HomeMy WebLinkAboutProduct Approvals, NOAs, METAL AND FLATSCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 17-1016.01 and consists of pages 1 through 38.
The submitted documentation was reviewed by Alex Tigera.
011011 •
APPROVED
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 1 of 38
MIAiri6C7�tD
f
MIAMI-DADE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
NOTICE OF ACCEPTANCE (NOA)
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 17-1016.01 and consists of pages 1 through 38.
The submitted documentation was reviewed by Alex Tigera.
011011 •
APPROVED
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 1 of 38
Elastoflex SA P FR 32' 10" x 3' 3-3/8" ASTM D 6164, Self -adhered, fire -rated, polyester reinforced, SBS
Type I modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polyfresko G SBS SA 32' 10" x 3' 33/s" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko G SBS SA 32' 10" x 3' 3 3/$"
FR
Polyreflect 32' 10" x 3' 3-N8"
ASTM D 6164, Self -adhered, fire -rated, fiberglass reinforced, SBS
Type I modified bitumen membrane with a self -adhering back
face and a granule top surface.
ASTM D 6164, Self -adhered, polymer, SBS modified bitumen
Type I membrane with a self -adhering back face and a smooth
top surface.
XtraFlex SBS G SA
32' 10"x3'3-3/8" ASTM D 6164,
Self -adhered, fire -rated, polyester reinforced, SBS
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polybond
32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
FR
Type I
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polyflex
32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
Type I
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
XtraFlex APP S
32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a bum off polyethylene back
face and a smooth or sanded top surface.
PolyKool
32' 10" x 3' 3-3/8" ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a white film laminate on the top surface.
XtraFlex Kool APP S
32' 10" x 3' 33/8" ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
SA
Type I
bitumen membrane with a self -adhering back face and
a white film laminate on the top surface.
Polyflex SA P
32' 10" x 3' I3/8" ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyflex SA P FR
32' 10" x 3' 33/$" ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polyfresko G APP SA 32' 10" x 3' I3/s"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko G APP SA 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
FR
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface
XtraFlex APP G SA 32' 10"x3'3_3/8,'
ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
MMMMMADECOUNTYRI
NOA No.: 19-0311.04
• Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 3 of 38
APPROVED INSULATIONS:
TABLE Z
Product Name
Product Description
Manufacturer
With Current NOA)
Polytherm-H
Polyisocyanurate foam insulation
Polyglass USA, Inc.
Polytherm
Polyisocyanurate foam insulation
Polyglass USA, Inc.
Polytherm G
Polyisocyanurate foam insulation
Polyglass USA, Inc.
XtraFlex Polyiso
Polyisocyanurate foam insulation
Polyglass USA, Inc.
XtraFlex Polyiso G
Polyisocyanurate foam insulation
Polyglass USA, Inc.
ACFoam-II
Polyisocyanurate foam insulation
Atlas Roofing Corp
ACFoam-III
Polyisocyanurate foam insulation
Atlas Roofing Corp
Structodek High Density Fiberboard Roof Wood fiber insulation board
Blue Ridge Fiberboard, Inc.
Insulation
DensDeck, DensDeck Prime
Gypsum insulation board
Georgia-Pacific Gypsum LLC
H -Shield
Polyisocyanurate foam insulation
Hunter Panels, LLC
H -Shield CG
Polyisocyanurate/perlite composite insulation
Hunter Panels, LLC
ENRGY-3
Polyisocyanurate foam insulation
Johns Manville Corp.
Fesco Board
Expanded mineral fiber
Johns Manville Corp.
Multi -Max FA -3
Polyisocyanurate foam insulation
Rmax Operating, LLC.
SECUROCK Gypsum -Fiber Roof Board
Fiber reinforced coverboard
United States Gypsum
Corporation
MlAMMADECONOA No.: 19-0311.04 -"
IIS ±'"* q Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 5 of 38
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.
Number Product
Product
Application
Specification
Manufacturer
Name
Description
Rate
1. Gravel
To be installed in a flood coat
400 lbs/sq
N/A
Generic
of approved asphalt at 60 lbs/sq
2. Slag
To be installed in a flood coat
3001bs/sq
N/A
Generic
of approved asphalt at 60 lbs/sq
3. KM Acryl 15
A premium white or tinted
1-1 %2 gaUsq
ASTM D6083
Polyglass USA,
elastomeric acrylic based roof
Inc.
