HomeMy WebLinkAboutTest and Balance Report 0qS9 SALASO'BRIEN 3501 Quadrangle Blvd., Suite 100 Orlando, Florida 32817 expect a difference 407.380.0400 1 www.salasobrien.com April 21, 2020 SHOP DRAWING REVIEW COMMENTS _RE CEIVrD Reference: St. Lucie County Airport Forensic Analysis 2020 Salas O'Brien Florida #15072 Subject: Final Test and Balance Report Submittal MAY 01 2020 Reviewed By: Kyle J. P.E. Y Cartier,Y ST. Lucie County, Permitting Engineer's review is for general conformance with the design concept and contract documents.Markings or comments shall not be construed as relieving the Contractor from compliance with the project plans and specifications, nor departures therefrom. The Contractor remains responsible for details and accuracy, compliance with the Contract Documents and intent,for confirming and correcting all quantities and dimensions,for selecting appropriate fabrication processes,for techniques of assembly,and for performance of work in a safe manner. OVERALL DISPOSITION: Revise and Resubmit 1. Verify the recorded values for AHU-1. The summation of the outside air (1,852 CFM) and return air (4,665 CFM) exceed the supply air from the unit (total of outside and return is 6,517 CFM, recorded supply is S,341 CFM). The summation of the return air from the AHU- 1 table is 2,808 CFM, which is not consistent with the value recorded in the AHU-1 data sheet (4,665 CFM). 2. It is noted that the final total supply air for RTU-1 is considerably lower than design (73%). 3. There is a difference of 356 CFM between the recorded RTU-2 supply air (1,986 CFM) and return air(1,630 CFM). This implies that the outside air damper on RTU-2 is not completely closed. Ensure the outside air damper on RTU-2 is completely closed and sealed and re- measure to ensure the supply and return airflow values are the essentially the same. 4. It appears exhaust fans EF-1, EF-2 and EF-3 have not been rebalanced to their respective new airflows as required by sheet M1.1, Plan Reference Notes 14, 13 and 15 respectively. Rebalance exhaust fans to values indicated, record and re-submit for review. S. The Outside Air Unit test data is missing the entering and leaving dry bulb and wet bulb air temperatures across the unit heat pipe coils. Measure and record these values and include in the test report for evaluation. Refer to sheet M4.1, Grade Mounted Package 100% Outside Air Unit Schedule for indicated values across the pre-cooling and reheat coils. 6. Confirm the 52 degree off-coil temperature indicated in the Outside Air Unit report form is the temperature leaving the DX cooling coil prior to entering the heat pipe reheat coil. 7. Measure and record the total unit amp draw and voltage at design conditions. It appears the recorded values for amps and voltage are for the evaporator fan only. Refer to sheet M4.1,Grade Mounted Package 100%Outside Air Unit Schedule for unit design MCA value. Shop Drawing Review Comments Page 2 of 2 8. Rebalance total airflow from the Outside Air Unit to within 10% of the total design (1,540 CFM maximum) as opposed to the 1,852 CFM recorded. END OF DOCUMENT OMEGA AIR SERVICES LLC DBA OMEGA TEST AND BALANCE NNNA CERTIFIED INDEPENDENT TES TAND BALANCE COMPANY--- 126 WISTERIA AVENUE, FORT PIERCE, FLORIDA 34982 CELL (772)216-7632 TABB CERTIFICATION NO. BB032001C www.omegaairserviceslic.com omegamaniac532002@vahoo.com TESTING, ADJUSTING, AND BALANCING REPORT ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS FORT PIERCE, FLORIDA MECHANICAL ENGINEER: SIMS WILKERSON CARTIER ENGINEERING INC. 12124 HIGH TECH AVENUE, SUITE 200 ORLANDO, FL 32817 MECHANICAL CONTRACTOR: GRIMES HEATING & AIR CONDITIONING 3054 NORTH US HWY. ONE FORT PIERCE FLORIDA 34946E ELECTRONIC SHOP DRAWING REVIEW / By:Salas O'Brien REVISE AND RESUBMIT j rs re w is!or geneml conformance.,in the design concept and d menu Markings o menb shall no,be constrved a [heu Cantactor wi,h the proct plans and tioru,nor departuIt rofrnm. 