Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R40SM7 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Departttient of Business and Professional Regulation - Residential Performance Method Pm)eCNam 1AW)ONADORMIDElC8 9ofda Nam: FLTRENDHOMEB atnwt 1821 DUNN ROAD (aOUni LOT) Pand0 bk4: Br WC18 CbUN7Y C11.sM4Z11x I=FORM. FL. Pun3Number Owner SEGUNDOUA DON11DO Juiedb00e er LUCIECOUNTY DadMLWMiaa FL, Fat Plan CouNy. 8LWd0(Fbdda COmaM7am 2) 1. Nwm.hudima'mt+O9 Nw(Rw Plus) 9. Wa07WN (359:73 agR) budgan Area 2 ahebM1mboroad4M brnA' 8irpi►farrOr. a.Caada Bbdr-bt bns4 ededw Re4.1 341330m 3. Humberafuna%worad4wanjy 1 b.Ftam-Wood,Ad{aard Ra11A trtomm a WA R• p &'NumberalBodwas 4 d. WA R. p S. bnbbaworsttm7 (yes 10.CeRsTres MM 9111L). InaLt on Area B. Cadeaedikarmah0aegwom 28W a RoorDwk(Urwerded) IL NA R-M 20DODm Lh m Cardslaed tbwn bekwgrada (ae) o c. WA R- m 7. Wkdwm(511S sgjL) Deswipin, ArmADMIS _ R m 6 IN a U-Fodor agi, Uy.11 IsamfF b.3rm•. AAtk Rd:JVkAN A�>de 8 Vs 0. W%cftr ago UAA4 112Drm 12.Coofrg rydarra 52UW Efftkn.y SHM 8HGO-MM - Mcewdurit 42o SEFR.•1Sm e LLFador 8p(.u-OM 10483m 0.CaM1unD 188 SFER.1800 SHM &130=033 13. Nea rs spwm Mftft Mwency d. U-Fadar dhw(andabb) 108MM aEkebb SW Had 34D Cop. A0.00 Sim am (am dev0a) b.EladrbBMPHed 17.0 COP:IAD AMaWebl2ed&Msa0mhxQOgft as"B. kmWevem Atoage SHGQ 0285 14.Hdwatere VA" 8. PAWT)gea GM0 e03 baada0a Ara a.Medfb Cax5O9wbM %SbbC*Gtade EdgeiaafaTwn R-0.0 2940.001P 0. ralalraee Epn b. WA R= atoneom N c.MA R. m 15Credk NOW GiasslFloorArra 0.174 Tote] Proposed Modified Loads 101.72 PASS Total Baseline Loads 106.32 hereby caft that the plans and ape III I ons covered by Reviem of ft plans and O4SiL6S%t�O.a tHscalculation are InCompliance vAththe Florida Energy CoAa spedficallons covered by Ub calculation Indcates compliance With the Florida Energy Code g PREPAR�D�1, Before cmatruc8on Is competed Webw7dngwill balropedodfor S w' t DATE_- `—�j'• ti comp]Ianeemith section 583.908 1 hereby mUtythatNo buildng, as designed, Is In compliance Florida Stabiles. c wThtheFloddaEnemy, - WE OWNEMAGENT�I � �/ BUILDING OFFICIAL: DATE DATE: -CompLmwmgWmscefifk:dtonbythealrhandlerurdtmanutaeWmthatUmairhmugerenclowrequalifiesas i LoazUfied f da;" aled In accordancewlth R403.3.21. l -Compliance requires an Air Barrier and Insulation Inspection Checidlet in accordance with R4024.1.1 and this project requires an emrelope b*Age test teportwith envelope leakage no greater than 5.00 ACHSO (R4024.1.2). - ComplteneewOb a proposed duct Waage On requires a Duet Leakage Test Report confirming dud leala p to outdoors, tested in accordance with ANSURESNETACC 380, is not greater than 0.030 on forwhole houses 10=12YPM EuegyOagam USACM (Rev. 1) -FbReo2MTFBC b1h Edfim(20TO Compfard8aftswa Poplars FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MALDONADO RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2940 Lot # Owner Name: SEGUNDO MALDONADO Total Stories: 1 BlocMSubdivision: #of Units: 1 Worst Case: No PlatBoolc Builder Name: FL TREND HOMES Rotate Angle: 0 Street: 1521 DUNN ROAD (SO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1928 20780 2 AHU 2 1012 10522 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 4 156 1560 No 0 1 1 Yes Yes Yes 2 GREAT ROOM 500 6500 No 0 1 Yes Yes Yes 3 KITCHEN 180 1800 Yes 0 1 No Yes Yes 4 DINING 226 2260 No 0 1 Yes Yes Yes 5 NOOK 160 1600 No 0 1 Yes Yes Yes 6 PANTRY 16 110 No 0 1 No Yes Yes 7 KIDS ROOM 169 1690 No 0 1 Yes Yes Yes 8 BATH 4 60 600 No 0 1 Yes Yes Yes 9 WIC 30 300 No 0 1 Yes Yes Yes 10 BATH 3 54 540 No 0 1 Yes Yes Yes 11 WIC 3 32 320 No 0 1 Yes Yes Yes 12 BEDROOM 3 144 1440 No 0 1 1 Yes Yes Yes 13 UTILITY 80 800 No 0 1 Yes Yes Yes 14 HALLWAY 68 680 No 0 1 No Yes Yes 15 HALL 24 240 No 0 1 Yes Yes Yes 16 STORAGE 29 290 No 0 1 Yes Yes Yes 17 MASTER BEDROO 402 4422 No 0 1 1 Yes Yes Yes 18 M W IC 1 70 700 No 0 1 Yes Yes Yes 19 M WIC 2 30 300 No 0 1 No Yes Yes 20 M TOILET 28 280 No 0 1 Yes Yes Yes 21 M BATH 192 1920 No 0 1 Yes Yes Yes 10202012:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 HALL 20 200 No 0 1 No Yes Yes 23 WIC 2 30 300 No 0 1 Yes Yes Yes 24 BATH 2 60 600 No 0 1 Yes Yes Yes 25 BEDROOM 2 180 1800 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulation BEDROOM 4 13 ft 0 156 ft' 1 0 0 2SIabOnGrade Edge Insulation GREAT ROOM 18 ft 0 Soo Ill. -- 1 0 0 3SIab-OnGrade Edge Insulation KITCHEN 1ft 0 180ft. -_ 1 0 0 4SIab-On-Grade Edge Insulation DINING 15ft 0 226 ft' __ 1 0 0 5SIab-0nGrade Edge Insulation NOOK loft 0 160 ft' _- 1 0 0 6SIab-On-Grade Edge Insulation PANTRY 1 ft 0 16 ft' — 1 0 0 7SIab-On-Grade Edge Insulation KIDS ROOM 13 ft 0 169 ft' _- 1 0 0 SSlab-On-Grade Edge Insulation BATH 4 8 ft 0 60 ft' 1 0 0 9SIab-On-Grade Edge Insulation WIC 4 loft 0 30 ft' _- 1 0 0 10SIab-On-Grade Edge Insulation BATH 3 8 ft 0 54 ft' 1 0 0 11SIab-0nGrade Edge Insulation WIC 3 4 It 0 32 ft' — 1 0 0 12SlabOnGrade Edge Insulation BEDROOM 3 12 ft 0 144 ft2 1 0 0 13SIabOnGrade Edge Insulation UTILITY loft 0 80 ft' -_ 1 0 0 14SIab-OnGrade Edge Insulation HALLWAY 1 ft 0 68 ft- — 1 0 0 15SIabOnGrade Edge Insulation HALL 6 ft 0 24 ft' -- 1 0 0 16SIabOnGrade Edge Insulation STORAGE 16 it 0 29 ft' -- 1 0 0 1751abOnGrade Edge Insulation MASTER BEDRO 25 ft 0 402 ft- -- 1 0 0 1831ab-0nGrade Edge Insulation M WIC 1 loft 0 70 ft- — 1 0 0 19SIabOnGrade Edge Insulation M WIC 2 1 ft 0 30 ft- -- 1 0 0 20SIabOnGrade Edge Insulation M TOILET 4 ft 0 28 ft' -- 1 0 0 21SIabOnGrade Edge Insulation M BATH 11 It 0 192 ft- — 1 0 0 22SIabOnGrade Edge Insulation HALL 2 1 ft 0 20 ft' — 1 0 0 23SIab-OnGrade Edge Insulation WIC 2 511 0 30 ft- — 1 0 0 2461ab-On-Grade Edge Insulation BATH 2 9 ft 0 60 ft' -- 1 0 0 1/2/202012:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 253IabOn-Grade Edge Insulation BEDROOM 2 17 ft 0 180 ft' __ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested. Tested Insul. (deg) 1 Hip Metal 3185 ft' 0 ft- Light N 0.1 No 0.9 No 20 22.6 ATTIC / in) Area RBS IRCC V # Type Ventilation Vent Ratio (1 1 Full attic Unvented 0 2940 f' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Fmc Truss Type 1 Under Attic (Unvented) BEDROOM 0 Blown 156 ft' 0.1 Wood 2 Under Attic (Unvented) GREAT ROOM 0 Blown 500 ft' 0.1 Wood 3 Under Attic (Unvented) KITCHEN 0 Blown 180 ft' 0.1 Wood _ 4 Under Attic (Unvented) DINING 0 Blown 226 ft' 0.1 Wood _ 5 Under Attic (Unvented) NOOK 0 Blown 160 ft' 0.1 Wood _ 6 Under Attic (Unvented) PANTRY 0 Blown 16 ft' 0.1 Wood 7 Under Attic (Unvented) KIDS ROOM 0 Blown 169 ft' 0.1 Wood 8 Under Attic (Unvented) BATH 4 0 Blown 60 ft' 0.1 Wood 9 Under Attic (Unvented) WIC 0 Blown 