Loading...
HomeMy WebLinkAboutPLANS (ENCLOSURE) ZgZ"I �;f-l�: WMV LP FL-A- Llc. nUME3E4Z 49497 p,s '°& ' ;' 1". ...._.:_._ CAA. ;RF L('st5257 Dv Kann m gawc_, LLc P_v. BvR I vvs� f T�eTriR F P , L 336s9 V r lSb�+�h �AV _ (813) 875-9955 Digitally Do signed by Do Kim -,! Date: 2020.04.2 LKim 9 16:00:11 i f 04'00' z�J,�7x,�, > (�AAWSAF.V R­DF) w tUk xsv Y7. g� re y y 3 ` CORNER POST EAVE RAIL S�ME BEAM STITCHING SCREWS (SEE TABLE) @ 24' O.C. (11 TOTAL) - #12 x �4 S.M.S AS SHOWN (Yz' MIN, SPLICE PLATE (EACH SIDE OF BEAM) A DO KIM I) PATIO SECTION PLATE EDGE DISTANCE & SPACE SCREWS ,q A 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS v C-C FASTENER SPACING) EQUALLY (TYP.) / & ASS❑C I ATE S, L L C COLUMN 1 °o ° 6' x s x o.oso o. —� CONSULTING 6063-T6 ALLOY PLATE _ ° a (ONE SIDE) OR STRONGER A a P w STRUCTURAL K-BRACE ENGINEERS 3' x 3' x 0.050' MIN. 6063-T6 ALLOY 0 Fp m PLATE DR STRONGER ONE SIDE) WITH 2x3XO.07O CHAIR RAIL O <- F —Q (3) - #12 x 4p' SAS, EACH SIDE AS 0 PO Box 10039 SHOWN (%' MIN. PLATE EDGE DISTANCE K-BRACE 0 Tampa,FL 33679 & C-C FASTENER SPACING) 0 0 0 { <.�Q� #14x3/4' SCREWS Tel:(813)374-0321 K-BRACE OO O O OJP, CORNER POST �y151 BEAM LINE LINE SCREWS PLATE Rev./Date Description 3' x 2' x 0.050' MIN. 6063-T6 5G�Q. ( 7/27 A � "A' °B"&'C' TOTAL WIDTH ALLOY PLATE OR STRONGER Pp� 1fy' l**> OR 2' 2x4 3 2 24 12' 115 ISSUED CONE SIDE) B 9Q ' JN� RVS 10(PL F 2x5 3 3 32 14' (3) - #12 x 3/4' S.M.S, K-BRACE CtV `*� #1Ax<, 2x6 4 3 40 14' 0 EACH SIDE AS SHOWN P *** 2x7 5 4 56 16' (Y2' MIN. PLATE EDGE GIRT (CHAIR RAIL) B ��NEtN DISTANCE & C-C SE`N�0 2x8 5 5 64 16' FASTENER SPACING) 2x2xO.093 2x9 5 6 72 18' o BRACE(TYP.), MANSARD BEAM 2x9(HW) 6 7 88 18' o ° UNLESS °° ° 1" x 2' OLE PLATE OTHERWISE CONNECTION DETAIL 2 OTED x10 7 7 96 18' 0 ■ SEE ELEVATIONS FOUNDATION FOR 'K' BRACE SIZE (3) #12A" S.M.S., EACH LEG AND MIN. (4) LONG S.M.S. INTO SCREW BOSSESSSES (TYP. ALTERNATIVE) (6) #12A" S.M.S. CHANNEL TO BEAM (9) SCREW TOTAL ' 0 CONCRETE ANCHOR (2 PLACES) BEAM STITCHING ® O.C. (TYP. TOP AND BOTTOM OF SMB J IN LIEU OF TYP. Y4' 0 CONCRETE 2x3x0.070 SEE TABLE FOR SIZES) SCREWS FOR CORNER COLUMN PURLIN W U p c: W LATERAL"K" - BRACING 1x1x1g" BY 2" LONG ANGLE, EACH SIDE (TYP.) 4(SEEPLAN) GIRT/CHAIR RAIL 0 CONNECTION DETAILS U1x14" BY 3" LONGBRAKE-FORMED RECIEVING CHANNEL ANGLE, EACH SIDE (TYP.) � O (MIN. 0.062" MATERIAL THICKNESS) a)1" x 2 1/8" x 1" x 3" LG. (3) #12x1¢" S.M.S., EACH V (TYP. ALTERNATIVE) LEG (6) TOTAL (TYP.) Z W 10x2" LONG Z S.M.S. INTO SCREW BOSSES W (4)SCREWS S.M.S., (TYP. ALTERNATIVE) H2 '� -" 2 SCREWS c Z Of EACH LEG (TYP.) S.M.B. POST 0 O V HOLLOW POST a I— co <TYP, PURLIN TO ROOF BEAM Q (5) #12x3/4" S.M.S. 