HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
r Florida Department of Business and Professional Regulation - Residential Performance Method
r
11 Project Name: Adams Homes - 3000 Model - 8116 Amalfi Circle
Builder Name: Adams Homes
Street: 8116 Amalfi Circle
Permit Office: St. Lucie County
City, Slate, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner: Adams Homes - 3000 Model
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2254.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1920.70 ft'
b. Frame - Wood, Adjacent
R=13.0 334.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (3000.0 sgfL)
Insulation Area
a. Under Attic (Vented)
R=30.0 3000.00 ft'
6. Conditioned floor area above grade (ft� 3000
b. NIA
R= ft'
Conditioned floor area below grade (ft� 0
c. NIA
R= ft'
11. Ducts
R ft'
7. Wmdows(252.7 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 115
a. U-Factor: Sgl, U=0.33 192.00 ft'
.
SHGC: SHGC=0.23
b. U-Factor: SgI, U=0.33 60.67 ft'
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
47.0 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ft'
a. Electric Heat Pump
47.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.356 ft.
Area Weighted Average SHGC: 0.225
14. Hot water systems
8. Floor Types (3000.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft'
b. Conservation features
EF: 0.950
b. NIA R= ft'
None
c. N/A R= ft'
15. Credits
CF, Patel
Glass/Floor Area: 0.084 Total Proposed Modified Loads: 80.69
PASS
SS
Total Baseline
Loads: 83.62
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7yl�
this calculation are in compliance with the Florida Energy
specifications covered by this
QTHg
Code.
calculation indicates compliance
y��Sy�'
with the Florida Energy Code.
E.
PREPARED BY:
Before construction is completed
0
DATE: - -
this building will be inspected for
6
C7 to i', a
compliance with Section 553.908
u
. a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,�
with the Florida "&rgy6s ems"'
�'Op W f
OWNER/AGENT" C,�=
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/26/2020 7:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software
SO
10V
Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
rretitle:
Adams Homes - 3000 Model -
Bedrooms:
4
Address Type:
Street Address
6vilding Type:
User
Conditioned Area:
3000
Lot #
Owner Name:
Adams Homes - 3000 Model
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
' Builder Name:
Adams Homes
Rotate Angle:
0
Street:
8116 Amalfi Circle
Permit Office:
St. Lucie County
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan:
No
City, State,
Zip:
Fort Pierce ,
Family Type:
Single-family
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
3000
26062.2
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
Laundry Room
81
648 No
0
1
Yes
Yes
Yes
2
Pantry
54
432 No
0
1
Yes
Yes
Yes
3
Kitchen
333
2664 Yes
1
1
Yes
Yes
Yes
4
Nook
132
1056 No
0
1
Yes
Yes
Yes
5
Family Room
396
4078.8 'No
2
1
Yes
Yes
Yes
6
Dining Room
198
2039.4 No
1
1
No
Yes
Yes
7
Foyer
82
656 No
0
1
Yes
Yes
Yes
8
Living Room
150
1500 No
1
1
Yes
Yes
Yes
9
Owners Suite
396
3564 No
2
1
1
Yes
Yes
