Loading...
HomeMy WebLinkAboutPERMIT PACKAGEAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: • Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT TYPE: (% PROPOSED IMPROVEMENT LOCATION• Address: 1584 NW SWEETBAY CIR Property Tax ID #: 4426-803-0034-000-2 Site Plan Name: ARMSTRONG Project Name: ARMSTRONG DETAILED DESCRIPTION OF WORK: tx I LRIOR LP GAS TANK AND LINES CONSTRUCTION INFORMATION: Permit Number: Building Permit Application Commercial Residential X Additional work to be performed under this permit —check all that apply: _Mechanical (YGas Tank KGas Piping _Shutters _ Electric _ Plumbing Total Sq. Ft of Construction: Cost of Construction: $ 2000 _ Sprinklers Generator Sq. Ft. of First Floor: Utilities: _ Sewer _ Septic Lot No. Block No. Windows/Doors - Roof Pitch Building Height: OWNER/LESSEE: CONTRACTOR: NameElaine M Armstrong (TR) Name: Cheyenne Ellison Address:1584 NW SWEETBAY CIR Company: Elite Gas Contractors City: Palm City State: _ Zip Cade: 34990 Fax: (772)220-1829 Phone No.(772)220-9678 Address:2130 Poma Drive City: Palm City State: FL Zip Code: 34990 Fax: (772)220-1829 Phone No(772)220-9678 E-Mail:emcintosh@elitegasco.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) If value of construction Ic bsnn ,,..,,. � nrrr,n ._.:_ E-Mail emcintosh@elitegasco.com State or County License 18361 — If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: -- •- ••�. f ..,�fr�cR: _ Not Applicable [Add ORTGAGE COMPANY: Name: Not Applicable Address: me: City: ress: State: Zip: Phone Y Phone: State: FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: Name: — Not Applicable Address: Name: City: Address: Zip: Phone: City: Zip: Phone: OWNER CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. which is ne onflictawith any applicable (on Hothat e Owners Association) rwill esauthorize by bylaws or anScovenants that build or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YYOOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." ZeK- k — na e o caner/ Lessee/Contractor as Agent for Owner sign of Co ractor/License Holder STATE OF FLORIDA STATE OF FLORID COUNTY OF G ✓7�i lit COUNTY OL /-f The forgoing instrume t was ayknowledged before me The for oing instrume was a nowledged before me this day of , 20— . this day of 20,20by rvarne or arson making statement.�_��, / Name of pe on making statement. Personally Known V OR Produced Identification Personally Known Type of Identification YgsOR Produced Identification Type of Identification Commission No. REVIEWS Notary Public State of Ronde Desiree t11�t�Grlgtosh MYCOMM G 283399 Expires 12/11=22 (Signature of Commission No. FRONT VING PLANSCOUNTER R VI W SREVIEWOR REVIEW I VREVIEEGETAWON Notary Public Sta a of Florida Desiree N;SOHitsh My COMMISalpe GG 283399 Expires 12/1112022 SEA TURTLE I MANGROVE REVIEW REVIEW Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: Parcel ID: Account #: Map ID: Use Type: Zoning: City/County: Ownership Elaine M Armstrong JR) 1515 Lancewood TER Palm City, FL 34990 Legal Description HARBOUR RIDGE -PLAT 8- SWEETBAY VILLAGE UNIT I I AND THAT PART OF GOLF COURSE 4 MPDAF: BEG NE CDR OF UNIT 11, TH S 87 56 14 E 20.01 FT, TH S 04 07 33 W 98.45 FT, TH N 83 45 29 W 20.01 FT, TH N 04 07 33 E 96.99 FT TO POB (0.29 AC - 12,632 SF) Current Values Just/Market Value: $217,600 Assessed Value: $217,600 Exemptions: $0 Taxable Value: $217,600 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collectors Office Download TRIM for this parcel: Download PDF 1584 NW SWEETBAY CIR 4426-803-0034-000-2 119423 44,26N 0100 Planned Un Saint Lucie County Total Areas Finished/Under Air (SF): 2,178 Gross Sketched Area (SF): 3.530 Land Size (acres): 0.28 Land Size (SF): 12,362 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. PIPE ..AND TUBING SIZING TABLES 58-97 Table 15.1(o) Polyethylene Plastic Pipe Sizing Benveen First -Stage and Second -Stage Regulators: Nominal Outside Diameter (1PS) Gas: Undiluted Propane Inlet Pressure: 10.0 psi Pressure Drop: 1.0 psi Specific GraNity: 1.52 Plastic Pipe 54 in. s/4 in. 1 in. I45 in. 1''A in. 2 in. Length SDR 9.33 SDR 11.0 SDR 11.00 SDR 10.00 SDR 11.00 SDR 11.00 (ft) (0.660) (0.860) (1.077) (1.328) (1.554) (1.943) 30 2143 4292 7744 13416 20260 36402 40 1835 3673 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 1 60 1473 2950 5322 