30 ft' 0.1 Wood 10 Under Attic (Unvented) BATH 0 Blown 54 ft2 0.1 Wood _ 11 Under Attic (Unvented) WIC 0 Blown 32 ft' 0.1 Wood 12 Under Attic (Unvented) BEDROOM 3 0 Blown 144 ft' 0.1 Wood _ 13 U nder Attic (Unvented) UTILITY 0 Blown 80 ft' 0.1 Wood _ 14 Under Attic (Unvented) HALLWAY 0 Blown 68 ft' 0.1 Wood 15 Under Attic (Unvented) HALL 0 Blown 24 ft' 0.1 Wood 16 Under Attic (Unvented) STORAGE 0 Blown 29 ft' 0.1 Wood 17 Under Attic (Unvented) MASTER BEDRO 0 Blown 402 ft' 0.1 Wood 18 Under Attic (Unvented) MWIC1 0 Blown 70 ft' 0.1 Wood 19 Under Attic (Unvented) MWIC2 0 Blown 30 ft' 0.1 Wood 20 Under Attic (Unvented) MTOILET 0 Blown 28 ft' 0.1 Wood 21 Under Attic (Unvented) M BATH 0 Blown 192 ft' 0.1 Wood 22 Under Attic (Unvented) HALL2 0 Blown 20 ft' 0.1 Wood 23 Under Attic (Unvented) WIC 0 Blown 30 ft' 0.1 Wood _ 24 Under Attic (Unvented) BATH 2 0 Blown 60 ft' 0.1 Wood 25 Under Attic (Unvented) BEDROOM 0 Blown 180 ft' 0.1 Wood 10202012:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block- Int InsuBEDROOM 4 4.1 12 0 10 0 120.0 W 0 0 0.1 0 _ 2 S Exterior Concrete Block - Int InsuBEDROOM 4 4.1 12 0 10 0 120.0 ft- 0 0 0.1 0 _ 3 W Exterior Concrete Block- Int InsuBEDROOM 4 4.1 7 0 10 0 70.0 k' 0 0 0.1 0 _ 4 E Exterior Concrete Block- Int InsLGREAT ROO 4.1 18 0 13 0 234.0 ft' 0 0 0.1 0 -5 W Exterior Concrete Block - Int InsLGR EAT ROO 4.1 17 0 13 0 221.0 ft- 0 0 0.1 0 6 N Exterior Concrete Block -Int Insul DINING 4.1 13 0 10 0 130.0 ft- 0 0 0.1 0 _ 7 E Exterior Concrete Block -Int Insul DINING 4.1 14 0 10 0 140.0 ft' 0 0 0.1 0 _ 8 S Garage Frame -Woad DINING 11 3 0 10 0 30.0 ft' 0 0.1 0.1 0 _ 9 N Exterior Concrete Block- Int Insul NOOK 4.1 2 0 10 0 20.0 W 0 0 0.1 0 _ 10 W Exterior Concrete Block- Int Insul NOOK 4.1 8 0 10 0 80.0 it, 0 0 0.1 0 11 NW Exterior Concrete Block -Int Insul NOOK 4.1 7 4 10 0 73.3 ft- 0 0 0.1 0 _ 12 S Exterior Concrete Block- Int InsuKIDS ROOM 4.1 13 0 10 0 130.0 ft' 0 0 0.1 0 _ 13 E Exterior Concrete Block- Int Insul BATH 4 4.1 1 0 10 0 10.0 ft' 0 0 0.1 0 _ 14 S Exterior Concrete Block- Int Insul BATH 4 4.1 6 0 10 0 60.0 It. 0 0 0.1 0 _ 15 W Exterior Concrete Block- Int Insul BATH 4 4.1 1 0 10 0 10.0 fN 0 0 0.1 0 _ 16 N Exterior Concrete Block - Int Insul WIC 4 4.1 5 0 10 0 50.0 ft' 0 0 0.1 0 _ 17 S Exterior Concrete Block- Int Insul WIC 4 4.1 5 0 10 0 50.0 ft= 0 0 0.1 0 _ 18 E Exterior Concrete Block- Int Insul BATH 3 4.1 1 0 10 0 10.0 ft' 0 0 0.1 0 _ 19 S Exterior Concrete Block- Int Insul BATH 3 4.1 6 0 10 0 60.0 ft' 0 0 0.1 0 20 W Exterior Concrete Block - Int Insul BATH 3 4.1 1 0 10 0 10.0 ft= 0 0 0.1 0 21 S Exterior Concrete Block - Int Insul WIC 3 4.1 4 0 10 0 40.0 W 0 0 0.1 0 22 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 10 0 120.0 ft' 0 0 0.1 0 23 S Exterior Concrete Block- Int Insul UTILITY 4.1 10 0 10 0 100.0 ft' 0 0 0.1 0 24 E Garage Frame -Wood UTILITY 11 8 0 10 0 80.0W 0 0.1 0.1 0 25 N Garage Frame -Wood UTILITY 11 3 0 10 0 30.0 ft' 0 0.1 0.1 0 26 E Garage Frame - Wood HALLWAY 11 4 0 10 0 40.0W 0 0.1 0.1 0 27 N Exterior Concrete Block- Int Insul HALL 4.1 6 0 10 0 60.0 it= 0 0 0.1 0 28 N Exterior Concrete Block- Int Insul STORAGE 4.1 5 0 10 0 50.0 w 0 0 0.1 0 _ 29 S Exterior Concrete Block- Int Insul STORAGE 4.1 5 0 10 0 50.0 fI2 0 0 0.1 0 _ 30 W Exterior Concrete Block - Int Insul STORAGE 4.1 6 0 10 0 60.0 ft. 0 0 0.1 0 31 N Exterior Concrete Block- Int InsuMASTER BE 4.1 18 0 11 0 198.0 ft' 0 0 0.1 0 32 S Exterior Concrete Block- Int InsuMASTER BE 4.1 18 0 11 0 198.0 ft' 0 0 0.1 0 33 W Exterior Concrete Block- Int InsuMASTER BE 4.1 19 0 11 0 209.0 ft' 0 0 0.1 0 34 N Exterior Concrete Block- Int Insul M WIC 1 4.1 10 0 10 0 100.0 ft' 0 0 0.1 0 35 N Ederior Concrete Block- Int Insul M TOILET 4.1 4 0 10 0 40.0 fF 0 0 0.1 0 36 N Exterior Concrete Block- Int Insul M BATH 4.1 11 0 10 0 110.0 ft' 0 0 0.1 0 _ 37 N Exterior Concrete Block- Int Insul WIC 2 4.1 5 0 10 0 50.0 ft` 0 0 0.1 0 38 N Exterior Concrete Block- Int Insul BATH 2 4.1 10 0 10 0 100.0 ft' 0 0 0.1 0 39 E Exterior Concrete Block- Int Insul BATH 2 4.1 6 0 10 0 60.0 ft' 0 0 0.1 0 40 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 12 0 10 0 120.0 ft' 0 0 0.1 0 41 S Exterior Concrete Block- Int InsuBEDROOM 2 4.1 15 0 10 0 150.0 ft 0 0 0.1 0 10202012:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown Is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 N 1 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft- 6 ft 6In 3 ft 5 in None None _ 2 E 4 Metal Low-E Single Yes 1.11 0.27 N 12.0 ft- 6 ft 6In 2 ft 0 in Drapes/blinds Exterior 5 _ 3 E 4 Metal Low-E Single Yes 0.99 0.33 N 32.0 ft- 1 ft 6 in 4 ft 0 in Drapes/blinds Exterior 5 4 E 4 Metal Low-E Single Yes 1.04 0.29 N 48.0 ft- 6 ft 6 in 5 ft 0 in Drapes/blinds Exterior 5 5 W 5 Metal Low-E Single Yes 1.11 0.27 N 96.0 ft- 18 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5 6 E 7 Metal Low-E Single Yes 1.04 0.26 N 20.0 ft2 1 ft 6 in 2 ft 5 in Drapes/blinds Exterior 5 _ 7 E 7 Metal Low-E Single Yes 1.04 0.26 N 15.0 ft- 1 ft 6 in 2 ft 5 in Drapes/blinds Exterior 5 8 W 10 Metal Low-E Single Yes 0.99 0.33 N 12.0 ft2 10 It 6 in 1 ft 5In Drapes/blinds Exterior 5 9 W 10 Metal Low-E Single Yes 0.99 0.33 N 21.3 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5 10 NW 11 Metal Low-E Single Yes 0.99 0.33 N 22.O ft- 10ft6in 1ft5 in Drapes/blinds Exteriors 11 NW 11 Metal Low-E Single Yes 0.99 0.33 N 11.5 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5 12 S 14 Metal Low-E Single Yes 1.04 0.29 N 6.0 ft2 1 ft 6 in 0 ft O in None None 13 S 19 Metal Low-E Single Yes 1.04 0.29 N 6.0 ft2 1 ft 6 in Oft 0 in None None 14 S 22 Metal Low-E Single Yes 1.04 0.26 N 15.0 ft2 1 ft 6 in 0 ft 0 in None None _ 15 S 23 Metal Low-E Single Yes 1.04 0.26 N 15.0 ft2 1 ft 6 in 0 ft 0 in None None _ 16 N 27 Metal Low-E Single Yes 1.04 0.29 N 20.0 ft- 1 ft 6 in 3 ft 5 in None None 17 W 30 Metal Low-E Single Yes 1.04 0.29 N 16.7 ft2 1 ft 6In 3 ft 5In None None 18 N 31 Metal Low-E Single Yes 1.04 0.29 N 16.0 ft2 1 ft 6 in O ft O in None None 19 W 33 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft2 1 ft 61n 8 ft 5In None None _ 20 N 36 Metal Low-E Single Yes 0.99 0.33 N 6.0 1`12 1 ft 6In 0 ft O In None None 21 N 38 Metal Low-E Single Yes 1.04 0.26 N 6.0 ft2 1 ft 6 in O ft O in None None 22 E 40 Metal Low-E Single Yes 1.04 0.26 N 20.0 ft2 1 ft 6 in 2 ft 5 in None None 23 E 40 Metal Low-E Single Yes 1.04 0.26 N 15.0 ft2 1 ft 6 in 2 ft 5 in None None GARAGE # FlcorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 966 112 966 ft2 18 ft 10 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000338 2608.5 143.2 