HomeMy WebLinkAboutBuilding Plans5/8" thick light textured
stucco on typical concrete
block construction
L
RIGH
12
4 SLOPE
l�
SEARING
.H.
T
R
R
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
L ga. 5v crimp metal roofing attached to plgwood deck using #9
wood screws with self sealing washer at 12' o.c. max spacing over
(tgpe 2) 30 lb Pelt underlagment installed with min. 4 side laps
laps fastened with corrosion resistant tin caps and with 1.2V ring
aced L o.c. at all laps and two staggered rows 12 o.c. fie
eck to trusses using attachment detai on this sheet
SCALE: 1/4' - 1'-0'
0
r
e
5/8" thick x 8"w cut
coral finished stucco bands
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11451.12
2L ga. 5v crimp metal roofing attached to plgwood deck using #9 x L5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
ftgpe 2) 30 lb felt underlagment installed with min. 4 side tape and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?paced L" o.c. at all laps and two stagggered rows 12" o.c, in field. Attach
deck to trusses using attachment detail on this sheet
0'-0" = Finished Floor
_-__--- -_____---
5/8" thick light textured
stucco on typical concrete
block construction
LEFT ELEVATION
SCALE: 1/4" - 1'-0'
12
SLOPE 4
COVERED
PORCH
Finish Columns with /
5/8" thick cut coral
finished stucco bands
gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
L ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(tgpe 2) 30 lb Pelt underlagment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all tape and two stagggered rows 12 o.c. in field. Attach
deck to trusses using attachment detal on this sheet
stucco on typical concrete 5/8" thick x 8"w cut
block construction coral finished stucco bands
REAR ELEVATION
SCALE: 1/4' - 1'-0'
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #IIL51.12
2L go. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
Wood screws with self sealing washer at 12' c.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shack nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
\ ��_ in be 19/d of CDX Plg0d nailed shank
at L" o.c.
'/,/ infield and edges with IOd ring shank galvanized
nails into truss webbing.
ICI
ICI ICI
ICI
®�
ICI'
ICI
ICI
ICI
r�l
ICI ICI
ICI
•
' �
ICI
ICI
ICI
ICI
ICI
ICI
I[_ I
ICI
"
ICI
Ita
Im
Ial
5/8"
thick x
8"w cut
coral
finished
stucco bands
FRONT
ELEVATION
1I ' 1/2' d"'"1r"A ceiling on trues bottom cord
2" x 4" top plate
I/2" drywall on
x 4" studs at lb" o.c.
base —board 11 11 , 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
L"xL' #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
nterlor Non -Bearing Partition
nts
kmraquamln
It
Irfl .aR AWk; ,A
Wynne
Building
Corp.
Architects — Planners
5.. Coconut AvenueTelel
THE
W I N D S O R
(„2) 28,-8258
Fax
E-mail.
(112) 281-8283
bradenaiamcomcast.net
Spanish Lakes
S . Lucie County Florida
SCALE: 1/4' - 1'-0'
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION
(FORM 100)
t
t
Florida Building Code Residential: Lth Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categoryy.� II Wind Velocitg: I0 mph ultimate
Mean Root Height: IIII'—OO• Root Pitch: 4.12
t`
E
Internal Pressure merit: tole
Sub,lectabilitg to damage from: Weathering: Nealisiible Termrtes: Vera Heava
l
Width of Roof End Zone: 3'-4• Wind Speed: IL5 mph ultimate
MWind Exposure Classification: C
1.21 x O.L = 0.12E
Adjustment factor for Exposure Height: A3D design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.L L+O1WL
Components ! Cladding Wind Pressure (NET) Roof Zone. I. +20.1p/-32.6 pat
Roof Zone: 2. +20.L/-51.0 pal
Root Zone: 3. +20.L/-84.0 pat
Components t Cladding Wall End Zone Width: 3,_4'
Components I. Cladding Wind Pressure (NET) WWell 5.+35.8/-41.8 pat
®Wall& Z Zone 4
Zcner:
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 pat
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
tit = Roof Zone 2
YYeeaa
Wall& Zone 5
Are Components an Cladding Dew Provided? Yes
END ZONE
Minimum Sal Bearing Pressure: si, Presumptive: X B0 est: psi
er
®� CornZones
S DUC AP R VAL F RIM A T P O E TION F R O E IN 5
ERO
Roof Zone 3
ROOF LIVE LOAD: 31 pet ROOF DEAD LOAD: 10 pat
FLOOR LIVE LOAD: —A5— pat FLOOR DEAD LOAD:_ al
p,
JOB ADDRESS
Model: Date Drawn Revisions : Sheet Comm #
REAR Z-28-18 5 -23-F ir A
C.Gd
PORCH =raven bg e 1 . 15—I59
.U.
RIGHT " i-.hecked bg: � CODE COMPLIANCE impact
rD.R.B. _qT. LUCIE COUNTY r 5
'FLOOR PLAN Recat top plate L"w x 3/8"d
4" for steel support angle \
CRASH POST DETAIL 8ee detail on this sheet
TYPICAL NOTES: SCALE 1/4" = 1'-O" NTS
1. Contractor to verify ALL notes and dimensions prior to 3C high by 4" diameter
roeeedln With work steel crash post. Floor Steel countertop support angle
Counter top - verify type
with contractor
p g Flange with 4 - 3/8 install Lfrom each end and J Base cabinat
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into me in cantor' of counter.
3. ALL Lumber to be used as Beam, Rafters, etc... to have slab (3/8"t 50 ksi steel plate) see angia detail
a minimum 1,400 P.S.I. fiber stress. at IIV o.c.
etude4. No dissimilar metals to touch. `"31 1/2' drywall
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. 2%" 2�," 2• x ell PT wood plate
ALL Concrete used for vertical filled cells, Cont. tie beams etc.. to �2/2"
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6. Drywall at ceilings shall be leveled and attached to bottom chord •3�s" O 2" KITCHEN ISLAND FRAMING DETAIL
of trusses with screws per FBC R102.3.5.
