Loading...
HomeMy WebLinkAbout5V Crimp for 1-12 Pitch .� 'C tW - Regulation /1 BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search bProduct Approval r 0 USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL14645-R3 SECRETARY Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Metal Sales Manufacturing Corporation Address/Phone/Email 545 South 3rd Street,Suite 200 Louisville, KY 40202 (502)855-4300 dstermer@metalsales.us.com Authorized Signature David Stermer dstermer@metaIsales.us.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Bala Sockalingam Evaluation Report Florida License PE-62240 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/27/2026 Validated By Yoosef Lavi, P.E. ✓ Validation Checklist- Hardcopy Received Certificate of Independence FL14645 R3 COI CertificateIndepgndence.pdf Referenced Standard and Year(of Standard) Standard Year FM 4470 2012 TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/09/2017 Date Validated 09/14/2017 Date Pending FBC Approval 09/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 14645.1 2.5"Corrugated Min. 26 ga.,21.33"wide coverage through fastened roof panel over min. 19/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 1 df Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86.0 Evaluation Reports Other: Uplift load of 82.3 psf at fastener spacing of 36"o.c. FL14645 R3 AE EvaluationReportC2182 i.pdf and 86.0 psf at fastener spacing of 12"o.c. Created by Independent Third Party: Yes 14645.2 5V-Crimp Min. 26 ga.,24 wide through fastened roof panel over min. 19/32"thick plywood deck with fasteners through panel flat. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 2.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-149.6 Evaluation Reports Other: Uplift load of 84.5 psf at fastener spacing of 24"o.c., FL14645 R3 AE Eva IuationReportC2182 2.pdf 131.3 psf at fastener spacing of 18"o.c. and 149.6 psf at Created by Independent Third Party: Yes fastener spacing of 12"o.c. 14645.3 5V-Crimp Min. 26 ga.,24"wide through fastened roof panel over min. 19/32"thick plywood deck with fasteners through panel rib. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 3.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-196.75 Evaluation Reports Other: Uplift load of 41.6 psf at fastener spacing of 36"o.c., FL14645 R3 AE EvaluationReportC2182 3.pdf 74.8 psf at fastener spacing of 16"o.c.and 196.75 psf at Created by Independent Third Party: Yes fastener spacing of 8"o.c. 14645.4 5V-Crimp Min. 26 ga.,24"wide through fastened roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB with fasteners through panel rib. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 4.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-172.5 Evaluation Reports Other: Uplift load of 30.0 psf at fastener spacing of 36"o.c. FL14645 R3 AE Eva IuationReportC2182 4.pdf and 172.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.5 Aluminum Classic Rib Nom. 0.032"thick, 36"wide,aluminum through fastened roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 5.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-120 Evaluation Reports Other: Uplift load of 30 psf at fastener spacing of 36" o.c. and FL14645 R3 AE Eva I uationReportC2182 5.pdf 120 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.6 Aluminum Vertical Seam Nom. 0.032"thick, 16"wide, aluminum standing seam roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 6.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-97.05 Evaluation Reports Other: Uplift load of 41.6 psf at clip spacing of 36"o.c.,71.0 FL14645 R3 AE EvaluationReportC2182 6.pdf psf at clip spacing of 12"o.c. and 97.1 psf at clip spacing of 12" Created by Independent Third Party: Yes o.c.with sidelap adhesive. 14645.7 Aluminum Vertical Seam Nom. 0.032"thick, 16"wide,aluminum standing seam roof panel over min. 19/32"thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 7.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-162.0 Evaluation Reports Other: Uplift load of 41.6 psf at clip spacing of 36"o.c., 100.2 FL14645 R3 AE Eva IuationReportC2182 7.pdf psf at clip spacing of 12"o.c. and 162.0 psf at clip spacing of Created by Independent Third Party: Yes 12"o.c. with support strap. 14645.8 Classic Rib Min. 29 ga.,36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 8.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-91 Evaluation Reports Other: Uplift load of 41.5 psf at fastener spacing of 48"o.c. FL14645 R3 AE EvaluationReportC2182 8.pdf and 91 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.9 Classic Rib Min. 26 ga., 36"wide through fastened roof panel over min. 19/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 9.