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
4. KM Acryl 15 QS
A premium white or tinted
1-1'/i gaUsq
ASTM D6083
Polyglass USA,
quick setting, elastomeric
Inc.
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this
coating.
5. KM Acryl 25
A premium white or tinted
1-1 %2 gal/sq
ASTM D6083
Polyglass USA,
elastomeric acrylic based roof
Inc.
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
6. KM Acryl 25 QS
A premium white or tinted
1-1 %2 gaUsq
ASTM D6083
Polyglass USA,
quick setting, elastomeric
Inc
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this
coating.
7. KM -PS #220
A single component, solvent,
1.25 gal/sq
ASTM D6694
Polyglass USA,
white or tinted, silicone
Inc
coating.
8. KM -PS #250
A premium grade high solids,
1.25 gal/sq
ASTM D6694
Polyglass USA,
white or tinted, single
Inc
component, moisture cure,
fluid applied silicone coating
01M
UNTY NOA No.: 19-0311.04
MMM
El J. Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 7 of 38
APPROVED SURFACING:
TABLE 4
Chosen components
must be applied according to manufacturer's application instructions.
Number
Product
Product
Application
Specification
Manufacturer
Name
Description
Rate
18.
PolyBrite 95
A single component, white or
1.25 gal/sq
ASTM D6694
Polyglass USA,
tinted, solvent, moisture cure
Inc.
silicone coating.
19.
POLYPLUS 60
Non-fibered aluminum roof
%2-1 gal/sq
ASTM D2824
Polyglass USA,
coating.
Type I
Inc.
20.
POLYPLUS 65
Fibered aluminum roof coating.
1 %2-2 gal/sq
ASTM D2824
Polyglass USA,
Type III
Inc.
21.
XtraFlex 60 Aluminum Non-fibered aluminum roof
%2-1 gal/sq
ASTM D2824
Polyglass USA,
Roof Coating
coating.
Type I
Inc.
22.
XtraFlex 65 Aluminum Fibered aluminum roof coating.
1'h-2 gal/sq
ASTM D2824
Polyglass USA,
Roof Coating Fibered
Type III
Inc.
23.
XtraFlex 70 Premium
A premium white or tinted
I-1 %2 gaUsq
ASTM D6083
Polyglass USA,
Acrylic FR Roof
elastomeric acrylic based roof
Inc.
Coating
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
24.
XtraFlex 80 Emulsion
An asphalt based, non-fibered
3 gal/sq in two
ASTM D1227
Polyglass USA,
Roof Coating
clay emulsion
coats
Inc.
25.
XtraFlex 30
An asphalt cutback fibered roof
1 %2-2 gal/sq
ASTM D4479
Polyglass USA,
Bituminous Roof
coating. May be applied by
Inc.
Coating Fibered
brush or spray equipment to
rejuvenate aged BUR
26.
XtraFlex SRC 8000
A single component, white or
1.25 gal/sq
ASTM D6694
Polyglass USA,
tinted, solvent, moisture cure
Inc.
silicone coating.
27.
XtraFlex SRC 9600
A premium grade high solids,
1.25 gal/sq
ASTM D6694
Polyglass USA,
white or tinted, single
Inc.
component, moisture cure,
fluid applied silicone coating
MtAMI-DAC►E COUNTY
NOA No.: 19-0311.04
• • Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 9 of 38
EVIDENCE SUBMITTED:
Test Agency Test Name/Report
Report No.
Date
ASTM D6694
PUSA-135-02-01
05.16.14
TAS 117(B)
PUSA-202-02-01
05.08.17
FM 4470 & TAS 114
PUSA-202-02-02
05.23.17
MIAMI-DADE C UNTYM NOA No.: 19-0311.04
IIIII�FJVZRTAO MW Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 11 of 38
Primer: Apply WB -3000 at 1 gal. per 300 sq. ft.
(Optional)
Base Sheet: One ply of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex SA V
PLUS FR or XtraFlex SBS Base SA self -adhered.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
(Optional) SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See general limitation #7.)
MIAMbDADE COUNTY
NOA No.: 19-0311.04
• r Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 13 of 38
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -60 psf; (See general limitation #7.)