1. ALL wood in contact with concrete shall be pressure treated. `-�' 2;�,
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Dram at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12. Lowest finished floor to be set by Governing Building Department 2%" s'rz"
surveyor to set infield.„
13. Separation between residence and garage shall be per FBC R302A, L"
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 Der FBC R302.9.1
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 460 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R316 - see permit info box of code edition
18. Gypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
C`160, C1002, C1041,0111, C1118, C1218 C1395, or C1394 and shall be installed
according to the following: (FBC R102.3.5�
Drywall
Thicknews
Loeauon
Onantation
Frmr�n9
air
May- spacing
fasteners
Narl anzin options for
Spa
of
installationfir wall into
Nails
Screws
Maximum
Mawmum
wood framing members
2" x min. thickness
Ceiling
Perpendicular
24"
7"
12"
13ga 1 3/8" long with 141/44" head
0.098° diameter x 1 1/4' long
„
yz
annular -ringed or 5d coder nail
OR
0.080' dia. xx 1 5/8" Ion with
g
Walls
Direction
IL'
S.
IL "
IS/L4" head
R
Ggpaum board nail 0.086" dia.
x 1 5/e with 9/32' head.
Calling
Perpendicular
24"
1'
12'
139a 15/8" long with MAD' head
0.098' diamiRter x 1 3/8' long
annular -ringed or Id coder nail
s
OR
0.092" dim. xx 1 1/8' long with
Walls
Direct
IL
S.
IL'
ion
1/4' head
OR
Gypsum board nail 0.0915' dia.
x 11/8" with 19/64" head.
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with AS"rM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceding assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanging smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MPG 5v Crimp Metal roofing FL #114,51.12
24 gga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin cape and with 1.25" ring shank nails
spaced V o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
ir VTR
I2 MASTER
2 I ��
I" II�wI` TIiII BATH
e' 3:,
a
Lnvi doll " ,�•I
"
KITCH
EN
LAUNDRY
MY
'4
iER
I2'
I
'2Vi
2' 20
nt.
Window Schedule
Mark
Size
Rough Open.
Window Descri tion
PRESSURE ZONE
1.
4'-5Ye"x 4'-L %""
54Ye"x 54Ye"
Smgle Hang
ZONE 4
2.
V-2 Ye"x 5'-3 %s"
15' X 43 %4"
satgle Hung
ZONE 4
3.
2'-2' x V-2%"
21k"x 38"/e"
Single Hung
ZONE 4
4.
3,-1' x 5'-3%"
I Sam x 63'/4"
1 Smgla Hung
I
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per
elevations.
ALL windows to withstand
pressures in permit info box
On sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturer a specs
prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Descri tion
PRESSURE ZONE
A
9'-on X 1'-0"
108' x 84'
Overhead Garage Door
ZONE 4
B
V-0e X V-8'
41"'A" x 83V
larberellaws Patel - lamming
ZONE 4
C
L'-OM X L'-1i'
14' x 81 %2" nca
SYBng Glare Door
ZONE 4
D
2'-0e X V-8"
Solid Core - Wood - L-Panel -OP-Fold
Famished 24e x 81
E
2'-6' X L'-So
Solid Care - Woad - L-Penal
F
5'-09 X 6'-81
Solid Core - Wood - L-Panel - Ba-Pak!
G
'-W x L'-8' x 1 %,"
Solid Core Wood, Steel, or Mesarte Dow
H
2'-8' X V-Se
Solid Core - Wood - L-Paaal
J
T-L' X V-8"
Schd Care - Wood - L-Panel - Br cW
ALL Exterior doors to withstand pressures stated
box on sheet #I
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
in permit info
AND SHALL
ON SHEET #1
Attach buck to block mall with
1/4' dia. Elea cone across with on.
1 1/4' penetration at 12' o.c. max
and 4' max from each corner thru
Exterior two
2' x V PT Buck
d ad
If
anise
as weed screws alto iamb into buck
Detail
at each tarps and 16' e.e. max and
at Door prow to da r attaahwant
NTS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB. HEADER, AND
SILL
BLOCK PRIOR TO BUCK
INSTALLATION
Instal windows thru buds into
black with 3/I4' tap -can with
1 1/2' penetration at L' c.c. max
r�•ow ea,�cchh comer and 20." &a. wax
tharealter ba 20'
Exterior face
at and c.c. max.
at head and ill pm product approval
of will
Sufic to be r ■ 4' PT
Vanes
I'x4' P.T. Buck nailed to
Detail
lock with eau hwdened made
at Windows prior to window attachment
NTS
12"
Simpson HETA 20 or equal
hurrteane one at each true 12 Masonry Beam
PRE-ENGINEERED TRUSSES
with (10) IOd x 11/2' nails I" x L" P.T. Buck nailed to
r block with case hardened nails Verif attachment
( 24" o.c.) cuppportmg Max 41 at 24"o.c. TYPICAL 9
18101bs. upldt (shop drawings by manufacturer) prior to door attachme hole location with GC
Install SGD thru buck into prior to fabrication
block with 3/16" tap -con with 3/8" thick L„
r'.x__ ` ``- I I/2" penetration at L" o.c. max steel bracket \ /
Aluminum Drip R-30 blown fiber lass from
each
ai headnde20roduct max
s roost
g p p pp
Edge t Fascia in bottom chord of trusses
�
I/2' drywall with smooth finish
2" x L° Sub -Fascia Two rows of beam block filled with concrete o O Use 3/I6" to con with COUNTER TOP BRACKET DETAIL
and (1) #5 bar cost. in each row. Substitute " P "
Kagcan full o vent vangI aoffit metalled precast lintel filled with concrete and (1) #5 I I/2 penetration at L o.c. max.
using 1/9' dia shank x I.5' long gale. bar cunt, for bottom row over openings from each corner and 20" o.c. max
reefing mails with 3/8' din. head per thereafter at sill per product approval
product approval -see chore slat al 1/2" drywall over I' x furringg
strrpa at IL" o.c. with R4.1 P'rfol ill x L' P.T. Buck nailed to
insulation on tgpncal 8' Block walls block oath case hardened nails
S/e" thick light textured All drywall to be installed per FBC R102.3.1 Head prior to door attachment
-
rtamin ASTM codes.
and shall meet all pertaining stucco on typical concrete as Mortar to be T e 'M' onl proportioned per FBC R401.1
block construction gp gg P oP
and Mortar joints shall comp
rg with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) fixed door
#5 bar vent, w/ sliding door
30" overlap Fill cell with concrete and ..: ":_;'•
at each filled call lU #5 bar vert. (typical). ro Masonry Wall
ax apacing shall not exceed
48" unless otherwise noted ,'" i vz.
