Loading...
HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITAp p l i c a n t : 5/1/2020 Pr o d u c t Op e n i n g D e s i g n Pr e s s u r e s Pr o d u c t R a t e d D e s i g n Pr e s s u r e Ma n u f a c t u r e r M o d e l N u m b e r P r o d u c t A p p r o v a l Nu m b e r Gl a s s Ty p e Wi n d o w s Se e A t t a c h e d + 8 0 / - 8 0 PG T I n d u s t r i e s 7 7 2 0 A S e r i e s N O A # 1 8 - 0 4 3 0 . 0 5 I m p a c t Mu l l i o n s Fi x e d G l a s s Se e A t t a c h e d + 8 0 / - 8 0 PG T I n d u s t r i e s 7 7 2 0 A S e r i e s N O A # 1 8 - 0 4 3 0 . 0 5 I m p a c t Bl o c k G l a s s Sk y l i g h t s Sl i d i n g G l a s s D o o r s Sw i n g T y p e D o o r s +5 3 . 1 / - 5 7 . 8 + 7 5 / - 7 5 Me s k e r D o o r N S e r i e s 1 5 5 4 2 . 2 Im p a c t Sw i n g T y p e D o o r s El e v a t o r M a c h i n e R o o m +5 3 . 2 / - 6 9 . 6 + 7 5 / - 7 5 St e e l c r a f t H S e r i e s 1 2 4 0 0 . 3 Fr e n c h D o o r s Ga r a g e D o o r s +4 6 . 8 / - 5 2 . 7 + 6 5 / - 6 5 Ov e r h e a d D o o r 6 2 5 S e r i e s N O A # 1 8 - 1 2 1 7 . 0 5 Hu r r i c a n e P r o t e c t i o n Se e A t t a c h e d + 8 0 / - 8 0 PG T I n d u s t r i e s 7 7 2 0 A S e r i e s N O A # 1 8 - 0 4 3 0 . 0 5 I m p a c t Ro o f V e n t i l a t i o n Ro o f i n g M a t e r i a l +3 2 . 1 0 / - 1 3 1 . 3 0 Va r i e s , p l e a s e s e e at t a c h e d p r o d u c t ap p r o v a l Ki r b y B u i l d i n g Sy s t e m s St a n d i n g S e a m 3 6 0 2 6 0 5 1 . 1 In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d I h a v e r e v i e w e d t h e a b o v e c o m p o n e n t s o r c l a d d i n g a n d I h a v e a p p r o v e d t h e i r u s e i n t h i s s t r u c t u r e . T h e s e p r o d u c t s p r o v i d e a d e q u a t e r e s i s t a n c e t o t h e w i n d l o a d s a n d f o r c e s sp e c i f i e d b y c u r r e n t c o d e p r o v i s i o n s . Na m e : S i g n a t u r e : s e a l D e s i g n P r o f : C e r t . N o . D a t e : In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d Pl a n n i n g & D e v e l o p m e n t S e r v i c e s D e p a r t m e n t B u i l d i n g & R e g u l a t i o n s D i v i s i o n Pr o d u c t R e v i e w A f f i d a v i t In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d Bu i l d i n g P e r m i t # Ow n e r s N a m e Fl o r i d a P o w e r & L i g h t C o Cu r i n g t o n C o n t r a c t i n g , L L C Me t h o d o f A t t a c h m e n t In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d In s t a l l a t i o n I n s t r u c t i o n s a r e A t t a c h e d H a r o l d W . B a r r i n e a u , P . E . 49 4 4 7 -59.0 psf -59.0 psf -59.0 psf -59.0 psf 6 7 -57.8 psf -57.5 psf 48.5 ft. 56.9 ft. 20.5 ft. 34.5 ft. +54.3 psf, 4.0 ft. 4.0 ft. +52.7 psf, +53.1 psf, 4.0 ft. 4.0 ft. Distance from Corner (in ft.) Opening Height (in ft.) Opening Width (in ft.)DescriptionNo. Design Pressure Requirements 1 2 3 Window B Shop Window B Office 5 Window B Office 6 4 +52.8 psf, 4.0 ft. 7.0 ft. 7.0 ft. 4.0 ft. -57.7 psf 5 -59.0 psf -57.5 psf -56.2 psf -69.6 psf -57.5 psf -57.5 psf -52.7 psf 4.0 ft. 4.0 ft. 4.0 ft. 4.0 ft. 3.5 ft. 3.0 ft. 6.0 ft. 6.0 ft. 6.0 ft. 6.0 ft. 6.0 ft. 6.0 ft. 4.0 ft. 4.0 ft. 4.0 ft. 4.0 ft. Window B Office 7 Door 3670 Half Light Doors double 3070 H.L. Window A Conf. Room 4.0 ft. 4.0 ft. -59.0 psf -59.0 psf -59.0 psf 10.5 ft. 26.5 ft. 37.5 ft. +54.3 psf, +54.3 psf, +54.3 psf, +54.3 psf, +54.3 psf, 4.0 ft. 8.8 ft. 13.5 ft. -59.0 psf +54.3 psf, +54.3 psf, 4.0 ft. 4.0 ft. 4.0 ft. 6.7 ft. 4.0 ft. +54.3 psf, +52.7 psf, +52.7 psf, +46.8 psf, +51.5 psf, +53.2 psf, 4.0 ft. 4.0 ft. 4.0 ft. 4.0 ft. 4.0 ft. -57.5 psf 13 14 15 16 Window B Eng. Office Window B Eng. Office 60.5 ft. 51.5 ft. 4.0 ft. -61.4 psf 10 11 12 Window A Conf. Room Window A Conf. Room Window A Conf. Room 8.5 ft. 6.5 ft. 16.8 ft. 27.8 ft. 38.8 ft. +52.8 psf, +52.8 psf, +52.8 psf, +52.8 psf, +52.8 psf, 8 9 Window A Conf. Room Window A Conf. Room -57.5 psf -57.5 psf 23 Window B Office 4 Window B Office 3 Window B Office 2 Window B Office 1 40.6 ft. 28.5 ft. Door 3670 H.L. Door 3670 H.L. 3.5 ft. 3.5 ft. 7.0 ft. 7.0 ft. 40.6 ft. 18.8 ft. 17 18 6.5 ft. -62.4 psf 17.5 ft. 20 +54.3 psf, 3.0 ft.Door Motor Room 3068 19 The site of this building is not subject to special topographic wind effects. The Ultimate Wind Speed was used to determine the above Component and Cladding Design Pressures. All exterior glazed openings shall be protected from wind-borne debris. Ultimate Wind Speed: 160 mph CWind Exposure: 21 22 12x12 O.H.G.D. Elevator Door To Deck 12.0 ft. 4.8 ft. 12.0 ft. 7.3 ft.