HomeMy WebLinkAboutGenerator Transfer Switch SpecsGENERAL
Service and non -Service rated
Automatic Transfer Switches
100 - 400 Amps, Single Phase
C(S) us
LISTED �th,LU ,-q 0o 11<
ad ,p wm,
`CUL only applias to non -service rated switches
DESCRIPTION
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution"' or Nexus
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
STANDARD FEATURES
Service rated (RTST) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service, The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
Non -service rated (RTSP) switches are housed in a steel enclosure.
so
s24x8
100-400 Amps, Single Phase
All timing and sensing functions originate in the generator controller
GENERAC'
Automatic Transfer Switches
Utility 9 r ................................•..
0 second factory set. adjustable between 2 1500 seconds by a qualified dealer'
Timer to generators start....................................................................
5 seconds
Engine warm up delay .............................................
........ ...... . .... .._. . ..... .. ._...........60°for 5 seconds
Standby voltage sensor...........................................................
......... .�� 80°r�
...
Utility voltage pickup ...........................................................................................................................
............ 15 seconds
Re -transfer time delay....................................................................................................
...................... .
60 seconds
Engine cool -down timer ...... ....... .... ...............................................................
... ..... ............................__............ .
.. ........ 12 minutes every 7 days
Exerciser...........................................................................................................................................................
300
The transfer switch can be operated manually without power applied.
400
When used In conjunction with units utilizing Evolution" controls
w ��
Dimensions
Model RTSP10oA3
RTST100A3
RTST10OA3
RTST150A3
RTSP200A3
RTST200A3
RTST300A3
RTSP400A3
RTST40OA3
26.75/679.41
RTSP100A3
100
150
200
200
300
400
400
201508 I
00
120/240, to
120/240.10
120/240.10
120/240,10
120/240.10
120/240 10
120/240,10
� 10.5/266.7
120/240,10
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Se vice Rated
Open Transition
Service Rated
Open Transition
In
pen Transition
n
Service RTa nsated
ition Type
c)
r(Automatic)
Open Transition
NEMA/UL 3R
NEMA/UL 3RNEMA/UL
3R
NEMA/UL 3R
NEMA/UL 3R
NEMA/UL 3R
NEMA/UL 3R
Type
NEMA'UL 3R
UL
UL
UL/CUL
UL
UL
UL/CUL
ULpe
UUCUL
10,000
22.000
10.000
22,000
22.000
22.000
22.
Rating000
(Amps)
10,000
#14
250 MCM - #6
600 MCM
- #4 or 1/0 - 250
MCM
Lug Range
1,0
Dimensions
Model RTSP10oA3
RTST100A3
RTST150A3iP,TSP200A3i,
RTST200A3
RTST3o0A3I,RTSP400A3
RTST400A3
Height
H1 17.24/437:9
17.24/437.9,
26.75/679.41
17.24/437.9 l
26.75/679.4
42.91/1089.9131.25/793.8',42.91/1089.9
H2
20/508
I 20/508
30/762 i
201508 I
30/762
4811219.2 36i914.4 48,,t219.2
Width
W1
12.51317.5
� 12.5/317.5
10.5!266.7 1
12.5/317.5
� 10.5/266.7
16.69/423.9 ` 19.18/487.2 ,16.6914239
(in./mm)
.
W2
4.6/370.8
I
14.6/370.8
13.5/342.9
14.6/370.8
13.5/342.9
121.82!554.2 24/609.6 21.82/55421
Depth (In./mm)
7.09/180.1
7.09/180.1
6.3/160.1
1 7.09/180.1
�I, 6.3/160.1
10.06/255.5
�
10.06/255.5 10.06I255 5
Me ght (lbsAilos)
20/9.07
i
22.5/10.21
39/17.69
2019.07 39/17.69
140/635
33160.33 1z0,U.5
GEN ERAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
Cb2015 Gen erac Power Systems. Inc. All rights reserved. All specifications are subjec, to change without notice. Bulletin 0198240SBY-J Printed in U.S.A. 04i17r 15