MIAMFDADE UNTYM NOA No.: 19-0311.04
�IIII� ' "' • Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 15 of 38
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA, XtraFlex SBS G SA,
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See general limitation V.)
in
MiAMMADE COZTY NOA No.: 19-0311.04
VIII "' • 1 Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 17 of 38
Membrane Type:
Deck Type 1I:
Deck Description:
System Type C(1):
SBS/APP
Wood, Insulated
Min. "/32" plywood ('5/32" for re -roof) or wood plank, fastened at 24" spans with 8d common
nails at 6" o.c.
All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Laver
Insulation Fasteners Fastener
Table 3 Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1.0" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Top Insulation Laver Insulation Fasteners Fastener
Table 31 Density/ft2
SECUROCK Gypsum -Fiber Roof Board
Minimum'/" thick
DensDeck Prime
Minimum'/" thick
2 with 4 or 15; 10 with 12; S 1:2 ft2
with 6,13 or 14; 7 with 8;
2 with 4; 10 with 12; 5 with 1:2 ft2
6 or 14; 7 with 8;
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels Iisted are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Primer: Apply WB -3000 at 1 gal. per 300 sq. ft.
(Optional)
Base Sheet: One ply of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex SA V
PLUS FR or XtraFlex SBS Base SA self -adhered.
PIy Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
(Optional) SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P FR, Polyflex SA P FR, Polyfresko G APP SA FR, Polyfresko G
SBS SA FR, PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP SA or XtraFlex
SBS G SA self -adhered.
KAMMADEG���NOA No.: 19-0311.04
. 0701,74 • Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 19 of 38
Membrane Type:
Deck Type lI:
Deck Description:
System Type C(2):
SBS/APP
Wood, Insulated
19/32" or greater plywood or wood plank, fastened at 24" spans with 8d common nails or wood
screws at 4" o.c.
All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Laver
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
Table 3 Density/ft'
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Top Insulation Laver
Structodek High Density Fiberboard Roof Insulation
Minimum %11 thick
DensDeck
Minimum %1' thick
Insulation Fasteners Fastener
Table 3 Density/ft'
2 with 4; 10 with 12 1:1.33 W
2 with 4; 10 with 12 1:1.33 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Primer: Apply WB -3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self -adhered base
(Optional) sheets.
Base Sheet: One ply of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex SA V
PLUS FR or XtraFlex SBS Base SA self -adhered.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
(Optional) SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA, XtraFlex SBS G SA,
self -adhered.
MIAMI•DADE COUNTY
NOA No.: 19-0311.04
• Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 21 of 38
Membrane Type:
Deck Type II:
Deck Description:
System Type C(3):
SBS/APP
Wood, Insulated
19/32" or greater plywood or wood plank, fastened at 24" spans with 8d common nails at 4" o.c.
All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
Table 31 Density/ft'
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Ton Insulation Laver
Structodek High Density Fiberboard Roof Insulation
Minimum %11 thick
DensDeck
Minimum'/" thick
Insulation Fasteners Fastener
Table 3 Density/ft'
2 with 4; 10 with 12 1:1.33 ft2
2 with 4; 10 with 12 1:1.33 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Primer: Apply WB -3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self -adhered base
(Optional) sheets.
Base Sheet: One ply of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex SA V
PLUS FR or XtraFlex SBS Base SA self -adhered.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
(Optional) SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 23 of 38
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: !9/32" or greater plywood or wood plank, fastened at 24" spans with wood screws at 6" o.c.
System Type C(4): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved
and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building
Code requirements and are field fabricated utilizing the approved membranes listed in Table 1.
One or more of the following:
Insulation Layer
Insulation Fasteners
Table 3
ENRGY 3, H -Shield, Polytherm-H, ACFoam-H, Polytherm, XtraFlex Polyiso
Minimum 1.5" thick 2 with 4; 7 with 8; 10 with
12
Fastener
Density/ft2
1:1.33 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels Iisted are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Primer: Apply WB -3000 at 1 gal. per 300 sq. ft.
(Optional)
Base Sheet: One ply of Elastoflex SA V, Elastoflex SA V FR or Elastoflex SA V PLUS, Elastoflex SA V
PLUS FR, XtraFlex SBS Base SA, self -adhered.