269.31 .1314 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 12/2020 12:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 18.8 kBtu/hr 564 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply— -- Return-- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft' Attic 13 ft- Prop. Leak Free Attic — cfm 57.8 cfm 0.03 0.50 1 1 2 Attic 6 175 ft' Attic 18 ft' Prop. Leak Free Attic — cfm 30.4 cfm 0.03 0.50 2 2 TEMPERATURES Programable(Coolingr)(Thermostat: Ceiling Fans: Jan:X'�N (Febr)(,)Dec War AprX]� 4Mar t[ Ju 4 4 f [(X�� [(X�� Venting j ] Jan [ ]Feb Apr [ May j ] Jun l Jul [X� Aug [ Sep Oct [X] No [ ] Dees Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8lbs/sq.ft. Oft' Oft 0.3 BEDROOM Defauit(S lbs/sq.ft. ft' ft 0.3 GREAT ROOM Defauit(B lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 DINING Defauft(B lbs/sq.ft. fI ft 0.3 NOOK Defauft(8lbs/sq.ft. ft- It 0.3 PANTRY Defauft(8lbs/sq.ft. ft' ft 0.3 KIDS ROOM Default(S lbs/sq.ft. fF ft 0.3 BATH 4 Default(8 lbs/sq.ft. fP ft 0.3 WIC Defau@(8lbs/sq.ft. ft' ft 0.3 BATH 3 10202012:55 PM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 lbs/sq.ft. ft2 ft 0.3 WIG Defauft(81bs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 It 0.3 UTILITY Defauft(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Defauft(8 lbs/sq.ft. fP ft 0.3 HALL Defauft(8 lbs/sq.ft. ft2 ft 0.3 STORAGE Defauft(8lbs/sq.ft. fP It 0.3 MASTER BEDROO Default(8lbs/sq.ft. iP ft 0.3 M WIC 1 Default(8 lbs/sq.ft. ft2 ft 0.3 M WIC 2 Defauft(8 lbs/sq.ft. ft2 ft 0.3 M TOILET Defauh(8 lbs/sq.ft. ft2 ft 0.3 M BATH Defauft(8 lbs/sq.ft. ft2 ft 0.3 HALL 2 Defauft(8lbs/sq.ft. ft- ft 0.3 WIC2 Defauft(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 102020 12:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 %k- 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MALDONADO RESIDENCE Builder Name: FLTREND HOMES Street: 1521 DUNN ROAD (SOUTH LOT) Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner. SEGUNDO MALDONADO Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be Installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints In the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit stall be aligned with the The insulation in any dropped ceiling/soffit Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per Inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottory to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures Installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wirin Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of CC-400. 10202012:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 60.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2940 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.055 b) Solar Heat Gain Coefficient (SHGC) 7b. 0,285 14. Heating system: Capacity 51.0 c) Area 7c. 511.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 1521 DUNN ROAD (SOUTH LOT) City/FL Zip: FORT PIERCE. FL 102020 12:56:08 PM EnergyGauge® USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 . + wrightsoft° Project Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUCKCALCS@AOL.COM Project• • For. MALDONADO RESIDENCE, FLTREND HOMES 1521 DUNN ROAD (SOUTH LOT), FORT PIERCE, FL N otes: Job: Date: JAN. 2, 2020 By: Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32698 Btuh Structure 23569 Btuh Ducts 6649 Btuh Ducts 7542 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 39347 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 29555 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4123 Btuh Ducts 2644 Btuh Central vent (0 cfm) 0 Stuh Heatingg Coolingg (none) Area (ft2) 1928 1928 Equipment latent load 6767 Btuh Volume (ft3) 20780 20780 Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 36322 Btuh Equiv. AVF (cfm) 102 51 Req, total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40431-1 AHRI ref Coil TEM6AOC6OH51++TDR+UF/HRZ AHRI ref 8858419 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 11.4 kW Sensible cooling 29400 Btuh Heating output 38754 Btuh Latent cooling 12600 Btuh Temperature nse 25 OF Total cooling 42000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �. -Fla- wrightsoft• 2020-Jan-0212:64:10 �- Rlght-Suite® Unhrmal2019 19.0.09 RSU09101 Pogo 1 �'L'P` ... cumnetslWrightsoftHVACIMALDONADO RESIDENCE.rup Calc = MJS Front Door faces: E wrightsoft° Project Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 7724665799 Fax 772466-6796 Email: QUCKCALCS@AOL.COM For: MALDONADO RESIDENCE, FL TREND HOMES 1521 DUNN ROAD (SOUTH LOT), FORT PIERCE, FL Notes: Job: Date: JAN. 2, 2020 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16410 Btuh Structure 9877 Btuh Ducts 2344 Btuh Ducts 3511 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humiidlfcation 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18754 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12719 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2864 Btuh Ducts 928 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft') 1012 1012 Equipment latent load 3792 Btuh Volume (W) 10522 10522 Airchangeslhour 0.37 0.19 Equipment Total Load (Sen+Lat) 16511 Btuh Equiv. AVF (cfm) 65 33 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018J1 AHRI ref Coil TEM4AOB18S21++TDR AHRI ref 8676071 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 5.3 kW Sensible cooling 13160 Btuh Heating output 18195 Btuh Latent cooling 5640 Btuh Temperature rise 26 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigt of!' 2020Jan-0212:54:10 RlghtSulteO UnWmal 2019 19.0.08 RS1A8101 Page 2 ...cu=etslWrightsoRHVAMMALDON4DORESIDENCE.rup Calc=MJB Fmnt Dooncces: E (IAA W N N +' m NAWN+ 88M a��' ga � d. S� N m ��N �'� 3ro� NN+NN NNN+NN+NNNNNNN+NNNNN+ mmm m 3 RICO a_mmmm_m_m_ m_mmm_m 3m' o -�.� _ �. a a RIX 21 219'a, 3I.��19 �g m am 9. am �_ �_ �_ g g �_ :_ � g$9. q$�_ g$� #Qs. q#a 9$a_ 9$�_ HUM �m AA 0�6 fm A�bm��� ����m $0CCC 9 yym �1 5�g O}coo ++0yO3pp Op+pp+pO j j+p+pQ+QQQ+p+pO j+Q+QQp+$O�ggO oSSS t3 �m ym �m >!offi YS EYoo Sz575 �SStio'O St3'o'oti SE5 ��'F ��FF FFFFmNHmmmmmmmm>?