3' ANGLE LONG U 1x2 O.B. ATTACHED TO BEAM W/ (TYP. @EACH BEAM) CONNECTION DETAIL Z UAM) W � d (2)-#10X2" S.M.S. INTO SCREW BOSS (2) Y40x3' LG, @ EACH ANGLE (1)-1/4"xN2" S.S. THRU-BOLT J W > / -' ® EA N UT N WASHER M EACH DE OF BEAM ATTTACHEDT Y SCREEN ENCLOSURE BEAMS SHALL BE TO OF CHAIR RAIL/GIRT TO POST U 0 CONVENTIONAL TRUSS/RAFTER FRAMING WITH MAX. #12x2" S.M.S. ® 24" O.C. FACIA TO BE 2x6 (MIN.) S.P.F. OVERHANG NO TO EXCEED 30' UNLESS OTHERWISE CONNECTION DETAIL DRAWN BY: DYK 1x2 O.B. TO SUPER GUTTER OR WESTER RED CEDAR NOTED ON PLAN DWG. CHECKED BY: DYK STRUCTURAL GRADE 2 MIN. 2x3xO.045 EAVERAIL ATTACHED TO BEAMS WITH (3)-#1Ox2" S.M.S. S.M.B. BEAM SCALE: AS SHOWN (4) #12x3/4" S.M.S. (1) Y4 Ox2' -G. LAG SCREW @ 24' INTO SCREW BOSS. i MAY BE SLOPED OR FLAT D.C. ENTIRE LENGTH OF GUTTER 2x PURLIN X (SEE PLAN FOR SIZE) DATE: 8/11/06 (MAY BE SLOPED a a OR FLAT w ROOF BEAM SECURE FASCIA TO EACH RAFTER TAIL ) c� (FLAT OR SLOPED) W/ (1) Ya'Ox4' LONG PAN HEAD LAG SCREWS (2) RAIL S.M.S. THRU. 2x3 BEFORE ATTACHING SUPER GUTTER EAVE RAIL INTO PURLIN SCREW 2x5x.125 ANGLE-2" WIDE WITH w � Bosses (z)-#14x1" INTO BEAM & (2)-#14x1" INTO UPRIGHT. •r Z J ..J f Q USE #100X" S.M.S. 0 24" O.C. — — — TO CONNECT TO 1x2 O.B. TO 2x3. _l�W DO YEON KIM,P.E. (1)-2x2A" ANGLE, EACH SIDE (2 FOR 2x8 SMB OR LARGER.) USE #1041 " S.M.S. 0 24" D.C. 00 FLA.REG.NUMBER 49497 (1) Y415x2' LG, LAG SCREWS _ _ _ _ TO CONNECT TO 1x2 O.B. TO 20. C❑ (TYP. @ EACH BEAM) #12x2' S.M,S @ 12' o.c, 1x2 O.B. FASTENED TO COLUMN/POST PURLIN FASTENED TO COLUMN/POST (4) #12x3/4" S.M.S. (MAX) BETWEEN BEAMS W/(2) #10x11¢" S.M.S. INTO SCREW BOSSES WITH (4) #12x1" S.M.S. (EACH LEG) OF)BEAM 4S.M.S.OR SIDE EACH LEG. (EACH END, TYP.) (TYP.) Ya' MIN„ 3 3�' MAX. C-CERS DO KIM&ASSOCIATES,LLC S{6 THICK CONTINUOUS USING)( THICK FLAT BAR BENT (6) #12x34" S.M.S. EACH SIDE SPACING OF FASTENERS (TYP,) TO FIT (6063-T6 ALLOY) OF BEAM FOR 2x5 COLUMN To CA#26887 5' or 7' SUPER GUTTER ANGLE 2x5 BEAM Y2' MIN. BEAM EDGE PO Box 10039 MIN. 0,090' THICK DISTANCE (TYP.) COLUMN/POST Tampa,FL 33679 COLUMN/POST SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Yi Ox4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER ROOF BEAM TO SUPER GUTTER SIDEWALL POST/COLUMN TO PURLIN MAIN POST/COLUMN TO ROOF BEAM CONNECTION DETAIL ®12' O.C.S.M.S. ADHESSIVE CONTINUOUS BEAD OF CONSTRUCTION CONNECTION DETAIL CONNECTION DETAIL Drawing No. -060811 SHEET 1 OF 3 PURLIN SUPPORT COLUMN/POST Yg" ANGLE, EACH SIDE (TYP.) S.M.S. WITH MIN. 3/8" 3A"O CONCRETE ANCHOR BEAM � ANGLE ( LONG) (TEKS INTO TOP OF 2 3EAVE RAIL I AND (2)- W (4)8" x 2" LG. ANGLE EDGE DISTANCE 3•• #14 TEKS INTO THE FRONT OF THE CORNER POST (EACHH SIDE) STRUCTURAL CONCRETE (TYP.,#12x3/4" S.M.S EMBEDMENT INTO /// D ❑ K I M (EACH EE NOTE 10) & ASSOCIATES, LLC O O %"0 CONCRETE ANCHOR 1"x2" O.B. SOLE PLATE O O W/2%" EMBEDMENT INTO 2"x PURLIN STRUCTURAL CONCRETE CONSULTING (EACH SIDE) I 1x2 O.B. TOP FRAME STRUCTURAL a a z ENGINEERS NE °'' �'° ^ y •t � 2x2 ANGLE CLIP, CUT AT 1x3 O.B. FASTENED TO CORNER .