9220 13924 25019 70 1355 2714 4896 8483 12810 23017 80 1261 2525 4555 7891 11918 21413 90 1183 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1983 3578 6199 9361 16820 6Y'150 897 1797 3242 5616 8482 15240 175 826 1653 2983 5167 7803 14020 200 778 1539 2775 4807 7259 13043 225 721 1443 2603 4510 6811 12238 250 681 1363 2459 4260 6434 11560 .J 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4989 8965 450 495 992 1789 3100 4681 8411 500 468 937 1690 292S 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4385 2000 221 443 798 1383 2089 3753 _ IPS: Iron pipe size. SDR Standard dimension ratio Notes: p) Capacities are in 1000 Bm/hr. t2) Dimensions in parentheses are inside diameter 2014 Edition STOZ `OE aunt palepdn •lassaA aqj jo 1111 Isig pallldwls alqeua oa pa8ind-aid wnn3eA padd14s aie slassaA II`d - •awop 9n/gd laals 4jlm pallddns'Tew dol aueglain Aq pamollo; }eon iawlid Axoda palldde pinb!I io 4slug ialsaAlod j191 paleo3 iapmod ia4:la 41!m paTeo:)'uolTdo punoiSanogy :Z uol;dp •awop gn/gb allsodwo:) 4:1m pallddns Ilea) doh aue4lain Aq pamollol jew iawlid Axoda palldde pinbl) io 4slug Axoda 311oua4d pajew iapmod ia4}la 411m pajew'uondo punoi8iapun Ainq-of-Apeall :Z uoudp :algellene suo!1do axuuas om1- •pieog IeuolIeN qj!M paia:sl8ai slassaA IId • j oSZT o} j DOZ- woi j 8lsd OSZ le pa4ea - -SS ddjN 411m sa!ldwo:) •T uolslAlo 'IIIA uolPaS'slassaA ainssaid 10 uolj3nijsuo0 iol salna 31NSV 10 uolIIpa IsaM 84101 swiojuo:) - suolje:)Up5 S Ieiaua!D -slleiap jol uosiadsales snoA 43!m )Pa4O Su!dd!4s Aq ANeA sa!iliuenb Tools pue pool pnj ,. -anoge umc4s se do pue *VM OSdT 'jaiuw uo „91 S0104 Z - duel PaePui4s •S+M► OOOT Pue OOS •(isanbai ua alo4 Jaluaa auo) s881 ul s8104 ou - quel Paopueis ,qm OZE ,OSZ'OZT -sllepP iol uosaadsales inoA 4l!en )pa4:) •uo.4ml -E4w uo paseq Alen Aew Eu!aeds pue s4Mm^ Sal •„Z /+ 3uneds Sal , •AjeA Aew slassaA lenpinlpu{ •alew!xoidde aje wsno4s suogeo!;pads pue suolsuawlp b fr 8 ZT OZS'£ 0S9'Z 19T „L-,TT „6-,T „6-,T „TT-,b „TT-,b „TT-,EZ „tr-,LT -d1113 •d!113 „Z/T 9V „Z/T 9ti •8m 066T -8m OSVT S 1 9 ST I LT Oa8`T „T-,OT 118-,T „S-,ti ,9T •lwaH „TV Im 000T 918 0£ I L£ OS6 ,S „8-,T „Z-,fi ,OT •!waH „ Z/T LE •8m OOS 6 Str OZ9 ,S „S-,T „8-,€ „L-,6 •!waH „OE •8m OZ£* 6 tr5 08V „TT-,tr „S-,T „8-,£ „OT-,L •1WaH „0£ '8m OSZ* ZT 19T 96 180T 09Z „TT-,€ io „Z/T OT-,Z ,Z/T T-,T ,E „8-,S •d!113 „tiZ '8m OZT* MIS aid adoi -nn3 ('sq!) 1H913M 9N10ddS **931 H1aIM *931 1H913H 11VZI3AO H19N31 i1d213AO 3dA1 aV3H (QO) b313Wd1a All0ddV:) H31VM "JLNdnb** SNOIldJIj103dS CINd SNOISN3WIo 13SS3A (9n/9V) aNnOH93aNn/aNnOV 3AOsn 3lnwlxO!Iddv do (INV •8M Or.*L que.L auedoad E)n/E)d uoijeaodao:) jaajS Aillenja FA 7 r i * tow . 1 -i . l :� , . • 1 • 'f f I I f �I `rri::�'j±j: f •-•�, ! •�:•1�-----1 j ' •j Pro - . - !�i".::}r .:—Irr—•a. ,.,.. ,;r' :..., -.r�l:== Ili��� - PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and inside building shall be SCH..40 Galvanized ASTM A120 or AGA approved.corrugated stainless steel (C.S.S.T.)pipe'. 2. All. polypipe and fittings shall be ASTM 13251.3 or ASTM D2517 and shall be b un*ed -outside underground at a depth of 18" with warning tape and tracer wire. 3. All pipe and meter locations are approximate and subject to change.. .4. All polypipe shall be joined by heat fusion or approved mechanical . couplings* 5. Ail 'galvanized pipe shall be threaded. G: All. pipe- shall be' pressure tested to 20 # PSI for a period of 24 hours. a�rx awas - - • tOlAU3S - u3HlYllloo swo-11 allnouoUaona - o• _I of jr O o - • • • I ,n 04+ I 0 O • 0• • • • ' • O • •O • p ' • � O � I �3J�33'ZS8S32iDN0�/3QY210 - . 3dv.L all XUVA ' ii3 S121 3 avu� V j4J 3AFIVA 3 a•I&hn-0 ,Lv 330 SYD IMIS Als �• �ra WnlsaNsbw) • •• •: _ • , - •�.�` : • • 300NV l VIOI:J l*lf3VS .• r '•• BISVO 30ONV I /A a e•, �••9NI 'MI�I . kvmv 030tyil0NM00 .