Yes
10
WIC
58
464 No
0
1
Yes
Yes
Yes
11
Owners Bath
172
1376 No
0
1
Yes
Yes
Yes
12
Toilet
32
256 No
0
1
Yes
Yes
Yes
13
AHU
24
192 No
0
1
No
Yes
Yes
14
Bath 3
54
432 No
0
1
No
Yes
Yes
15
Bedroom 3
189
1512 No
1
1
1
Yes
Yes
Yes
16
Bedroom 2
172
1376 No
1
1
1
Yes
Yes
Yes
17
WIC 2
36
288 No
0
1
Yes
Yes
Yes
18
Bath 2
54
432 No
0
1
Yes
Yes
Yes
19
Bedroom 4
177
1416 No
1
1
1
Yes
Yes
Yes
20
Hall
210
1680 No
0
1
No
Yes
Yes
2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Laundry Room 18 ft
81 ft2
___
1
0
0
2 Slab -On -Grade Edge Insulatio
Pantry
6 ft
54 ft'
-_
1
0
0
3 Slab -On -Grade Edge Insulatio
Kitchen
15 It
333 ft2
__
1
0
0
48Iab-On-Grade Edge Insulatio
Nook
11 ft
132 ft'
1
0
0
5 Slab -On -Grade Edge Insulatio
Family Room
18 ft
396 ft'
1
0
0
6 Slab -On -Grade Edge Insulatio
Dining Room
1 ft
198 ft2
__
1
0
0
7 Slab -On -Grade Edge Insulatio
Foyer
7 ft
82 ft2
1
0
0
8 Slab -On -Grade Edge Insulatio
Living Room
15 ft
150 ft'
__
1
0
0
9 Slab -On -Grade Edge Insulatio
Owners Suite
18 ft
396 ft2
_-
1
0
0
10Slab-On-Grade Edge Insulatio
WIC
17 ft
58 ft'
___
1
0
0
11Slab-On-Grade Edge Insulatio
Owners Bath
17 ft
172 ft2
___
1
0
0
12SIab-On-Grade Edge Insulatio
Toilet
12 ft
32 ft2
___
1
0
0
13SIab-On-Grade Edge Insulatio
AHU
1 ft
24 ft2
_
1
0
0
14Slab-On-Grade Edge Insulatio
Bath 3
1 ft
54 ft'
___
1
0
0
15SIab-On-Grade Edge Insulatio
Bedroom 3
28 ft
189 ft'
—
1
0
0
16Slab-On-Grade Edge Insulatio
Bedroom 2
27 ft
172 ft2
____
1
0
0
17SIab-On-Grade Edge Insulatio
WIC 2
6 ft
36 ft2
_
1
0
0
18SIab-On-Grade Edge Insulatio
Bath 2
6 ft
54 ft2
1
0
0
19Slab-On-Grade Edge Insulatio
Bedroom 4
13 ft
177 ft'
-_
1
0
0
20Slab-On-Grade Edge Insulatio
Hall
1 ft
210 ft'
___
1
0
0
ROOF
/
Roof
Gable Roof
Red
Solar SA Emitt
Emitt
Deck
Pitch
V
# Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Composition shingles 3355 ft'
752 ft' Medium
N
0.6 No 0.9
No
0
26.6
ATTIC
/
V
# Type
Ventilation
Vent
Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
300 3000 ft2
N N
2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) Laundry Room
30
Blom
81111
0.1
Wood
2
Under Attic (Vented) Pantry
30
Blown
54 ft'
0.1
Wood
3
Under Attic (Vented) Kitchen
30
Blown
333 ft'
0.1
Wood
4
Under Attic (Vented) Nock
30
Blown
132 ft'
0.1
Wood
5
Under Attic (Vented) Family Room
30
Blown
396 ft'
0
Wood
6
Under Attic (Vented) Dining Room
30
Blown
198 ft'
0
Wood
7
Under Attic (Vented) Foyer
30
Blown
82 ft'
0.1
Wood
8
Under Attic (Vented) Living Room
30
Blown
150 ft'
0.1
Wood
9
Under Attic (Vented) Owners Suite
30
Blown
396 ft'
0.1
Wood
10
Under Attic (Vented) WIC
30
Blown
58 ft'
0.1
Wood
11
Under Attic (Vented) Owners Bath
30
Blown
172 ft'
0.1
Wood
12
Under Attic (Vented) Toilet
30
Blown
32 ft'
0.1
Wood
13
Under Attic (Vented) AHU
30
Blown
24 ft2
0.1
Wood
14
Under Attic (Vented) Bath 3
30
Blown
54 ft'
0.1
Wood
15
Under Attic (Vented) Bedroom 3
30
Blown
189 ft2
0.1
Wood
16
Under Attic (Vented) Bedroom 2
30
Blown
172 ft'
0.1
Wood
17
Under Attic (Vented) WIC
30
Blown
36 ft'
0.1
Wood
18
Under Attic (Vented) Bath 2
30
Blown
54 ft2
0.1
Wood
19
Under Attic (Vented) Bedroom 4
30
Blown
177 ft'
0.1
Wood
20