Wood see foundation plan notes for
Base spacing at openings
BottomTrac Typical Flooring '
4" concrete slab with hbermesh OR Bill II Install SGD thru buck into
L'xV #10/10 WWM on L mil Visqueen over block with 3/IL" to con with
clean compacted termite treated fill P-
S I I d i n g D o o r D e t a i I I penetration at L" may
Grade fromom each corner and 20.."" o.c. max
thereafter at iambs par product approval)
-- At Masonr Wall NTS afYlb
-�I li,ll11I1
I� I . " BradeArcFntB►�fdePlanr�ers�4, Pit
- ICI 14 x 14 Concrete fooung
with (2) #5 bars comt.and #5 411 S.E. Coconut Avenue
transverse bars at 48" c.c. Tel : (112) 281-8258
TYPICAL SECTION Fax : (112) 281-8283
Scale : 1/2" = 1'-0" E-marl: bradenaiaecomcast.net
Stuart FL 3192.4 #AAC0000 2
CIE 8'-IOYs" T "6 " 8'-IOY2
EGRESS ° 12" x 12" Concrete column
block filled with concrete and
(2) 47 bars vert. tied Into
13'-II" lintels above
Filled cell under
° r girder above PORCH
WIRE LACILINGTUCCO p
1 ILIN b
MASTER
BEDROOM
J1118'-O" A.F.F.
Flat Ceiling
Vanity to be
4 Y2"high
° Rod t shelf
o , in
°
an
LOS T I o
I °C
H.B.
° Rod t Shelf
-
cl
= 32" DRYER ASHER
Of O v 5- 3 in
a 5" LAUNDRY
� Oi in
F it
° Vanitt��to be
42 34 Y2' high
re, /� T
1rE ;r
I
I °
I O
8'-0" tol9'-8" A.F.F.
IRV Vaulted Ceiling
GREAT ' ROOM
I _
Mtn
rn
I r
I Qu in
AN
a-
I °
I
f-Iiiii
I E
1 8'-O" to 9'-8" A.F.F. O
Vaulted Ceiling
DINING
I ROOM
s to
nwg owall 15" 13/8' thick steel °
90„I counter top aupperts
rzeq. eq. counter tops to
over ang wall
In
v
�l.
ED
/�qD
SECOND
+41" high wall
° i DW
I n
°
q
BEDROOM
i
KiTC1HEN
-
8'-0" A.F.F.
8'-0" to 9'-e" A.F.F.,
a
Flat Ceiling
r
O
I
Upper cabinets to
Vaulted Ceiling
Q
-
I
extend over Ref.
I
°
I
REP.
Nox V
NT
I
°
ae' CLEAR
OPENING
L
H B
,
r�
-
-
--
-77
- - -
6
°
r
R-0 Oat, Inrismen `r
W.H.
Provide
THIRD
©
sat®
closer
4"m Steal Ballard
Bea detail this
°
BEDROOM
on
sliest
rya U1
J ®I
xA
°
o
I
I
Ate Access
la d
L_amW&_J
=
8'-0" A.F.F.
ifi
I
IL - -
°
Flat Ceiling
'-A.F.F.
A/C
`r
Flat Ceiling
#1
T GARAGE
°
I
O
rc
O
�
°
in
Block wall rn
-
MT
°
,/garsga to be
°
R-1 beets liiwiatian Provide
closer
auto
°
2'-8"
'
°
,a// struck block r+
13' -O"
150 Amp
6' -4
°
Panel
EMERGENCY
°
_-----
EGRESS
------------
3
°
I GOLF C,ARTI
I
°
cr
I GARAGE
I
uo
I
I
cr
n ;
----
° E,
°E
Ell
®
2'-8"
9'_O„
2'-8„
2,_8„ JOE
q,_O,.
Bel
F
Square Footage
Breakdown
-"
GCC
Total A/C Space
= 1,153
eq. ft.
Covered Porch
Total ce 212
eq. ft.
Garage =
459
eq. ft.
Total
Cubic Ft
= I
9484
Wynne Building Corp. Date Drawn Revisions : Sheet Comm #
REAR 3-28-18 5-23-I8 Garage floor slope and
T I 1 E I I I I I T" 1 C� O R PORCH Drawn by: smoke detector revision 21
16 -
6-l5 9
S anish Lakes RIGHT Checked by: Impact
S . Lucie County Florida D.R.B. OF 5
.7 1 U 1, I U r� t� L I X L/ II_- %J :
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2• ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3• POISON SOIL AND COVER W/ 6 MiL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FiLL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5• LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL iN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF iTS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
S. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE ="C"
10. ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-16, E
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
11. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOUNDATiON
FLAN
I. Any
changes
to
plans must
be submitted to the architect SCALE: '1/4" = I'-O"
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell with concrete and 1 45 bar vert. at '48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5`-I1" wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-II"
I it
and Provide (3) filled cells on each side of openings from 10 -O and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 2-f" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy Of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w! Thicken edge to 8"x8"
30" overlap SECTIONS AL with concrete and 4" concrete slab with fibermesh OR
at each filled cell one #5 bar continuous 6"x6" #10/10 WWM on 10 mil Visqueen over
\ clean compacted termite treated fill
FOOTINGS
SCHEDULE
Mark
alas
Deser
tisn
I
14"W
x 14"D
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS
12"W
X 14"D
MONOLITHIC FOOTING
- C
STEP DETAIL ON THIS SHEET
30"
x 30" x IL"D
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH
1 #5 BAR CONTINUOUS
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB a O'-O"
12"W
X l8"D
MONOLITHIC FOOTING
- 6"
STEP DETAIL ON THIS SHEET
4" concrete slab with fibermesh OR
0xb" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
orE�t7l I IT El
I_1�1
1 I I I= 14"w x 14"d concrete monolithic
rooting with (2) #5 bars Cont.
