Loading...
HomeMy WebLinkAboutEnergy Code00 a FORM R405-2017 F�� melt I<! r :ORIDA ENERGY EFFICIENCY CODE F eae � � �`�`�TLDING CONSTRUCTION e �y Florida Department of Business and Professional Regulation - Residential Performance Method a Project Name: Lot 22 Block 77-9 IndianRiverEstate 2010 AGR Builder Name: ADAMS HOMES Street: 5611 Spruce Drive Permit Office: City, State, Zip: Fort Pierce , FL, 34982 Permit Number. Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1472.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1308.00 ft2 b. Frame - Wood, Adjacent R=13.0 164.00 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2010.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2010.00 ft2 6. Conditioned floor area above grade (112) 2010 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(198.3 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 402 a. U-Factor: Dbl, U=0.33 101.82 ft2 SHGC: SHGC=0.23 b. U-Factor: Dial, U=0.33 78.75 112 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 5.229 ft. Area Weighted Average SHGC: 0.264 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2010.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2010.00 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 15. Credits Pstat Total Proposed Modified Loa s: 57.99 Glas/Floor Area: 0.099 PASS Total Baseline Load : 59.89 i I hereby certify that ithe plans and specifications covered by Review of the planqI and 04 f1iB STgrB this calculation are in compliance 2 Florida E specifications coveted by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed c O DATE: 1-31-7n9n Winn Kanmany this building will be inspected for compliance with Section 553.908 Z *. I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Fnergy Code '0 OWNER/AGE; k ; /�-�- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). BILE C()31 1/31/2020 9:13 AM EnergyGaugeB USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software page i 0f4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT idtle: Building Type: Owner Name: - # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Exisfing: Comment: Lot 22 Block 77-9 IndianRiver Bedrooms: 3 User Conditioned Area: 2010 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 22 Block/Subdivision: IndianRiverEst. PlatBook: Street: 5611 Spruce Drive County: St. Lucie City, State, Zip: Fort Pierce, FL, 34982 CLIMATE / V Design Location Design Temp TMY Site 97.6 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2010 17286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2010 17286 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 163.4 It 0 2010 W ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emill Emitt Decl� Pitch Barr Absor. Tested Tested Insult (deg) 1 Gable or Shed Composition shingles 2248 ft' 504 ft' Medium 1 N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Vented 300 2010 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2010 ft' 0.11 Wood 1/31/2020 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT WALLS Adjacent Space Cavity Width P Height Sheathing Framing Solar Below o 1 S Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 ft2 0 0 0.6 0 .-2 E Exterior Concrete Block - Int Insul Main 4.1 21 6 8 0 172.0 ft- 0 0 0.6 0 _ 3 N Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 56 0 8 0 448.0 ft2 0 0 0.6 0 _ 5 - Garage Frame - Wood Main 13 20 6 8 0 164.0 ft2 0 0.23 0.01 0 6 E Exterior Concrete Block - Int Insul Main 4.1 14 0 8 0 112.0 ft2 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 4.7 ft2 1 ft 4 in 0 ft 11 in None Exterior 5 2 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 112 1 ft 4 in 0 ft 11 in None Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 46.4 ft2 7 It 0 in 0 ft 11 in None Exterior 5 4 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 11 in None Exterior 5 5 W 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 6 in 1 It 0 in None None 6 W 4 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 11 in None Exterior 5 7 W 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 6 in 0 ft l l in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 425 ft2 425 R2 64 ft 8 it INFILTRATION # Scope Method SLA CFM �0 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000383 2016.7 110.71 208.21 .1364 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/31/2020 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPIIT SI IMMARV ICT ocono-r COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unil/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply— V —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 402 ft' Main 100.5 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablre,Thermostat: Ceiling Fans: ,]Y Heating Jan Feb Venting Mar Apr € 00 �( May Jun [ ] Jul [ Aug �X [ j j Sep L J 0 t H H 11 Jan 11 Feb l l l l X Mar Jun 11 Jul I Aug I Sep lxlOct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 8 � 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 6 66 66 66 66 68 68 68 168 68 68 68 PM 8 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Are Thickness Furniture Fraction Space Default(8 lbs/so.ft. 0 W 0 ft 0.3 Main 1I3U2020 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2010 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.264 c) Area 7c. 198.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior: 1. Wood f me (Insulation R-value) 10A1. 2. Masonr (Insulation R-value) 10A2. 4.1 B. Adjacent: 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10B2. I 11. Ceiling type and insulation level a) Under attic 11 a. 30.0 b) Single assembly 11b. c) Knee walls/skylight walls 11c. d) Radiant barrier installed 11d. No 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 34.6 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedi+ted heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other J 1 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatur � Date: Address of New Home: 5611 Spruce Drive City/FL Zip: Fort Pierce, FL 34982 1/31/2020 9:13:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1