Design Pressure Report (McNutt) - Master Craft Aluminum Products
Property Information Owner:McNutt Address:36 Nogales Port St Lucie, Fl 34952 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:25 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 53 63 7 30.7 -39.9 2 Int 37 63 7 31.5 -34.2 3 Int 53 55 7 31.0 -33.7 4 Int 53 55 7 31.0 -33.7 5 End 74 63 7 30.0 -38.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1