14"
TYPICAL FOOTING DETAIL
Cif•Al = 1/7"
4" concrete slab with fibermesh OR
6 x6 410/10 WWM on Io mil Vrsqueen over
clean compacted termite treated fill
#5 bar Cont.
.»
10° (2) #5 bars cunt. bottom steel
12"
DETAIL AT 6" GARAGE STEPDOWN
ArALP 1/2" = I'-n"
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tied
into hntehi above
Top of footer
16" below finished floor
Mill
N I II=F1
I LIN
Verify house slab
height in field
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
H.B.
' F'4/ PORCH SLAB EDGE DETAIL
\\ SCALE 1/2" = 1'-0"
#5 bar vert. w/
30" overlapA/C
at each Pilled cell
SEE TYPICAL
ECTIONS " `.:
AdjusMe Ar Amid
t curb height on either aid
based on gar. floor 4" concrete slab with fibermesh OR s `. `. . hove hew v
slope. 6"x6" #10/10 WWM on 10 mil Visqueen over service locat
#5 bar in curb clean compacted termite treated Pill
O -O" ® F.F.
Grade 2" x 6" PT wood secured with
3/8"dia. x V anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
114"w x 14"d concrete monolithic GARAGE DOOR TO WITHSTAND PRESSURES STATED T CJ 0
1 i i i i I footing with (2) #5 bars cunt. IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
14" APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
x.
4_�3011x3O"A4"
concrete
column footing with (4)
#5 bars each way
3O/
,OTING DETAIL
Mac"0
CURB DETAIL
4" concrete slab with fibermesh OR
611x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Ln
101, (2) #5 bars coat. bottom steel
12"
DETAIL AT 9" GARAGE STEPDOWN
SCALE 1/2" = 1'-0
"
4+5 From Footing To Beam Each. Filled Cell Masonry Column With One
Conc. Fill To Be 3000 PSI
See Floor Plan For Location #5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
NO�• r
Double Filled Cell Column Single Filled Cell Column
` NTS NTS
rr
i(
15'-3"
r — — — — 76� — — —
I I
I FI I
I 24" °
I
FI r
I
Thicken footing to
I 24"w x 14"d x 24"L I °
under filled cell °
under girder bearing. 1 °
12"
x 12' concrete
column block Pilled
I
with
E35'-O"
into
concrete and
lintels above
(2) #1 bars Vert. tied
10'-0
— — `a
—L_J~--
— —
®-- °°
®
T
o
I Filled cell under
r der above
Rear
r
Porch Slab to
O
I
be poured separatelli
W
from
House Slab.
O (�
p
Ca
I
/ k
— Rear Patio/Slab to
be Plush with bottom of
I
sliding door recess.
Slope I"
I
I
I
I
t/ \ 4" concrete slab with fibermesh OR
I 6"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill 1
I� I
I I
0
I(Ci) DRYER AbHER I
I I
I I
I I
�I
,I
II
i
I
i l
I
i
i l
I
FI 4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
I clean compacted termite treated fill
I
I
II
I
I
I�
I FI
L— $ F6------ r — — —— —
o 0 .
LU
I O 141 Step
W
I to _ O I
f
17
I 1
I
------a-
° 1.5" Recess for M71
9'-0.
Braden it Braden AIAe PA Wynn p Building Corp.
Archlltects - Planners
TelS.E. Coconut Avenue THE I I I j N D S O R
Tel : (112) 281-8258 I 11�—fi u•+ I +-� I �.
Fax : (112) 281-8283
IkB E-marl: bradenaia®comcast.net S at
Lakes
Snow"+ r-I '2ACkQL ttAAernnnnz) S . Lucie Counttg Florida
I.
II
I
i
I'
i
i
I
FI �
I
I
I
I I I
o •° I DW i
I I II
n I
I
MICROWAVE
RED. NON -VENT
se• c�EAR
OPENING Q Q
I -- v ---- W.H.
I 4"* Steel Ballard
See detail on this short
II 1
II I
II I
I ID � I
Ii a I
ti N I
°I I
°I I
I I
I li
I I' I
I
I i
I © --J
0 ° 1.5" Recess for O O
Garage oor
2'-9" 91-0. 2'-a"
cil
Date Drawn Revisions :
REAR Drawn
5`23-18 Garage floor slope and
Drawn bg: smoke detector revision
PORCH C.C.U.
RIGHT Checked bg:
D.R.B.
ff"
n
0
I
Sheet
3.
OF 5
Comm #
15-159B
impact
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum (Vail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = #8 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws bas d on Presage for roof stated
in permit info box on these pPans for zone 3
Ke
Area
Ede
Field
Fastener
Pre sure
Zone 1
L"
L"
8d ring shank
45 psf
Zone 2
4 of
4 H
Sd ring shank
"IL pSf
Zone 3
14 of
Ig if8d
ring shank
84 Pat
** Zone 3a
L"
L"
#8 wood screw
112.5 psf
** Use nails or a4revs based on pres ure for roof stated
in permit info box on these plans ?or zone 3
Concrete
/ Lintel
Column
Verify with Plan
Rebar
to Lintel
C
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled call steel into continuous
beam block steel.
Provide Cast -Crete =-
8U8-OB/OT precast ' ---
lintel set in mortar
Min.
Min. 8' Bearing
x 12"
n Block
Provide #5 bar set in pre -cast O C F FL A N Scale : 1/2"
hntel into boom where length of
the opening calls for it. t 1'- O ii I t h t d t h h t
a PT Buck
od per iamb
into filled !
!lI 4" Pre -cast
I i I sin
sir angs a un ass O erwlse II a On Is S ee
— Roof pitch at 4:12 unless otherwise noted on this sheet
— Truss shop drawings to be provided by manufacturer
— Any changes to this plan shall be submitted to the
-- architect for approval in writing prior to starting construction.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prior
rowed Fined Cell to construction for layout and uplift verification
— Contractor to provide for Form Board Survey and to provide
Form Board Survey to Truss Company prior to truss construction
Provide 85 bar& with min. 46 bar
Pa.tarsoverlap m fined call. Tie
fined call steel Into continuous
rooter steel.
