'6FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MAURO ADDITION
Builder Name:
Street: 3101 MATHEWS ROAD
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (580.0 sqft.)
Insulation Area
2. Single family or multiple family Single-famity
a. Concrete Block - Int Insul, Exterior
R=4.1 580.00 ft2
b. NIA
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms (Bedrms In Addition) 0(0)
d. N/A
R= ft2
10. Ceiling Types (420.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 420.00 ft2
6. Conditioned floor area above grade (112) 420
b. N/A
R= ft2
Conditioned Floor area below grade (ft2) 0
c. NIA
R= 112
11. Ducts
R ft2
7. Windows(191.3 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
5 40
a. U-Factor. Sgl, U=0.65 191.33 ft2
I
SHGC: SHGC=0.25
b. U-Factor: N/A fix
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
47.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems - None required
a.
Cap: N/A
8. Floor Types (420.0 sqft.) Insulation Area
EF: 0.000
a. Slab -On -Grade Edge Insulation R=0.0 420.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.456 Total Proposed Modified Loads: 16.20
PASS
SS
Total Baseline
Loads: 16.28
r/1�7�7
1 hereby certify that the plans and specifications covered by
Review of the plans and
FgE1: STgl
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
,
ZOEBefore
with the Florida Energy Code.
F nm, r+..•,
�"•-.��2i � � � O
PREP D B
construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
-},j-
I hereby certify that this buildirig, as designed, is in compliance
Florida Statutes.
11
with the Florida Energy Code.
COD WE fR�
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory seal d in accordance with
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FILE COPY
3/12/2020 8:09 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
,r
PROJECT
• Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MAURO ADDITION
User
1
Single-family
Addition
Bedrooms: 0
Conditioned Area: 420
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot # I
BIocWSubdivision:
PlatBook:
Street: 3101 MATHEWS ROAD
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Dally Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
420 4200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
420 4200 No 0
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation Main 88 ft 0
420 ft'
---- 0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 455 ft' 0 ft' Unfinishe
N
0.5 No 0.6 No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 420 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
420 ft' 0.11 Wood
3/12/2020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
In Mrpll TypeSpace
-v i o Ft In R In
Area
R-1U.s.
M^ n
1 SW
Exterior Concrete Block - Int Insul Main
4.09999 14 10
140.0 ft'
0 0.3
0
2 NW
Exterior Concrete Block- Int Insul Main
4.09999 30 10
300.0 ft'
0 0.3
0
3 NE
Exterior Concrete Block - Int Insul Main
4.09999 14 10
140.0 ft'
0 0.3
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID Flame Panes
;NFRC
U-Factor SHOO .Imp Area
Depth
Separation
ku.Srwde
S.cregning
1
SW 1 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
0 ft 7 in
Drapes/blinds
Exterior 1
2
SW 1 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
0 R 7 in
Drapes/blinds
Exterior 1
3
SW 1 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
0 ft 7 in
Drapes/blinds
Exterior 1
_ 4
NE 3 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
0 ft 7 in
Drapes/blinds
Exterior 1
5
NE 3 Metal Low-E Single
Yes
0.65 0.26 N 15.0 ft'
2 ft 0 in
0 ft 7 in
Drapes/blinds
Exterior 1
6
NE 3 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
0 It 7 in
Drapes/blinds
Exterior 1
_ 7
NW 2 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
2 ft 5 in
Drapes/blinds
Exterior 1
8
NW 2 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
4 ft 5 in
Drapes/blinds
Exterior 1
9
NW 2 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
6 ft 0 in
Drapes/blinds
Exterior 1
10
NW 2 Metal Low-E Single
Yes
0.65 0.25 N 15.0 ft'
2 ft 0 in
5 It 0 in
Drapes/blinds
Exterior 1
11
NW 2 Metal Low-E Single
Yes
0.65 0.25 N 41.3 ft2
2 ft 0 in
3 ft 0 in
Drapes/blinds
Exterior 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000318
350 19.21 36.14
.1204
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
i
Electric Strip Heat/Supplement
None
COP:1 34 kBtufnr
1
sys#i
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/Supplemental for a
None
Single SEER: 16 47 kBtu/hr 1410 cfm
0.8 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model #
Area
Volume
FEF
ft'
3112t202O 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
— Supply—
—
Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6
40 ft'
Attic
1 ft'
Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: Y
C
Fans:Coolin
Jan
Feb
Mar
Mar
Apreiling
Apr
ay
May
Jun
���XXX]
[ ) Jul
[
[X� Aug
[X]
I ] Sep
Oct
Oct
H Nov
Nov
H Dec
Dec
Venting Jan
Feb
Ixl
[
Jun
I) Jul
l 111 Aug
[)Sep
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
76
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
65
6B
68
68
68
68
68
68
PM
68
68
68
68
68
6B
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
6B
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauk 8 Ibsls
.ft.