� 5' CORNER POST .`A':� A 45' (+/-) ANGLE AND SECTION WITH #10x2" S.M.S. W/ 3" MIN. (TYP.) a w BEAM MAY ATTACHEBEAM WITH TO THE (1)SCREEN THROOF �" DIA. WASHER ® 18" O.C. PO BOX 10039 Y4"0x2Yq" CONCRETE BE FLAT ix O.B. SIDE WALL CORNER UPRIGHT z W BOLT, WITH FENDER WASHER. Tam a,FL 33679 SCREW ANCHOR ® 24" O.C. OR SLOPED P E j z ATTACHED TO BEAM OR L N RAIL. Tel: 813 374-0321 ago AND 9" FROM POST (TYP.) O DIAGONAL BRACING SHALL NOT BE ( ) N� I ATTACHED TO ROOF PURLINS. 2x2xO.093 BRACE P SIDEWALL COLUMN TO CONCRETE 9• COLUMN/POST ELEVATION VIEW Rev./Date Description (SEE PLAN) CONNECTION DETAIL 0 Zo,s ISSUED 1x2 O.B. SOLE PLATE CORNER POST/COLUMN PLAN - TYPICAL DIAGONAL ROOF � BRACE CONNECTION UPRIGHT DETAIL 0 0 SEE PLAN FOR SIZE EDGE of CONCRETE I' (TYP.) 2500 PSI MIN. CONCRETE STRENGTH 1x2 O.B. FASTENED TO CORNER ti£ COLUMN d d SECTION WITH #14x1Yz" S.M.S.® za" O.C. APPROXIMATE qN PLAN VIEW wwa a III— w z SET IN MORTAR ON TOP OFFOOTER GRAD ' III—I 2x24" ANGLE 2" LONG (EACH SIDE) IE W/(2) #14x3/4" S.M.S. TO POST z ti� Z -I I I I I c. d d ° I I III l & 3/8"0 H.D. GALV. EXP. BOLT + u ca£ SCREEN 0.6, SOLE PLATE _ W/ 2 1/2" MIN. EMBEDMENT I—I I a —I I I- CID�)I1IIII A IIIIIII�COMPACTED OR _ � _III d I I=I UNDISTURBED SOIL/SAND w CORNER POST/COLUMN I—I I _ (1)—#5 REBAR, CONTINUOUS c •;' —III III—I I 3" MIN. CONC. COVER, 36" MIN. LU TO CONCRETE r ;. .. , . _ II—II -III—II I—III—II =III= LAP SPLICE o CONNECTION DETAIL ° cn...° i fii � O 3 12" MIN.* 0Yq" Ox5" CONCRETE SCREWS ® 24' O.C. 2/8" MIN. CONC. BEAM SUPPORT T1• EMBEDMENT (TYP.) U z 3 Jg" ANGLE, EACH SIDE (TYP.) COLUMN/POST (TYP.), 1Y2•• CONC. EMBEDMENT (MIN.) LL1 S.M.S. WITH MIN. /g" EDGE DISTANCE %"0 CONCRETE ANCHOR L z W/2%' EMBEDMENT INTO W/ (4)8" x 7" LG. ANGLE (D iii STRUCTURAL CONCRETE (TYP., W/ (4) #12x3/4" S.M.S TYPCIAL FRONT VIEW OF POST TO MIN. CONTINUOUS PERIMETER FOOTING m LLI SEE NOTE 10) (EACH SIDE) 0 Z C) (\1i` 1"x2" O.B. SOLE PLATE FOUNDATION CONNECTION WITH PAVERS �_ p �U O O O _I O O \ , Q a N-6 I Q BEAM V ALTERNATE (1) J LLI > POST U Q ...° 2x1x%" ANGLE 3" MIN. (TYP.) (4) #120/4"" S.M. BRACE DRAWN BY: DYK z Y4"OxA4"" CONCRETE £ w SCREW ANCHOR ® 24" O.C. 4" NOMINAL CONCRETE SLAB 2"x PURLIN 2"x1"A"" ANGLE (BRACE) W/ CHECKED BY: DYK uu AND 9" FROM POST (TYP.) (2500 PSI, MIN.) W/6x6x10/10 z (4) #120/4" S.M.S. ® EACH SCALE: AS SHOWN `a o W.W.M. OR FIBER REINFORCED ti POLYPROPYLENE FIBER - MEMBER INTERSECTION [ O DATE: 8/11/06 1.5 POUND (MIN.)PER C.Y.1 O COLUMN/POST z z O 2x2xYe"' ANGLE 2" LONG ON UNDERSIDEW/(4) #12x3/4"" S.M.S. 1x2 O.B. SOLE PLATE ° - d •a BEAM MAY EACH LEG (BEAM & BRACE) ® ® a.. .