4-9-20 tractor remains responsible fr details and accuracy,compliznce Contact Documents and intent.for confi,ming ad cometting aes a,d ciimenoons.ro wl,cting appmprute fabrication p,xesses, niques ofassembly,and for pedom .of work In a safe manna,Kyle J.Cartlair,P.E. Ayr Y1,=020 --TILL WORK PERFORMED IN ACCORDANCE WITH TABB STANDARDS AND PROCEDURES-- c�-r HUGH GRIMES TABB TECHNICIAN BAt0A7t510T SFPTFMRFR t0.7(yl TESTING,ADJUSTING AND BALANCING BUREAU HVAC EMPERTISt "THE PROFESSIONAL'S CHOICE OMEGA AIR SERVICES LLC DBA OMEGA TEST AND BALANCE NNNA CERTIFIED INDEPENDENT TESTA ND SA LA NCE COMPA N YNNN 126 WISTERIA AVENUE, FORT PIERCE, FLORIDA 34982 CELL (772)216-7632 TABB CERTIFICATION NO. BB032001C/BB032002S/BB1032610T www.omeciaairserviceslic.com omecjamaniac5320020vahoo.com ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL TEST AND BALANCE INSTRUMENTS SHORTRIDGE SERIES 8400 FLOWHOOD W/ADM860 AIR DATA MULTIMETER RANGE: 0 TO 61 IN H.G ACCURACY: 0.05% FS CALIBRATION DATE: SEPTEMBER 8, 2019 CHECK-IT DIGITAL PSYCHROMETER—MODEL #622 RANGE: 35° TO 205° F, 5% TO 100% RH ACCURACY: ±20 ±1 DIGIT t30/o CALIBRATION DATE: AUGUST 8, 2018 SHORTRIDGE ADT446 TEMPROBE RANGE: -200 TO 1800 F ACCURACY: t 0.50 FROM 320 TO 1580 F CALIBRATION DATE: AUGUST 8, 2018 FLUKE 322 CLAMP METER HUGH A. GRIMES, CERTIFIED T.A.B.B. CONTRACTOR/SUPERVISOR/TECHNICIAN --ALL WORK PERFORMED IN ACCORDANCE WITH TABB STANDARDS AND PROCEDURES-- HUGH GRIMES TABB TECHNICIAN B61032610T SEPTEMBER 30.2021 TESTING,ADJUSTING AND BALANCING BUREAU 0" EXPERTISE "THE PROFESSIONAL'S CHOICE"" HUGH GRIMES TABB TECHNICIAN 810326101 SEPTEMBER 30.2021 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL AIR HANDLING UNIT MAKE CARRIER MODEL 40RUAA16 SERIAL 1112UO9486 SHEAVE 7 X 1 BELTS 1/A46 FILTERS i" MAKE I FR GE 56 HP RPM 3.7 1750 V PH HZ 208-230 3 60 FLA SF 10.6 1.15 SHEAVE 3 3/4 X 1 CL 17 HEAT 2.76 KW ELECTRIC i SA CFM 5750 5341 OA CFM 1400 1852** RA CFM 5225 4665 EXT.SP NA 1.84 DISC. SP NA 1.67 SUCT. SP NA -.17 OAT DB WB NA 88.1 80.1 RAT DB/WB NA 72.3/61.8 LAT DB WB NA 54.1 53.6 FAN RPM NA NA VOLTS 208 210 AVG. AMPS 10.6 8.6 AVG. MODEL SERIAL V PH HZ RLA LO PRESSURE HI PRESSURE REFRIGERANT FAN HP RPM V PH HZ REMARKS:MTR. PULLEY FULLYCLOSED. ** SEE NOTES ON OUTSIDE AIR UNIT. ALL WORK PERFORMED IN ACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN BII 7fiinT SFPTFMRFR in-zon ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS AHU-1 SUPPLY ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 101 1 SW 900 822 106 2 SW 900 702 7 121 3 SW 900 808 7 117 4 SW 900 803 8 NA 5 CD 100 82 ill 6 CD 150 130 9 110 7 CD 100 72 106 8 CD 150 66 13 103 9 CD 125 100 12 107 10 CD 175 143 47 107 11 CD 175 146 9 108 12 CD 175 140 0 112 13 CD 75 54 115 14 CD 175 144 1 116 15 CD 275 218 1 116 16 CD 275 232 2 109 17 CD 75 78 1 102 18 CD 125 123 31 5750 4863 REMARKS: NOTE REVISED FUTURE OUTSIDE AIR SETPOINTS COULD EFFECT THE FINAL NUMBERS ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABS TECHNICIAN B10i7610T CFVTFMRFR tR 7071 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS AHU-1 RETURN ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 116 1 RG -600 -549 116 2 RG -600 -536 348 115 3 RG -175 -155 1 99 108 4 RG -175 -159 ;104 107 5 RG -350 -313 '203 101 6 RG -750 -659 428 101 7 RG -750 -655 425 101 8 RG -750 -680 442 104 9 RG -750 -686 445 106 10 RG -325 -273 fi177 -5225 -4665 