Loading...
HomeMy WebLinkAboutPermit WorksheetsPERMIT WORKSHEET PERMIT NUMBER Installer NATHAN HAYFORD License # IH1122082 / 31563 Manufacturer PALM HARBOR Length x width 52' X 26W FEMA or Rivedne Zone X Minimimum Required � tioa Floor at or above Min. Required Elevevation OR Minimum 36" Piers Address of home 359 TROPICAL ISLES CIRCLE LOT 09 FT. PIERCE, FL 34982 Note: Complete diagram below orsubmit separate diagram. I understand Lateral Ann Systems cannot be used on any home (new or usq where the sidewa0 tie spacing exceeds 5 It 4 in Typical pier spacing Installers initials 9Wngibudinal al 2' g' Show locations of Longitudinal and Lateral System (Use dark fines to show these locations) MAX _0o HOME PRIDE LOCK DOWN SYSTEMS. SEE ATTACHED FACTORY FOUNDATION DIAGRAWW. M■■ E- III ■■ ■__ _■ TiEDOWN COMPONENTS Longitudinal Stabilizing Device (LSD) Manufacturer Longitudinal Stabilizing Deykew/Latem/Arms ` Manufacturer HOME PRIDE Model # Model # LOCK DOWN SYSTEM page 1 of 2 a d' New Home X Used Home FJ Home installed to the Manufacturers Installation Menu Home is installed in accordance with Rule 15- Single wide Wind Zone II N Wind Zone III Double wide Installation Decal# TBD TdpWQuad Serial# TBD PIER SPACING TABLE FOR USED HOMES Lead bearing capaciy, IFooter siza (sq in) 16"rr IV (255) 18Wx181W (3421 20"x20• (400) 22x22" (454p 247x24" (576)• 2Vx26" (676) s 3500 psf a' 8' 8' • Interpolated from Rule 15C-1 pier spacing table. PIER PAD SIZES I-beam pier pad size Perimeter pier pad sae Other pier pad saes (required by the mfg.) 17.5 x 25.5 13 x 26 VARIES PER ATTACHED PLAN r Draw the approximate locations of marriage wall openings 4 foot or greater. Use this '' LLLJJJ ' symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pier pale SEE ATTACHED FACTORY DIAGRAM DETAILS X X Pad Sae Sq In 1606 18 266 16 x 18 288 x x 17 x 22 374 13114 x 261/4 348 1712 x 2212 394 20 X 20 400 173f16x253116 441 24 x 24 576 26 x 26 676 ANCNORS 4ftn 5ft❑ within 2' of end of home spaced at 54" oc 1 Other Ties Number Marriage wall 2 Stdewall 20 Shearwall 5 Longitudinal 4 PERMITWORKSHEET page 2 of 2 .. PERMIT NUMBER The pocket penetrometer tests are rounded down to Of or cheek hereto declare 1000 lb. soil 0 wihout testing. X� X_ X. POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6locations. 2. Take the reading at the depth of the tooter. 3. Using 500 tb. increments, take the lowest Ming and round down to that increment. X_ X_ X� The results of the torque probe test Is 290 inch pounds or check if you are declaring S anchors without testing . A tat showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 fL anchors are allowed at the sidewall locations. I understand 6 4 anchors are required at all centerline tie points where the torque test reading Is 276 or less and where the mobile home manufacturer may requires anchors with 17044b Iding capacity. Installers initials ALL TESTS MUST BE PERFOFU M BY A LICENSED INSTALLER Installer Name NATHAN HAYFORD Date Tested Electrical Conned electrical conductors between mulll wide units, but not to the main power source. This Includes the bonding wire between mug -wide units. Pg. 53 Flumbing Conned all sewer drains to an existing sewer tap or septic tank Pg. 54-55 Conned all potable water supply piping to an existing water meter, water tap, or other independent water supply systems. Pg. 78 and ic Waterdrainage: Natural al removed te ❑ Pad Q Other ❑ Fastsnina mull wide milts Floor. Type Fastener. LAGS Length 5" Spacing: 20" Wags: Type Fastener: LAGS Length 5' Spacing: 12" Roof e Fastener. LAGS Length: 6^ Spacng: 20" or used homes a m n. 30 gauge, W wide, galvanized metal strip will be centered over the peak of the roof and fastened with gab. roofing nails at 2" on center on both sides of the cerdergne. et nd.ek.�peaenu wa4�sm I understand a property installed gasket Is a requirement of all new and used homes and that condensation, molt, rneldew and budded marriage wags are a result of a poody installed or no gasket being installed. I understand a ship of tape will not serve as a gasket. Installer's initiate %�� Type gasket FACTORY INSTALLED Installed: Pg• 94 Between Flows Yes Between Wells Yes Bottom of ridgebeam Weim The bottomboard will be repaired and/or taped. Yesllll P�94 Siding on units Is installed to manufacturers spa ' rs. Y ftl Fireplace chimney installed so as not to allow ntrusion of rain ores eT—r. Yes= lenwus Skirting to be installed. Yes M No0Dryer j�I Rarhgevdownentflowtalveoutside of rktrhdagedoutsn�oisluM. Y= WAD Draln lines supported at 4 foot intervals. Yes EWIfical crossovers protected. Yes= Other: Is accurate and true based on the Installer Signature �; �i; f a , «— Ui o ;si—fit--.o Ai �r.c ctS/ r:ri1 '!'I .f-.CZ •ti ".WI 0��9�C�C.f-.L��.Z/I:i-.B-Fg .:H•_". r----- — — — --- --- -- — --- •r t HOM E`w PRIDE Manufactured Housing Installation Instructions Lock Down Anchoring System Wind Zones 2 & g For The State Of I -Beam Connection W 6 _> Anchor & Stabilizer NOTE: If one or more of the following conditions exist contact a Registered Professional Engineer. • Location is within 1,500' of the coastline. • Pier Height exceeds 48". • Roof eaves exceeds 16". • Sidewall height exceeds 96". • Length of home exceeds 76'. 