HomeMy WebLinkAboutGenerator Transfer Switch SpecsGENERAL Service and non -Service rated Automatic Transfer Switches 100 - 400 Amps, Single Phase C(S) us LISTED �th,LU ,-q 0o 11< ad ,p wm, `CUL only applias to non -service rated switches DESCRIPTION Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution"' or Nexus Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. STANDARD FEATURES Service rated (RTST) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service, The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RTSP) switches are housed in a steel enclosure. so s24x8 100-400 Amps, Single Phase All timing and sensing functions originate in the generator controller GENERAC' Automatic Transfer Switches Utility 9 r ................................•.. 0 second factory set. adjustable between 2 1500 seconds by a qualified dealer' Timer to generators start.................................................................... 5 seconds Engine warm up delay ............................................. ........ ...... . .... .._. . ..... .. ._...........60°for 5 seconds Standby voltage sensor........................................................... ......... .�� 80°r� ... Utility voltage pickup ........................................................................................................................... ............ 15 seconds Re -transfer time delay.................................................................................................... ...................... . 60 seconds Engine cool -down timer ...... ....... .... ............................................................... ... ..... ............................__............ . .. ........ 12 minutes every 7 days Exerciser........................................................................................................................................................... 300 The transfer switch can be operated manually without power applied. 400 When used In conjunction with units utilizing Evolution" controls w �� Dimensions Model RTSP10oA3 RTST100A3 RTST10OA3 RTST150A3 RTSP200A3 RTST200A3 RTST300A3 RTSP400A3 RTST40OA3 26.75/679.41 RTSP100A3 100 150 200 200 300 400 400 201508 I 00 120/240, to 120/240.10 120/240.10 120/240,10 120/240.10 120/240 10 120/240,10 � 10.5/266.7 120/240,10 Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Se vice Rated Open Transition Service Rated Open Transition In pen Transition n Service RTa nsated ition Type c) r(Automatic) Open Transition NEMA/UL 3R NEMA/UL 3RNEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R Type NEMA'UL 3R UL UL UL/CUL UL UL UL/CUL ULpe UUCUL 10,000 22.000 10.000 22,000 22.000 22.000 22. Rating000 (Amps) 10,000 #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Lug Range 1,0 Dimensions Model RTSP10oA3 RTST100A3 RTST150A3iP,TSP200A3i, RTST200A3 RTST3o0A3I,RTSP400A3 RTST400A3 Height H1 17.24/437:9 17.24/437.9, 26.75/679.41 17.24/437.9 l 26.75/679.4 42.91/1089.9131.25/793.8',42.91/1089.9 H2 20/508 I 20/508 30/762 i 201508 I 30/762 4811219.2 36i914.4 48,,t219.2 Width W1 12.51317.5 � 12.5/317.5 10.5!266.7 1 12.5/317.5 � 10.5/266.7 16.69/423.9 ` 19.18/487.2 ,16.6914239 (in./mm) . W2 4.6/370.8 I 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 121.82!554.2 24/609.6 21.82/55421 Depth (In./mm) 7.09/180.1 7.09/180.1 6.3/160.1 1 7.09/180.1 �I, 6.3/160.1 10.06/255.5 � 10.06/255.5 10.06I255 5 Me ght (lbsAilos) 20/9.07 i 22.5/10.21 39/17.69 2019.07 39/17.69 140/635 33160.33 1z0,U.5 GEN ERAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com Cb2015 Gen erac Power Systems. Inc. All rights reserved. All specifications are subjec, to change without notice. Bulletin 0198240SBY-J Printed in U.S.A. 04i17r 15