PIy Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR or Elastoflex SA V PLUS,
(Optional) Elastoflex SA V PLUS FR, XtraFlex SBS Base SA, self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -82.5 psf; (See General limitation #7.)
aE
ADE COUNTY
NOA No.: 19-0311.04
, Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 25 of 38
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General limitation V.)
MAMMADE COU NOA No.: 19-0311.04
IIII�I ' " • ��� Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 27 of 38
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products Iisted in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -60 psf; (See General limitation #7.)
aMLAWD=
ADEcNOA No.: 19-0311.04
.' • • Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 29 of 38
Membrane Type: SBS/APP
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24" spans with 8d ring shank nails at 6"
o.c. at edges and intermediate supports.
System Type E(2): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase, Elastoshield HT, Polyglass APP Base, XtraFlex SBS Glass Base or
XtraFlex SBS HT Base 650 sheet fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular grooved shank and 1" diameter caps spaced 6" o.c. in a
3" lap and 6" o.c. in four equally spaced staggered center rows.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
MIaMMaoE cauN-rir
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 31 of 38
Membrane Type:
Deck Type 1:
SBS/APP
Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24" spans with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase, Elastobase P, Elastoshield HT, XtraFlex SBS Glass Base or XtraFlex
SBS HT Base 650 fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 8"
o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation #7)
IAMI-DADE COUNTY
NOA No.: 19-0311.04
� . • • f �� Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 33 of 38
Membrane Type: SBS/APP
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32' or greater plywood or wood plank, fastened to supports spaced 24" o.c. and to blocking
members spaced 48" o.c. with TruFast TP #10x2-7/8" screws spaced 6" o.c.
System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase, Elastobase P, Elastoshield HT, XtraFlex SBS Glass Base or XtraFlex
SBS HT Base 650 fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 4"
o.c. in a 4" lap and 4" o.c. in four equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -97.5 psf; (See General Limitation #7)
NOA No.: 19-0311.04
MIAMMADE COUNTY
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 35 of 38
Membrane Type: SBS/APP
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24" o.c. with #80" wood
screws spaced 6" o.c.
System Type E(8): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase, Elastobase P, Elastoshield HT, XtraFlex SBS Glass Base or XtraFlex
SBS HT Base 650 fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. annular ring sharked nails and 1-5/8" tin -caps 6" o.c. in 4" lap
and 6" o.c. in four equally spaced staggered rows. Tin -caps are primed with PG 100 or
XtraFlex 10.
Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA, XtraFlex SBS G SA,
self -adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design -97.5 psf; With Elastoflex SA V or Elastoflex SA V FR (See General limitation #7.)
Pressure: -112.5 psf; With all other base sheet options (See General limitation #7.)
MtAWDADEcoUNW NOA No.: 19-0311.04
�Fjymeyjg Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 37 of 38
&-=B
U 'tu-.r..- h Englneerlrvt
Spedaifiy Strur-tUrdl EngtnE+erincl CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report
"Ultra HT Wind & Water SealTM»
Roof Underlayment
Manufacturer:
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
for
Florida Product Approval
# FL 11842.3 R4
Florida Building Code 6th Edition (2017)
Method: 1- D
Category:
Sub - Category:
Product:
Description:
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 17 -131 -UHT -ER
(Revises 15 -115 -UHT -ER, FL11842.5 R3)
Date: 07/09/17
Contents:
Evaluation Report Pages 1— 5
Roofing
Underlayment
"Ultra HT Wind & Water SealTm"
Self -Adhered Underlayment
Facsimile of digital copy signed by
James L. Buckner, P.E.
Electronically signed and sealed documents shall
comply with the provisions of FAC Rule 61615-23.