� BE FLAT e. ,a ° °d.. ° OR SLOPED °d, °� c d ((2) #1)x2Y2" S.M.S. °__ DO YEON KIM,P.E. ® a d^ ° A (TYP. EACH END) 2x3 BRACE FLA.REG.NUMBER 49497 v III III III III ` _ ((2 a d (TYP#1EA H2 END)S (SEE PLAN) ° a ALTERNATE (2) ° DO KIM&ASSOCIATES,LLC 1' (TYP,) � III—III III—III a d ° .a°: < � 2x3 BRACE PO Box10039 EDGE OF CONCRETE N z —I 11—I 11 11 I—I I '' E .a UNDISTURBED SOIL OR COMPACTED Tampa,FL 33679 CRUSHED LIMEROCK (90% PROCTOR) PLAN VIEW MIN. (1)-#5 REBAR CONTINUOUS, SPLICE MUST OVERLAP 20" MIN. PLAN - TYPICAL ROOF MAIN COLUMN TO CONCRETE B'(NIN.) 3" COVER (TYP.) BRACE TO BEAM CONNECTION 1 CONNECTION DETAIL FOUNDATION/SLAB DETAIL Drawing No. -060811 SHEET 2 OF 3 #10x4' S.M,S. W/ IWO FENDER WASHER 5' STRUCTURAL AND NEOPRENE GASKET @ 12' O.C. (5) #120/4" S.M.S. SUPERGUTTER lx5xYB' ANGLE 6' LONG #10x3/." S.M.S. W/3/a" 0 (TYP. @ EACH BEAM) lx5xYo' ANGLE 4' (4)-#14x2Y2' S.S. LAG SCREWS WASHER AND INTEGRAL NEOPRENE (2) 1/q'Ox3' LG. @ EACH ANGLE LONG - TYP. W/IY4'0 WASHERS INTD HOST D Q KIM GASKET ® 12" O.C. (TYP. T&B) STRUCTURE, 2' MIN. EMBEDMENT (8) #140/4" S.M.S., (4) SCREWS 3' COMPOSITE (4) #14xi' S.M.S. THRU & ASS❑C I ATE S, L L C EACH LEG - (16) TOTAL ROOF PANEL ANGLE INTO GUTTER (TYP. EACH SIDE OF BEAM) SLOPE 1/4'/1' (MIN,) TYP. EXISTING FACIA TO BE 2x6 (MIN,) S.P.F. STRUCTURE C❑N S U LT I N G (CEDAR IS NOT ACCEPTABLE), �' HEAVY U-CHANNEL STRUCTURAL O O V C)U O v O v C)v O ''O"O"O O 0 C.l STRUCTURAL GRADE 2 MIN. W/(6) #12x%' S.M.S. EACH LEG ENGINEERS O O O O O O O O O O O O C S.M.B. BEAM 0o000000000 O O O O O AND WEB INTO S.G.) _--- D O O O O O O C 5" STRUCTURAL O,�O O n O n O O O -)O O O O OO^O O O^-Ono C SECURE FASCIA TO EACH RAFTER TAIL BEAM STITCHING SCREW @ 24' O.C. SUPERGUTTER & WITHIN 3' FROM ENDS SEE TABLE W/(1) 3'a'Ox3 1/2' LONG PAN HEAD LAG SCREWS FOR SIZE (TYP. TOP AND BOTTOM,) PO Box 10039 BEFORE ATTACHING SUPER GUTTER Tampa,FL 33679 Tel:(813)374-0321 (2) 2x24" ANGLES V 2x__ S.M.B. V Rev./Date Description (TYP. EACH SIDE OF BEAM) S.M.S. INTO MIN. PLATE W/ (3) #14(TYP.) (SEE PLAN FOR SIZE) S.M.S. INTO BEAM AND COLUMN (TYP.) PLAN 9016 ISSUED 219 (2)-%"0 BOLTS W/ 1}" WASHER SUPER GUTTER (TYP. ® EACH BEAM) 0 SEE BEAM TO SUPER BEAM TO SUPER GUTTER CORNER CONNECTION GUTTER FOR DETAILS 3"x3"xO.093" MIN. COLUMN (TYP.) SCREEN ROOF TO COMPOSITE ROOF 0 CONNECTION DETAIL SEE PLAN FOR POST SIZE__ General Notes and Specifications: (6) #14x3/4' S.M.S. TOTAL, (3) EACH