� .9 01 »z NOI�.d-I-IV-LSNi NNdi ONnoaDa3aNn • '_:'•L ' Bulletin LP-T R122H March 2010 Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Two -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life — The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both internally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps — Built-in V8 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability — A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation — A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation — The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. FISHER Figure 1. Type R122H First -Stage Regulator Superior Overpressure Protection — The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with a R622 or R652, the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. • Corrosion -Resistant — Added corrosion resistance from an intemal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. • Positive Draining Spring Case —When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. EMERSON Process Management Bulletin LP-7: R122H Table 1. Ordering Information TYPE NUMBER CAPACITY BTU1HR PROPANE01 CONNECTIONS INLET x OUTLET NOMINAL OUTLET SETTING R122H-AAJ 1.100,000 1/4-inch x 1/2-inch NPT 10 pslg (0,69 bar) 1 Cal)Wt r Is based on 30 PSIG (2.07 tsar) mtei pressure and 20% droop, 1/4-18 NF M^ Figure 2. Type R 122H Dimensions INCHES (mm) LP -Gas Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872 USA Telephone: 1 (800) 558-5853 Telephone: 1 (972) 548-3574 For further information visit www.fisherregulators.coml[p The Emerson logo 1s a trademark and service mark of Emerson Electric Co All other marks are the property of then prospective owners, Fisher is a mao owned by Fisher Controls bus , Inc.. a iness of Emerson Process Mannement, The conte is of Oft publication are presented for btfornaborssl purposes only, and while every effort has been made to ensure thew accuracy, they are not to be construed as warranties or guarantees, eWess or Implied, regarding the products or senrtces described herein or their use or applicabilitywe reserve the right to modify or improve the designs or specMeaft s of such Products at any Grne without notice. Emerson Process Managemert does rot assume respormutry for the selectors, use or maintenance of any product. Responsibility for proper selection. use and marntenance of Process Management product remains solely with the Purchaser. airy Emerson EMERSON_ OErttersotu Process Management Regulator Technologies, Inc., 2003, 2010: All Rights Reserved Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Comp • Protei Scree • Winh r'nnarltY/ • Inlet and Outlet Pressure Gauge Taps Figure 1. Tyl,a R132;' Fecsura Ro,hw: ro Rc�qula Aa Introduction Relief Jeight Type R622 direct -operated. spring -loaded regulators applications. These regulators can be used with provide economical pressure reducing control in natural. manufactured. or propane gases and have the a variety of residential. commercial. and industrial same inlet and outlet pressure capabilities. c FISHER EMERSON. Bulletin 71.1: R622 Specifications Body Size and End Connection Style() Pressure Registration 112 NPT inlet and outlet Internal Maximum Allowable Inlet Pressure() Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure() Operating to Avoid Internal Part Damage: 3 psid (0,21 bar d) above outlet pressure setting Emergency: 20 psi (1.4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/8-inch (3,2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open C„ for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients XT: 0.78 FD: 0.82 FL: 0.89 Flow Capacities See Table 2 Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature CapabilitiesM -200 to 160OF (-290 to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: Delrin® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1. The pressu M mperahtfe unm in tnis Bunehn or any appkcable standard lmvtaWn should not oe exceeded. Mn ea n mah ca miaA by F 1. du Pant de NemOUr9 and CO _-- In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 1. Outlet Pressure Ranges Specifications The Specifications section lists specifications for Type R622 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER. INCHES (mm) SPRING FREE LENGTH. INCHES (mm) 1.8 to 2.2-tnches w.c. (4 to 5 mbar) T 14453T0012 Purple 0.051 (1,30) 3.40 (86.4) 5 to 7-arches w.c. (12 to 17 mbar) T 14398T0012 Orange 0.062 (1,58) 3.40 (86.4) 6.5 to 9-mches w.c_ (16 to 22 mbar) T 14399T0012 Yellow 0.067 (1,70) 3.61 (91.7) 9 to 13-mches w c. (22 to 32 mbar) T 14400T0012 Stiver 0.072 (1,83) 4 10 (104) 13 to 204nches w.c. (32 to 50 mbar) T 14401 T0012 Gray 0080(2,03) 360(91.4) 16 to 35-inches w c. (40 to 87 mbar) T14402T0012 Pink 0.093 (2,36) 3.52 (89.4) 1 to 2.2 pstg (69 to 152 mbar) T14403T0012 Ught Blue 0 105 (2,67) 3.66 (93,0)