Under Attic (Vented) Hall
30
Blown
210 ft'
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 1
NE
Exterior Concrete Block - Ext Inslubundry, Roo
4.1
9
0 8
0
72.0 ft'
0
0
0.6
0
_ 2
SE
Exterior Concrete Block - Ext InsluBundry Roo
4.1
9
0 8
0
72.0 ft'
0
0
0.6
0
3
NE
Exterior Concrete Block - Ext Insul Pantry
4.1
6
0 8
0
48.0 ft'
0
0
0.6
0
-4
NE
Exterior Concrete Block - Ext Insul Kitchen
4.1
15
0 8
0
120.0 ft'
0
0
0.6
0
_ 5
SE
Exterior Concrete Block - Ext Insul Nook
4.1
11
0 8
0
88.0 fF
0
0
0.6
0
_ 6
SE
Exterior Concrete Black - Ext InSeAmily Room
4.1
14
0 10
4
144.7 ft2
0
0
0.6
0
_ 7
NW
Exterior Concrete Block - Ext Insul Foyer
4.1
7
0 8
0
56.0 ft'
0
0
0.6
0
_ 8
SW
Exterior Concrete Block - Ext Insliving Room
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
_ 9
NW
Exterior Concrete Block - Ext Insliving Room
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
10
SW
Exterior Concrete Block - Ext InsQWners Suite
4.1
18
0 9
0
162.0 ft2
0
0
0.6
0
_ 11
NE
Exterior Concrete Block - Ext Insul WIC
4.1
12
0 8
0
96.0 ft2
0
0
0.6
0
_ 12
BE
Exterior Concrete Block- Ext Insul WIC
4.1
5
0 8
0
40.0 ft2
0
0
0.6
0
_ 13
SE
Exterior Concrete Block - Ext InsOlvners Bath
4.1
9
0 8
0
72.0 R2
0
0
0.6
0
_ 14
SW
Exterior Concrete Block - Ext InsUivners Bath
4.1
8
0 8
0
64.0 ft'
0
0
0.6
0
_ 15
SE
Exterior Concrete Block - Ext Insul Toilet
4.1
8
0 8
0
64.0 ft'
0
0
0.6
0
_ 16
SW
Exterior Concrete Block - Ext Insul Toilet
4.1
4
0 8
0
32.0 ft'
0
0
0.6
0
_ 17
NE
Exterior Concrete Block - Ext InsiBedroom 3
4.1
16
0 8
0
128.0 ft2
0
0
0.6
0
_ 18
NW
Exterior Concrete Block - Ext InstHedroom 3
4.1
12
0 8
0
96.0 112
0
0
0.6
0
19
SW
Exterior Concrete Block - Ext lnsiBedroom 2
4.1
16
0 8
0
128.0 ft'
0
0
0.6
0
20
NW
Exterior Concrete Block - Ext InsdItedroom 2
4.1
11
0 8
0
88.0 ft2
0
0
0.6
0
2/26/2020 7:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
T, Wall
Type21
Space
Cavity Width
Height
Sheathing Framing
Solar Below
SW
Exterior
Concrete Block - Exl Insul WIC 2
4.1 6
0
8 0
48.0 ft2
0
0
0.6
0
22
SW
Exterior
Concrete Block - Exl Insul Bath 2
4.1 6
0
8 0
48.0 ft2
0
0
0.6
0
23
SW
Exterior
Concrete Block - Exl InsiBedroom 4
4.1 13
0
8 0
104.0 ft2
0
0
0.6
0
24
NW
Garage
Frame - Wood
Kitchen
13 20
8
160.0 ft2
0.23
0.6
0
25
NE
Garage
Frame - Wood
Dining Room
13 3
8
24.0 ft2
0.23
0.6
0
26
NE
Garage
Frame - Wood
Living Room
13 15
10
150.0 ft2
0.23
0.6
0
DOORS
#
Dint
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SE
Wood
Laundry Roo
None
.39
2
10
6 10
19.4 ft2
2
SE
Wood
Family Room
None
.39
2
10
6 10
19.3 ft2
3
NW
Wood
Foyer
None
.39
3
6 10
20.5 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame
Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 4
Vinyl
Low-E Single
Yes
0.33 0.23
N
18.0 ft2
2 ft 0 in
0 ft 5 in
None
None
2
SE 5
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
2 ft 0 in
0 ft 5 in
None
None
3
SE 6
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
10 ft 0 in
0 ft 5 in
None
None
4
NW 7
Vinyl
Low-E Single
Yes
0.33 0.21
N
6.8 ft2
5 It 0 in
1 ft 0 in
None
None
5
NW 7
Vinyl
Low-E Single
Yes
0.33 0.21
N
27.3 ft2
5 ft 0 in
1 It 0 in
None
None
6
