HomeMy WebLinkAboutEnergy CodeRECEIVED
FORM R405-2017 FEB 19020
FLORIDA ENERGY E _ _ FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 5703 Hickory Drive Energygauge
Builder Name: Habitat for Humanity
Street' 5703 Hickory Drive
Permit Office:
City, State, Zip: Ft. Pierce , FL,
Permit Number:
Owner: Joseph W. Gianna
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1328.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=3.0 1092.00 112
b. Concrete Block - Int Insul, Adjacent
R=3.0 236.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst rase? No
10. Ceiling Types (1338.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1338.00 112
6. Conditioned floor area above grade (ft2) 1335
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(118.6 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 267
a. U-Factor: Dbl, U=0.66 118.62 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC:
a. Central Unit
27.6 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBlu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heal,
27.3 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.252 ft.
Area Weighted Average SHGC: - 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1335.3 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1335.30 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
OF
Glass/Floor Area: 0.089 Total Proposed Modified Loads: 46.53
PASS
Total Baseline Loads: 46.87
I hereby certify that the plans and specifications covered by
Review of the plans and
FTF1E S7-
this calculation are in compliance with the Florida Energy
specifications covered by this
0
Code.
calculation indicates compliance
�pv0�,
with the Florida Energy Code.
a2„2j+; .. €r�`,�•�°„
PREPARED BY: A41t
Before construction is completed
DATE: _December 18 2010
this building will be inspected for
Section 553.908
-- a
0
compliance with
,
I hereby certify that this building, as designed; is in compliance
Florida Statutes.
with the Florida Energy Code.
00 WE'C¢
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
12/18/2019 5:31 PM .EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 5703 Hickory Drive Energyga ,Bedrooms: .3
Address Type:
Street Address
Building Type: User ,
Conditioned Area: 1335.
Lot # a
Owner Name: Joseph W. Gianna
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: Habitat for Humanity
Rotate Angle: 0
Street:
5703 Hickory Drive
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, Slate, Zip:
Ft. Pierce ,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Inl Design Temp Heating
3 Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce •, FL_VERO_BEACH_MUNI, 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1335 10680
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 Bed Z
191 1528 No
1
1
1 Yes
Yes
Yes
2 c2
18 144No
0
1 Yes
Yes
Yes
3 Bath 2
117 936 No
0
1 Yes
Yes
Yes
4 Bed 3
194 1552 No
1
1
1 Yes
Yes
Yes
5 c3
23 164 No
0
1 Yes
Yes
Yes
6 Living Rm
244 1952 No
0
1 Yes
Yes
Yes
7 Kitchen
260 2000 Yes
0
1 Yes
Yes
Yes
8 Bed 1
174 1392 No
1
1
1 Yes"
Yes
Yes
9 pnty
21 168 No
0
1 • Yes
Yes
Yes
10 clst1
18 144 No
0
1 Yes
Yes
Yes
11 .Bath 1
85 - 680 No
0
1 Yes.
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bed 2 32.5 ft
190.5 ft2
1 0
0
2 Slab -On -Grade Edge Insulatio
c2 2.5 ft
17.5 ft'
—
1 0
0
3 Slab -On -Grade Edge Insulatio
Bath 2• 9 ft
117 ft2
—
1 0
0•
4 Slab -On -Grade Edge Insulatio
Bed 3 26.5 ft
193.5 ft' -
—
1 0
0
58Iab-On-Grade Edge Insulatio
c3 3 ft
- 22.5 ft'
—
1 0
0
_ 6 Slab -On -Grade Edge Insulatio
Living Rm 14 tt
. 245 ft'
_
1 0
0
12/18/2019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpel
7 Slab -On -Grade Edge Insulatio Kitchen 14 ft
252 112
-
1
0
0
8 Slab -On -Grade Edge Insulatio Bed 1
12 ft
174 ft2
e
1
0
0
9 Slab -On -Grade Edge Insulatio pnty
2.5 ft
21.3 ft'
-
1
0
0
10SIab-On-Grade Edge Insulatio clsl 1
2.5 ft
17.5 ft2"
_
1
0
0
11SIab-On-Grade Edge Insulatio Bath 1
18 ft
84.5 ft2
1
0
0
ROOF
Roof .