0 ft'
0 It
0.3
Main
3/1212020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
-xA
RIGHT SIDE ELEVATION _
LEFT SIDE ELEVATION
oL�F�Gf.7G�IR0
moon®=�
. .RIP
REAR ELEVATION
FOUNDATION PLAN ....,.
FIAOR/ELF.CTRICAL PLAN
ada
:, . ,
. --W
nwaoum,em�,�mva
I'
BW/OOd6Mrt0@yyp)PEbOMe
....
J
.2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MAURO ADDITION Builder Name:
Street: 3101 MATHEWS ROAD Permit Office:
City, State, Zip: FT. PIERCE, FL, Permit Number:
U
Owner: Jurisdiction:
x
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Ceiling/attic
Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the too plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between vvindow/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of Insulation.
Floor framing cavity Insulation shall be installed to
(Including
maintain permanent contact with the underside of
above -garage
subiloor decking, or floor framing cavity insulation she!!
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor Insulation, Insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crayAspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned spay, shall be ee_=led.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wring.
Showeritub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electricallphone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed. '
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Plates and walls or ceilings.
n. In addition, Inspection of log walls shall be In accordance with the provisions of ICC-400.
311212020 8:09 AM EnargyGaugcO USA 6.0002 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 off
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEvEII IEPII ) nISPLAV CARD
ENERGY PERFOR. verge e_ e..e_ e_e e_ v e JMe �
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
0
13. Cooling system: Capacity
47.0
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
420
d) Room unit/PTAC EER
e) Other
16.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.0
c) Area
7c.
191.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
98.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
go.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation P.-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee wails/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code
� compliant features.
Builder Signature: V`//�Vt/' v Date:
Address of New Home. 3101 MATHEWS ROAD City/FL Zip: FT. PIERCE. FL
3/12/2020 8:09:45 AM EnergyGaugeO USA 6.0.04 (Re.. 1) - FlaRes2017 FBC 5th Edition (2017) Compliant SofNmre Page 1 of 1
4F. wrightsoft° Project Summary Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Emil: OUICKCALCS@A0LC0M
For: MAUROADDITION
3101 MATHEWS RD., FT. PIERCE, FL
Notes:
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Inside db 70 OF
Outside db 90 OF
Inside db 75 OF
Design TD 28 OF
Deissign TD 5 OF
Darange M
Relative humidity 50 %
Moisture difference 61 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure
25659
Btuh
Structure
22290
Btuh
Ducts
8372
Btuh
Ducts
12675
Btuh
Central vent (0 cfm)
0
Bth
Central vent (0cfm)
0
Btuh
(none)
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
34031
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipmentsenslbleload
33217
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3681
Btuh
Ducts
3521
BW,h
Central vent (0 cfm)
0
Btuh
Heatingg
Cooling
(none)
Area
2586
2586
Equipment latent load
7201
Btuh
Volume (f?)
25860
25860
Airchan�gges/hour
0.32
138
0.16
Equipment Total Load (Sen+Lat)
0.70 SHR
40419
4.0
Btuh
Equiv.AVF(cfm)
69
Req. total capacity at
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Lennox
Trade
Trade LENNOX
Model
Cond EL16XC1-047-230A•'
AHRI ref
COO CBA27UHE-048-230'++TDR
AHRI ref 10259481
Efficiency
100 EFF
Efficiency 13.0 EER,16
SEER
Heating input
7.8
kW
Sensible cooling
32900
Btuh
Heating output
26550
Btuh
Latent cooling
14100
Btuh
Temperature rise
50
OF
Total cooling
47000
Btuh
Actual air flow
483
cfm
Actual air flow
1567
cfm
Airflowfactor
0.014
cfm/Btuh
Airflowfactor
0.045
cfm/Btuh
Static pressure
0.50
in H2O
Static pressure
0.50
in H2O
SpacetiTermos"Wt
Load sensible heat ratio
0.83
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrr`1F+ts. - 2020-Mar-1208:12:05
.� ..... RghtSulbaSUnKerm12019l9.0.07RSU0910i Paget
ACC ...CKUD menbiWrightmftMAC MUROAOIXl10Rwp QIc=MB F=tWorface SE
�+wrightsoft° Right-J®Worksheet Job'
Entire House By:
r•
QUICK CALCS, INC.
