Loading...
HomeMy WebLinkAboutDesign Pressure Report (Immediato) - Master Craft Aluminum ProductsProperty Information Owner:Immediato Address:6672 Tulipan Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 74 63 7 30.0 -32.8 2 Int 36 63 7 31.5 -34.3 3 Int 53 38 7 31.8 -34.5 4 Int 72 83 7 29.5 -32.2 5 Int 96 83 7 28.9 -31.6 6 Int 111 52 7 29.5 -32.3 7 Int 26 52 7 32.5 -35.2 8 Int 26 52 7 32.5 -35.2 9 Int 26 40 7 32.5 -35.2 10 Int 53 52 7 31.1 -33.9 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1