1-7 le REQUIREMENTS FOR USE 1. The use of the Lock Down Anchoring System requires sidewall vertical ties at no greater than SW on center. 2. Centerline anchors to be sized according to the soil torque conditions. 3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor. 4. Sidewall vertical ties can use 4' anchors in soil type 4B. Facing the home LEFTCORNER S. Homes requiring 4 Lock Down Anchor assemblies require the longitudinal and lateral strut on each anchor. All struts must be Installed towards the center of the home. Facing the home LEFT CORNER 6. Homes requiring 6 Lock Down Anchor assemblies only require longitudinal struts on the 4 corner positions. The two center positions only require a lateral strut. All struts must be installed towards the center of the home. Facing the home RIGHT CORNER Facing the home Facing the home CENTER RIGHT CORNER tudinal 7. The placement of the corner systems should be at a sidewall vertical tie that falls no more than 11' and no less than 5' from the end of the house on each corner. HOMEPRIDE NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED: Wind Zones 2 & 3 with roof pitch 6/12 or less. • Single or Double section homes 30'to 52 in length (excluding hitch) 4 • Single or Double section homes greater than 52'to 76' in length (excluding hitch) 6 NOTE: Roof pitches greater than 6/12 will require additional systems, contact Home Pride, Inc. for assistance. NOTE: Homes less than 30' — lack Down System should not be used. NOTE: Home manufacturers may provide a placement chart for specific models in their installation manual. The manufacturers placement chart supersedes the chart below. ANCHOR ASSEMBLY PLACEMENT Using 4 Anchor Assemblies Tr_TTITirM 1--jk� i�;��i i� Lock Down Anchor Assembly Components List 1. Ground Anchor with Strut Attachment Cap 2. Stabilizer 3. Lateral Strut 4. Longitudinal Strut S. Beam Clamp Assembly Lock Down Anchor Assembly Installation Instructions Using 6 Anchor Assemblies taF,tao— tata-ts_ The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor and align with a sldewall vertical strop. Install this anchor at a slight angle, not to exceed 15 degrees. This assembly Includes a stabilizer plate that is installed with the anchor and attached with a U-bolt and two nuts. The stabilizer plate should be driven Into the ground when the anchor is about 2/3 installed. Attach the stabilizer to the anchor shaft using the U-bolt and nuts then complete the Install of the anchor until the strut attachment cap is flush to the ground or slightly recessed into the ground, no more than X". The Strut Attachment Cap should be installed within %" or flush to the top of the stabilizer plate. (See illustration to the right.) NOTE: State of Florida allows a 2' pilot holes to be drilled to assist anchor Installation in extremely hard soil conditions. If this process Is used during installation of the Ground Anchor with Strut Attachment Cap the soil must be placed back in the pilot hole and compacted at 6" Intervals. This process should take place when the anchor is 8"-10" from fully installed —allowing room for the soil to be placed back in the pilot hole and properly packed. H 0M E"c''PRIDE 2. Once the ground anchor assembly is fully installed, attach longitudinal and lateral struts according to the diagram under anchor assembly placement (page 1.). The lateral arm fasteners are to be Installed tightly (nuts and bolts). The Beam Clamp assembly has two holes for the bolt and nut placement. Depending on the width of the beam, the corresponding hole should be used that pushes the front of the metal plate as close as possible to the upright of the beam. See the illustration on page 2, #5. Lateral struts should be installed in line with the center anchor head and attached at the top of the I-beam. Lateral strut angles must fall within 30 degree minimum - 60 degree maximum. Longitudinal strut angles must fall within 10 degree minimum -50 degree maximum. Longitudirul Strut Ana(hM Point Latml strut Attached Padnl Sldewaa ConreN.on F,r., LnngurdlrM Strut Aeazbed Palnt Atu,hed Point Side iStrap C—UP. After the Lock Down Anchor Assemblies have been fully Installed and all permiter anchors and straps fully installed and tightened —each strut has 4 self tapping screws that must be installed as the final step. Predrilled holes are provided on the outer