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pilch
V
#
Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Composition shingles
1407 ft2
222 ft2 Medium
N
0.9
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
1335 112
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Bed
30
Blown
191 ft'
0.1
Wood
2
Under Attic (Vented)
c2
30
Blown
18 ft'
0.1
Wood
_
3
Under Attic (Vented)
Bath 2
30
Blown
117 ft'
0.1
Wood
_
4
Under Attic (Vented)
Bed 3
30
Blown
194 ft'
0.1
Wood
5
Under Attic (Vented)
c3
30
Blown
23 ft'
0.1
Wood
6
Under Attic (Vented) Living Rm
30
Blown
245 R'
0.1
Wood
7
Under Attic (Vented)
Kitchen
30
Blown
252 ft'
0.1
Wood
_
8
Under Attic (Vented)
Bed 1
30
Blown
174 ft'
0.1
Wood
_
9
Under Attic (Vented)
pnty,
30
Blown
21 ft2
0.1
Wood
10
.Under Attic (Vented)
clst 1
30
Blown
18 ft'
0.1
Wood
11
Under Attic (Vented)
Bath 1
30
Blown
85 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
1
E
Exterior Concrete Block- Int Insul
Bed 2
3 6
0 8
0
48.0 112
0
0
0.55
0
-2
S
Exterior Concrete Block - Int Insul
Bed 2
3 13
0 8
0
104.0 ft2
0
0
0.55
0
_ 3
W
Exterior Concrete Block - Int Insul
Bed 2
3 13
6 8
0
108.0 ft2
0
0
0.55
0
4
W
Exterior Concrete Block - Int Insul
c2
3 2
6 8
0
20.0 ft2
0
0
0.55
0
_ 5
W
Exterior Concrete Block -Int Insul
Bath 2
3 9
0 8
0
72.0 112
0
0
0.55
0
-6
N
Exterior Concrete Block - Int Insul
Bed 3
3 13
0 8
0
104.0 ft2
0
0
0.55
0
_ 7
W
Exterior Concrete Block - Int Insul
Bed 3
3 13
6 8
0
108.0 ft2
0
0
0.55
0
8
W
Exterior Concrete Block - Int Insul
c3
3 3
0 8
0
24.0 ft2
0
0
0.55
0
1211812019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS-- .
Adjacent Space
Vr,11 Type
Cavity Width
Height
Sheathing Framing f Solar
Below
%
_ 9 S
Exterior
Concrete Block -Int InsulLiving Rm 3 14 '
0
'8 0 .
112.0 ft°
0
0 0.55
0
_ 10 E
Garage
Concrete Block- Int Insul Living Rm 3 15
0
8 0
120.0 ft-
0
0 0.55
0
_ 11 N
Exterior
Concrete Block - Int Insul Kitchen
3 14
0
8 0
112.0 IF
0
0 0.55
0
_ 12 E
Exterior
Concrete Block - Int Insul Bed 1
3 12
0
8 0
96.0 ft2
0
0 0.55
0
_ 13 S
Garage
Concrete Block - Int Insul Bed 1
3 14
6
8 0
116.0 ft2
0
0 0.55
0
14 N
Exterior
Concrete Block -Int Insul pnty
3 2
6
8 0
20.0 ft2
0
0 0.55
0
_ 15 E
Exterior
Concrete Block - Int Insul clst 1
3 2
6
8 0
20.0 ft2
0
0 0.55
0
_ 16 N
Exterior
Concrete Block - Int Insul Bath 1
3 12
0
8. 0
96.0 112
0
0 0.55
0
17 E
Exterior
Concrete Block - Int Insul Bath 1
3, 6 ..