> »> � g(� � • NN W� NN pro.fvr� WWWNN WW +VVA+, OVV atp iO A-�+,+!D !OO OA++pO OA aiSirrB�$8r^I.r�1.8NN8BSSNN888S$8888 ��pp .Y �b O+L>r2p trJ3 rr��NNUr�v1JU Is rJ NWN ION+NNW mO]OI O)O ONNNO CON _ y3' pO BV Nivm mho OVJmSS die+m +m'm�i�88m++$$8m � O D O _ m1p r�+1 {p AqAq yy Nd NN(Y OfV OWN+NOiS� NN000EOOOOO � 0 O O w a f� 44aa rye �1 +W� O 00 O O 00 Ot1SN O� 0 0 00 00 O J O 00 00 O v W v V L W C ,A., yyy1{ ZSV p� ttOO tamWOOO ONN [p[pnn jj��JJ11{{ ttII��LyLyff(�(�pppp ��11yy OVbOW+O+IOAZSINWVO OYfS ij lApO OO m+ po C� v 6 �O �y(�j' �$+ qj' �py� �$�!!p� �([qJ $$rryyl1 flj fp+fpII��+rrpp (y(yililyy pW� O� N�DOOO OW + M OW�Kp1W OFEA �{Yf KjNO+WO+OOJOOO 2 O 98 O O O O O O 00 000 O O O O O O O O O O O O O 00 j^ O O � m + YN a W 0 o +9000 OOO0000c8oOooOoomoO000$ �Fn x o0 ^O �h � A N O� A OWN OO 7mV00000OOOOO900000OOOObOOO Syr � V � AS 01 LfJOO 00 ON O�OOOOO OOO�OO41O OOOOOOOO�O OOf~l� L� Z L m O v m. r wrightsoft• Right-M Worksheet AHU1 QUICK CALCS, INC. 317ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCSQAOL.COM Job: Date: JAN. 2, 2020 By: 1 Room name GREAT ROOM KITCHEN 2 Egxised wall 35.0 0 0 R 3 Room height 13.0 ft heat/conl 10.0 R heatfcod 4 Room dimensions 26.0 x 20.0 It 1.0 x 180.0 ft 5 Room area 5W.0 fN 180.0 ft' Ty Construction 1-1-value Or HTM Area 010 Load Area (00 Load number (Btuhlft;°F) (EILM11) or perimeter (it) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Grass WP/S Heat Cool 6 13A-4oas 2 glazing, air Iowa 2 glazing, air lows 0.143 0.990 1.040 n n n 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --G 1 2 glazing, air lowe 2 glazing, cir hire 1,040 1.110 n n 0.00 31.08 0.00 22.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, air lowe 13A-4aos 1.110 0.143 , n a 31.08 4.00 22.31 2.19 0 234 0 142 0 569 0 311 0 0 0 0 0 0 0 0 W 2 glazing, air lowe 1.040 a 0.00 0.00 0 0. 0 0 0 0 0 0 2 glazing, air lame 2 glazing, cir Iox a 1.040 1.040 a a 0.00 29.12 0.00 26.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, air lowe 2 glazing, air lows 2 glazing, air lorme 1.040 1.110 1.110 a a a 29.12 31.08 31.08 26.73 28.16 28.16 0 12 32 0 0 0 0 373 go 0 338 901 0 0 0 0 0 0 0 0 0 0 0 0 2 plazinp, clr lows 1.110 a 31.08 28.16 48 0 1492 1352 0 0 0 0 W, 13I4ocs 0.143 s 4.00 2.19 '0 0 0 0 b 0 0 0 tl----GG 2 glazing, air bane 2 glazing, air lowe 13A-4ocs 1.040 1.040 0.143 s s w 29.12 29.12 4.00 21.05 21.68 2.19 0 0 221 0 0 125 0 0 501 0 0 273 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir laws 2 glazing, air lowe 2 glazing, cir lowe 0.990 0.990 1.040 w w w 27.72 27.72 0.00 29.47 29.47 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, air lows 1.110 w 31.08 42.69 0 0 0 0 0 0 0 0 2 glazing, air Iowe 1.110 w 31.08 28.16 96 0 2984 27D3 0 0 0 0 1344ocs 0.143 my 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir lowe 2 glazing, air lave 0.990 0.990 my M 27.72 '27.72 24.27 24.27 0 0 0 0 0 0 0 0 0 0 '0 0 0 0 0 0 C 16X190md 0.408 - 1.59 1.37 500 500 793 664 180 180 285 246 'F 22P Kph 1.358 - 38.02 0.00. '500 35 1331 0 180 _ 0 0 0 6 c)AED excursion 63 -96 Ewelope loss/gain 9036 6626 285 150 12 a) Infiltration 685 183 0 0 b) Room ventilation 0 0 0 0 13 Internal gams: Occupants 230 0 0 0 0 Appliarx:eslolher 0 2500 Subtotal (fines 6 to 13) 9721 6808 285 2650 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 9721 68138 285 2650 15 Duct loads 20% I 320/o 1977 2179 201/6 32% 58 848 Trial =in load 1 11697 1 8987 343 3493 Air required (don) 416 404 12 157 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -0W wri tn!!Ft e- 2020.1an-0212:54:10 A ""^ Right -guile@ Universal 2019 19.0.08 RSU08101 Page 2 ... cumnets\Wdghtsoft FNAC\MALDONADORESIDENCE.rup Celc=MJ8 Fmnt Doorfaces: E wrightsoft• Right-J®Worksheet Job: AHU 1 Date: JAN. 2, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6798 Email: OUICKCALCSIAOL,COM 1 Room reme DINPIG NOOK 2 Brimed wall 27.0 ft 17.3 It 3 Room height 10.0 0 heatf=l 10.0 0 heat/cod 4 Roan dimensions 1.0 x 226.0 it 1.0 x 160.0 a 5 Room area 226.0 fF 160.0 iR Ty Construction U-value Or FI7M Area (0� Load Area (fl') Load number (Btuh/t?°F) (BtuhRt� or perimeter (ft) (Btuh) or pedmeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13PA= 0.143 a 4.00 2.19 130 130 521 284 20 20 80 44 2 glazing, clr lave 0990 n. 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr lave 1.040 n 0.00 0.00 0 a 0 0 0 0 0 0 2 glazing, cir Iwre 1.040 n 0.00 0.00 0 a 0 0 0 0 0 0 11 2 glazing, dr lave 1.110 n 31.08 22.31 0 0 0 0 0 0 0 0 2 glazing, clr lave 1.110 n 31.08 22.31 0 a 0 0 0 0 0 0 13AAccs 0.143 a 4.00 2.19 140 105 420 230 0 0 0 0 2 glazing, cir lave 1.040 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lcv -e 1.040 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr Ic*e 1.040 a 29.12 26.73 20 0 582 635 0 0 0 0 2 glazing, dr lave 1.040 a 29.12 28.73 15 0 437 401 0 0 0 0 2 glazing, dr Iw 1.110 a 31.08 28.16 0 0 0 0 0 0 0 0 2 glazing, cir lave 1.110 a 31.08 28.16 0 0 0 0 0 0 0 0 2 glazim. cir lave 1.110 a 31.08 28.16 0 0 0 0 0 0 0 0 W, 13A-0ccs 0.143 s 4.00 2.19 0 0 0 0 a 0 0 0 2 glazing, dr Iave 1.040 s 29.12 21.05 0 0 0 0 a 0 0 0 t�-CC 2 glazirg, cir lave 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 1 13A-0as 0.143 w 2.47 0 0 0 0 80 47 2 glazing, dr lave 0.990 w 27.72 7.72 29.47 0 0 0 0 12 0 333 354 2 glazing, dr lave w 27.72 20.00 0 0 a 0 21 0 593 591 629 620 2 glazing, dr 1v++e 1.040 to4o w noo o.ao o a o 0 0 0 0 0 2 glazing, dr lvxe 1.110 w 31.08 42.59 0 0 a 0 0 0 0 0 2 glazing, dr Ivve 1.110 w 31.08 28.16 0 0 0 0 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 73 40 15B 86 t134-4= 1Ga 2 glazing, or b*e 0.990 my 27.72 2427 0 0 0 0 22 a 610 534 2 glazing, dr lowe 0.990 mn 27.72 2427 0 0 0 0 12 0 319 279 C 16X191Dnd 0.408 - 1.59 1.37 226 226 358 309 160 160 254 219 F 22Adph 1.358 - 38.02 0.00 226 27 1027 0 160 17 656 0 6 c)AED esursion 81 795 Envelope loss/gain 3345 1840 3187 3041 12 a) Infiltration 405 109 260 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appfianoeslofher 0 0 Subtotal (lines 6 to 13) 13752 1949 3448 3111 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 43 35 0 0 14 Subtotal 3794 1984 3448 3111 15 Duct loads 20% 329/6 772 635 20% 32% 701 995 Total room land 4%6 2619 4149 4106 Air required (rim) 162 118 148 185 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -FIF wr19F+tsoR- 2020Jan-0212:54:10 IcA Right-BuheO Un*wmat 2019 19.0.D8 RSLf18101 Page 3 ...cumnetslWnghtsoft F1VAC\MALDONADO RESIDENCErup Celc = M.18 Front Door faces: E + wrightsoft- Right-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LAM:, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM Job: Date: JAN. 2, 2020 By: 1 Room narne PANTRY IODS ROOM 2 3 Exposed wall Room height 0 ft 10.0 ft heat(ccol 13.0 R 10.0 ft heat/cod 4 Room dimensions 4.0 x 4.0 ft 13.0 x 13.0 0 5 Room area 16.0 fN 169.0 ft' Ty Constriction LWalue Or FRA1 Prey (02) Lond Area (82) Load number (BtutAW-F) (6lut✓ft� or perimeter (ft) (BWh) or perimeter (ft) (Muh) Heal Cool Gross WP/S Heat Cool Gross NP/S Heal 0001 6 13A4= 2 glazing, dr Icwe 2 glazing, dr to - 0.143 0.990 1.040 n n n 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G i 2 glazing, dr bxe 2 glazing, dr lox¢ 1.040 1.110 n n 0.00 31.08 0.00 22.