strut Indicating placement. If the predrilled holes can not be accessed, install the screws as close to the predrilled holes as possible -making sure they are tapping into the Inner strut. The Lock Down Anchoring System should only be used for homes in the state of Florida. This anchoring system Is not designed, tested or approved for use In any other state. Contact Home Pride Inc. 276-466-0502 or at contactus@hoanchors.rom for any questions concering this product. Legacy Engineering listing # 113 Notes: PRODUCT WARRANTY Home Pride warrants its Lock Down Anchor System (HP LDS) against defects in workmanship and material at the site of Its Initial Installation. The HP LDS Is specifically designed and approved for use in the State of Florida. This product is not approved for use and should not be used outside the State of Florida. This product must not be reused or reinstalled at any other location. If used In violation of this Warranty or not Installed in accordance with installation Instructions, all written and Implied warranties are void and disclaimed. HP LDS products which are found to have defects will be replaced or repaired at Home Prlc e's option. This Express Warranty Is limited to replacement of product only and does not cover any labor or Installations costs. When the product is replaced, all Warranty rights are extinguished. This Warranty is only to the benefit of the original purchaser and Is not transferable. There are no other warranties (express or Implied) whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home Pride disclaims any and all other implied warranties, Including (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose to the extent allowed by law and any implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty. These limitations shall be enforceable to the extent permitted by law. HP LDS products which are examined and are found not to be defective will be returned to user and all costs associated with examination of the anchor product will be incurred by the user. The user is responsible for all maintenance of the HP LDS product Including regular monitoring of stability and Integrity of HP LDS products. For a warranty claim, contact your distributor or Home Pride Inc. at 15100 Industrial Park Road, Bristol, Virginia, 24202. 3. HOM E''s PRIOE VERTICAL VINYL SEIRTING ( Componentm & InStalletiwa ) WALL TOPFRONT Snaps Into to; back to hide screws and panel cuts TOP BACK . FLOOR Attached with 3/4" screws W apart VENTED PANEL 3.9 Incas per foot of ventilation f— BLOCK SUPPORT secured to top back and bottom rail with 3/4" acrews 16" o/c _ BOTTOM TRACK' Attached o group w T' galvanized nail Wok If sandy soil, than attach to ground 8.5" o/c *ALL PANELS ARE ACCESSIBLE BY REMOVING TOP FRONT AND PULLING UP ON PANEL Vinyl skirting installation Here's everything you'll need to add that finishing touch to any foundation. ASTCO Vinyl Skirting is engineered to fit together precisely, for a professional installation every time. Installation is quick and easy Before you begin your skirting installation, you will need to gather a few household tools: Hammer, chalk line, tape measure, fin snips or aviation snips, and plumb bob. 1. Install the vinyl ground channel directly under the outside 2. Install the back skirting trim. Snap a chalk line at the bottom of edge of your home, using galvanized nails. Use a plumb your home to mark the position for the back skirting trim. Nail the bob to determine exact location. trim pieces to the home using the nail slots. Make sure you place the nail in the center of the slot and do not hammer tightly. 3. To go around corners, bend the back skirting trim at the 4. Measure the skirting panels to the proper height, subtracting 114" comers of the home and continue nailing. Do not cut. for expansion. Cut the panels to sae, using tin snips. Slide panels over the back skirting him and Into the vinyl ground channel, Interlocking the panels as you install them. To form comers, bend but do not cut the panels. 5. Snap the front skirting trim into place to hold panels securely. To form comers, do not art the panels, notch and bend the panels. Follow the special guidelines shown in illustrations 6a and 6b to finish the skirting trim at the comers. rra• / 6. a) Cutting outside comers. Determine the location of the cor- ner and cut a 5118" section from the top edge of the spring lock. In the center, cut a "V° 314" deep and 1 118" wide at the top edge, and a small "V" cut at the bottom. Bend the front skirting trim and snap it into the comer. 6, b) Cutting inside comer To cut the front skirting trim for inside comers, cut out a 1" or 2" tab In the top edge of the spring lock and make a small "V" cut through the bottom lip. Bend and snap the trim piece into place: ABTCO.