317 ST.. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: 0UICKC4LCS@AOL.0OM
1
Room name
Entire House
EXISTING HOUSE
2
E_V--ed vsll
218D It
1sO.0 8
3
Room height
10D It
10D 8 heaVcool
4
Room dimensions
57.0 x 38.0 8
5
Room area
2586.0 IF
2166D 1F
Ty
construction
number
U-value
MWhfiVF)
Or
HTM
(BtuhAF)
Area (fF)
or perimeter (f)
Load
(Btuh)
Area (IF)
or perimeter (fl)
Load
(BWh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gass
NIPS
Heal
Cool
6
13A-0acs
0.143
ne
4D0
2.19
' 520
445
1782
974
380
350
1401
766
F—G
`G
4A5-2ob
4A5-2ob
0560
OS60
ne
ne
15.68
15M
33.75
27.45
30
45
0
0
470
706
1012
1235
30
0
0
0
470
0
1012
0
l{J
13A-0acs
0.143
se
4D0
2.19
570
484
1936
1058
570
484
1936
1058
11
F—G
�1—(G
10&v
4A5-2ob
4A5-2ob
13AAocs
OEM
0560
0560
0.143
se
se
se
sw
16.80
15M
1588
4.00
2039
1925
25.15
2.19
20
6
60
520
7
5
30
440
343
94
941
1760
416
116
1509
962
20
6
_ 6D
360
7
5
30
345
343
94
941
1380
416
116
ism
754
W
I--G
1013v
4AS-2ob
0.600
0560
sw
sw
1680
15.68
2039
25.15
20
15
7
7
343
235
416
377
20
15
7
7
343
235
416
377
I�—GG
Y,J
4A5-2ob
13A41acs
1013-v
4A5-2ob
4AS2ob
0.560
0.143
0800
0560
0560
sw
my
my
nw
=
16.68
4D0
1680
1588
15.68
2083
2.19
25.00
33.75
33.75
45
570
41
60
20
22
449
0
0
0
706
1796
694
941
314
937
982
1033
2025
675
0
270
0
0
20
_ 0
250
0
0
0
0
1001
0
0
314
0
547
0
0
675
F—G
C
16G3031
0D32
-
090
128
2586
2586
2317
3310
2166
2166
_ 1941
2772
F
22A-V
0989
-
_2789
ODO
25M
218
6037
0
2166
160
4431
0
r7
o)AED excutyo0
1196
-217
Envelope loss(gain
21415
18233
14829
10201
12
a) Infiltration
4244
1137
31151
834
b) Roomventiation
0
0
01
0
13
Internal gains: Occupants @ 230
Appliances/other
4
920
2000
4
920
1 2000
Subtotal Qines 6to 13)
25659
22290
17944
13955
Less external load
0
0
0
0
Less hansfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
25659
M90
17W
13955
15
Duclloads
33%
57%
8372
12675
33%
57%
5855
7936
Total room load
34037
34985
23800
21891
Airrequired (efm)
483
1567
338
981
Calculatons approved bYACCA to meet ai requirements of Manual J 8rh Ed
-Fy- wr;l0"In - 2020-Mar-120812.05
• I2ghtSuile®Univeml 20191RO07 RSt108101 Pagel
...GOOD m nt5\WnghboftHA0M UR0AC001ON.mp QIc=MJ6 FmntDDorfaces SE
• �+wrightsoft° Right-JO Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LLUE LANE, FORT PIERCE, FL 34946 Phone:772A66-6799 Email: OUICKCALOS@AOL.OJM
Jab:
Date:
By:
1
Room name
NEWFAMLYROOM
2
F��osed v..lt
58.0 ft
3
Room helgM
10D R heatkool
4
Room dimensions
30D x 14D ft
5
Roomarea
420D fF
Ty
Construction
U-value
Or
HTM
Area (fF)
Load
Area
Load
number
(BWhfiF-°F)
or perimeter (ff)