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr IOxe 13PAccs 2 glazing, dr Ioxe 1.110 0.143 1.040 n a a 31.08 4.00 0.00 22.31 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lox¢ 2 glazing, cir lave 1.040 1.040 a a ODO 29.12 0.00 26.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr lory a 2 glazing, dr lc xe 2 glazing, dr lave 1.040 1.110 1.110 a a a 29.12 31.08 31.08 26.73 28.16 28.16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 20lazin0, dr lave 13A4ocs 1.110 0.143 e s _ 31.08 4.00 28.16 2.19 0 0 0 0 0 0 0 0 0 130 0 130 0 521 0 284 W, IL-Ct', 2 glazing, dr low-e 2 glazing, cir lore 13P.4ccs 1.040 1.040 0.990 6 a w 29,12 29.12 21,05 21.68 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr kwa 2 glazing, ch lows a 2 gug, cU I0x-a 0.990 0.990 1.040 w w w 27.72 7.72 2. 00.0000 29.47 9.47 29.47 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, ch lova-e 2 glazing, dr Icwe 1.110 1.110 w w 31.08 31.08 4259 28.16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4ocs 2 glazing, dr lov 2 glazing, dr Ioxe 0.143 0.990 0.990 av av ox 4.00 27.72 27.72 2.19 24.27 2427 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16XI90M 0.408 - 1.59 1.37 16 16 25 22 169 169 269 231 F me tph 1.358 - 38.02 0.00 16 0 _ 0 0 169 13 494 0 6 c)A.ED excursion -1 Envelope bWgain 25 21 1283 461 12 a) Irdihralion 0 0 195 52 b) Ronmvedilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Pppiarcesrdher 0 1000 Subtotal (lines 6 to 13) 25 21 1478 1513 Less edennal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 5 325 163 14 Subtotal 31 26 18D4 1676 15 Dud leads 20% 329/6 6 8 209/6 32% 367 536 Toroom Iced I 37 1 34 2170 2212 Air required (rim) 1 2 77 100 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. ►- wrLsn!! aan- 2020Jan-Jan12:54:10 �Right-Sufte® Universal 2019 19.0.08 RSLD8101 Page 4 ...cumetslWrightso8 WACIMALDONADO RESIDENCErup Cato - MJ8 Front Door faces: E wrightsofr Right-M Worksheet Job: AHU 1 Date: JAN. 2, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772d66-6796 Email: OIACKCALCS@ACL.COM 1 Room name BATH 4 WIC 4 2 Exposed wall 8.0 ft 10.0 It 3 Room height 10.0 ft hnat/cool 10.0 ft heat/ood 4 5 Room dimensions Room area 6.0 x 10.0 It 60.0 fP 5.0 x 6.0 ft 30.0 fP Ty Construction number U-value (Btuhtfti°Fj Or HTM (Ettmtl) Area or perimeter Qt) (Btuh) or perimeter at) (EVuh) Heat Oool Gross WPlS Heat Cool Gross WP/S Heat Cool 6 G. 13AAocs 2 glazing, dr lave 2 glazing, dr love 0.143 0.990 1.040 In In n 4.00 0.00 1100 2.19 0.00 0.00 0 0 a 0 0 0 0 0 0 0 0 •0 50 0 0 50 0 0 200 0 0 109 0 0 G 2 glazing. cir lone 1.040 In 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing, dr lave 1.110 In 31.08 22.31 0 0 0 0 0 0 0 0 2 glazing, cir lave 13AAa 1.110 0.143 In a 31.08 4.00 22.31 2.19 0 10 0 10 0 40 0 22 0 0 0 0 0 0 0 0 2 glazing, dr lave 1.040 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir lc a 2 glazing, cir Iowa 1.040 1.040 a a 0.00 29.12 0.00 26.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr lowe 2 glazing, clr lave 2 glazing, cir lave 1.040 1.110 1.110 a a a 29.12 31.08 31.08 25.73 28.16 28.16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 gbizing, cir lave 1.110 a 31.08 28.16 0 0 0 0 0 0 0 0 W 1 13A-4acs 2 glazing, dr Iowa 2 glazing, dr lave 1344acs 0.143 1.040 1.040 0.143 s s s w 4.00 29.12 29.12 4.72 2.19 21.05 21.68 60 0 fi 10 54 0 6 -10 216 0 175 40 118 0 130 22 50 0 0 0 50 0 0 0 200 0 0 0 109 0 0 0 2 glazing, dr lave 02M w 27.72 9.47 29.47 0 0 0 0 0 0 0 0 2 glazing, cir love 2 glazing, dr Iowa 1.040 1.040 w w 27.72 0.00 20.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 gaming, cir love 1.110 w 31.08 42.59 0 0 0 0 0 0 0 0 2 glazing, cir lave 1.110 w 31.08 28.16 0 0 0 0 0 0 0 0 1@/ 4L-GC 13A4ocs 2glazing, dr lave 2 glazing, dr lave 0.143 0.990 0.990 my w my 4A0 27.72 27.72 2.19 24.27 2427 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0nd 0.408 - 1.59 1.37 60 60 95 82 30 30 48 41 F 22htph 1.358 - 38.02 0.00 W 8 304 0 30 10 380 0 6 c)AED excursion -14 -11 Envelope lose/gain 1870 360 1828 249 12 a) Infiltration 120 32 151 40 b) Rminventilatim 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 0 0 Applancesrdher 0 0 Subtotal (fines 6 to 13) 991 392 979 290 Less edemi load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 489 244 19M 1337 14 Subtotal 1479 636 29M 1627 15 Dud loads 2W 1 327. 301 204 209% 32% W4 521 Tdal mom load 1779 840 3572 2147 Air required (dm) 63 38 127 97 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Pw wr;r96+�+0, ri- 2020-Jan-02 12:54:10 Ask RlghtSufte® Universal 2019 19.0.08 RSL08101 Page 5 ...curnnetslWrightsoft HVAC1MALDONADO RESIDENCE. rup Calc=MJ8 Front Doorfaces: E wrightsofC RighWO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUCKCALCWOL.COM Job: Date: JAN. 2, 2020 By: 1 Room name 13ATH 3 WIC 3 2 Eared wall 8.0 it 4.0 it 3 Rccm hei9M 10.0 It heal/cool 10.0 it heaticod 4 Room dimensions 6.0 x 9.0 it 4.0 x 30 it 5 Room area 54.0 ft' 32.0 W Ty Construction UAalue Or Frrm Area (ft2) Load Area (ft� Load number (Btuh1flk°F) (BIdJftO or perimeter at) (Btuh) or perimeter (it) (Bluh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 13A4ocs 2 glazing, dr lows 2 glazing, dr lows 0.143 0.990 1.040 n n n 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G I 2 glazing, cir lobe 2 glazing, cIr Iwo-e 1.040 1.110 n n 0.00 31.08 0.00 22.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, or lowe 13AAccs 2 glazing, dr lone 1.110 0.143 1.040 h a a 31.08 4.00 0.00 22.31 2.19 0.00 0 10 0 0 10 0 0 40 0 0 22 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr Iave 2 glazing, dr Io 1.040 1.040 a a 0.00 29.12 0.00 25.