HomeMy WebLinkAboutSANTANGELO CONS REVISED 4-30 S&SVAC LINE 3.5' DEEP4.5' DEEP SKIMMER TILED STEP EDGES TILED BENCH EDGE CHILD SAFETY BARRIER FENCE NO CLOSER THAN 20" FROM WATERLINE NOTE: POOL PUMP MOTOR LOCATED ABOVE GRADE. PROVIDE SEPARATE CIRCUIT FOR PUMP MOTOR(S)AND HEATER(S) ETC RAIN TIGHT OUTDOOR ELECTRICAL PANEL (SIZED PER LOAD) PROVIDE HAND HOLDS AS REQUIRED ANSI/NSPI-5-2003 OR MAINTAIN 4" GRABBABLE SURFACE (DETERMINE IN FIELD) DECO DRAIN TO DRAIN AWAY FROM THE HOUSE. DECO DRAIN TO BE ATLEAST 1' FROM HOUSE. DECO DRAIN EXACT LOCATION TO BE DETERMINED IN FIELD. N.T.S.N.T.S.N.T.S. 5 f t . 1 i n . 3 ft. 9 in. 4 f t . 4 i n . 17 ft. 9 in.1 2 f t . 40 ft. 1 8 f t . 53 ft. 7 in. 2 2 f t . 1 0 i n . 7 f t . 1 0 i n . 7 f t . 1 0 i n . 8' FASCIA HEIGHT 8' T0 13' GABLE ROOF LINE COLOR LEDCOLOR LED COLOR LED TRUSSED ROOF PATIO FLOCRETE AND STAIN TO MATCH 1 5 f t . 6 i n . 8 ft. 48" SHEER DESCENT WATERFALL 0"+6"+12"+12"+6"0" 20 ft. SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 18" 20" max. N.T.S. W.L. 18" MIN. ( ENTIRE PERIMETER) #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL 4 TOTAL ) 8 GAUGE SOLID COPPER WIRE EQUIPOTENTIAL BONDING GRID DETAIL PER N.E.C. 2014 SEC. 680.26 (WHERE ADOPTED) SOIL MINIMUM 18" (MAXIMUM 24") FROM EDGE OF POOL AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP PAVER DECK OR CONCRETE DECK MANUAL MOTOR STARTER SWITCH 1.65HP VARIABLE SPEED JANDY PUMP MOTOR WITH BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT (GFCI PROTECTED) TIME CLOCK W. P. DISCONNECT 12 VOLT TRANSFORMER JUNCTION BOX (3) POOL LIGHTS (GFI NOT REQUIRED) S.P.S.T. TOGGLE SWITCH POOL PANEL W/ 80 AMP BRKR & (2)-#6 & (2) #10 GND THHN CU IN 1" RPVC CONDUIT ELECTRICAL DIAGRAM N.T.S. 1. ALL ELECTRICAL TO COMPLY WITH 2014 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT(S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/#8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. -20' MAX. FROM WATER’S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B) ELECTRICAL DIAGRAM AND GFI OUTLET PER 2014 NEC PUMP BONDED BACK TO POOL JANDY TRUE CLEAR SALT SYSTEM PUMP SALT MAX. WIDTH MIN. DEPTH 15'6" SHAPE FILL FROM EXCAVATION TILE FILTER PUMP HP: LIGHTS TRNFORM: MAIN DRAIN: SKIMMER RETURNS: VALVED VAC LINE DISCHARGE LINE CHLORINATOR HANDRAIL DIVING BOARD HEATER THERMEAU S125 HEAT PUMP VACUUM HEAD VACUUM HOSE LEAF SKIMMER TREE / STUMP REMOVAL REMOVE EXISITING CONCRETE PUMP POOL PATIO SCREEN INC BY PIONEER ELECTRICAL EDS INC POOL PATIO DECK DRAIN GALLON CAPACITY-POOL 14,250 GAL. GALLON CAPACITY-SPA NA TURN-OVER RATE TERMITE TREAT BARRIER MAX. LENGTH 40' 3.5'MAX. DEPTH 4.5' CUST HAUL ELEVATION T.B.D INTERIOR FINISH GEM CS200 PUMP MAKE PER FBC 4501.20 JANDY 1.65HP VS FLOPRO POOL SPA POOL 3 CLR LED SPA NA POOL 300 WATT SPA POOL 2 SPA 0 (1) POOL 3 SPA 0 JETS:POOL SPA 0 INCL FILL LINE NA TO GROUND JANDY TRU CLEAR SALT SYSTEM NA LADDER NA NA SLIDE NA INCL INCL INCL POLE BRUSH TEST KIT INCL INCL INCL NA NA CONCRETE FLOCRETE INC 6 hrs INC INC NA SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL –508 SQ. FT 111 LN FT SPECIFICATIONS NA MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES TO 8 ft./s SUCTION LINES, 10fps MAX RETURN LINE JOB NAME: SANTANGELO ADDRESS: 6780 DICKINSON TERR PORT SAINT LUCIE FL 34952 PERMIT NO.: DATE DRAWN: APRIL 30TH, 2020 DRAWN BY: BOBBY AUSTIN BA CHECKED BY: AARON H. ALLEN CUSTOMER APPROVAL: SCALE: 1/4" = 1' 1.65HP VS FLOPRO FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 NA · APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION FOR RESIDENTIAL 4 AARON H. ALLEN PE, FL REG. NO. 86620 FL POOLS, INC. CONCRETE EXISTING PATIO FLOCRETE AND STAIN ELECTRIC PREWIRE AND STAND BY OWNER 0 003' 40' 3.5' 4.5' 37' CYCOLAC MAIN DRAIN LIGHT 1 ROW OF WATERLINE TILE 1' R #3 STEEL @ 12" O/C E.W. 6" THICK WATERLINE DECK WALLS SHALL NOT SLOPE GREATER THAN 11 FLOOR SLOPES FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 4 ½” THICK TYPICAL SECTION THRU POOL (NO SCALE) FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUITMINIMUM WATER LEVEL POOL PATIO UNDERWATER LIGHT DETAIL (NO SCALE) UNDERWATER LIGHT 1 8 " NO NICHE OUTSIDE ANGLE OF REPOSE 6' AND FURTHER = 4" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 3' TO 6' = 6" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 4 " w a l l s 6 " 5 f t . 