER:Public User :?cySS�f35=b'i Product Approval Menu>Product or Application Search>Aoolintion List>Application Detail FL# FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived - I Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen Flvalidation@yahoo.com I Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer J Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. d; Validation Checklist- Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 I Equivalence of Product Standards Certified By (i 1. i Product • • 2160 SW Poma Drive Palm City, FL 34990 .... .... 772 872 8034 Florida • . . NON HVHZ f Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule #61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 I:. Yield strength: 50 ksi min.; Attached to min. 15/32"plywood or Wood Deck w/min.0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8"embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, &4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16 min. thru deck or 5/8 embedment into wood plank. (*or sufficient length to meet requirements) q ) Underla ment: To be compliant with FBC Sec. Chart 1507.1.1 Y P Slope: Shall be in compliance with FBC Sec. 1507. See Install Details: Table A Allowable Loads METHOD 1 Fastener attachment specifications above — — _._ .. _..... _ _METHOD2 METHOD 3..... ..METHOD 4 DESIGN PRESSURE* 86 PSF -93.5 PSF -101 PSF _228 PSF _ ROW SPACING..._ _..... .. .. ...:.... ... . 16"_o.c. 16"O.C. _....8"O.C. _ 6"o.c.i _ FASTENER SPACING..(ALONG_Panel width.).. . ...12"o.c. 12".o.c. _..-.__ 12"ox. 12"o.c FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527 UL 580-06& 1897-041 Test Report IM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 0 /22/14 I *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 �t 1 *Design pressure margin of safe 2:1 U, Locke Bowden,P.E.does not have,not will acquire a financial ina- OWfacturing or distributing products under this evaluation. Locke Bowden,P.E.is not owned,operated,or controlled by ati cor)I rnbr%or distributing products under this report. ; cC * T 'S r�C�� f 7' + � _ i i i FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 fo' Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. Fasteners- 91 X1-112'Min.or *10 x 1-112'Min.per UM A'for Row 5-V Crimp Roof Panel Spacingand Design Pressures Hex Washer Head Wood Screws v V Deck -15!32"or greater Plpo ,or -Wood plank 24- ma 12' 318" o>�rtorew_stRv�noNs� Panel Profile Nominal 12" Nominal 12" O.C. O.C. Fasten #9 x 1-1/2"Min. or #10 X 1-1/2"Min.per Table"A" Hex Washer Head Screw Spaced 12"o.c.across the Panel Width Panel Refer to Table"A"for Spacing Along Panel Overlap Length Deck-15/32"or greater Plywood,or -Wood plank i