Loading...
HomeMy WebLinkAboutEnergy CodeRECEIVED FORM R405-2017 FEB 19020 FLORIDA ENERGY E _ _ FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 5703 Hickory Drive Energygauge Builder Name: Habitat for Humanity Street' 5703 Hickory Drive Permit Office: City, State, Zip: Ft. Pierce , FL, Permit Number: Owner: Joseph W. Gianna Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1328.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=3.0 1092.00 112 b. Concrete Block - Int Insul, Adjacent R=3.0 236.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst rase? No 10. Ceiling Types (1338.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1338.00 112 6. Conditioned floor area above grade (ft2) 1335 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(118.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 267 a. U-Factor: Dbl, U=0.66 118.62 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBlu/hr Efficiency SHGC: a. Central Unit 27.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBlu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heal, 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: - 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1335.3 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1335.30 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits OF Glass/Floor Area: 0.089 Total Proposed Modified Loads: 46.53 PASS Total Baseline Loads: 46.87 I hereby certify that the plans and specifications covered by Review of the plans and FTF1E S7- this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance �pv0�, with the Florida Energy Code. a2„2j+; .. €r�`,�•�°„ PREPARED BY: A41t Before construction is completed DATE: _December 18 2010 this building will be inspected for Section 553.908 -- a 0 compliance with , I hereby certify that this building, as designed; is in compliance Florida Statutes. with the Florida Energy Code. 00 WE'C¢ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 12/18/2019 5:31 PM .EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 5703 Hickory Drive Energyga ,Bedrooms: .3 Address Type: Street Address Building Type: User , Conditioned Area: 1335. Lot # a Owner Name: Joseph W. Gianna Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: 5703 Hickory Drive Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, Slate, Zip: Ft. Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Inl Design Temp Heating 3 Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce •, FL_VERO_BEACH_MUNI, 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1335 10680 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Bed Z 191 1528 No 1 1 1 Yes Yes Yes 2 c2 18 144No 0 1 Yes Yes Yes 3 Bath 2 117 936 No 0 1 Yes Yes Yes 4 Bed 3 194 1552 No 1 1 1 Yes Yes Yes 5 c3 23 164 No 0 1 Yes Yes Yes 6 Living Rm 244 1952 No 0 1 Yes Yes Yes 7 Kitchen 260 2000 Yes 0 1 Yes Yes Yes 8 Bed 1 174 1392 No 1 1 1 Yes" Yes Yes 9 pnty 21 168 No 0 1 • Yes Yes Yes 10 clst1 18 144 No 0 1 Yes Yes Yes 11 .Bath 1 85 - 680 No 0 1 Yes. Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bed 2 32.5 ft 190.5 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio c2 2.5 ft 17.5 ft' — 1 0 0 3 Slab -On -Grade Edge Insulatio Bath 2• 9 ft 117 ft2 — 1 0 0• 4 Slab -On -Grade Edge Insulatio Bed 3 26.5 ft 193.5 ft' - — 1 0 0 58Iab-On-Grade Edge Insulatio c3 3 ft - 22.5 ft' — 1 0 0 _ 6 Slab -On -Grade Edge Insulatio Living Rm 14 tt . 245 ft' _ 1 0 0 12/18/2019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 7 Slab -On -Grade Edge Insulatio Kitchen 14 ft 252 112 - 1 0 0 8 Slab -On -Grade Edge Insulatio Bed 1 12 ft 174 ft2 e 1 0 0 9 Slab -On -Grade Edge Insulatio pnty 2.5 ft 21.3 ft' - 1 0 0 10SIab-On-Grade Edge Insulatio clsl 1 2.5 ft 17.5 ft2" _ 1 0 0 11SIab-On-Grade Edge Insulatio Bath 1 18 ft 84.5 ft2 1 0 0 ROOF Roof . Gable Roof Red Solar SA Emitt Emitt Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1407 ft2 222 ft2 Medium N 0.9 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1335 112 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bed 30 Blown 191 ft' 0.1 Wood 2 Under Attic (Vented) c2 30 Blown 18 ft' 0.1 Wood _ 3 Under Attic (Vented) Bath 2 30 Blown 117 ft' 0.1 Wood _ 4 Under Attic (Vented) Bed 3 30 Blown 194 ft' 0.1 Wood 5 Under Attic (Vented) c3 30 Blown 23 ft' 0.1 Wood 6 Under Attic (Vented) Living Rm 30 Blown 245 R' 0.1 Wood 7 Under Attic (Vented) Kitchen 30 Blown 252 ft' 0.1 Wood _ 8 Under Attic (Vented) Bed 1 30 Blown 174 ft' 0.1 Wood _ 9 Under Attic (Vented) pnty, 30 Blown 21 ft2 0.1 Wood 10 .Under Attic (Vented) clst 1 30 Blown 18 ft' 0.1 Wood 11 Under Attic (Vented) Bath 1 30 Blown 85 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block- Int Insul Bed 2 