Mobile Home Inspection Report
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone II certified.
Owner: WZA0:5NV& MOBILE VlLl A&E- Date: / °Z/�,
Q (Print or type) %5P LAKE5
Address: ad , `zUL, FORT RE-Rec. FL • 1 COvntTRY LLUBAMP,
ap (Ppys- �°°off'°me) , "Tati9PlGssb�4 FL�aAi79G9
Year/ Manufacturer /T/ lTIT Serial #�Y9 P1 &5*5—o B HUD Plate # i RY! 97d
Width
Length Single
Double
Wind Zone
C = In Compliance
N = Not in Compliance
Fire Safety / Eleptrical
if 1. Smoke Detector: Installed Missing
C 2. Electrical System Checked: Exposed Wiring ____Other
C 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_
Unplugged Opening Other
SL 4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire_
GFCI receptacles not where required_
C 5. Electrical Ground: Chassis Main Panel Gas Pips_
Revised 319105
Page I of 3
1 py9
1
J
Construction
Exit Doors Operable: Front Back
Exit Door Locks: Missing Inoperable
Egress windows: Missing Inoperable
Other
4. Windows: Broken Glass Inoperable
S_ 5. Screens: Missing Damaged_
6. Floor System: Joist Decking Area Damaged
_ 7. Interior Paneling: Missing _ Loose _ Damaged_
G 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other
ii 9. Leaks Apparent: Ceiling_ Doors_ Floor _ Roof
e'- 10. Vertical tie -down straps: Missing _ Short _ Damaged_
11. Structural modifications since manufactured: YES_ NO
12. Walls: Structurally Unsound —Loose —Weather tight
Plumbing
1. Trap: Missing Not connected Other
2. Plumbing fixtures: Missing _ Not installed _ Not Vented
�3. Relief Valve: Missing Inoperable Other
_ 4. Drain Waste and Venting Piping: Missing Not supported_
Clean outs _ Use of fittings _ Not capped_
Heating and Air Conditioning
-f, 1. Heating Appliances: Missing Not Connected
2. Deleted Heating/AC system: Not installed Other
--C_ 3. Thermostat: Missing Inoperable
-_C_ 4. Air registers: Missing Inoperable
—S�- 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
C 6. Gas furnace Water heater vent: Missing
�i 7. Return Air: To Furnace To A/C
�L 8. Range: Vent Hood
Loose
From rooms
C 9. Gas Valve: Accessible Installed improperly
S� 10. Gas lines: Not capped Not supported Kinked
Notbonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO
2. Willa remodeling permit be required? YES NO___V"
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: a
blig
Inspected By: V J Map L,
Masignwe requfred3
alPhone Number: 5-7
License # 'WA *�7t'
Engrneem Seal
Page 3 of 3 STEVEN G. WOOD, P.E.
FL LICENSE W98
960 SULTAN DR