Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION r Florida Department of Business and Professional Regulation - Residential Performance Method r 11 Project Name: Adams Homes - 3000 Model - 8116 Amalfi Circle Builder Name: Adams Homes Street: 8116 Amalfi Circle Permit Office: St. Lucie County City, Slate, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Adams Homes - 3000 Model Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2254.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1920.70 ft' b. Frame - Wood, Adjacent R=13.0 334.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (3000.0 sgfL) Insulation Area a. Under Attic (Vented) R=30.0 3000.00 ft' 6. Conditioned floor area above grade (ft� 3000 b. NIA R= ft' Conditioned floor area below grade (ft� 0 c. NIA R= ft' 11. Ducts R ft' 7. Wmdows(252.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 6 115 a. U-Factor: Sgl, U=0.33 192.00 ft' . SHGC: SHGC=0.23 b. U-Factor: SgI, U=0.33 60.67 ft' 12. Cooling systems kBlu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 47.0 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft' a. Electric Heat Pump 47.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.356 ft. Area Weighted Average SHGC: 0.225 14. Hot water systems 8. Floor Types (3000.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft' b. Conservation features EF: 0.950 b. NIA R= ft' None c. N/A R= ft' 15. Credits CF, Patel Glass/Floor Area: 0.084 Total Proposed Modified Loads: 80.69 PASS SS Total Baseline Loads: 83.62 1 hereby certify that the plans and specifications covered by Review of the plans and S7yl� this calculation are in compliance with the Florida Energy specifications covered by this QTHg Code. calculation indicates compliance y��Sy�' with the Florida Energy Code. E. PREPARED BY: Before construction is completed 0 DATE: - - this building will be inspected for 6 C7 to i', a compliance with Section 553.908 u . a I hereby certify that this building, as designed, is in compliance Florida Statutes. !,� with the Florida "&rgy6s ems"' �'Op W f OWNER/AGENT" C,�= BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/26/2020 7:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software SO 10V Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT rretitle: Adams Homes - 3000 Model - Bedrooms: 4 Address Type: Street Address 6vilding Type: User Conditioned Area: 3000 Lot # Owner Name: Adams Homes - 3000 Model Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: ' Builder Name: Adams Homes Rotate Angle: 0 Street: 8116 Amalfi Circle Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 3000 26062.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Laundry Room 81 648 No 0 1 Yes Yes Yes 2 Pantry 54 432 No 0 1 Yes Yes Yes 3 Kitchen 333 2664 Yes 1 1 Yes Yes Yes 4 Nook 132 1056 No 0 1 Yes Yes Yes 5 Family Room 396 4078.8 'No 2 1 Yes Yes Yes 6 Dining Room 198 2039.4 No 1 1 No Yes Yes 7 Foyer 82 656 No 0 1 Yes Yes Yes 8 Living Room 150 1500 No 1 1 Yes Yes Yes 9 Owners Suite 396 3564 No 2 1 1 Yes Yes Yes 10 WIC 58 464 No 0 1 Yes Yes Yes 11 Owners Bath 172 1376 No 0 1 Yes Yes Yes 12 Toilet 32 256 No 0 1 Yes Yes Yes 13 AHU 24 192 No 0 1 No Yes Yes 14 Bath 3 54 432 No 0 1 No Yes Yes 15 Bedroom 3 189 1512 No 1 1 1 Yes Yes Yes 16 Bedroom 2 172 1376 No 1 1 1 Yes Yes Yes 17 WIC 2 36 288 No 0 1 Yes Yes Yes 18 Bath 2 54 432 No 0 1 Yes Yes Yes 19 Bedroom 4 177 1416 No 1 1 1 Yes Yes Yes 20 Hall 210 1680 No 0 1 No Yes Yes 2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Laundry Room 18 ft 81 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulatio Pantry 6 ft 54 ft' -_ 1 0 0 3 Slab -On -Grade Edge Insulatio Kitchen 15 It 333 ft2 __ 1 0 0 48Iab-On-Grade Edge Insulatio Nook 11 ft 132 ft' 1 0 0 5 Slab -On -Grade Edge Insulatio Family Room 18 ft 396 ft' 1 0 0 6 Slab -On -Grade Edge Insulatio Dining Room 1 ft 198 ft2 __ 1 0 0 7 Slab -On -Grade Edge Insulatio Foyer 7 ft 82 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Living Room 15 ft 150 ft' __ 1 0 0 9 Slab -On -Grade