(BWh)
or perimeter
Heal
Cool
Gross
WP)S
Heal
Cool
Gross
NrP)S
Heat
Cool
6
W
13AAocs
0.143
no,
4DO
2.19
140
95
380
208
4A5-2ob
4A5-2ob
ORM
0560
ne
ne
15.68
15.68
33.75
27.45
0
45
0
,0
0
706
0
1235
13A-4ocs
0.143
se
4D0
2.19
0
0
0
0
11
10B-v
0.6f10
se
16M
2039
0
0
0
0
4A5-2ob
05W
se
15.68
1925
0
0
0
0
4A5-20b
0560
se
15.68
25.15
0
0
0
0
w
13A-4ccs
0.143
sw
4.00
2.19
140
95
380
208
10B-v
O.600
sw
16.80
2039
0
0
0
0
4A5-2ob
0560
sw
1558
25.15
0
0
0
0
4A5-2ob
0560
sw
1558
20.83
45
22
706
937
W,
13A4ocs
0.143
my
4.00
2.19
300
199
795
435
106-v
ODW
my
16so
25.00
41
0
694
1033
�C
4AS20b
0560
my
15.68
33.75
60
0
941
2025
L�CC
4A6-20b
0560
mr
15.68
33.75
0
0
0
0
C
16C30al
OD32
-
090
128
420
420
376
538
F
22A4p1
0989
-
27j69
ODO
420
58
1606
0
9
e)AE4 a+cu!81m!1
1414
Envelope lossrgam
6585
6032
12
a) Infiltration
1129
302
b) Roomventlalion
0
0
13
Internal gains: Occupants@ 230
0
0
Appliances/other
0
Subtotal Qines 6to 13)
7714
8335
Less extemal load
0
0
Lesstrsnsfer
0
0
Redisbibution
0
0
14
Subtotal
7714
8335
15
Duct loads
33%
57%
2517
4740
Total mom load
10231
13075
Air required(cfm)
145
686
Calculations approved byACCA to meet a0 requirements of Manual J 8th Ed
-f}F = 191•�0� 2020-Mar-12 08:12.D5
�A- Po9MSuWUnNe=1201919.0.07RSU08101 Page
...CKC=men4lWnghtmftFMQMAUROADDRIOUmp Calc=W8 Front Duorfamv SE
-1 wrightsoft° Duct System Summary RECEIVED Jose:
Entire House By:
QUICK CALCS, INC. MAR 12 2020
ST. Lucie County, Permitting
317 ST. LUCIE LANE, FORTPIERCE, FL 34946 Phone, 772-466-6799 Email: OUiCXCALCS@AOL
Project Information
For: MALIROADDITION
3101 MATHEWS RD., FT. PIERCE, FL
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110 / 0.110
in H2O
0.080
in/100ft
483
cfm
120 ft
Cooling
0.50
in H2O
0.28
in H2O
0"
in H2O
0,110/0.110
in H2O
0.080
Intl00ft
1567
cfm
Design
Htg
Gig
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FIR
(In)
(in)
Mat
Ln (ft)
Ln (ft)
Trunk
EXISTING HOUSE-E
c 21891
338
981
0.080
18.0
Ox0
VIFx
0
0
NEW FAMILY ROOM
c 6537
73
293
0.080
8.0
Ox 0
VIFx
29.8
90.0
SO
NEW FAMILY ROOMmC
o 6537
73
293
0.080
8.0
0--0
VIFX
27.2
90.0
stt
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(n)
H x W
(In)
Duct
Material
Trunk
st1
PeakAVF
145
586
0.080
746
12.0
0 x 0
V'nIFb(
Name
Grille
Size (in)
Htg
(dm)
Gig
(dm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rbl
Ox0
483
1567
0
0
0
0
Ox 0
VIFx
4
Bold'da0c values have beennunuaW overridden
�+ wrightsoW
R1ght-SultsGUnivewI20191s0.07 RSU08101
ACC..,CKCaoumontalWrlghtwft"GNMUROADDRION.mp Calo=MJB FrontCoorfaoea SE
2020-Mar-12 08:12:05
Page 1