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr lave 2 glazing, cIr Iowe 2 glazing, dr Iave 1.040 1.110 1.110 a a a 29.12 31.08 31.08 26.73 28.16 28.16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazim, d_r Iaµe 2 glazing, cir lane 2 glazing, clr Iw+e 13A4acs 2 glazing, cir lave 2 glazing, dr lox 2 glazing, cIr Iowa 1.110 0.143 1.040 1.040 0.143 0.9m 0.990 1.040 a s s s w w w w 31.08 4.00 29.12 29.12 4.00 27.72 27.72 0.00 23.16 2.19 21.05 21.68 2.19 29.47 29.47 0.00 0 60 0 6 10 0 0 0 0 54 0 6 10 0 0 0 0 216 0 175 40 0 0 0 0 118 0 130 22 0 0 0 (1 40 0 0 0 0 0 0 0 40 0 0 0 0 0 0 0 160 0 0 0 0 0 0 0 88 0 0 0 0 0 0 ILI13A4ocs 2 glazing, dr laws 2 glazing, dr lmro 1.110 1.110 w w 31.08 31.08 42M 28.16 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 1qJ 13P,4= 2 glazing, dr brre 2 glazing, or fox 1SX19-0nd 0.143 0.990 0.990 0.403 mx nw mo - 4.00 27.72 27.72 1.59 2.19 24.27 24.27 1.37 0 0 0 54 0 0 0 54 0 0 0 86 0 0 0 74 0 0 0 32 0 0 0 32 0 0 0 51 0 0 0 44 II---�(a' C F ZwPh 1.358 - 38,02 0.00 54 8 3134, 0 32 4 152 0 6 c)AEDex ursion -14 -5 Envelope loss/gain 861 362 1363 126 12 a) Infiltration 120 32 60 16 b) Roomventitatim 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 1 0 Subtotal (lines 6 to 13) 981 354 423 142 Lose mdemal load 0 0 0 0 Less transfer 0 0 0 0 14 Redstrihution Subtotal 17 998 14 398 11 435 9 152 15 Duct loads 20% 32% 203 127 20% 32% 88 49 Trial room load 1201 526 Sm 20D Air required (dm) 43 24 19 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4}F =Lwtjt -tft- 2020-Jan-0212:54:10 .fit\ "'"' Right -Suite® Universal 2019 19.0.08 RSU08101 Page 6 ...cuncetslWrightsoft FNAC\MALDONADO RESIDENCErup Calc = MJ8 Front Door faces: E • wrightsoft• Right-J®Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LAME, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772-466-6796 Emit QUCKCALCS@AOL.COM Job: Date: JAN. 2, 2020 By: 1 Room narlle BEDROOM 3 UTILITY 2 Exposed wall 12.0 0 10.0 0 3 Room Might 10.0 ft heagcuol 10.0 it heaVmol 4 Room dimensions 12.0 x 12.0 ft 10.0 x 8.0 it 5 Room area 144.0 It' 80.0 fF TY Conshrctirm number U-value (Stuh/ft%*F) Or FiTNI Mee (Ii or perimeter (ft) Load (Stub) Area (ft-) or perimeter Qt) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 . 13AAous 2 glazing, clr lave 2 glazing, cir b" 0.143 0.990 1.040 n n n 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 Ill 2 glazing, cir lc�e 2 glazing, olr toes 1.040 1.110 n n 0.00 31.08 0.00 22.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, dr lave 13AA= 2 glazing, dr lave 1.110 0.143 1.040 n a a 31.08 4.00 0.00 22.31 2.19 0.00 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 2 glazing, dr to a 2 glazing, cb low-e 1.040 1.040 a a 0.00 29.12 0.00 26.73 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr to a 2 glazing, cb lone 2 glazing, ch lave 1.040 1.110 1.110 a a a 29.12 31.08 31.08 26.73 28.16 28.16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 plazim. dr lave 13A-4acs 1.110 0.143 a s 31.08 4.00 28.16 2.19 _ 0 120 0 105 0 420 0 230 0 100 0 85 0 340 a 186 EI--u 2 2 glazing, dr owe 2 glazing, cir to z 13A4= 1.040 1.040 0.143 s s w 29.12 29.12 4.00 21.05 21.68 2.19 15 0 0 15 0 0 437 0 0 316 0 0 15 0 0 15 0 0 437 0 0 316 0 0 2 glazing, clr to a 2 glazing, dr lows 2 glazing, dr Lave 0.990 DAM 1.040 w w w 27.72 27.72 0.00 29.47 29.47 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lvwe 2 glazing, cb lave 1.110 1.110 w w 31.08 31.08 42.59 28.16 0 0 1 0 0 0 0 a 0 0 0 0 0 0 0 0 0 lQ/ l�-CG 1344ocs 2glazing, dr for 2 glazing, dr bwe 0.143 0.990 o990 mx w27.72 rrx 4.00 27.72 2.19 24.27 2427 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X1940rd 0.408 - 1.59 1.37 144 144 228 197 80 80 127 109 F 22A-tph 1.358 - 38,02 0.00 144 12 456 0 80 10 380 0 61 c)AEDexcursion -03 '^0 Envelope loss/gain 1542 680 1294 581 12 a) Infiltration 181 48 151 40 b) Room ventilation 0 0 0 0 13 hdemal gains: Occupants Q 230 0 0 0 0 Appliances/other 1000 200 Subtotal (lines 6 to 13) 1722 1728 1435 822 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 RedmInbuton 11 9 20 17 14 Subtotal 1734 1738 1455 839 15 Duct loads 20°/n 32% 353 556 209/6 325/6 296 268 Trial room load 2086 2294 17W 1106 Air required (dm) 74 103 62 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. rt`}F wrlgl�bo_f!- 2020Jan-0212:54:10 AWK" Right -Suite® Universal 2019 19.0.08 RSU08101 Page 7 ... cunmets%Wdghtsod HVAC%MALDONADORESIDENCE.mp CaIc=MJS Front Doorfaces: E o m NA W N N �' OI NAWN+ �oo�����������+�����' 'R3b g $$ aaaaa aQ S.QR.aaaa R-aaaa .g 0 i�gg& 0 000 pCSZ. 'J o� y N N WW NN NN W WWN N W W VAN10a+++tp 1pO0A��000A Ip of q sSC7srd8a9H�284N8a8&NN888 SHHH$ O�LNN yy NN 11JJ AN�N OU�r1 N�p�J �W p01NOONNN000N n kS _ y p��p SJrJIO NSB HVJIp OJ In fDm NO���H H10iiS HHtO N o ��00000 aa0000000000000000000 p 3� O o 0 0 1 uV N W a o 0 0�00000000000000000000000000 F x o o 00 00�00 _ $ oo _ � o$00000 000000000000000000000 � W 00 00�00 � o0 00 � !o oi3ooaoo 000000000000000000000 GI 0 o� o >A00000 00000000000000000000� 3'� o c 1y � o m>0000000000000000000000000g W a x N 0 S_ = A y� �p Q� �(y h000000000000,00000000200008 h O O O O� O O W O O S) 00 O O O O 00 O O O O O O 00 00 O o2 00 O O O C of i 00 00000 o0 oa 0800 00oo000000000000009000op N La wrightsofe Right-M Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772466-8796 Email: OUCKCALCS@ACL.COM Job: Date: JAN. 2, 2020 By: 1 Room rerro STORAGE 2 Exposed well 16.0 8 3 Room height 10.0 It heal/ccol 4 5 Room cimensions Room area 1.0 x 29.0 ft 29.0 W Ty Construction U-value Or HTM Area (gj Load Neat Load number (BIuh/ftk'F) (BtulJft� or perimeter QQ (Stuh) or perimeter Heat Ccol Gross NIPIS Heat Cool Gross WP/S Heat Cod 6 1a44ocs 2 glazing, cir lca a 2 glazing, cir lc a 0.143 0.990 1.040 'n n n 4.00 0.00 0.00 2.19 0.00 0.00 50 0 0 50 0 0 200 0 0 109 0 0 11 2 glazing, cIr love 2 glazing, cir lave 1.040 1.110 n n 0.00 31.08 0.00 2231 0 0 0 0 0 0 0 0 2 glazing, clr lave, 13A-0ocs 1.110 0.143 n a 31.08 4.00 22.31 2.19 0 0 0 0 0 0 0 0 2 glazing, clr lave 1.040 a 0.00 0.00 0 0 0 0 zglazing, clrlcve 2 glazing, clr Iowa 1.040 1.040 a a 0.00 29.12 0.00 26.73 0 0 0 0 0 0 0 0 2 glazing, cir Inwe 2 glazing, dr lcv a 2 glazing, cir lc re 1.= 1.110 1.110 a a a 29.12 31.08 31.08 26.73 28.16 28.16 0 0 0 0 0 0 0 0 0 0 0 0 2 glazhg, dr lc a e 1.110 a 31.08 28.16 0 0 0 0 yJ 134-0ocs - 0.143 s 4.00 2.19 50 50 200 109 lL-(C z glazing, dr lore 2 glazing, dr Iowa 13A-0ocs 1.040 1.040 0.990 a s w 29.12 29.12 21.05 21.63 2.47 0 0 60 0 0 43 0 0 170 0 0 95 2 glazing, dr Iowa 0.990 w 7.72 27.72 29.47 0 0 0 0 2 glazing, cir Iowa 2 glazing, dr Iw,re 0.990 1.040 w w z. 00.0000 z.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr lour-e 2 glazing, cir laws 1.110 1.110 w w 31.08 31.08 4259 28.16 17 0 0 0 621 0 713 0 IQ/ 13k4ocs 2 glazing, dr lcve z glazing, drlm a 0.143 0.990 0.990 w4.00 w27.72 nw 27.72 2.19 24.27 24.27 0 0 0 0 0 0 0 0 0 0 0 0 f�-�Ga C 16X190md 0.408 - 1.59 1.37 29 29 46 40 F 22A4ph 1.358 - 38.02 0.00 29 16 608 0 6 c)AEDexcursion 205 Envelops loss/gain 1749 1272 12 a) In60rdlon 241 65 b) Roomventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1989 1337 Less external load 0 0 Less transfer 0 0 Redistribution -19M -1337 14 Subtotal 0 0 15 Duct loads 2(% 32% 0 0 Total mom load 0 0 Air required (rim) 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -�{+- wrrgtieaofe- 2020-Jan-02 12:54:10 A& ^^ RightSuiteO universal 2019 19.0.08 RSLI08101 Page 9 ...cumnetslWdghtscBHJACIMALDONADORESIDEN17E.mp Cale=10J8 From Doorfaces: E N N Q a m � � m T i� t 3 11 �Oo�00000000oo�ooptoo�00000Qo �ii �i7lff gl �i � �0 00 � 000�iy Sri �� < (3 OL �� O �� q�oo�0000000000goo�o oo�00000g8 � �o v 000�� �� C m o x �« .. boo 00000000000�00�00000000�� O C N a « �� 3 0 0 �oo�oo 0000000ooffioogioo�00000�� o � N'�Coom�gto 0000�ooptoo�<00000�yo ASS dd55 ��SS ��ff o goo iif op �6 000� CT b XN1 3 iN m nia � N `�3 N � _ = O �� 1, poa oo ov�0000000�oo�00000000s� in f r; rn a �3 P OS Qj fO 1OmOO Ns N0 O 0 of �N�00000jOOfj�00�00000 YS fS A p O U' �Fffiffi88�ffiffi888889288s88ffi88888m8 . � j " rq& N O. O CI � 146 O OO O N OOCl O dig d d ci do VO $FpN�$887�$$88$8$$88$7$8$6d9 �j PNN NO OOV OlO�OOOOC OCOOOGO 9OG.000 «g 1'l = �� O C C C N N O L N 3 3 3 € � � «� � yy�C ggC ggC ggN ggO ggd ggN ggN ggH 553�� }}3�� gg3 yp�� 5€' ��i d-d���dddd000�dd�tfi b(d ooFJ �S iSi�'o5 0000- � �.