LEG \\\ 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate U) MIN. C-C SPACING (TYP.) } J consideration. BASE INSERT W/1Y2' VERTICAL LEGS W v _ ' THICK 6063-T6 ALLOY (TYP,) A¢ IL 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be In accordance with the requirements of ACI 318. dLU HOT DIPPEDAGALVAN ZED STEELINLESS DR w� t Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. C: W CONC. ANCHORS W/ 2 J' MIN, aC'ca (SEE EMBEDMENT NOTE INTO CONCRETE. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 0 TOP OF CONCRETE ;, .; �..�•.... .,. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The C O0 / ..., 9 9 q °• "•a'' / contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If Z 'a '.• there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host v W / structure capacity. (D W 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 3005-T53 Alloy, 6005-T5 Alloy; for secondary c Z W SCREEN ROOF TO PANEL/ COMPOSITE components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. ..2 O 0 COLUMN TO FOUNDATION 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 1- Q CONNECTION DETAIL Z V U 3. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. W U) d J W }- 8. Unless otherwise shown, screws shall have minimum edge distance and center-to-center distances as shown in this table. IJ Q F— C-1022 Low Carbon Steel SMS & Self-Drilling (TEK) Screws (Industry Standard Screws) DRAWN BY: DYK Nominal Screw Diameter Minimum Center to Center CHECKED BY: DYK #10x4" S M.S, W/ IS'a'O FENDER WASHER (In) Minimum Edge Distance Distance SCALE: AS SHOWN AND NEOPRENE GASKET @ 12' O.C. Screw DATE: 8/11/06 3' COMPOSITE #10 0.188 5/16" ''/2" ROOF PANELS #12 0.219 3/8 " 9/16" 0000 O'O'O'O'O'O'O� #14 (1/4") 0.250 1/2.. s/e„ 0 0 0 0 0 0 0 0 0 `D000 00000000000000 DOYEON KIM,P.E. FLA.REG.NUMBER 49497 WIDTHNMAX, 9. Structure has been designed to meet the 611 Edition FBC (2013 FBC). Project is sited where the ultimate design wind speed, Vult PATIO SIDE WALL HEADER is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, (SEE PLAN FOR SIZE) 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASD). DO KIM&ASSOCIATES,LLC (4) #10x2" S.M.S. THRU. UPRI CA#26887 INTO EAVE RAIL/HEADER SCREW 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong-Tie Anchors or Titian Screws PO Box10039 BOSSES Tampa,FL 33679 or approved equal. COMPOSITE ROOF TO HOLLOW SIDE WALL 11. Aluminum roof pans shall be of aluminum alloy 3105-H14 or 3105-H28. Composite panel skins shall be of aluminum alloy 3105-H15 HEADER CONNECTION DETAIL or 3105-H25. 12. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.13.1.11. if enclosing a pool. Drawing No. -060811 SHEET 3 OF 3