Edge Insulatio Owners Suite 18 ft 396 ft2 _- 1 0 0 10Slab-On-Grade Edge Insulatio WIC 17 ft 58 ft' ___ 1 0 0 11Slab-On-Grade Edge Insulatio Owners Bath 17 ft 172 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulatio Toilet 12 ft 32 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulatio AHU 1 ft 24 ft2 _ 1 0 0 14Slab-On-Grade Edge Insulatio Bath 3 1 ft 54 ft' ___ 1 0 0 15SIab-On-Grade Edge Insulatio Bedroom 3 28 ft 189 ft' — 1 0 0 16Slab-On-Grade Edge Insulatio Bedroom 2 27 ft 172 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulatio WIC 2 6 ft 36 ft2 _ 1 0 0 18SIab-On-Grade Edge Insulatio Bath 2 6 ft 54 ft2 1 0 0 19Slab-On-Grade Edge Insulatio Bedroom 4 13 ft 177 ft' -_ 1 0 0 20Slab-On-Grade Edge Insulatio Hall 1 ft 210 ft' ___ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 3355 ft' 752 ft' Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3000 ft2 N N 2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Laundry Room 30 Blom 81111 0.1 Wood 2 Under Attic (Vented) Pantry 30 Blown 54 ft' 0.1 Wood 3 Under Attic (Vented) Kitchen 30 Blown 333 ft' 0.1 Wood 4 Under Attic (Vented) Nock 30 Blown 132 ft' 0.1 Wood 5 Under Attic (Vented) Family Room 30 Blown 396 ft' 0 Wood 6 Under Attic (Vented) Dining Room 30 Blown 198 ft' 0 Wood 7 Under Attic (Vented) Foyer 30 Blown 82 ft' 0.1 Wood 8 Under Attic (Vented) Living Room 30 Blown 150 ft' 0.1 Wood 9 Under Attic (Vented) Owners Suite 30 Blown 396 ft' 0.1 Wood 10 Under Attic (Vented) WIC 30 Blown 58 ft' 0.1 Wood 11 Under Attic (Vented) Owners Bath 30 Blown 172 ft' 0.1 Wood 12 Under Attic (Vented) Toilet 30 Blown 32 ft' 0.1 Wood 13 Under Attic (Vented) AHU 30 Blown 24 ft2 0.1 Wood 14 Under Attic (Vented) Bath 3 30 Blown 54 ft' 0.1 Wood 15 Under Attic (Vented) Bedroom 3 30 Blown 189 ft2 0.1 Wood 16 Under Attic (Vented) Bedroom 2 30 Blown 172 ft' 0.1 Wood 17 Under Attic (Vented) WIC 30 Blown 36 ft' 0.1 Wood 18 Under Attic (Vented) Bath 2 30 Blown 54 ft2 0.1 Wood 19 Under Attic (Vented) Bedroom 4 30 Blown 177 ft' 0.1 Wood 20 Under Attic (Vented) Hall 30 Blown 210 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE Exterior Concrete Block - Ext Inslubundry, Roo 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 _ 2 SE Exterior Concrete Block - Ext InsluBundry Roo 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 3 NE Exterior Concrete Block - Ext Insul Pantry 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 -4 NE Exterior Concrete Block - Ext Insul Kitchen 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 _ 5 SE Exterior Concrete Block - Ext Insul Nook 4.1 11 0 8 0 88.0 fF 0 0 0.6 0 _ 6 SE Exterior Concrete Black - Ext InSeAmily Room 4.1 14 0 10 4 144.7 ft2 0 0 0.6 0 _ 7 NW Exterior Concrete Block - Ext Insul Foyer 4.1 7 0 8 0 56.0 ft' 0 0 0.6 0 _ 8 SW Exterior Concrete Block - Ext Insliving Room 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 9 NW Exterior Concrete Block - Ext Insliving Room 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 10 SW Exterior Concrete Block - Ext InsQWners Suite 4.1 18 0 9 0 162.0 ft2 0 0 0.6 0 _ 11 NE Exterior Concrete Block - Ext Insul WIC 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 _ 12 BE Exterior Concrete Block- Ext Insul WIC 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 13 SE Exterior Concrete Block - Ext InsOlvners Bath 4.1 9 0 8 0 72.0 R2 0 0 0.6 0 _ 14 SW Exterior Concrete Block - Ext InsUivners Bath 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 _ 15 SE Exterior Concrete Block - Ext Insul Toilet 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 _ 16 SW Exterior Concrete Block - Ext Insul Toilet 4.1 4 0 8 0 32.0 ft' 0 0 0.6 0 _ 17 NE Exterior Concrete Block - Ext InsiBedroom 3 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 18 NW Exterior Concrete Block - Ext InstHedroom 3 4.1 12 0 8 0 96.0 112 0 0 0.6 0 19 SW Exterior Concrete Block - Ext lnsiBedroom 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 20 NW Exterior Concrete Block - Ext InsdItedroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 