HomeMy WebLinkAboutProject Information- wrightsoft° Project Summary o te1 Entire House ey: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 PInre: 772-466-6799 Emil: OUICKCALCS@AOL.COM Project Information For. WINDSONG MOBIL L-LAGEw 3200 S. 7tH STRE LOT'#t30wFT. PIERCE, FL 34982 Notes' aaoa-d\q4 Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16000 Btuh Structure 21584 Btuh Ducts 4881 Btuh Duds 7011 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfin) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 20881 Btuh Use manufacturers data n Rate/swingg multi Equipmentsensibleload 0.95 27165 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2552 Btuh Duds 1886 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool ingg (none) Area (ft�) 1164 1164 Equipment latent load 4438 Btuh Volume (W) 10942 10942 Airchangesnlour 0.45 0.23 Equipment Total Load (Sen+Lat) 31604 Btuh Equiv.AVF (cfm) 82 42 Req. total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GPC1442M41A AHRI ref Coil AHRI ref 201186877 Efficiency 100 EFF Efficiency 11.0 EER,14 SEER Heating input 5.4 kW Sensible cooling 28000 Btuh Heating output 18335 Btuh Latent000ling 12000 Btuh Temperature rise 13 OF Total cooling 40000 Btuh Actual airflow 1333 cfin Actual airflow 1333 cfin Airflowfador 0.064 cfmBtuh Airflowfactor 0.047 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCAto meet all -Fk- wrightsoft^ 2020-Feb-2893:17:04 11 •�'^--_•,•°--•�^ Rigtt-SJfeQUNvem1201919.0.07RSU08101 Paget _.rtAWrig%oftWAQWINDSONG MOBILE LOTN30A;) Ca1c=MI8 FrortDoorfaces:SE rFr wrightsoftght-M Worksheet Job: • Ri Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House LOT 45 2 3 Exposedwall Room height 166.0 it 9.4 it 90.0 It 9A ft heatl000l 4 5 Room dimensions Room area 1164.0 ft' 12.0 x 52.0 it 624.0 fe Ty Construction number U-value (Bh:hAF-'F) Or HTM (Btuw) Area (ft') or perimeter (it) Load etch) Area (ft') or perimeter (it) Load (Btuh) Heat Cod Gross NtP/S Heat Cool Gross NIPS Heat cod 6 vf/ L--C 12BOsw 1Aclom 12Mw 0.097 1270 0.097 n n a 272 3556 2.72 2.34 34.77 2.34 11 226 - 20 555 206 0 513 558. 711 1392 481 695 1198 113 20 489 93 0 447 252 711 1214 217 695 1044 W, 11 —G W 1Aa1om 12B-03,u 1270 _ . 0,097 a -s 35.56 2.72 86.05 2.34 42 226 4 ' 226 1.494 613 3614 527 42 113 4 113 1494 306 3614 264 Ut/ 12B-0sv 1Ac1om 1Aciom 0.097 1270 1270 w w w 2.72 3556 35.56 2.34 86.61 86.61 555 13 18 497 1 1 1349 453 640 1161 1104 1559 132 0 0 132 0 0 357 0 0 308 0 0 c 1Aclom '17B-20zl - 1270 ,0.043 w 35.56 120 86.61 1.03. 27 1164. 2 1164 960 1401 2339 1201, 0 624 0 624 0 751 0 644 F 19A-0bsvo 0.368 3,35 1.80 1164 1164 3903 2091 624 624 2092 1121 6 c)AED excursion 802 -887 Envelope loss/gain 13475 16773 7178 7020 12 a) Infiltration 2525 691 1369 375 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 4 920 Appliancestother 3200 2000 Subtotal (lines 6 to 13) 16000 21584 8547 10315 Lem external load 0 0 0 0 Lesstransfer Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 16000 21584 8547 10315 15 1 Dudloads 31% 32%1 Q81 7011 31% 32% 2607 335D Total room load Air reired(dm) qu 20881 1333 28595 1333 11154 712 13665 fi37 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wrightsoR•' 2020-Feb-2813:17:04 RCLA Riglt-Sute®Urvversal 201919.0.07 RSU08101 Page l ...rLs\WrlglisoftWAQWINDSONG MOBILE LOT430.nip CaIc=MJ8 Front Door faces: BE Fiji- wrightsoft- Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. aY 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: QUICKCALCS@AOLCOM 1 Room name LOT 2 Exposedwall 76.0 ft 3 Room height 9.4 ft heatlmol 4 Room dimensions 12.0 x 45.0 ft 5 Room area 540.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area Load number (BtuW-T) (BWh4l) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cod 6 Ut/ I—C 12B-Osw. 0.097 n '272 2.34 '.. 113 113 306 264 1Ac1om 1270 n 36.56 34.77, 0 0 0' 0 V)/ 12B-0sv 0.097 a 2.72 2.34 66 66 179 154 �C 1A-dom 1270 a 35.56 86.05 0 0 0 0 11 w 12B-0sv 0.097 - s " 2.72 - 2.34 113 113 306 264 126-0sw 0.097 w 2.72 2.34 423 365 992 854 1A-dom 1.270 w 35.56 86.61 13 1 453 1104 1A-dom 1270 w 35.56 86.61 18 1 640 1559 10-clom 1270 w 36.56 86.61 27 2 960 2339 "C ,17B-20zl 0.043 120 '1.03 - 540 540 650 557' F 19A-0bsup 0.368 3.35 1.80 540 540 1811 970 6 C)AEDexcvrsion 1689 Envelope losslgain 6298 9753 12 a) Infiltration 1156 317 b) Roomventilaton 0 0 13 Intamalgains: Occupants@ 230 0 0 " Appliances/olher 1200 Subtotal (lines6 to 13) 7454 11270 Lessedernalload 0 0 Lesstransrer 0 0 Redistibution 0 0 14 Subtotal 7454 11270 15 Dud loads 31% 32% 2274 3661 Total room load 9728 14930 Air required (dm) 621 696 _ Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -FWwri9htsol't` 2020-Feb-2813:17:04 I&A Rgtt-SLiWOUNveml201919.0.07RSU08101 Paget ...rwwrig%oftWAQWINDSONG MOBILE LOT#30.np Calc=NUB Frort Door faces: BE