���Cd�fd�PoPo�.� - E a a � (gcrnrnmmwrnmwmwmwmrnrnww wmrna N N N N N< N NN NNN N < NN< NN N NN <NN < E3 a"i - 8 N m .® 9 O ` C N 55yN K R LL' E N WK�K I-� <NN PN fD 10 � em- Or U Q W m `o O O IeL wrilghtsoft Right-M Worksheet AHU 2 QUICK CALCS, INC. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUCKCALCS(AOLCOM Job: Date: JAN. 2, 2020 By: 1 Room nanre M WIC 1 M WIC 2 2 Egmedwan 10.0 ft 0 ft 3 Room height 10.0 0 heat/ccol 10.0 it bwYcod 4 5 Room dmendons Room area 10.0 x 7.0 it 70.0 fP 6.0 x 5.0 fit 30.0 fP Ty Construction U-value Or HTM Area Load � number (Bluhfft?'F) (BluWN� or perimeter (it) (Blob) orpednietter (fit) (Btuh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A flocs 2 glazing, dr ovv-e 2 glazing, dr bare 0.143 0.990 1.040 n n n ADD 27.72 29.12 2.19 21.77 21.68 100 0 0 100 O D 400 0 0 219 0 0 0 0 0 0 0 0 0 0 0 '0 0 0 G i 2 glazing, dr larva 2 glazing, cir love 1.040 1.110 n n 29.12 0.00 21.68 0.00 0 O 0 O 0 0 0 0 O 0 0 0 0 0 0 0 2 glazing, dr lov -e 13A4ocs 2 glazing, cir lcvve 1.110 0.143 1.D40 n a a 0.00 4.00 29.12 0.00 2.19 40.58 a 0 O 0 0 0 0 0 0 0 0 0 0 O 0 0 0 a 0 0 0 0 0 0 2 glazing, cir lm a 2 glazing, dr lov-e 1.040 1.040 a a 29.12 0.00 40.58 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir Io 2 glazing, cir lave 2 glazing, dr bee 1.040 1.110 1.110 a a a 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing. dr lave 1.110 a 0.00 0.00 0 0 0 0 0 0 0 0 W, 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 L�GC 2 glazin7, dr lov" 2 glazing, dr lovve 13A-0acs 1,040 1.040 0.143 s s w 0,00 0.00 4.00 0.00 0.00 219 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lorr•e 0.990 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr lave 2 glazing, dr lc a 0.990 1.040 w w QOO 29.12 0.00 40.58 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazbg, cir lave 2 glazing, c r lave 1.110 1.110 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 lQJ 13A4acs 2glazmg, cir lcxc 0.143 0.9m my m 0.00 0.00 0.00 0,00 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 2 glazing, cir b ve 0.99D m 0.00 0.00 0 0 a 0 0 0 a o C 16X190 m 0.408 - 1.69 1.37 - 70 70 111 96 30 30 48 41 F 22A4ph 1.358 - 38,02 0.00 70 10 380 0 30 0 0 0 6 c)AED excursion -29 -20 Envelope lossfgain 892 286 48 21 12 a) Infiltration 151 40 0 0 b) Room ventilation 0 0 0 0 13 Irdemal gains: Occupants 230 o 0 0 0 Appfiancesfother 200 350 Subtotal (fines 6 to 13) 1042 526 48 371 Less exlemal load 0 0 0 0 Lesstiansfer 0 0 O 0 Redistribution 0 0 0 0 14 Subtotal 1D42 526 48 371 15 Dud loads 14% 36% 149 187 14% 36Wo 7 132 Tdat room load 1191 713 1 64 1 502 Airrequined(dm) 40 33 2 24 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlgtn2.a e- 2020.1en-0212:54:10 A -'-' Right-SulteS Universal 2019 19.0.08 RSL108101 Page 11 ...cumnets\Wnghtsoft HUAC\MALDONADO RESI DENCE.rup Celc = MJ6 Fmnt Door laces: E wrightsoft• Right,J@ Worksheet AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4665796 Email: QUCKCALCS@AOLCOM Job: Date: JAN. 2, 2020 By: 1 Room name M TOILET M BATH 2 Exposed wall 4.0 0 11.0 it 3 Room height 10.0 ft heat/cool 10.0 a heatfcool 4 Room dimensions 4.0 x 7.0 ft 1.0 x 192.0 R 5 Room area 28.0 IF 192.0 fF Ty construction U-value Or HTM Area (it,) Load Am m'1 Load number (Btuh/ft? °F) (BtuhRt� or perimeter (it) (Bluh) or perimeter qt) (Btuh) Heal Cool Gross WP/S Heal Cool Gross WP/S Heal Owl 6 13A4ocs 2 glazing, dr ko 2 glazing, cir loos 0.143 0.990 1.040 n n n 4.00 27.72 29.12 2.19 21.77 21.68 40 0 0 40 0 0 160 0 a 88 0 0 110 6 0 104 o 0 416 165 0 228 131 0 2 glazing, clr lo" 1.040 n- 29.12 21.66 0 0 0 0 0 0 0 0 11 2 gaming, dr lows 1.110 n 0.00 0.00 0 0 0 0 a 0 0 0 2 glazing, clr Iw 1.110 n 0.00 _0.00 0 '0 0 0 0 0 0 0 13A4acs 2 glazing, dr by 0.143 1.040 a a 4.00 29.12 2.19 40.58 0 a 0 0 0 0 0 0 0 0 0 0 a 0 0 0 2 glazing, dr lave 2 glazing, dr lone 1.040 1.040 a a 29.12 0.00 40,58 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr lave 2 glazing, dr love 2 glazing, dr lame 1.040 1.110 1.110 a a a 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 HlazhM. cir lave 1.110 a 0.00 0.00 0 0 0 0 0 0 0 0 ILS13A4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, or lave 2 glazing, cir lave 1.040 1.040 a a 0.00 0.00 0.00 - 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 13A4as 0.9m w a 0 0 0 0- 0 0 0 2 glazing, dr loµe 0.990 w Qoo 0.00 0.00 0.00 0 0 0 0 0 o 0 0 2 glazing, cir bma 2 glazing, dr bn<e 1.040 1.040 w w 0.12 29.12 0.58 40.58 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 2 glazing, dr io s 1.110 w 0.00 0.00 (1 0 0 0 0 0 0 0 2 glazing, dr to" 1.110 w 0.00 0.00 0 0 0 0 a o 0 0 V+J �l-�Ga 130.4ocs 2glazirg, dr tome 0.143 0.9w 'av w0.00 0.00 0.00 0.00 a 0 a 0 0 0 0 0 a 0 a a 0 0 0 0 2 glazing, dr $owe 0.990 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X190nd 0.408 - 1.59 1.37 28 28 44 38 192 192 304 263 F 22A-tph 1.358 - 38.02 _ 0.00 _ 28 4 152 0 192 11 418 0 6 c)AED excursion -18 48 Envelope loss/gain 357 108 1305 573 12 a) Infiltration 60 16 166 44 b) Roomventiatian 0 0 0 0 13 Internal gams: Occupants Q 230 0 0 0 0 App5ances/other 200 250 Subtotal (lines 6 to 13) 417 324 1471 867 Less eldemal load Cl 0 0 0 Less transfer D 0 0 0 Redistribution0 0 22 18 14 Subtotal 417 324 1493 885 15 Dud loads 14% 36% 60 115 14% 36% 213 315 Trial room load 476 4� 1706 1200 Air required(cfm) 16 21 57 56 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr19F+boit- 2020Jan-0212:54:10 ' RlghtSUBe®Uni ema12019 19.0.08 RSL08101 Page 12 ...cumnetslWdghtsoR FIVAC%MALDONADO RESIDENCE.mp Cale = MJ8 Front Door faces: E wrightsofY Right-M Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUCKCALCSa@AOL.COM Job: Date: JAN. 2, 2020 By: 1 Room rame HALL 2 WIC 2 2 ExImed wall 0 ft 5.0 ft 3 Room height 10.0 ft heal/cool 10.0 ft heaticool 4 5 