2/26/2020 7:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent T, Wall Type21 Space Cavity Width Height Sheathing Framing Solar Below SW Exterior Concrete Block - Exl Insul WIC 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 22 SW Exterior Concrete Block - Exl Insul Bath 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 23 SW Exterior Concrete Block - Exl InsiBedroom 4 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 24 NW Garage Frame - Wood Kitchen 13 20 8 160.0 ft2 0.23 0.6 0 25 NE Garage Frame - Wood Dining Room 13 3 8 24.0 ft2 0.23 0.6 0 26 NE Garage Frame - Wood Living Room 13 15 10 150.0 ft2 0.23 0.6 0 DOORS # Dint Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Wood Laundry Roo None .39 2 10 6 10 19.4 ft2 2 SE Wood Family Room None .39 2 10 6 10 19.3 ft2 3 NW Wood Foyer None .39 3 6 10 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 4 Vinyl Low-E Single Yes 0.33 0.23 N 18.0 ft2 2 ft 0 in 0 ft 5 in None None 2 SE 5 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft2 2 ft 0 in 0 ft 5 in None None 3 SE 6 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft2 10 ft 0 in 0 ft 5 in None None 4 NW 7 Vinyl Low-E Single Yes 0.33 0.21 N 6.8 ft2 5 It 0 in 1 ft 0 in None None 5 NW 7 Vinyl Low-E Single Yes 0.33 0.21 N 27.3 ft2 5 ft 0 in 1 It 0 in None None 6 NW 9 Vinyl Low-E Single Yes 0.33 0.21 N 8.5 ft- 2 ft 0 in 1 ft 0 in None None 7 NW 9 Vinyl Low-E Single Yes 0.33 0.21 N 18.0 ft2 2 ft 0 in 1 ft 0 in None None 8 SW 10 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft2 2 ft 0 in 0 ft 5 in None None 9 SE 15 Vinyl Low-E Single Yes 0.33 0.23 N 9.0 ft2 2 It 0 in 0 It 5 in None None 10 NW 18 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 ft2 2 ft 0 in 0 ft 1 in None None i t NW 20 Vinyl Low-E Single Yes 0.33 0.23 N 30.0 112 2 ft 0 in 0 ft 1 in None None 12 SW 23 Vinyl Low-E Single Yes 0.33 0.23 N 15.0 ft2 2 It 0 in 0 It 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 480 ft2 480 ft2 38 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 3040.6 166.92 313.93 .1384 7 2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 47 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 47 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS —Supply-- —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 115 ft' Attic 20 ft' Default Leakage AHU (Default) (Default) 1 1 TEMPERATURES Programablfe Thermosta[[t:]]Y Ceiling Fans: Heatiov ng rXj] Mar Jan [X] Feb [j jj r l.� Apr f y(X) Jun ri Jul May f rl Aug t[[ ]] JXl Sep j Oct tp�' Nov Dec Dec Venting ( l l Jan ll 111 Feb [[[[�XXXIIII Mar lXl ll�xll ([ 1] Jun 111 Jul 111 Aug � l Sep l [X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Healing (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Laundry Room Default(8 lbs/sq.ft. ft2 ft 0.3 Pantry Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 ft 0.3 Nook Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Room Default(8 lbs/sq.ft. ft2 ft 0.3 Foyer Default(81bs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibslsq.ft. ft2 ft 0.3 Owners Suite Default(8 lbs/sq.ft. 112 ft 0.3 WIC Default(8 lbslsq.R. ft2 ft 0.3 Owners Bath Default(8 lbslsq.ft. ft2 ft 0.3 Toilet Default(8 lbs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 lbslsq.ft. ft2 ft 0.3 Bedroom 2 Default(8 lbslsq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq. t. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 lbs/s.ft. ft2 ft 0.3 Hall 2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 ' 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 47.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3000 d) Room uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.225 14. Heating system: Capacity 47.0 c) Area 7c. 252.7 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 1OA1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatnra � � Date: Address of New Home: 8116 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951 2/26/2020 7:56:11 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1