NW 9
Vinyl
Low-E Single
Yes
0.33 0.21
N
8.5 ft-
2 ft 0 in
1 ft 0 in
None
None
7
NW 9
Vinyl
Low-E Single
Yes
0.33 0.21
N
18.0 ft2
2 ft 0 in
1 ft 0 in
None
None
8
SW 10
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
2 ft 0 in
0 ft 5 in
None
None
9
SE 15
Vinyl
Low-E Single
Yes
0.33 0.23
N
9.0 ft2
2 It 0 in
0 It 5 in
None
None
10
NW 18
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 ft2
2 ft 0 in
0 ft 1 in
None
None
i t
NW 20
Vinyl
Low-E Single
Yes
0.33 0.23
N
30.0 112
2 ft 0 in
0 ft 1 in
None
None
12
SW 23
Vinyl
Low-E Single
Yes
0.33 0.23
N
15.0 ft2
2 It 0 in
0 It 5 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
480 ft2
480 ft2
38 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000386
3040.6 166.92
313.93
.1384
7
2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
47 kBlu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15
47 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft.
DUCTS
—Supply--
—Return
Air
CFM 25 CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heat Cool
1
Attic 6 115 ft'
Attic
20 ft' Default Leakage
AHU
(Default) (Default)
1 1
TEMPERATURES
Programablfe Thermosta[[t:]]Y
Ceiling Fans:
Heatiov
ng
rXj] Mar
Jan [X] Feb
[j jj r
l.� Apr
f
y(X) Jun ri Jul
May
f
rl Aug
t[[ ]]
JXl Sep
j
Oct
tp�'
Nov
Dec
Dec
Venting (
l
l Jan ll 111 Feb [[[[�XXXIIII Mar
lXl
ll�xll
([ 1] Jun 111 Jul
111 Aug
�
l Sep l
[X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78 78
78
78
78
PM 78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
66
66
Healing (WEH)
AM 66
66 66
66 66 68
68
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
66
66
2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Laundry Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft2
ft
0.3
Nook
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Family Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Foyer
Default(81bs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibslsq.ft.
ft2
ft
0.3
Owners Suite
Default(8 lbs/sq.ft.
112
ft
0.3
WIC
Default(8 lbslsq.R.
ft2
ft
0.3
Owners Bath
Default(8 lbslsq.ft.
ft2
ft
0.3
Toilet
Default(8 lbs/sq.ft.
ft2
ft
0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 lbslsq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 lbslsq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq. t.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 4
Default(8 lbs/s.ft.
ft2
ft
0.3
Hall
2/26/2020 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
' 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
AHU
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
47.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 3000
d) Room uniVPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.330
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.225
14. Heating system: Capacity
47.0
c) Area
7c. 252.7
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
1OA1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed
code compliant features.
Builder Signatnra � �
Date:
Address of New Home: 8116 Amalfi Circle
City/FL Zip: Fort Pierce, FL 34951
2/26/2020 7:56:11 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1