Loading...
HomeMy WebLinkAboutConstruction Plansrl4 TRF 9n17 FI-ORIDA BUILDING CODE 1 VE HAVE REVIEWED THE POULISPA PLAN IND APPROVE ALL ELEVATIONS, DEPTHS, IND DIMENSIONS TO BE CORRECT UNLES )THER WISE NOTED ON PLAN. - - FILTRATION PUMP FHPM .75 ---FHPM yi F1iPM 2.0 2.�tk' (qW Speetl FHPM 1.5 N: FHPM 1.0 N PM 10 x$ FHPM1., S W 20 30 40 50 W 70 00 W 1W 110 120 130 1N1 IN 1W 170 1W IN 200 210 220 230 240 250 i FLOW GPM - - c 0 D 1 i E EQUIPMENT LAYOUT LEGEND M.T.S. 4 1. 2.5" POOL SUCTION LINE 2 1 %" VAC LINE '! 3. 2' SKIMMER LINE - 4. 2" RETURN LINE TO FIRST TEE A. JANDY 1.0 FHPM VARIABLE SPEED WIAPPR H 110,W STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. VALVES (TYP) _ E. JANDY "TRU CLEAR" SALT SYSTEM (2) MAIN MIN. T AI WASTE, MME! 1 iL 6 25 ft. 1 it #n. 41 ft. M r� I 2•' SKIMMER 15" I 9 ft. 28 ft. 66H DEEP 4 c 3'6" DEEP to c 3. M r 2.6" - r TILED STEPItbi3ES VAC I SUNSH LF TILED BENCH EDGE x _ COLOR LED LIGHT 7ft: _ 13 R.6 in. R 6ft. 1ft. 5 '... CONCRETE FLOCRETE WITH OVERPOUR COPING m 1 5 DECO DRAIN iA POOL BARRIER PER FRC 4501.17-41.1.17.3 AND Ir ANSI/NSPI 15-1995 1 ! FLO-CRETE COVERED SAFETY BARRIER PER FRC 4501.17- P LANAI AREA 4501.17.1.15 & ASTM5034-95, ASTM D3787-89, ASTM 653-96 I*LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 BURIED POWER LINES SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE APPROVED WITH FBC W14 WATERLINE 20max. 18� N.T.S. 1,,�, N.T.S. HOLD 35 PSI FOR AT 9LKTIUCAL DIAGRAM AND GFl NOTE: POOL PUMP MTOR LOCATED ABOVE GRADE. PROVIDE SPARATE CIRCUIT FOR N��' REMOVE C'�� g 114. P • PER SLOP - EAST 30 MIN. O ELl ET PER 2014 NEC (NO SCALE) PUMP MOTOR(SND HEATERS) ETC WELL POINT PLUG FROM MAIN ' DRAIN & ATTACH AUX. PUMP . .' RAIN TIGHTOUTDOOR NOTE: INSTALL 125V 1S DNE WHEN EMPTYING POOL 6"X6" TILE .', - -- m LECTRICAL PANEL AMP WEATHERPROOF. ® (SIZED PER LOAD) DUPLEXRECEP7AGLEAT CONCRETE FL ETE TO MAIN SEL IN GdLEAST10-AWAYAND INTERIORAPPROVEDSIZED DECK PERLOAoouRr NOT MORE THAN 20' GRATE SHALL FINISH TYQICAL WALL 7DOORTMnEt�K FROM THE INSIDE WALL BE SECURED IN -SECTION & WIOL DGHT IN \ OF.THE POOLPLACE ;FILTER(SiAU CONDUIT POM SO - WELL POINMOTOR 41N THAT TOOLSULAPCK (NO SCALE) BOX ARE REQUIRED FORDIECMO NOTES:TOWE(1) FOR REMOVAL STEEL-TEX FORM POOPANEL AND SWITCHES MUST BE AT RKRAFTWALL LEASTSROMTHEINSIDEWALLOFTHEPOOL (2) ALL EECERICAL WIRING AND EQUIPMENT #3 @ 12" O.C.B. W. POOLD HTSWITCH� MUSTINEALLEDINACCORDANCE WITH THE NOTE:FOR DEPTHS - UNDERWATER EITHER INDOOR OR 2M4 MON OF THE NATIONAL ELECTRICAL THREADS LIGHT ouT000R CODE REATER THAN W ADD 1- HAIR & LINT APPROVED WIRING IN r• (3) PROVE PROPER WORKING CLEARANCE PLUG #3 COVE BAR @ 6" O.C. CATCHER SCH W Pvc W1 BONDING CONDUCTOR SPACESOR ELECTRICAL EQUIPMENT AS PER TO PUMP—► 3ONENT OF PUMP) Ho-26oNFPA To GRAVEL BED I� ! • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 61h EDITION SPECIFICATIONS .WIDTH 15' MAXLENGTH 28`I DEPTH 3.5' MAX. DEPTH 5.5' PE CUST ELEVATION T.B.ID1 FROM EXCAVATION STOCKPILE' GEM FINISH GEM FILTER C 2i!10 P MAKE PER FBC 4501.20 P HP- POOL (1)PLO PWA-0 HP MAX 98 GPM MAIN DRAIN: POOL : 1 iSPA - NA SKIMMER (1) RETURNS: POOL 31 SPA 1� JETS: POOL NA SPA NAB NK NA NA i SLIDE LOSURE NA ED'(5 ELECTRIC CONl�RETE FLO-CRETE f 10 FLO-CRETE EXISTING CONCRETE NA ACITY-POOL '11,470 GAL. ACITYSPA N LATE -- — 6 hrs F A. ALLEN ENGINEERING LLC, CA NO.33042, _ LAYOUT 2367 7TH STREET, LA VERNE, CA, 91750 • G �'1 EQ TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. EQUIPMENT :;T. PAD PE RM SALT q _ +i n SYSTEM POOL .... EQUIPMENT \' ANCHORED PERFLORIDA BUILDING CODE 201761H EDITION 30" MIN WATER •99 CLEARANCE IN FRONT OF SUBPANEEL p{Y`� //7/Z-OLD L.✓ Aaron H. Allen PE, FL Reg. No. 86620 FL pR JOB NAME: BRENDA TNT REv,EW�pL pNCE ADDRESS: 4810 EDWARDS ROAD G®n11 PERMIT NO. clovevG1E CO DATE DRAWN: NOVEMBER 25, 2019 DRAWN BY: TRAVIS LEONARD 2� DESIGNER APPROVAL: OP JP CUSTOMER APPROVAL: 10� SCALE: 1/4" =1' G CONCRETE POOLS INC. POOL OATIODECK 1 ROW OF WATERLINE TILE WATERLINE _ , �j 3.5 a i," THICK FROM/ R LIGHT WA 1" LIGHT POWER STEEL @ 12" O/C E.W. 5'� HALL 1 CONDUITALL UNDERWATER FLOOR SLOPE ��"" 6" THICK O},�C SH�L_LFLOOR SLOPES 09 L LIGHT DETAIL REASONABLY URLFORM.ANO R TER COMPLYWITH ARTICLES SA H N11 (NO SCALE) THRU 6.6 3 CYCOLAC MAIN DRAI APPROVED 25' 3' GROUND CLAMP LHESLOPE_OF 721 FLOOR RION 7H6 S69L4QIN:EN ALL -� TOWARDS THE DEEP AREA SHALL CONTINUOUS BOND WIRE NOT EXCEED I FOOT IN 7 FOO I 28. COMMON TO POOL STEEL, - 3j1 RAILS&EQUIPMENT ______ _�.______—_________ L7