Loading...
HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 i Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: WZA0:5NV& MOBILE VlLl A&E- Date: / °Z/�, Q (Print or type) %5P LAKE5 Address: ad , `zUL, FORT RE-Rec. FL • 1 COvntTRY LLUBAMP, ap (Ppys- �°°off'°me) , "Tati9PlGssb�4 FL�aAi79G9 Year/ Manufacturer /T/ lTIT Serial #�Y9 P1 &5*5—o B HUD Plate # i RY! 97d Width Length Single Double Wind Zone C = In Compliance N = Not in Compliance Fire Safety / Eleptrical if 1. Smoke Detector: Installed Missing C 2. Electrical System Checked: Exposed Wiring ____Other C 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other SL 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ C 5. Electrical Ground: Chassis Main Panel Gas Pips_ Revised 319105 Page I of 3 1 py9 1 J Construction Exit Doors Operable: Front Back Exit Door Locks: Missing Inoperable Egress windows: Missing Inoperable Other 4. Windows: Broken Glass Inoperable S_ 5. Screens: Missing Damaged_ 6. Floor System: Joist Decking Area Damaged _ 7. Interior Paneling: Missing _ Loose _ Damaged_ G 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other ii 9. Leaks Apparent: Ceiling_ Doors_ Floor _ Roof e'- 10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NO 12. Walls: Structurally Unsound —Loose —Weather tight Plumbing 1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing _ Not installed _ Not Vented �3. Relief Valve: Missing Inoperable Other _ 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning -f, 1. Heating Appliances: Missing Not Connected 2. Deleted Heating/AC system: Not installed Other --C_ 3. Thermostat: Missing Inoperable -_C_ 4. Air registers: Missing Inoperable —S�- 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 C 6. Gas furnace Water heater vent: Missing �i 7. Return Air: To Furnace To A/C �L 8. Range: Vent Hood Loose From rooms C 9. Gas Valve: Accessible Installed improperly S� 10. Gas lines: Not capped Not supported Kinked Notbonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO 2. Willa remodeling permit be required? YES NO___V" The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: a blig Inspected By: V J Map L, Masignwe requfred3 alPhone Number: 5-7 License # 'WA *�7t' Engrneem Seal Page 3 of 3 STEVEN G. WOOD, P.E. FL LICENSE W98 960 SULTAN DR pORT ST LUCIE, FL