HomeMy WebLinkAboutEnergy CodeBRADEN 6 BRADEN, A. I. A., P. A.
-Wrchaecls & 'Planners
417 COCONUT AVENUE, STUART,, FLORIDA 34996
TELEPHONE: (772) 227-225B FAX (772) 287-32B3
#AAGOOOD32
WYNNE DEVELOPMENT
PERMIT
ADDRESS:
To whom 1t may concern. 1
Please note this 1s the tgplcal footing for
this project in lieu of what 1s shown on the
plans. If you have an qquestions please feel
free to call me 772 U1-8258.
51n e
B(eQAIA
Brade t Br e� PA
® M
MOOM
®®
0n-00
CEO
40
-< m
#5 bar vert. w/
30" overlap —
at each filled cell
11
3-12-20
F111 cell with concrete and
(l) #5 bar vert. (tgplcal).
Max. spacing shall not exceed
Wood .48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with flbermesh OR
CA" #10/10 WWM on 6 m11 V(squeen over
clean compacted termite treated fill
4:PTii 11—ii-iii
14"w x 18"d Concrete footing
with (2) #5 bars cont. and 45
transverse bars at 48" o.c.
TYFCIAL FOOTING DETAIL
nts
BBraden & Braden, AIA, PA
A4 Ina g"r#AAC000032
417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258
St. Lucie County Budding Dept.
Wgnne Development
Date:
Address:
Permit #: `�Nj lk—
To whom it mag concern.
This detail applies to the insulation it
the ends of the vaulted ceilings.
If you have any questions please feel
free to call me at -112-287-8258
R-19
ZWBraden
AIA .
Braden E Braden AIA PA
s
Trusses at 2,4" o.c.
>e shop drawings bg others
ceiling transition 6'�
-ded using metal studs
,erify exact configuration
.as
O
W�
�z
Q
®a0
-�
ww
®
C)
Wed
�6�
R—SO Batts
19 baits
Drywall ceding
see typical section
Gelling transition Insulation Detail
nts
3.�
G)
�
d
N
m
p
y
Z
[If
Il
I
y
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
Florida Department of Business and Professional Regulation - Residential
1�
CONSTIQN
PerformafiflAd
Project Name: WYNNE THE WINDSOR IMP CT
^�``
Builder Name: WYNNE DEVELOPMENT
Street: �11�'�g'1�
�
Permit Office: ST. LUCM COUNTY
City, Slate, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucle (Florida Climate Zone 2 )
1. New construction or existing New(From.Plans)
9. Wall Types(1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft'
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4.. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (11) 1753
b. Knee. Wall (Vented)
R=19.0 30.0o ft2
Conditioned floor area below grade (ft) 0
c. NfA
R= ft
11. Ducts
R ft'
7. Wmdows(151.4 sgft.) Description Area
a: Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=1.04 111.36 ft'
SHGC: SHGC=0.29
b. U-Factor. Slit, U=1.11 40.00 ft2
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:P
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8, HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC:,, 0.285
14. Hot water systems
8. Floor Types (1763.0 sqft.) •, Insulation Area
a. Electric
Cap: 40,galions
a. Slab -On -Grade Edge Insulation •' R=U.O 1753:00 k2
b. Conservation features
EF: 0.970
b. NIA "R= ft2
None
c. NIA R= ft2
15. Credits
Pstet
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20
PASS
Total Baseline Loads' 53.92
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
O�SiiEsig
Code.
calculation indicates compliance
with the Florida Energy Code.
����/']
PREPARED BY: x�w� 4/
Before construction is completed
a
DATE: 1-9-2d
this building will be inspected for
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.-_.��+'OD
{S
OWNER/AQ�t�:
BUILDING OFFICIAL:
DATE: a
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403:3.2.4.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
1/812020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
I/
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
'PROJECT
- Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User Conditioned Area: 1753
Lot#
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: 'No
City, State,
Zip:
FT. PIERCE,
• Family Type: Single-family
FL,
New/E)dsting: New (From Plans)
Comment:
CLIMATE
_ / Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH! MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1753 14024
SPACES
Number Name Area Volume Kitchen Occupants'
Bedrooms
Infi11D
Finished Cooled
Heated
1 MASTER BEDROO 224 1792 No 0
1
1
Yes-
Yes
Yes
2 WIC 63 504 No 0
1
No
Yes
Yes
3 MASTER BATH 56 448 No 0
1
Yes
Yes
Yes
4 M. BATH 61 488 No 0
1
Yes,
Yes
Yes
5 LAUDRY 36 288 No 0
1
No
Yes
Yes
6 BEDROOM 2 180 1440 No 0
1
1
Yes
Yes
Yes
7 DINING/GREATR 588 4704 No 2
1
Yes
Yes
Yes
8 KITCHEN 209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH 50 400 No 0
1
Yes
Yes
Yes
10 HALL 25 200 No 0
1
No
Yes
Yes
11 FOYER 92 736 No 0
1
Yes
Yes
Yes
12 BEDROOM 3 169 1352 No 0
1
1
Yes
Yes
Yes'
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDR0 37 ft, 0
224 ft'
0 1
0
2Slab-On-Grade Edge Insulatio WIC i 1 it 0
63 ft'
—
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ft'
____
0 1
0
4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0
61 ft'
—
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY l it 0
36 ft'
____
0 1
0
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6SIab-On-Grade Edge hisulalio
BEDROOM 2 12 ft
0
180 ft2
_
0 1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588ft2
0 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft'
_
0 1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft'
0 1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft'
____
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft'
0 1
0
ROOF
_ /
Roof
Gable
Roof
Red
Solar
SA 'Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
_ 1 Hip
Metal 1847 ft2
0 ft2
Light
N
OA
No 0.9
No 0
18.4
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 In)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Free Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft'