I Concrete Footing
J 4. (see footer schedule
,r rr .r a... rt-.}.�,�.....
for exact also)
DETAIL AT WINDOW OPENING iN
CBS WALL Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Had 2' x 4" blocking to vert. leg or
train with IOd x U6 rills at 4' or-
n Instal Siwipson MOT into well wing
5/89 olio thresdad r set IMP r1'
\ Into set bum and � ) IOd rob Into trims
vg�
Reber 14148 Bar Dia. TRUSS BLOCKING DETAIL
Min. Overlap 41AT GIRDER STRAPPING
m n t AT CENTER BEARING POINT
NTS
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D tgpe 2 paper backed
wire lath nailed to substrate through one iayer or
ASTM D Type 2 felt paper using Bid minis. Substrata
to be 19/32" CDX Plywood nailed at As o.c. in Field
and edges with IOd ring shank nails into studs.
Gulr Coast Supply and MFG 5v Crimp Metal roofing FL #i1451.12
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5'
wood screw& with self sealing washer at 12" o.c. max specing over ASTM D
ftype 2) 30 lb felt underlayment installed with min. 4 side tape and As end
laps fastened with corrosion resistant tin cape and with 1.25' ring shank nails
spaced L" o.c. at all late and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Additional recast Lin al
#5 bars =
Lintel
Bar
Clear
�� ii
A
❑ n
B
r'.: CLEAR
i '�;-w i i +•• °:' i i ' : i
Length
Length
Span
Bars
Bars
2'-10"
2'-8"
I'-6"
2,93
none
3'-6"
3'-4"
2'-2"
2,43
none
SP8-015AT 8P8-15/IT Ns8-Id/2T
Additional
its bars ;
cuA ;43rs,� ; ,.;
.,, , me Row of N ,,: • ;;
tyy Block Above ;•ti, '�;
Z.
-:,r>;:` :.�.r
r ,;,...:,; Precast Lintel r =•:: 1
' i
i Additions t� i
�----r #5 bars ----r
4'-O"
3'-10"
2'-8"
2,43
none
4'-C
4'-4"
3'-2"
2,93
none
5'-4"
5'-2"
4'-O"
2,43
none
2,#4
none
6'-6"
6'-4"
5'-4"
2,44
none
rt'-G"
7'-O"
6'-2"
2,45
none
BFIL-n3/IT BPIL-I8/2T
NOTES:
8'-4"
1'-10"
T-O"
2,#5
none
ALL reinforcing steel is grade 60.
L min, coverage of steel-1.5"
I min. bearing required a ea. end=6"
3. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
�t PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Dow
Unit
WidthSloe
Lintel
cast -Crete
8 euheatumm
owl
BlackLp�
A
dottaw
Steel
Tap
Steal
S�
Max
(PLP)
Max.
fPLP)
Max.
LeUpkft ad
(PLP)
L22
2'-2'
V-L'
Nos-OBAT
1
85
300
KL9
1024
L31
s',
i"
4'-0-
8P8-OBAT
1
#5
26LI
13L3
its
L45
Y-5'
W-10'
�8-08AT
1
85
005
40'!
331
L50
5'-O'
L'-0
N'S-OB/IT
1
#5
1236
8S6
Im
LAID
L'-8'
T-V
N'8-OS/IT
I
a6
ion
121
04
LSO
8'-0'
T-4-
�8-IB/2T
1
85
2
85
152
611
611
L410
T-O'
10'-L'
N<8-I5/2T
1
#6
2
85
643
530
401
L10B
1'-O'
10'-L'
N9L-ib/2T
ONE
1
85
2
#5
B33
us
401
LI00
10'-O"
II'-4'
BPS-Id/2T
I
8b
2
85
562
4014
462
WOOD
10'-0'
II'-4'
OPIL-Id/2T
ONE
I
85
2
#6
MAL
1028
462
L120
W-0'
19'-4'
N°8-18/2T
1
85
2
#5
411
428
324
LI205
17-0'
131-4'
N9L-15/2T
ONE
1
$5
2
85
1015
110
324
LI40
W-0'
151-4'
N<IL-I6/2T
ONE
1
86
2
85
1250
L04
251
LILO
IL'-O'
111-4'
N S-IB/2T
I
a5
2
a6
300
M2
M4
LILOd
IL'-O'
IT-4'
N<IhIB/2T
ONE
1
#6
2
85
150
Soo
M4
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LiNTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0' LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at erlch truss
math (10) tool x 1 1/2 nods -
1 24' o.c.) supporting Max.
ISIOIbs. uplift
Aluminum Drip
Edge t Fascia
12"
2" x L"
Kamcan full o vent viral soffit installed
uarrgg 1/8' din shark x 1.5' long gaiv.
roofing riwb with 3/8' dia. head per
product approval - see chart cheat #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tied'—
into lintel* above
thicken edge to 8'x8'
with concrete and
one #5 bar continuous
BEYOND
Top of tooter
IL' below Finished Floor
12
4
1/2'
Aluminum Drip
Edge t Fascia
Flash and Counter
naafi —
Nml ledger to
gat is end truss
with (2) tool rwLda
at each web
on 3/8' hi -rib lath
nul and vertical load
ir staplesProvide
4' penstreLLiian ifte
msrg snd membe3/4rs ramma ' psnatratxm
f
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be Plush with bottom of
sliding door recess. Wood
IE Base
Step per foundation plan
Slope per foundation plan 'r
.' .• A ',
—I1 IIII IIII
:.III IIII III IIIIIIIIIIII—III III
�""J�x" IIIIIIIIIIII—IIII Mlle III I
Tubical Section
�
r_
N
X
a7
�
s
OW
�
HW
a.a
n
_ $
�+ a
n
EW
W
N
u
C4
Brace Gable and
with 2' x 4" SYP #2
Oft back nailed to bottom
or top chords using (2) IOc
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
e 24"o.c. TYPICAL
( shop drawings by manufacturer )
dR-30 blown fibergglass
in bottom chord or trusses
-1/2" drywall with smooth finish
Two rows of beam block Pilled with concrete
_and fl) #5 bar Cont. in each row. Substitute
precast lintel Pilled with concrete and (l) #5
or cant. For bottom row over openings
1/2" drUwall over Is x Purring
atrlpa a IL" o.c. with R4.1 FI-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R'i02.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" on11 proportioned per FBC R401.I
and Mortar joints shall coinilg with FBC R101.21
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
ll) #5 bar vert. (typical).
-Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
VxV #10/10 WWM on L mil Visqueen over
/ clean compacted termite treated Pill
I;I;II IIllLlliillll
I_
II':I
-
FI
at Front Forc
Scale : 1/2" = 1'-0"
Simpson HETA 20
Strati truss to wall
using Simpson MGT wit
hurricane anchor at each
truss
5/8 dial,
into beam
threaded rod with min 12' embed
either wet set or in epoxy with
( 24" o.c.) supporting
1810 lbs. uplift
Max.
HETA
2O
(22) IOd
truss leg
nails into
per detail
truss. Add blocking to
on this sheet
11
,
0 WARAM WA i F", A
I
1�MWIA
I
PA IN E
I
a WN
M
1111111110 01 N
�iMEN`
I
SWE
IIIAFMA��■
II
�
�.�il
III
I
EWA EWAN
I
I
0
VAIVA MAIN
I
I
I VAA MAN
6 01
is
ra:
OUR
CHETA 2
Provide damn t Simpson HETA 20 Provide for/ gutter
�°" hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
e,
w
x
� W
a-r
� a C
4
LU
2 s "'
u r. Q
u
�a
E_C= OD
U N
r_
L
I
ILLI
O
I
i-
Provide downspout
■
Opt. PATIO/SLAB
PANEL
"A"
Pales
BR
Lead
WFe
Desenptw
arcs
aa'e
Deso ption
Wire
Land
SR
Poles
1
20
L2 ke
$12
RetnWatar
I
Itunap
eL
12.0 ka
60
2
1
20
L2 Its
812
Clothe Washer
3
1
20.
1.6 ks
ill
Kitchen S.A.C.
5
6
Dr er
NO
5.0 ke
30
2
1
20
1.6 Its
ail
Kitchen S.A.C.
I
a
1
20
812
Bathroom Reeepts
9
10
AFC
$10
5.0 ke
30
2
-
1
20
1 1.2 he
012
Dlehuasher
11
12
1
20
1.2 ke
$12
nieraseve
13
14
AF Hand
a10
5.0 ke
30
2
1
15
-
014.
Genwd Lighting
15
li
I
Is
814
Genera Lshtrd
11
N
WH
e10
5.0 ks
26
2
-
1
15
-
#H
General Lighting
4 -
20
1
15
-
$14
General Lghtmg
21
22
6D0
$12
0.81 KU
20
1 I
1
15
#14
General Lighting
29
24
spars
Spare
25
2L
Span
spare
7-1
1s
spare
Span
29
30
span
PANEL "A" LOAD CALCULATION SHEET
Load Description
(2t .
Watts
Total(Watte)
General ,Lighting !3, watts„sq; , fi;)
Small, Applianee, Cgeuit(s? , , , , , ,
.R4Vglq...... ......... .................. ................
.Rgfrrgerator..............................._..................
Microwave
rah , Washer
101.8.h.........................................
.C10I)Ve. wAlhof........................................ ,.....
.C,*bvik Dryer-------------------------- ............
Water.Heater
.............................................
GaregP,Door,Opener..................... .....
I'186
3
6 206
2
1,500
3,000
1
12,000
12,000
1
1,200
1 00
1
1500
1.600
I
1.200
100
1
1200
1.200
1
5000
5000
1
4500
4500
I
810
810
Total Watts
35.A5
First 10000 Watts e100%
1
10.000
10,000
Remainder 29AS e40%
1
O
10.24L
Electric Heat or A/C IOA00 e116%
1
10.000
10,000
Calculated Load
Watts
30.244
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps F 12L.02
Panel Size Required - 150 Amps
'lectrlcal S mbol Le end
S
Single Pole Batch
®
Recessed Can Light
Sa
Double Pole Batch
®
Eyeball Recessed
Push Button Batch
>S
Exhaust Fan
-8
Duplex Outlet
Calling Mounted Light
Special Receptacle
j ♦
Wall Mounted Light
:= ground fault circuit
Light with Pull Chain (attic)
Flow Duplex Outlet
©
Computer Connection Jack
®
Carbon Mlonasade Detector
4&
Flood Light
T
Thermostat
m
Electrical Panel
Central vac
8
Electrical Meter
®
Smoke Detector
Calling fan
®
Television Jack
Telepliorw Jack
a oSC
A/C Disconnect
I x 4 Fhtreacent Light
2 x 4 Floreacent Lr
®
Speaker Hook -Up
Q = JUNCTION BOX TO SUPPORT A PAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
ELECTRIC NOTES:
I. Use copper wire only from panel to devices
2. Provide and wire all required smoke E Carbon
Monoxide detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL bath and kitchen receptacles to be GFCI protected.
5. ALL exterior outlets to be WP/GFCI protected.
L. Recessed cans to be Installed per NFPA requirements.
1. Tamper resistant AFCI receptacles are required in
ALL rooms-
8. A/C Return Air Balance Must comply w/ FBC RMIL02
9. %C Refrl�v8 Imes that are run thru slabs must be
aseve in
10. ALL A/C Equipment shall comply with energy calculation
11. All work shall be performed by a licensed electrical
contractor, the completed stem shall be fully operative.
12, Contractor shall pay for all eve, permits, testin , and
Inspections including blower testing where required.
13. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
14. All required insurance shall be provided for protection
against the public !lability and property damage for the
MECHANICAL LAYOUT
SCALE: 1/4" = 1'-0"
15. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
IL. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necesaarg for the equipment to be placed in
proper working order.