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-133.9 Evaluation Reports Other: Uplift load of 74.8 psf at fastener spacing of 36"o.c., FL14645 R3 AE Eva IuationReportC2182 9.pdf 92.3 psf at fastener spacing of 24"o.c.and 133.9 psf at Created by Independent Third Party: Yes fastener spacing of 18"o.c. 14645.10 Classic Rib Min. 29 ga., 36"wide through fastened roof panel over min. 7/16"thick OSB deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 10.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-135.0 Evaluation Reports Other: Uplift load of 45 psf at fastener spacing of 24" o.c. and FL14645 R3 AE EvaluationReportC2182 10.gdf 135 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.11 Classic Rib Min. 29 ga., 36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 11.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-138.5 Evaluation Reports Other: Uplift load of 68.4 psf at fastener spacing of 24"o.c. FL14645 R3 AE EvaluationReportC2182 11.pdf and 138.5 psf at fastener spacing of 12"o.c. Created by Independent Third Party: Yes 14645.12 Image II Min. 26 ga., 16"wide concealed fastened roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 12.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86.55 Evaluation Reports Other: Uplift load of 20.8 psf at fastener spacing of 24"o.c., FL14645 R3 AE EvaluationReportC2182 12.pdf 63.5 psf at fastener spacing of 6"o.c. and 86.55 psf at fastener Created by Independent Third Party: Yes spacing of 6"o.c. with sidelap adhesive. 14645.13 PBR-Panel or R-Panel Min. 26 ga.,36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 13.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-131.0 Evaluation Reports Other: Uplift load of 30.0 psf at fastener spacing of 48"o.c. FL14645 R3 AE EvaluationReportC2182 13.pdf and 131.0 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.14 Pro-Panel II Min. 29 ga., 36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R3 II Evaluation ReportC2 182 14.pdf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-71.5 Evaluation Reports Other: Uplift load of 41.6 psf at fastener spacing of 24"o.c. FL14645 R3 AE Eva IuationReportC2182 14.pdf and 71.5 psf at fastener spacing of 12"o.c. Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S..,please click here. Product Approval Accepts: ®® ® ®Check Credit Gard Safe EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.2-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4200 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer#62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (918) 493-3568 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) %a - O C Kq 4/*,o� No 62240 fir • . � � Report No. C2182-2 �:• STATE OF 44, Date: 9.9.17 ,�• Ak- �ii 9 , q. 20 1-7 FL 14645.2-R3 C2182-2 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 131.3 psf @ fastener spacing of 18" o.c. 149.6 psf @ fastener spacing of 12" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between ribs) At intermediate 4 fasteners per panel width. (4 located adjacent to ribs) Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current FL 14645.2-R3 C2182-2 9.9.17 Page 3 of 3 approved roofing materials directory or ASTM E108/ JL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T235-07, Reporting Date 7/12/07 Project No. T172-08, Reporting Date 4/29/08 DRAWN 8Y. CHECKED BY: B.S. D.S. PLOT: DATE: PANEL FASTENER SPACING = a zs,s 5V—CRIMP SEE DETAIL 1 PER ALLOWABLE PRESSURE TABLE ON THIS SHEET. II II II o PLYWOOD UNDER YA MENT SHALL BE INSTALLED MINIMUM ATTACHMENT: 19/32" THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION 8d x 2.5" LONG RING SHANK NAIL MIN. 2X_ WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED @ 6" O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT INTERMEDIATE LOCATIONS 5V—CRIMP SEE DETAIL 1 —24 0 0 \ U N Z I=O � �Op GUIDELINES Q L� o(n Y I PLYWOOD UNDERLAYMENT SHALL BE INSTALLED Z �w MINIMUM ATTACHMENT: 19/32" THICK (MIN.) ¢ ocJoo AS PER MANUFACTURER'S INSTALLATION M 8d x 2.5" LONG RING SHANK NAIL => MIN. 2X_ WOOD RAFTER/JOIST/ OR #8 x 2" LONG WOOD SCREWS J TRUSS AT MAX. 24" O.C. SPACED @ 6" O.C. IN THE FIELD & po AT PLYWOOD EDGES FASTENER PATTERN AT PANEL ENDStj Q TYPICAL PANEL INSTALLATION X-SECTION ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE ui SPACING (PSF) w a (IN) a o #9-16 OR #10-14 WOODSCREWS— _ _ WITH SELF SEALING WASHER AT 24 84.5 a a MAXIMUM SPACING OF 24" O.C. g 18 131.3 v Y 5V—CRIMP 12 49.6 5�N MIN 26 GA. ° <N GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. UNDERLAYMENT PLYWOOD 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS 19/32" THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM DETAIL 1 REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. oRnwlNc No. Rev 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS RA' REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 21 SHEET N0. L 1OF