Loading...
HomeMy WebLinkAboutEnergy CodeFORM R4Db-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BURNS ADDITION Builder Name: Street: 2805 N A1A Permit Office: ST LUCIE COUNTY APR 15 7111n City, State, Zip: FORT PIERCE, FL, Permit Number. Owner. Jurisdiction: ST LUCIE COUNTY Permitting Department Design Location: FL, Fart Pierce County. St. Lucie (Florida Climate Zone 2) St. Lucie County 1. New construction or eAsting Addition 9. Wall Types (430.0 scift.) Insulation Area 2. Single family or multiple family Single-family a.Frame - Wood, E)derior R=19.0 430.00 fF b. NIA R= ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms (Bedrns In Addition) 1(0) d. WA R= fF 10. Ceiling Types (204.0 sgft.) Insulation Area 5. Is this a worst case? No a Roof Deck (Unvented) R=20.0 204.00 ft' 6. Conditioned floor area above grade (ft') 204 b. WA R= ft' c. WA R= ft Conditioned floor area below grade 0 11. Ducts R ft' 7. Windows(37.8 so.) Description Area a. U-Factor. Dbl, default 20.00 ft' SHGC: Clear, default 12. Cooling systems kBtu/hr Efficiency b. U-Factor. Dbl, default 17.78 ft' a. Central Unit 9.0 SEER:18.00 SHGC: Clear, default c. U-Factor. WA ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 17.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.488 14. Hot water systems - a. Electric Tankless Cap: 1 gallons 8. Floor Types (204.0 sgft.) Insulation Area EF: 0.990 a Slab -On -Grade Edge Insulation R=0.0 204.00 fF b. Conservation features b. WA R= ft' None c. N/A R= ft' 15. Credits None 0.185 Total Proposed Modified Loads: 9.48 PASS Glass/Floor Area: Total Baseline Loads: 11.74 1 hereby certify that the plans and specifications covered by Review of the plans and o4111E SrgrR this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed =- r DATE: 4-8-2020- this building will be inspected for compliancewith Section 553.908 . g I hereby certify that this building, is in compliance Statutes. t 2d�,cl,Florida with the Florida Energy I OD wa fi OWNER/AGE T- BUILDING O MI DATE: DATE: - e - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH �(Rgq$ -I[ExceWiatt may apply) AEu ^0018 COMPLIANCE ST: LUCIE COUNTY 4/8/2020 9:34 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Comp iial Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BURNS ADDITION Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 204 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2805 N A1A Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/E6dsting: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp J Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 204 2040 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BATH 40 400 No 0 1 Yes Yes Yes 2 WIC 25 250 No 0 1 Yes Yes Yes 3 .BEDROOM 139 1390 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BATH 5 ft 0 40 ft' — 1 0 0 " 2SIab-On-Grade Edge Insulation WIC 3 ft 0 25 ft' — 1 0 0 3SIab-On-Grade Edge Insulation BEDROOM 35 ft 0 139 ft' — 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch J # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 208 ft0 ft' Light N 0.6 No 0.9 No 20 11.8 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 204 fF N N 4/8/2020 9:34 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2fl17 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 3 Under Attic(Unvented) Under Attic(Unvenled) Under Attic(Unvented) BATH 0 Blown WIC 0 Blown BEDROOM 0 Blown 40ft 0.1 Wood 25 ft2 0.1 Wood 139ft' 0.1 Wood WALLS it Omf Adjacent To WAII Type Space Cavity Width Height Sheathing Framing Solar Below _ 1 2 _ 3 _ 4 5 S N N E S E#edor Frame -Wood E)derior Frame -Wood 6derior Frame -Wood 6derior Frame -Wood E)derior Frame -Wood BATH 19 5 0 10 0 WIC 19 3 0 10 0 BEDROOM 19 11 0 10 0 BEDROOM 19 13 0 10 0 BEDROOM 19 11 0 10 0 50.0 ft' 0 0.1 0.6 30.0 ft' 0 0.1 0.6 110.0 ft' 0 0.1 0.6 130.0 fP 0 0.1 0.6 110.0 ft' 0 0.1 0.6 0 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 2 N 3 Metal Low-E Double E 4 Metal Low-E Double No 0.8 0.7 N 17.8 ft' No 1.01 0.3 N 20.0 ft' 2 ft 0 in 1 ft 4 in None 2 ft 0 in 1 ft 4 in None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 238 13.07 24.57 .1685 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/Supplemen Split Single HSPF:8.5 17 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flaw SHR Block Ducts 1 Central Unit/Supplemental for a Split Single SEER: 18 9 kBtu/hr 270 cfm 0.8 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless F)derior 0.99 1 gal 55.1 gal 120 deg None 4/a2020 9:34 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 F0RM R4n5-2n17 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' TEMPERATURES Programable[[T]]hermostat:: C[eilling Fans: �]]]N Heating H Jan Feb [[ jj [X] Mar ] E ]Ape [ ay,(X� ] M I) Jun [X] [ ]Jul �(( I Aug �C] ()Seep [ ] (r)(,) L 1 Oct Nov NovNo�ir Dec ()(�) Venting [[ 1) Jan [) l l Feb [[[b �X]l) Mar Ix) I( 1) [ 1 Jun [) Jul E 1 Aug L) Sep Lxl [X] [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft= 0 ft 0.3 BATH Defauk(8 lbs/sq.ft. fP ft 0.3 WIC Default Blbs/s .ft ft' ft 0.3 BEDROOM 4/812020 9:34 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4