2017.08.2814:49:18 -04'00'
CBUCK, Inc. dba CBUCK Engineering
Phone: (561) 491-9927 - Email: cbuck0cbuckinc.net - Website: www.cbuckinc.net
Business:1374 Community Dr., Jupiter, FL 33458 - Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062
CBU r,
' 'C' L-nciineering
FL #: FL 11042.3 R4
Date: 07/09/17
Report No':17-131-UHT'ER
Page 2 of 5
SPL=clafti Structural r=ngineering CBUCK, Inc. Certificate of Authorization #8064
Product Name:
Product
Product Sub -Category
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43012
(740) 622-2645
"Ultra HT Wind & Water Seal-"
Roofing
Underlayment
Compliance Method: State Product ApprovalRule G1G2O-3.005(1)h8
Product : "Ultra HTWind & WaterSealm" is membrane composed ofawhite,
non-sUpcnzss-laninatedpok/nerfi|o\bminata toarubberized asphalt adhesive
with a split release liner designed for use as a roof underlayment i
temperature conditions.
Product Material I Material Type: GtVreneButadiene Stvrene/S8�\
Standards: K4ateha|''co 'pk/m/bh&�TKHO '�O ---'
shall"*�^ z**UperRoridaBuU6inmCodeFQCGthEditbon
(2017), Chapter 15.
Product
Dimension(s) Roll Size: 36in. x67ft. rolls
Thickness: 4Smils (nonm/Oa/)
Substrate(s): "U|tns HT Wind & Water Sea|"°" has been evaluated for application to the
following substrates (Design of support is outside the scope of this evaluation):
m Plywood ~
• Dens Deck
Installation: General Installation Instructions:
"Ultra HTWind & Water SeayTm"shall be installed in accordance with the attached
installation method and in compliance with applicable code sections of the F8C
6th Edition (2017), subject to the Limitations and Conditions of Use listed in this
Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's
installation instructions esasupplemental guide for attachment.
FL #: FL 11842.3 R4
Date: 07/09/17
CBLUCK EnglneerinQReport No.: 17-131-UHT-ER
Page 3 of 5
SpecialftJ Structural Engineering ceuCK, Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a — Specification Self -adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 6+th Edition (2017) for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida Building
Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product limitations and • Deck shall be in compliance with applicable building code.
Conditions of Use: • Minimum slope shall be 2:12 or greater.
* Installation is limited to use with approved roof coverings that are
mechanically fastened through the underlayment and is attached to the
sheathing or rafters.
• Not to be applied over active solvents or sealants, EPDM rubber or products
containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
General Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 611320-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
Date: 07/09/17
CIZU L-nc=wnepring Report No.: 17 -131 -UHT -ER
psl3em�aicas71fti—s- iructural
E—nginserllnQ CBUCK, Inc. Certificate of Authorization #8064
not a design certification of code compliance construction submittal
per F8[section 1O7,for any individual structure, site specific
orpermit design.
w Design ofsupport system isoutside the scope ofthis report.
w Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included inthis evaluation.
* This evaluation report does not evaluate the use mfthis product for use inthe
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
'hVm(ocbxHuniceneZonecmdesection,(Dadef\BrowardCnuoties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 81G20-3 (3) for
manufacturing under aquality assurance program audited 6vanapproved ' a/�v
assurance entity through Keystone Certifications, Inc.(F8C Organization |D#QUA
1824).
Referenced Data: I. ASTM D197O-01Test
BvPRI Construction Materials Teohnokoe�s Inc.(FBCOr8an�at�o|D#T8T16SG) -
Report No. K8FKN-O39'D2-01,Date: 8/15/13
2. Equivalency ofTest Standard Certification
8vJames LBuckner, P.E@Q3UCKEngineering
(FBC Organization # ANE 1916)
3. Qua lity Assurance
Keystone Certifications, Inc. (F8COrganization !D#QUA 1QZ4)
MFM Building Products Corp. Licensee #335
4. Certification ofIndependence
ByJames L. Buckner, P.E. @ CBUCK Engineering
M 9: K 1184'1.3 K4
Date: 07/09/17
C:
j ri Report No.: 17 -131 -UHT -ER
Page 5 of 5
S{Peclalty Structural Enc,)ineL=rinq Caucx, Inc. Certificate ofAuthorization #/8064
MFM Building Products Corp.
Ultra HT Wind & Water Seal
Self -Adhered Roofing Underlayment
General Installation Instructions:
• Product to be applied directly to a clean dry surface.
• Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer.
• Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into
place onto roof deck.
• Adhesive is pressure -activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or
rubber roller to seams and overlap.
• Overlap end laps a minimum of 6". Side laps must be a minimum of 3".
• Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight.
• Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature
of: 50° F
• Not to be applied overactive solvents or sealants, EPDM rubber or products containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
"Ultra HT Wind & Water SealT-" shall be installed in accordance with the attached installation method and in
compliance with applicable code sections of the FBC 6th Edition (2017), subject to the limitations and
Conditions of Use listed in this Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Product Illustrations
+; ULTRA HT
WIND & WATER SEAL`"
.�
,:PTV- -C F
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads
DESIGN PRESSURE*
ROW SPACING
FASTENER SPACING (ALONG Panel width)
FASTENER SIZE
Reference Data:
See Fastener attachment specirications above
METHOD
-86 PSF
16" o.c.
12" O.C.
#9
ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report DtS893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY -UL 1897-04 is equivalent to test standard UL 1897-1� *Design pressure margin of safety 2.1
tti!lr��
r'3p•,
Y,
Locke Bowden, P.E. does not have, not will acquire a financial in 1��_�i� a ' " " ' ��'
under this evaluation. �� �4nn m►facturing or distributing products
Locke Bowden, P.E. is not owned, operated, or controlled by any cowipanV,0tnbf 0faaturer, or distributing products under this
report. y` e
Sf'! J'�G e
. w rTr-
�t �3f
110
A I
0 N A L
1
METHOD 2
METHOD 3
METHOD 4
-93.5 PSF
-101 PSF
-228 PSF
16" O.C.
St, O.C.
6" ox.
12" ox.
12" O.C.
12" ox.
#10
#10
#10
f-11-1 IUZZ.1 -)V crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities W/jurisdiction is allowed by other reistered
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. gengineers.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners -
#9 - 1-1/2" Mtn. or
#10 - 1-1/2• Min. PGr 7Abk -A- for Row5-V Crinv Roof Pend
SPacing and Design Pressures
Hex Washer Head Wood screws
:1
15(32'Or greater PlYwood, or
Wood Oank
OPTIONAL STRIATIONS
Nominal �12"
O.C.
Panel Profile
.Nominal 12"
O.C.
Fasten x ste1n
9
9 1-1/2" Min. or #10 x 1-1/2' Min. per
-Table "An Hex Washer Head Screw
Panel Spaced 12" o.c. across the Panel Width
Overlap Refer to Table "A" for Spacing Along Panel
Length
Deck -15/32" or greater
Plywood, or
- Wood plank
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507,1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Install Details: Table A Allowable Loads METHOD 1 FastenerIMETHODachment Specifications above
DESIGN PRESSURE* 2 METHOD 3 METHOD 4
-86 PSF PSF -101 PSE 228 PSF
ROW SPACING 16" o.c.FASTENERSPACING (ALONG Panel width) 12" o.c. o.c. 2`" oc. 1 ox. FASTENER SIZE c.
#9 #10 1 #10 1 #10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL S80-06 & 1897-041 Test Report X893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/is
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY -UL 1897-04 is equivalent to test standard UL 1897-1i! t t ► r
*Design pressure margin ofsafety 2:1
Locke Bowden, P.E. does not have, not will acquire a financial in j`A 'r° �Yy ''
under this evaluation.`cQ$.anm��G;facturing or distributing products
:� � :�
Locke Bowden, P.E. is not owned operated, or controlled b a coir! a "'ifiaiatturer'or drstributin
report.49 OA
p Y tlil �p0 '-
° o _ g products under this
° A' a<<
S J Tc °4
0
rr �L aa1fb A s o° d am \t•�~ �
Limitatio ns: I-LIfUZ2.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
1-. Undeil ayment to be compliance with current Florida Building Code (FBC)2017 61h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities W/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th'ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
— Fasteners '
#9-1412- Mi.. or
#10 x 1.112* Min. PVZWe -A& for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
AF
AID
. . . . . . . . . . .
Dedc
- 15f32'or nkgreater PVwood, or
- Wood pla
318" 12" 24-
OPTIOPOL STRIATIONS
Nominal 12"
O.C.
Panel Profile
Nominal 1211
O.C.
Fasten I
A9 _x1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Panel Spaced 12" o.c. across the Panel Width
Overlap Refer to Table "All for Spacing Along Panel
Length
Deck -15/32" or greater
Plywood, or
-Wood plank
Palm City, FL 34990
(7721872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" ox.