3 6 0 8 0 48.0 112 0 0 0.55 0 -2 S Exterior Concrete Block - Int Insul Bed 2 3 13 0 8 0 104.0 ft2 0 0 0.55 0 _ 3 W Exterior Concrete Block - Int Insul Bed 2 3 13 6 8 0 108.0 ft2 0 0 0.55 0 4 W Exterior Concrete Block - Int Insul c2 3 2 6 8 0 20.0 ft2 0 0 0.55 0 _ 5 W Exterior Concrete Block -Int Insul Bath 2 3 9 0 8 0 72.0 112 0 0 0.55 0 -6 N Exterior Concrete Block - Int Insul Bed 3 3 13 0 8 0 104.0 ft2 0 0 0.55 0 _ 7 W Exterior Concrete Block - Int Insul Bed 3 3 13 6 8 0 108.0 ft2 0 0 0.55 0 8 W Exterior Concrete Block - Int Insul c3 3 3 0 8 0 24.0 ft2 0 0 0.55 0 1211812019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS-- . Adjacent Space Vr,11 Type Cavity Width Height Sheathing Framing f Solar Below % _ 9 S Exterior Concrete Block -Int InsulLiving Rm 3 14 ' 0 '8 0 . 112.0 ft° 0 0 0.55 0 _ 10 E Garage Concrete Block- Int Insul Living Rm 3 15 0 8 0 120.0 ft- 0 0 0.55 0 _ 11 N Exterior Concrete Block - Int Insul Kitchen 3 14 0 8 0 112.0 IF 0 0 0.55 0 _ 12 E Exterior Concrete Block - Int Insul Bed 1 3 12 0 8 0 96.0 ft2 0 0 0.55 0 _ 13 S Garage Concrete Block - Int Insul Bed 1 3 14 6 8 0 116.0 ft2 0 0 0.55 0 14 N Exterior Concrete Block -Int Insul pnty 3 2 6 8 0 20.0 ft2 0 0 0.55 0 _ 15 E Exterior Concrete Block - Int Insul clst 1 3 2 6 8 0 20.0 ft2 0 0 0.55 0 _ 16 N Exterior Concrete Block - Int Insul Bath 1 3 12 0 8. 0 96.0 112 0 0 0.55 0 17 E Exterior Concrete Block - Int Insul Bath 1 3, 6 .. 0, 8 0 48.0 112 0 .0 0.55 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area ' - Ft In Ft In 1 S Wood Living Rm ,' None .39 3 7 211112 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth 'Separation Int Shade Screening 1 S' 2 None Double (Clearj Yes 0.66 1 0.25 Y 16.4 112 2 ft 0 in 1 It 0 in .Drapes/blinds Exterior 5 _ 2 .W 5 None Double (Clear) Yes 0.66 0.25. Y -7A ft2 2 It 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 N 6 None Double (Clear)' Yes 0.66 0.25 Y 16.4 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 S 9 None Double (Clear) Yes 0.66 0.25 Y 24.0 112 6 ft 0 in 1 It 0 in Drapes/blinds Exterior 5 5 N 11 Wood Low•E Double Yes" 0.66 0.25 Y 21.0 ft2 4 ft 6 in 1 ft 0 in Drapes/blinds None 6 N 11 None Double (Clear) Yes.-: 0.66 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 E 12 None Double (Clear) Yes 0.66 0.25 Y 16.4 ft2 2 It 0 in 1 ft 0 in Drapes/blinds Ededor 5 _ 8 N 16 None Double (Clear) Yes 0.66 0.25 Y 7.4 112 2It 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Will Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 6 It 1 INFILTRATION # Scope Method SLA CFM 50 EU1 EgLA ACH ACH 50 1 Wtolehouse Proposed ACH(50) .000254 890 48.86 • 91.89 .0881 5 12/18/2019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 •' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block' Ducts 1 Electric Strip Heat/ None COPA 27.3 kBtuntr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 27.6 kBtulhr cfm 0.74 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt •Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage, Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Coal 1 Attic 6 267 ft- Attic 67 ft' Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programablre Thermostat: N Ceiling Fans: ' Heating ([�]] Jan Feb [Xl Mar Apr �X May May Jun (� Jut [[ ]] [xl Aug IX l Sep [ ] L 1 Oct Nov (ram' Nov Dec Dec Venting ( l Jan I[II 1111 Feb [ki Mar l l l Jun [ ]]1 Jul [[ 1]]1 Aug E ]]] Sep lxl (X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 . 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 12/1812019 5:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction 'Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Bed 2 . Default(8 lbs/sq.ft. ft2 ft 0.3 c2 Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 lbs/sq.11. ft2 ft 0.3 Bed 3 Default(8 lbs/sq.ft. ft2 it 0.3 c3 Default(8 lbs/sq.ft. ft2 ft 0.3 Living Rm Default(B lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 ft 0.3 Bed 1 Default(8 lba/sq.ft. ft2 ft 0.3 pnty Default(8 lbs/sq.ft. ft2 ft 0.3 clst 1 Default(8 lbs/s.ft. ft2 ft 0.3 Bath 1 12/18/2019 6:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 27.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c)Ground/watersource SEER/COP 6. Conditioned Floor area (sq. ft.) 6. 1335 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.3 c) Area 7c. 118.6 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 gb. go. 10A1. 10A2. 3.0 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec°/a g) Other 1081. 10B2. 3.0 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date:. - Z / ? _ o Z- o Address of New Home: 5703 Hickory Drive City/FL Zip: Ft. Pierce, FL 12/18/2019 5:31:56 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1