REMARKS:NOTE LOWER RETURN VALUES ARE MEASURED WITH OUTSIDE AIR UNIT PRODUCING WHAT IS REPORTED ALL WORKPERFORMED MACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 �k Di HUGH GTABB TECB1n2�A1nT SFPi ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS RTU-1 SUPPLY ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 117A 1 CD 250 145 117A 2 CD 250 151 90* 117A 3 CD 250 149 69* 117A 4 CD 250 156 89* 117A 5 CD 250 138 82* 117A 6 CD 250 137 i77* p 1500 876 4 REMARKS: ---RTU-1 NOT ACCESSIBLE FOR TESTING. ---EAT @ 74.3 ---LAT @ 57.5 NOTE;EXISTING EQUIPMENT UNIT HAS VARIABLE MOTOR DRIVE Test and Balance has no access to these systems. SEE PRELIMINARY REPORT ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN 81(l37f;jQT SFPTFMRFR In 7071 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS RTU-1 RETURN ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 117A 1 RG -725 -561 117A 2 RG -725 -516 -1450 1 -1077 REMARKS: ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN 61Rv610T SFVTFMRFR i0.2n71 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS RTU-2 SUPPLY ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 124 1 CD 175 87 124 2 CD 175 70 133 ATOS 3 CD 150 50 97 126 4 CD 175 51 131 124 5 CD 175 66 1113 99 124 6 CD 175 108139 102 7 CD 175 168171 102 8 CD 125 78114 119 9 CD 125 71109 120 10 CD 125 68 123 11 SW 225 239 217 123 12 SW 225 256 "216 123 13 SW 225 269 211 126 14 CD 125 38 96 Lu- 2000 1619 6 REMARKS: ---RTU-2 NOT ACESSIBLE FOR TESTING. ---EAT @ 73.7 ---LAT @ 55.1 ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN 810126101 SEGTEMBER 30.M21 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS RTU-2 RETURN ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 124 1 RG -575 -265 124 2 RG -575 -208 548 1 102 3 RG -550 -406 S23 -1700 -879 REMARKS: ALL WORK PERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN B1Ri761I1T SFFTFMRFR iR.M21 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS EF-1 EXHAUST ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 105 1 EG -200 -137 103 2 EG -75 -61 -275 -198 REMARKS: ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN einamu SFPTFMRFR 4tl_M71 ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS EF-2 EXHAUST ADDRESS OUTLET TYPE DESIGN PRE. FINAL NUMBER CFM CFM CFM 102 1 EG -75 -74 NA 2 EG -100 -113 113 NA 3 EG -100 -67 67 r E -275 -254 REMARKS: ALL WORKPERFORMED INACCORDANCE WITH TABB STANDARDSAND PROCEDURES 1 HUGH GRIMES TABB TECHNICIAN BinminT 9FPTFMRFR 7R.M7I ST. LUCIE COUNTY INTERNATIONAL AIRPORT TERMINAL PRELIMINARY READINGS AIR OUTLETS EF-3 EXHAUST ADDRESS OUTLET TYPE DESIGN PRE.i NAL NUMBER CFM CFMFM118 1 EG -75 * 41 119 2 EG -100 -7570 120 3 EG -125 -13023 119 4 EG -100 -14431 120 5 EG -125 -8980 i -525 -438 1144S REMARKS: ---*NO ACCESS ALL WORK PERFORMED IN ACCORDANCE WITH TABS STANDARDS AND PROCEDURES a\C�rtMc_. HUGH GRIMES TABB TECHNICIAN B1032610T SEPTEMBER 30,2021 OUTSIDE AIR UNIT REMARKS: ST.LUCIE AIRPORT MAKE AAON MODEL RNA 011 SERIAL 201909 SHEAVE DD BELTS DD FILTERS NA MAKE I FR NA HP RPM 1 NA V PH HZ 230\3\60 FLA SF 4.2 SHEAVE DD CL DD HEAT NA SA CFM 1400 1852 OA CFM 1400I1852 RA CFM INA EXT.SP INA DISC.SP INA SUCT. SP INA OAT DB WB 95 85 84.6 77.8 EAT DB/WB 95\85 84.6\77.8 LAT DB WB 52.3 52.2 52@COIL* FAN RPM NA NA NA NA NA NA VOLTS 230 210 AVG. AMPS NA 2.1 AVG, MAKE MODEL PLEASE NOTE WE DO NOT SERIAL TEST THE REFRIGERANT V PH HZ SIDE RLA LO PRESSURE HI PRESSURE REFRIGERANT FAN HP RPM V PH HZ CC HEAT AMPS NOTE.•LAT @ DISCGARGE=68 160.1 DURING TESTING SETPOINTS BY OTHERS Unit a/arm/shut down if drive setting below 35 Hertz Building pressure+.019 ALL WORKPERFORMED INACCORDANCE WITH TABS STANDARDSAND PROCEDURES