Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
.y +�- wrrightsoft° Project Summary o te: Enure House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORrPIERCE, FL34946 P1ure: 772-466-6799 Email: QUICKCALCSQAOL.COM Proiectinforrilititiod For. WINDSONG MOBILE VILLAGE 3200 S. 7tH STRE 'LOT'#50 FT. PIERCE, FL 34982 adoa. o►qy MAR 02%"` Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outsidedb 90 OF Insidedb 70 OF Insidedb 75 OF Design TO 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16548 Btuh Structure 21239 Btuh Ducts 5308 Btuh Ducts 7599 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 21855 Btuh Use manufacturer's data n Ratelswingg multi Her 0.95 Infiltration Equipmentsensibleload 27396 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2077 Btuh Ducts 2043 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft�) 1380 1380 Equipment latent load 4121 BWh Volume (fN) 12972 12972 Airchangeslhour 0.45 0.23 Equipment Total Load (Sen+Lat) 31517 Btuh Equiv.AVF (cfm) 97 50 Req. total capacity at0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GPC1442M41A AHRI ref Coil AHRI ref 201186877 Efficiency 100 EFF Efficiency 11.0 EER,14 SEER Heating Input 5A kW Sensible coaling 28000 Btuh Heatingoutput 18335 Btuh Latent000ling 12000 Btuh Temperature rise 13 OF Total cooling 40000 Btuh Actual airflow 1333 cfm Actual airflow 1333 clan Airflowfactor 0.061 cfmBtuh Airflowfactor 0.046 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 4F weight aft' 2020-Feb-2813:18:43 AC40K •'^^- ••^^-• RigtiSube®Uriv ml201919.0.07RSU08101 Paget ...rt1W6gltsoftHVAC1WINDSONG MOBILE LOT#50np Calc=W8 FroriDJUrfamSSE wrightsoftRight-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: OUICKCALOS AOL.COM Job: Date: By. 1 Room name Enlin: House LOT#5 2 E)posed wall 202.0 ft 90.0 It 3 Room height 9A ft 9.4 A heaV000l 4 Room dimensions 12.0 x 52.0 ft 5 Room area 1380D fe 624.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhw-`F) (BluhAn or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cod Gross NIPS Heat Cool Gross NIPS Heat Cod 6 V 12B-0sv 0.097 ne 2.72 2.34 724 676 1837. 1581 489 441 1199 1032 1AaIcm 1270 ne 35.56 7043 8 " 0 292 579 8 0 292 579 1AcIom 1270 no 3556 70.43 28 0 996 1972 28 0 996 1972 IF��_GG W 11 1AcIom 12B.Ow 1270 0.097 ne se 3556 2.72 70.43 2.34 11 226 0 226 400 613 792 527 11 113 0 113 400 306 792 264 12B-0sw 0.097 sw Z72 2.34 724 667 1812 1560 132 132 357 308 1Aclom 1270 sw 35.56 45.32 9 .6 311 397 0 0 0 0 Ti 1Aclom 1270 sw 35.56 48.52 14 9 498 679 0 0 0 0 vI/ 1Ac1om 12B-Ow 1270 0.097 sx. nw 35.56 2.72 51.01 2.34 34. 226 19 185 1200 503 1722 433 0 113 0 99 0 268 0 231 I�--GG C 1Ac1cm 1Ac1om 17B-2021 1270 1270 0.043 nw nw - 35.56 35.56 120 70.43 70.43 1.03 25 14 13BO 0 0 1380, 933 498 1632 1849 986 1424 0 14 624 0 0 "624- 0 498 751 0 986 644 F 19A-11bsw 0.073 1.45 0.78 1380 1380 1999 1071 624 624 904 484 6 c)AED exnrtsion 2448 -103 Envelope losstgain 13554 18020 5972 7188 12 a) Infiltration 2994 820 1334 365 b) Roomeentlafion 0 0 0 0 13 Internal gains: O=pants@ 230 0 0 0 0 Appliances(other 2400 1200 Subtotal(lines6 to 13) 16548 21239 7305 8754 Less wdemal load 0 0 0 0 Lesstmnsfer 0 0 0 0 Redistribution 0 0 01 0 14 Subtotal 16548 21239 7305 8754 15 Dudloads 32% 36%1 5308 7599 32% 36% 2343 3132 Tohal room load 21855 28838 9649 118BB Airrequired(dm) 1333 1333 589 550 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. c -i'{+- wright�o>Ft^ 2020-Feb-2813:18:43 Rig"LiteOUdwrsal 201919.0.07 RSU08101 Page 1 ...rts\WrigWoftWAC\WINDSONG MOBILE LOT#50xup Calc=WB Frort Doorfaces:SE •- # wrightsoft Right-l@ Worksheet Job: Entire House Date: ey QUICK CALCS, INC. 317ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-066-6799 Email: OUICKCALCS@4OL.COM 1 Room name LOT 2 EVosedvall 112.0 it 3 Room height 9.4 8 heaV000l 4 5 Room dimensions Room area 12.0 x 63.0 ft 756.0 ft Ty Construction U-value Or HTM Area (ft?) Load Area Load number (B1uhRt;°F) (BIuhV) or perimeter (it) (Stuh) or perimeter Heat Cool Gross N/PS Heat Cool Gros NIPS Heat Cod 6 VI1 12B-0sw tActom 1Ac1om 0.097 1270 1270 no ne no 2.72 3556 35.56 2.34 70A3 70.43 235 0 0 - 235 0 0 638 0 0 549 0 0 I��------GGG 11 W 1Actom 1213Osw 1270 0.097 ne se 35.56 272 70.43 2.34 0 113 0 113 0 306 0 264 vt/ 123-0sw 0.097 sv Z72 '2.34 592 536 1455 1252 1Ac1om 1270 sv. 35.56 45.32 9 6 311 397 Ilt---GGG 1Aclom 1270 sw 3556 48.52 '14. 9 498 679 l�l 1Ac1om 12Mw 1270 0.097 sx nw 35.56 2.72 - 51.01 2.34 34 113 19 87 1200 235 1722 202 1Aa1om 1.270 nw 35.56 70.43 26 0 933 1849 L�GG 1Aclom 1270 nw 35.56 70.43 0 0 0 0 C 17B-20b _ - 0.043 120 ._ '1.03 756 756 910 780' F 19A-11bs4o 0.073 - 1.45 0.78 755 756 1095 587 6 c)AEDe rson 25W Emdope losstgain 7582 10831 12 a) Infiltration 1660 455 b) Roomwntlafion 0 0 13 Intemal gains: O=pants@ 230 0 0 Applianceslother 1200 Subtotal (lines 6 to 13) 9242 12486 Les codemal load 0 0 Lestransfer 0 0 Redistribution 0 0 14 Subtotal 9242 12486 15 Dudloads 32% 36% 2964 4467 Total mom load 12207 16953 Air required (cm) 745 784 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -M}F- wrightsoft' 2020-Feb-2813:18.43 .SC A "'""° "_• ""-^ Rgrt-Sufe®Udvers1201919.0.07 RSU08101 Paget .xislWrigMwftHVAQWINDSONG MOBILE LOT#50.np CeIc=W8 FrortDooffaces:SE