IZ. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances. and shall
meet all standard requirements of the local electric utility
and telephone company.
18. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
19. All material shall be new and shall bear underwriters'
labels where applicable.
124 CFM
IOidOxL
MASTER'
BEDROOM
124 CFM
IOldOxL
F-,
12x1:teTd
B/A
5o CFM
s�
9 FM
WON
IL CFM
sx4x4
OSET
r_i
B%A O
- F-1
141 CFM
IO)d0xl
DRYER ASHER
LAUNDRY
Ill CFM
12xtxl
SECOND
BEDROOM
12A2 F♦-, _ - - r
THIRD
BEDROOM
100 CFM I j O
IOxLxL
14�1
150 Amp
Panel
GOLF CART
GARAGE
I I
I I
I I
I I
I I
I I
I I
I I
20. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job condrtrons.
21. Furnish and install all fixtures as called for on the plans
or as selected by others.
22. All raceways and pipes placed in or through any concrete
stab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
23. All exposed wire below 9'-1" shall be Installed in metal EM1'
conduit.
24. Dr er Vents to be installed per
F-YC RMI502
U
PORCH
141 CFM
IOIdOxl
REATI ROOM
I
I
I
I
14-1 CFM
I0)d0x1
I
DINING
ROOM
I
DW
I
I
"I
I
124
KITCHEN
dOX6
1
MI OWAVE
R!R
NON -VENT I
3a' CLlAR
OPENaiG
L - 0 - - -
4"4 Steel Mallard
See detail on this sheet
22' x 54' ,
I Attes
m h
- - - - - J
GARAGE
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
r, I
? I
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8268
Fax : (112) 281-8283
":1-marl: bradenaiascomcast.net
MASTER
BEDROOM
%i
E
�T
SECOND /
BEDROOM/
® l
r /
3 TON SISE) /
SEE MANUAL /
'J' and Energy /
Calculation /
for Unit into
Install oulet THIRD
under disc. B E D R O O I, h- "-
not own for sh
clarity r
WP CI �
fir
A/C /
ul /
/
100
PORCH\®
"m
WP GFCI \
I (V I -I
I �
I
I
I
I
I
I
GREAT � ROOM
I
�I
/ I
DINING
rrr/' i ROOM
I �
I �\
I
�
GFCI ° 1
I
C.M. Detector
on[ yg per FBC I 1 Fc
R314.3 }THEN Bar - ""I
I ® rsc V! OFCI
1w� ••
li"
11 �� 20
.`.
••Ill'•.• R(W:
�'•
7H
Y
'4"40 Steel
Ballard -%
•
'��LOCATION
a
FCI / �\ GARAGE
Q / / �/1 GFCI \
150 Amp I\ l /_ / `\
Panel Grcl \ ,@t� \ ` GFCI
r-------- ®-. / r--------------i
Garage 1 1 Garage
Door Door
Opener I / I Opener
I
I GOLF CARTI /
I GARAGE
GFCI I 1 GFCI t0 garage lights I I
1
SIMI
r----
r �
� r
ELECTRICAL FLAN
Past Lighm r"18%h � I
SCALE: 1/4" = I'-®" Photo cell
Center Pomr 3 F44
Attic Ventina Calculations
Total Attic Space = 2101 sq. ft. C 3 9.
Venting Ratio 1/150 = 18.00 sq. ft. required
Provide A Continuous Vented Soffit
Wynno Building COrp.
THE WINDS
S anish Lakes
. Lucie Count4 Florida
between awoga z)
Wire For
Front Post
Light
REVIEWED FOR
CODE COMPLIANCE
ST. LUCK COUNTY
BOCC
Date Drawn : Revision& : ISheet Comm >R
3-28-18 5-23-18 Garage floor slope and i
REAP Drawn b : smoke detector revision
PORCH c.c.u�
RIGHT Chocked bg: ` Impact
`The Architect's or Architect' s representative s.
III
T shop drawln
g approvallls NOT a
"double
e char R TRUSSES AR U L R ■AT MOD & of th MUNIL ■ er: nr.
TRESSES FOR TEE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFUL■ SET BEFORE ANY btactor.
tv
The contractor shall remain responsible
A AR ANJE WITH CRANE OPE TOR IN ADVANCE FOR A SPREADER BAR OF 18'- 24'IN LENGTH A far royal overdmeaaurements and
other construction criteria. Architect's
approval covers goneral roof shape,
review of truss strapping, and loading on
A Do not stand on trusses until they are braced per SI properly nailed to straps hangers sir°ctutheir egr veloc�io loads
y�
DON'T LIFT
TRUSSES
WITH SPANS LONGER
THAN
30' BY THE PEAK.
CONSULT
BCSI
30' Spanor less
30' to 60' Span
/ c- degrees
�oi :ess
Spreader Bar
�—Approx 2/3 to-�
/. �_.ag
--�G Jne Sj'iCn �PProx
Line 1/2 of Span`
REFER TO B C S!
REFER TO BCSI
russ must be set m,s wcy " crane used.
Truss must be set. this way if crane used.
-
Truss an exompie, yr r,ss -ay gat ratan.
si Inst crane .operator sets truss to s way.
This is an example, truss may not match.
insist crane operator sets truss this way.
1a
r
SEAT PLATES BY CHAMBERS
12
4.00
B,
M
upset=1/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL EN
D DETAIL
12
4.00 —
�— 12 2.00 $_ --
{
upset=1/4" 115/16" INDICATES LOAD BEARINC
PLUMB CUT END REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
2 x 4 Top Chord AT A HEIGHT OF 8'-0"
WALL HEIGHT 8' ABOVE FINISHED FLOOR
END DETAIL: TYPICAL VAULT
r Dapravea ny:. 'rf
19' 9" - ---�`� 3" - — - Ci L i7 ^ o Braden a Braden A.I.A. P.A.
-- --- /
®�_1
I I////®�////�yI�/�jp�►lq/®//�I►y/®/%i/y®/��I�/®��!�y�!I/.�!�//®I�//
I®I//®/�I�//®I®!®
�,/�I�I/y®//
I
POP
II
yFRO
IPA
Emma 0.
