Loading...
HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce, FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner: v-5aN- 7 LY oa-E VI LLA167'E Date: i 7 19 (Print or type) I 5 / i)/`rG Address: Year/ Mz W idth_a-�r__ C = In Compliance N = Not in Compliance FL ouNTRY CLua FLEA 321115 - , HUD Plate # L R Y1 Double_ Wind Zone J�-- Fire Safety / Electrical 1. Smoke Detector: Installed Missing C 2. Electrical System Checked: Exposed Wiring ___Other r_ 3. Distribution Panel: Missing _ Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other /- 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ �L 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 319105 Page I of 3 C 1. Exit Doors Operable: Frc 2. Exit Door Locks: Missing C_ 3. Egress windows: Missing Construction Inoperable _ Inoperable C4. Windows: Broken Glass Inoperable Other 5. Screens: Missing Damaged_ L 6. Floor System: Joist Decking Area Damaged �. 7. Interior Paneling: Missing_ Loose— Damaged_ C 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other 9. Leaks Apparent: Ceiling— Doors_ Floor_ Roof_ 10. Vertical tie -down straps: Missing_ Short_ Damaged_ 0 11. Structural modifications since manufactured: YES_ NOY _C 12. Walls: Structurally Unsound —Loose —Weather tight Plumbing SL 1. Trap: Missing Not connected Other 6 2. Plumbing fixtures: Missing _ Not installed _ Not Vented _C, 3. Relief Valve: Missing Inoperable Other _jC, 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other Ci 2. Deleted Heating/AC system: Not installed Other 1 3. Thermostat: Missing Inoperable C 4. Air registers: Missing Inoperable C 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 _jj�— 6. Gas fumace Water heater vent: Missing 7. Return Air: To Furnace To A/C 8. Range: Vent Hood Loose From rooms 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Notbonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO V 2. Willa remodeling permit be required? YES NO V/ The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320,8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: l a /7 1 9 Inspected By: .F. �_ Sig Wrs requlred3 a Phone Number:l(�/'!/�+J 1 THEIR SEAL. License # 3' 358 Page 3 of 3 iww/ /a/-711F Engineers Seal STEVEN G. WOOD, P.E. iFL LICENSE 34398 950 SULTAN DR PORT ST LUCIE, FL