12" O.C.
12" ox.
12" ox.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report DS893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY -UL 1897-o4 is equivalent to test standard UL 1897-1� *Design pressure margin of safety 2.1
Locke Bowden, P.E. does not have, not will acquire a financial in,� 4.
a`,tgarl�+m facturing or distributing products
under this evaluation. .0
Locke Bowden, P.E. is not owned, operated, or controlled by any coApanVorni flifatturer, or distributing products under this
report. " •
S 4'T
- Wi
jjk'66 .. ;71* 7
'%oNa�`
'' J�: to _ .� X11►�'•
FL17022.1 5V Limitations:' ` Steell 24"
"~�=" �canex ~u»emmomm
1, Underlayment iobacompliance with current �"�'—F�hdoBui�noCode'B~/2"
170med2.Minimum slope bzbe compliant vdhF�r�oBuUdino Code 2«176th oo`and per with
Manufacturer's instaUotionreference.3'pnoduntaan*conoUa"t.muu*"eoyFlohdo pnzouutapproval per Rule 81G2U-3. ' Method: 1'D4'Engineering analysis/ur"project specific approval by local authorities w/jurisdiction is allowed by other registered e»gineen
e'5.F/nac|ooaificationioncdpartofthksaccepbanoe'8h rdiaphraQnve|u-- areouto~~ this report.
8'Support framing incompliance xF8C2O17Gmed'.Chapter 22 for Steel, Chapter 2^ for Wood and Chapter 1Gfor
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
--- Fasteners -
#9`1-1urMin. m
Nominal 1211
Panel Profile
Nominal 1211
Fasten I
Table "A" Hex V%sher Head Screw
Panel Spaced 12" o.c. across the Panel Wdth
Overlap Refer to Table "A" for Spacing Along Panel
Length
Deck- 15/32" or greater
Plywood, or
-Wood plank
Palm City, FL 34990
(772)872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment
Install Details: Table A AllowableELoadsMETHOD1
DESIGN PRESSURE*
ROW SPACING
FASTENER SPACING (ALONG Panel w
SIZE
-_-
...•..■..�
METHOD 2
-93.5 PSF
METHOD 3
METHOD 4
-101 PSF
-228 PSF
16" o.c.
12" o.c.
#10
8" o.c.
6" o.c.
12" o.c.
12" o.cFASTENER
#10
410
LOU LO. MM-rin MI UKAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report C(5893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY -UL 1897-04 is equivalent to test standard UL 18971�*Design pressure margin of safety 2.1
Locke Bowden, P.E. .a a;.
under his evaluation. Ma
not have, not will acquire a financial inert ma facturing or distributing products
Locke Bowden, P.E. is not owned, operated, or controlled b colicmmil aaturer, or distributin
report. y a` pa� g products under this
el
;71F°$},
'r `'' ONA L
FL17022^1 5V Crimp (��K�dkRf�mol �AUxA�-x-n~__�=
0nde�ono: --� `--~�^ ~~~��"»' �� ��nd� M��nPaneU ~e%a0Us
1� � toba.'v�hcurrent FkohdoQuUdhnoCode y-oC/2�u
17Gm2. NUnhnunslope to be compliant with Building Code 2017 �=ed'
aU"o»dper«dh
-
installation rafarenoe.3^p«oductaona_-.r.nt.~"a",ofFkzhda product approvalper Rule G1G2O-3'�onp||anoe8athod'1-O4. Engineering analysis for "project specific approval bvlocal auth authorities W^nodk±ioniaaUo«edb»otherregioteredenDinaer
s.
5. Fire classificationionopartofthksaomeptanoe'Shear diaphragm values are outside this report.
S'Support framing incompliance m/F8C 2D176th md"Chapter 22 for Steel, Chapter 23for Wood and Chapter 16for
Structural Loading.
7. This report does not imply warranty, installation, recommended product.use outside of this report.
— Fasteners '
Nominal 1211
Panel Profile
Nominal 1211
Fa ten 1
Table "A" Hex V%sher Head Screw
Panel Spaced 12" o.c. across the Panel Wdth
Overlap Refer to Table "A" for Spacing Along Panel
Length
Deck- 15/32" or greater
Plywood, or
-Wood plank