3 ft. 6 ft. 9 ft. 8 " w a l l s EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: * SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL A N G L E O F R E P O S E N.T.S. GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. REBAR SHALL BE COVERED BY A MINIMUM OF 3" POOL DETAIL MINIMUM (2) SUCTION LINES PER PUMP 3 FT. SEPARATION OR SEPARATE PLANES 3 FT. MIN. 8 FPS MAX 6 FPS MAX · APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION FOR RESIDENTIAL AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE 3" PLUMBING LINES FROM SUMP W/ 3" TEE TO FILTRATION PUMP APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 2" LINE TO FIRST TEE. REC. PUMP = 1.65HP JANDY FLOPRO VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 98 GPM @ 38 TDH 2.5" SUCTION PIPE @ 98 GPM = 7.48 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 98 GPM = 5.74 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2" PRESSURE PIPE @ 98 GPM = 9.77 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO ANSI-7/ANSI-15 CONCRETE DECK BEND INTO DECK @ 48" O.C. MAX.OVERPOUR (OR CAP TILE, WHERE APPLICABLE 6"X6" TILE INTERIOR FINISH 4 " 4 1/2" TYP. WALL 4" SLAB 2500 FIBER MIX STEEL-TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP 6" TYP. FLOOR THREADED PLUG GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL GRAVEL BED NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL TYPICAL WALL SECTION & WELL POINT (NO SCALE) FILTRATIO N PUMP LOW SPEED FILTRATION PUMP HIGH SPEED FILTRATION PUMP VSFHP1.65 PERFORMANCE CURVES N.T.S. 3" SUCTION LINE MAX 181 G.P.M. LOCATION OF WATER BOND BY POOL EQUIPMENT PB-2008 WATER BONDING WIRE TO GRID POOLBOND PB-2008 IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT CONTACT WITH AN APPROVED CORROSION-RESISTANT CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES (5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME. N.T.S RAISED AREA ELEV. & GRADE EXISTING GRADE OR 1' TO 4' SLOPE RAISED CONCRETE EXPOSED & TOPPED (1) #5 REBAR POOL PERIMETER OR (2) #3 REBAR FOOTER DETAIL 8" NO SCALE (1) #5 REBAR OR (2) # 3 REBAR 8"REBAR SHALL BE COVERED BY A MINIMUM OF 2.5" A 4 B 1 23 EQUIPMENT LAYOUT N.T.S. 5 LEGEND 1. 1.5" VACUUM LINE 2. 3" POOL MAIN DRAIN 3. 2" SKIMMER LINE 4. 2" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL 5. JANDY TRUE CLEAR SALT SYSTEM 6. THERMEAU S125 HEAT PUMP A. 1.5" TO WASTE OR DISCHARGE TO GROUND B. 1.65HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER C. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE D. VALVES (TYPICAL) E. INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGR’S SPECS (FIELD VERIFY LOCATION) PIPING SCHEMATIC E D C 6 ARTISAN HAND RAIL 1001 POWDER COATED. ALREADY PUT ASIDE IN WAREHOUSE. R R R 1.5" 1.5" 1"1"1" 1.5" 1.5"2"2" 2" LINE TO FIRST TEE 2" 3" 3" 2.5" SAFETY BARRIER PER FRC R4501.17.1- R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 POOL BARRIER PER FRC R4501.17.1- R4501.17.3 AND ANSI/NSPI-5-1995 N.T.S. N.T.S.N.T.S.N.T.S.N.T.S. EQUIPMENT PAD PER FBC R4501.22 *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 EQ. LAYOUT 30" MIN. CLEARANCE IN FRONT OF SUBPANEL HEAT VERIFY EXACT LOCATION IN FIELD WITH SUPERVISOR STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 3000 PSI. MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED +6" ABOVE POOL N.T.S. 12" MAX. 10" MIN. STEPS #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE48" MAX WATER DEPTH HEAT PUMP W (2) #6 CU, (1) #10 NEUT. & (1) #10 CU GROUND IN ¾” CONDUIT (CONNECT TO 50 AMP-2 POLE GFCI BREAKER) A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7TH STREET, LA VERNE, CA, 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. 32 ft. DIRECTIONS ST. LUCIE WEST TO PRIMA VISTA TO RIO MAR LEFT TO BEACH LEFT TO OLEANDER RIGHT TO OLEANDER PINES RIGHT TO DICKINSON LEFT 8 f t . 2 i n . 3 f t . ADDED 1'10" TO REAR DECK