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
_ 4 Under Attic (Vented)
M. BATH
3D
Blown
61 ft'
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 112
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
688 ft2
0.1
Wood
_ 8 Under Attic (Vented)
KITCHEN
30
Blown
209 112
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 fit
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DININGIGREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing'Framing Solar
Below
1 E Exterior Concrete Block - Int InsWASTER BE 4.1 16
0 8
0
128.0 ft2
0
0 0.3
0
—2 W Exterior Concrete Block- Int InsNASTERBE 4.1 7
0 8
0
56.0 ft2
0
0 0.3
0
_ 3 S Exterior Concrete Block- Int InstMASTER BE 4.1 14
0 8
0
112.0 ft'
0
0 ' 0.3
0
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02. (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARYCHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar
Below
-4
E
Exterior
Concrete Block - Int Ins01ASTER BA
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
-5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.3
0
-6
E
Exterior
Concrete Block- Int InsE3EDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.3
0
_ 7
S
Exterior
Concrete Block- Int Ins(DININGIGRE
4.1 30
0
8 0
240.0 ft'
0
0
0.3
0
-8
W
Exterior
Concrete Block- Int Ins6NINGIGRE
4.1 20
0
8 0
160.0 ft'
0
0
0.3
0
_ 9
W
Exterior
Concrete Block- Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
_ 10
E
Exterior
Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
_ 11
N
Exterior
Concrete Block - Int Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
12
N
Exterior
Concrete Block - Int Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
13
W
Exterior
Concrete Block - Int Ins®EDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.3
0
_ 14
N
Exterior
Concrete Block - Int Ins®EDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
15
N
Garage
Frame -Wood BEDROOM
11 26
8
208.0 ft'
0.23
0.3
0
DOORS
#
Orrd
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
_
1
S 3
Metal Low-E Single Yes
1.04 0.29
N
32A ft'
1 it 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft'
1 it 0 in
1 ft 5 in
None
None
_
3
E 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft'
1 It 0 in
1 ft 5 in
None
None
_
4
S 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 ft
1 It 0 in
1 ft 51n
None
None
5
W 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 V
8 It 0 In
1 ft 5 in
None
None
6
W 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft'
1 ft 0 in
1 ft 51n
Drapes/blinds
Exterior 5
GARAGE
#
FloorArea Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft' 806 ft'
26It
8 It
11
INFILTRATION
#
Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Whole house Proposed ACH(50) .000254 1168.7 64.16
120.66
.0881
5
1/812020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software • Page 4 of 6
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5
34.8 kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
-
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
— Supply—
— Return
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 175 ft'
Attic
55 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Progremablre'Thermostarxt: Y
Gelling Fans:
HeDec
ating Jan Feb
rx]'�
Mar
[ ]
L J
[X
Jun [ Jul
[X
[ Aug
[X
[ Sep
[ ]
1.1
r[)(')
Venting [) Jan (1 Feb
l l l l
lXl Mar
lAl
lxl r [
May Jun [ Jul
[ Aug
[ Sep
lxl t
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
8
10
11
12
Coaling (WD)
80
80 78
78
PM
78 78
78
78
78
78
78
78
Cooling ((NEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (IND) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68'
68
68
68
66
66 .
MASS
Mass Type
Area
Thickness Furniture Fraction
Space•
Default(8 lbs/sq.ft.
0 ft'
Oft
0.3
BEDROOM
Defauit(B Ibs/scift
ft'
ft
0.3
WIC
Default(8 lbs/sq.fL
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.fL
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(B Ibs/sq.fL
ft'
ft
0.3
BEDROOM 2
Default(8 [bs/sq.fL
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8lbs/s .ft. ft. ft . 0.3 GREAT/DINING
118/2020 4:43 PM EnergyGauge®-USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
'2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
V
Owner. Jurisdiction:
_
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceilinglsoffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed In substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfioor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvenled crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation.
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninona and wirino
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectricaUphone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxesor air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
J
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between M iii2dakler Cover plates and walls or ceilings, I
a. ui auuumu, nwpmiiun ui my wars snap ou In accomanue win me provisions or IGG-4uu.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more' efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic,
3. No, of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.6
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unitIPTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
81b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a)Under atic
11a.
30.0
b).Cross ventilation .
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home:��.�4 Y' ,\ c� Ok� G1 City/FL Zip: FT. PIERCE. FL ��ct
1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1