0,
8 0
48.0 112
0
.0 0.55
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
'
- Ft
In
Ft In
1
S
Wood Living Rm
,' None
.39
3
7
211112
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth 'Separation
Int Shade
Screening
1
S' 2
None Double (Clearj Yes
0.66 1 0.25
Y
16.4 112
2 ft 0 in
1 It 0 in
.Drapes/blinds
Exterior 5
_ 2
.W 5
None Double (Clear) Yes
0.66 0.25.
Y
-7A ft2
2 It 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
3
N 6
None Double (Clear)' Yes
0.66 0.25
Y
16.4 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
S 9
None Double (Clear) Yes
0.66 0.25
Y
24.0 112
6 ft 0 in
1 It 0 in
Drapes/blinds
Exterior 5
5
N 11
Wood Low•E Double Yes"
0.66 0.25
Y
21.0 ft2
4 ft 6 in
1 ft 0 in
Drapes/blinds
None
6
N 11
None Double (Clear) Yes.-:
0.66 0.25
Y
9.5 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
7
E 12
None Double (Clear) Yes
0.66 0.25
Y
16.4 ft2
2 It 0 in
1 ft 0 in
Drapes/blinds
Ededor 5
_ 8
N 16
None Double (Clear) Yes
0.66 0.25
Y
7.4 112
2It 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Will Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
382.8 ft2 382.8 ft2
64 ft
6 It
1
INFILTRATION
# Scope
Method SLA CFM 50 EU1
EgLA
ACH
ACH 50
1 Wtolehouse Proposed ACH(50) .000254
890 48.86 •
91.89
.0881
5
12/18/2019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6
•' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block'
Ducts
1
Electric Strip Heat/
None
COPA
27.3 kBtuntr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 16 27.6 kBtulhr cfm
0.74
1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap
Use
SetPnt
•Conservation
1
Electric None
Garage
0.95 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage,
Carl # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft'
DUCTS
—Supply—
—Return
Air
CFM 25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type
Handier
TOT
OUT
ON
RLF
Heat Coal
1
Attic 6 267 ft-
Attic
67 ft' Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programablre Thermostat: N
Ceiling Fans:
'
Heating
([�]]
Jan Feb [Xl Mar
Apr
�X
May May Jun (� Jut
[[ ]]
[xl Aug
IX
l Sep
[ ]
L 1
Oct
Nov
(ram'
Nov
Dec
Dec
Venting (
l
Jan I[II 1111 Feb [ki Mar
l l l
Jun [ ]]1 Jul
[[ 1]]1 Aug
E ]]] Sep
lxl
(X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD)
AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH)
AM 65 .
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
12/1812019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
'Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
Bed 2
. Default(8 lbs/sq.ft.
ft2
ft
0.3
c2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 lbs/sq.11.
ft2
ft
0.3
Bed 3
Default(8 lbs/sq.ft.
ft2
it
0.3
c3
Default(8 lbs/sq.ft.
ft2
ft
0.3
Living Rm
Default(B lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bed 1
Default(8 lba/sq.ft.
ft2
ft
0.3
pnty
Default(8 lbs/sq.ft.
ft2
ft
0.3
clst 1
Default(8 lbs/s.ft.
ft2
ft
0.3
Bath 1
12/18/2019 6:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts
R
6.0
c) AHU location
Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system:
Capacity
27.6
a) Split system
SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package
SEER
c)Ground/watersource SEER/COP
6. Conditioned Floor area (sq. ft.)
6.
1335
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
0.660
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system:
Capacity
27.3
c) Area
7c.
118.6
a) Split system heat pump
HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance
COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas
AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
gb.
go.
10A1.
10A2. 3.0
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec°/a
g) Other
1081.
10B2. 3.0
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
Yes
11a. 30.0
b) Cross ventilation
No
11b.
c) Whole house fan
No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:. - Z / ? _ o Z- o
Address of New Home: 5703 Hickory Drive City/FL Zip: Ft. Pierce, FL
12/18/2019 5:31:56 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1