1
4
OAF
110
rM
IPA
MINI
-
— —
---
Fall
0is
10
old
Oil NPO
r r �._ �.�`■%�
_
■0®_
ON
MINI,
•50#
'
�_IL
- • a
POINT
�i
ON
1i0
PAP
0.
_■��
_—
1
r sLTR8gK BOSTON Hip-, MO--�/_.�'
.110
'1NON
I
14'-4"
\I`\\\\\I\\\\
I`\\\II\\\\`I.
\.►lam\\\\
\`\`r
�1IA1S�`\�11�`\
.\�\\\11\=
ISM
IV
1�.i
i`-�2
\
11
1
Isliffil
-
--
—
MIN
MINI
Ii
W11
MINS
—
INVERTED *V" WEBS AT CENTER
50# PO T LOADS PER TRUSS FOR A/H/U
1°
Mimi__
BOSTON HIP
OK
_■O
,
W
\
• .
1
I �I
\I
.
1 ,
1lk
.,
.,
\
.
•
1
'1
,
,
.,
I®I®I
i®I■imimilimimimimi®I®i
l®��►
I I
I
�.'-_�
i� CLOUT ED AREAS ARE OF
J SPECIAL CONCERN & MUST BE
CHECKED CAREFULLY & MAY
1 INDICATE DEVIATION FROM �__�<
LANS.� ��•�_-��
- FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETURNED
The legal description of the property where the trusses will be Installed is:
The undersigned ecknovdedgea end agrees:
1 Tmssea coil be made In ship ece0Mence with I'll truss placement dlagram layout,
which is the iota authority for detannlning. successful fabrication of the Wasea,
2. All dimensions In this layout have been verified by the undersigned.
3. Unless written notice Is provided by certl8ed mall to Chambere Truss within ten (10)
days of delivery the undamlgned agrees that no backcharges will be allowed..ln the avant
Ouch written notice la fumished Chambers Truss shall have three (3) bug�neas days in which
to begin repairs required, or to subsdMe other trusses, et Chambere optbn.
4 n ens ned e . The u d acknowledges edges receipt of "SCSI 1-03 summe
b. Delivery b to Job site. It le the buyer's'rea ry sheet by TPI 8 WiCA:
ponelblllty to make the Job aae suitable for
delivery. Chambers Truce hie the sole authority to determine the cultablllty of the Job sfla oY a
portion of the Job site for delNery, Chombere Truss will be maponslbla for dump delivery only.
The buyer Is responsible for ad on
delNs, expenses B Chambere Truss has to redelNer
because Job she Is not prepared for delivery or buyer Is not prepared for delivery of trues...
Buyer Is responsible to Chambers Truss for towing costs due to she conditions.
S. Pdas as shown Iq paragraph 7 below Is subject to change a any changes are. made In
this IayotrL A $50 per hour fee for revisions may be charged by Chambers Trues.
7. This Is a PURCHASE ORDER to Chambers, Truss o1 the sum agreed to, or If no
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net
on delivery, Invoice may. be made at scheduled date of delivery If buyer cannot accept
delivery of fabricated trusses. The undersigned agrees to pay Chambem,Truss reasonable
attomey's fee for collections In event of payment not timely made, 1.12 % per month service
charge will be added for Oil sums not paid -within tame.
. S. Signature or InItlels anywhere on this sheet constitutes agreement to all terms herein.
B.ln conalderetlon of Chambere Truss eManding credit for this materiel the underelgnad
uncondttlonelly guaremeee payment when due of any and all Indebtadneae owed to
Chambers Trues by any on receiving material and the undo Igned agrees to pay such
Indebtedness Including attorneys fees, If default In payment for material be made by the
reopient.
10. In the event of any litigation concerning this agreement; the Remo rumored hereunder
or payments referred to herein, the, parties agree that the sole venua for any such action will
be Saint Lucie County, Florida.
11. Design responsibilities are per "National Standard And Recommended' Guidelines On
Raeponsfbilldes For Construction Using Metal Plate Connected Wood Trusses
ANSIfrPIM?CA 4.2002
DATED v
SIGNED
FOR TITLE _
Aspreade► bar maybe riquired per "BM J-w, to prevent Ill & damage,
Multiple ply trusses must be fastened together per engineering
before they are set, failure to do so can result In roof collapse,
Temporary and permanent bracing are required and can save life
and property and Is the responsibility of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Trusses must be set and braced per design to prsvent Injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing are
or any
other co'dcentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELNERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3106 Oleander Avenue
Fort Plercei Florida 34982-6423
800-551-5932
Fort Pierce 772r165.2012 Fax 772-465-8711
Vero Beach 772-569.2012 Stuart 772-286.3302
eta,,. rue uCCOQT01 s'S rAM r
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
ST LUCIE COUNTY
Wind Design Criteria
ASCE 7-2010
Wind Design Method
MWFRS/C-C hybrid Wind ASIDE 7-10
•�
Roofing Material
Shingle or Shake
0 Ord
Loading in PSF
Roof R.D.L.
Top Chord Live
20
N o
L
Top Chord bead
7 4.2
0,,j
Bottom Chord Live
10 Non -Concurrent
o c _
Bottom Chord Dead
10 3
TOTAL Load
37 7.2
oDuration
Factor
1.25
m
Wind Speed
165mph
rn
Top Chord C.B.
Sheeting by builder.
r
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
15'-0"
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Wore Category
C
REVIEWED
Island
No
CODE COMPLdAbM
to FBC 2017
ST. LUCIE C
straining Dead Load C.B.=Continuous Bracing
DOC
Verify DESIGN CRITERIA shown above with the
building department and
your engineer.
Design Criteria is the responsibility of the
W
U,
15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
Chambers Truss Inc. Drawing Name: M11392
Scale: 1 /4 = 1'
82 total trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:10/07/15 Revised:03/21/18
FOR Revised: 3/05/2020
WYNNE BUILDING CORP.
DESCRIPTION:
WINDSOR
PAGE 1 of 1 CUSTOMER INITIALS EACI4 PAGE
M 11392 3 ■, ,