Room dimensions Room area 5.0 x 4.0 it 20.0 IF 5.0 z SO it 30.0 ft' Ty Construction U-value Or HTM Area (W) Wad Area (W) Load number (BtuhNt%*F) (BUMP) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross WPIS Heat Cool Gross WP/S Heat Cool 6 13A4ccs 2 glazing, driwre 2 glazing, dr for 0.143 0.990 1.040 -n n n 4.00 27.72 29.12 2.19 21.77 21.68 a 0 0 0 a 0 0 0 0 0 0 0 50 0 0 50 0 0 200 0 0 109 0 0 11 2 glazing, clr love 2 glazing, cir loxc 1.040 1.110 n n 29.12 0.00 21.68 0.00 0 a 0 a 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr [a" 13A-4acs 2 glazing, dr lawe 1.110 0.143 1.040 n a a 0.00 4.00 29.12 0.00 2.19 40.58 a a 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr lox¢ 2 glazing, dr lave 2 glazing, dr Io 2 glazing, cir Iw 2 glazing, dr lave 1.040 1.040 1.040 1.110 1.110 a a a a a 29.12 0.00 0.00 0.00 0.00 40.68 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1N 2 alazinn, cir love 13A4= 1.110 0.143 a s 0.00 4.00 0.00 2.19 0 0 0 0 a a 0 0 a a a a 0 0 0 0 2 glazing, dr lwte 2 glazing, dr lave 13A-0ocs 1.040 1.040 0 a s w 0.00 0.00 .00 0.00 0.00 2. 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 2 glazing, dr lave 2 glazing, cir bxe 2 glazing, cir bxe 0.9-990 90 0.990 1.040 w w w 00.00 . 299.1212 0.0000 0.00 40.58 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 2 glazing, dr louse 13A4ocs 2glazing, dr lave 2 glazing, drb� 1.110 1.110 0.143 0.990 0.99D w w av my rrx 0.00 0.00 a00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 a a a 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1jV II--CG C 16X19-0nd 0.408 _ - 1.59 1.37 20 20 32 27 30 30 48 41 F nmph 1.358 - 38.02 0.00 20 a 0 _ 0 30 5 190 0 6 c)AEDescursion -1 -19 Envelope loss/gain 32 26 438 131 12 a) Infiltration 0 0 75 20 b) Room ventiation 0 0 0 0 13 Indemal gains: Occupants 230 0 0 0 1 0 Appliances/other 0 1 200 Subtotal (lines 6 to 13) 32 26 513 351 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution S2 -26 0 0 14 Subtotal 0 0 513 351 15 Duct loads 149/6 36% 0 0 14% 369% 73 125 Trial room load 0 0 586 476 Air requined(dm) 0 0 20 22 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed, i+F wri9hlsoT!- 2026Jan-0212:54:10 RightSuite® Universal 2019 19.0.08 RSU08101 Page 13 ... curmetslWnghtsoft HUACIMALDONADORESIDENCEmp Calc=10J8 From Doorfaces: E m 8 A n°L1 �� 3N3 ppSE•-�ry £ � p�� o Gf 7� 41G ] •S•Sq 3m�� O1mm mm mmm m mmmmmmm mmmma 'O ' �P� _. _ as WFS�kj�� d���S Aa a� S 9 _ a2 gn2- ga R— R- $ $$ana . �� ��y, 2'�EFffF�NNNR0m0mR06 '� � ,off"+00000{$ooaooa0oom o5No �,Noaoom �,�Nia 2 {{�� �j N H H HH'HH N HH HH H H H HHH H N N HH HN N� H �� 00 NO O N O 00 O O O ONO O N — N�N p+p�� p��y+ �OI HJHHHH9 O]HHmHHmHHHHHq mH HMI OfJm e o �S'OoOoa m00000000o000oHo00moH �'� O c o � � y qy � u0^ O mHOOOm0000000000000oo�0oOo og x o� � _ � N O_Q%� O�'S• dl Fi000 � O+ ll� iS(I�OOOOO OOOOOOOOOOOOOOOOOONOO�i C� vn ^S AQ m Li �1 A +O O O �1 + H O Of O N N o N q oN ON 00 O O O OO O O 00 O O O 00 00 O+ 0 0 0 H OW Od p a 0 o Bffi00000 00000OESo 0000+m 280o0oo0 fl my � V O O 00 00 O O O O O O H O O O O O O O N O O O O O O x V O aO o Q i N jN N NyN V� 00 0 O al V N V V10 00 O 0 0 00 00 0 0 000 0 0 00 00 0 vd n (�N O� QQ�� R�O�00 � N HO O OtO �y O yN lNNJ P1p+p�� OOIOOOOO OOOOOOWOOOOO�NO1000000 _4 O O Duct System Summary Job: -�- wrightsoft Date: Jnri. 2, zozo AHU 1 By: QUICK CALCS, INC. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: OUCKCALCS@AOLCOM Project Information For. MALDONADO RESIDENCE, FLTREND HOMES 1521 DUNN ROAD (SOUTH LOT), FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1400 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1400 cfm 185 it Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1201 43 24 1.000 5.0 Ox0 VIFx 12.5 115.0 st2 BATH h 1779 63 38 1.000 5.0 OxO VIFx 37.3 135.0 sty BEDROOM 3 c 2294 74 103 1.000 7.0 Ox 0 VIFx 11.9 115.0 st3 BEDROOM 4 h 5472 195 114 1.000 7.0 Ox 0 VIFx 39.2 135.0 sty DINING h 4566 162 118 1.000 7.0 OxO VIFx 13.4 115.0 st2 GREATROOM h 5849 208 202 1.000 8.0 0x0 VIFx 21.1 115.0 SH GREATROOM-A h 5849 208 202 1.000 8.0 OxO VIFx 25.2 115.0 st1 KIDS ROOM c 2212 77 100 1.000 7.0 OxO VIFx 19.2 115.0 st3 KITCHEN c 3498 12 157 1.000 8.0 0x0 VIFx 22.0 115.0 sill NOOK c 4106 148 185 1.000 8.0 OxO VIFx 25.8 115.0 st1 PANTRY c 34 1 2 1.000 4.0 Ox0 VIFx 10.8 115.0 st3 UTILITY h 1750 62 50 1.000 6.0 Ox0 VIFx 12.5 115.0 st2 WIC h 523 19 9 1.000 4.0 Ox0 VIFx 10.9 115.0 st3 WIC 4 h 3572 1 127 97 1 1.000 1 7.0 Ox 0 1 VIFx 1 50.2 1 135.0 1 sty Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR MIT) (in) (in) Material Trunk stl Peak AVF 576 747 1.000 810 13.0 0 x 0 VInIFIx st5 Peak AVF 385 249 1.000 872 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 556 462 1.000 843 11.0 0 x 0 VinlFlx st2 Peak AVF 257 191 1.000 766 8.0 0 x 0 VinIFIX ti i#1- wrightsoft- �wM.-. Right -Suite® LIniwm&12019 19.0.08 RSL08101 ...cumnets\Wrightsoft HVAC%MALDONADO RESIDENCEmp Celc=MJ8 Front Door faces: E 202G-Jan-02 12:54:14 Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 1 1400 1400 0 0 0 0 Ox 0 VIFx wrightsoft` 2020Jan-0212:54:14 ,.� ..w•, ,•.•.-. RightS9 utta® Unwmal 2019 19.0.08 RSU09101 Page 2 ...cummetslWrightaoft FNAC1MALDONADO RESIDENCE rup CeIc=MJB Front Docr Faces: E Duct System SummaryJab. -� wrightsoft• � Date: JAN. 2, 2020 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Frei: OUCKCALCS@AOLCOM For. MALDONADO RESIDENCE, FLTREND HOMES 1521 DUNN ROAD (SOUTH LOT), FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm iWe", Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 inll0oft 627 cfm Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1984 65 49 1.000 6.0 Ox 0 VIFx 49.5 115.0 st4 BEDROOM 2 c 3209 141 150 1.000 8.0 Ox 0 VIFx 40.2 115.0 st4 M BATH h 1706 57 56 1.000 6.0 0x0 VIFx 41.1 115.0 st4 M TOILET c 439 16 21 1.000. 5.0 Ox 0 VIFx 60.5 135.0 st6 M WIC 1 h 1191 40 33 1.000 5.0 Ox0 VIFx 57.7 135.0 St6 M WIC C 502 2 24 1.000 5.0 OxO VIFx 57.1 135.0 St6 MASTER BEDROOM h 4270 143 136 1.000 7.0 Ox0 VIFx 64.4 135.0 st6 MASTER BEDROOM -A h 4270 143 136 . 1.000 7.0 0x0 VIFx 64.4 135.0 St6 WIC 2 c 476 20 22 1.000 5.0 Ox 0 VIFx 43.7 115.0 s1:4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 343 349 1.000 640 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 627 627 1.000 798 12.0 0 x 0 VinlFb( Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam .(in) H x W (in) Stud/Joist Opening (in) Duct Matt I Trunk rb1 Ox0 1 627 627 1 0 1 0 0 0 Ox 0 1 VIFx * wright sof - 202D Ian-02 12:64:14 �A•��•, ..-.�•�. RIOhtSubO Unt emat 2019 19.0.06 RSUDB101 Page 3 ...emmets\Wd9htsaft WAC\MALDOWO RESIDENCEmp Cate =MJ8 Front Door hoes: E