Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Inspection Docs
Englert Residence Model ASPT47D14 ASPTSERIES Air Conditioning&Heating MULTI-POSITION, MULTI-SPEED, ECM-BASED AIR HANDLER WITH INTERNAL TXV I . 1% TO5TONS I ; ® Contents Air Handler Nomenclature....................2 Heater Kit Nomenclature......................2 Product Specifications...........................3 Dimensions............................................4 Airflow Data...........................................6 Heat Kit Data..........................................8 i Wiring Diagram....................................15 t, Accessories..........................................18 Product Features • Internal factory-installed thermal expansion • Rigid SmartFrame'M cabinet valves for cooling and heat pump applications • Horizontal or vertical • Direct drive,multi-speed ECM blower motor configuration capabilities • All-aluminum evaporator coil • 21"depth for easier attic access • Coil mounting track for quick repositioning • DecaBDE-free thermoplastic drain • Optimized for use with R-410A refrigerant pan with secondary drain connections • Cabinet air leakage less than 2.0% • Screw-less sides and back helps at 1.0 inch H2O when tested in to reduce condensation when accordance.with ASHRAE standard 193 installed in humid locations • Cabinet air leakage less than 1.4% • Foil-faced insulation covers the internal at 0.5 inch H2O when tested in casing to reduce cabinet condensation accordance with ASHRAE standard 193 • Galvanized, leather grain-embossed finish • AHRI certified; ETL listed • Glue-less cabinet insulation retention • Tool-less filter access • Field Installed 3 kW—25 kW electric heater kits available � j0PARTS I _ '� _ offi t,s LIMITED ( COMPANY WRH COMPANY WRH OUALTTV SYSTEM ENVIRONMENTAL SYSTEM YEAR WARRANTY- I CEATMIEO 9Y DW GL cEMWIEO BY ONv cL Intertek '�09001� 9[so'�41� _ BBB 'Complete warranty details available from your local dealer or at www.goodmanmfg.com,To receive the 10-Year Pars Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Qu6bec. SS-GASPT www.goodmanmfg.com 6/19 Supersedes 6/18 NOMENCLATURE A S P T 18 B 1 4 AA 1 2 3 4 5,6 7 8 10 11,12 Brand Engineering A Single-piece Major/Minor Revisions Air Handler * Not used for inventory management Unit Application Refrigerant Charge C Ceiling Mount PSC Motor 4=R-410A D Downflow PSC Motor E Multi-Position Variable-Speed Motor Electrical R Multi-Position PSC Motor 1 208/240 V,1 Phase,60 Hz 5 Multi-Position EEM Motor W Wall Mount PSC Motor Cabinet Width B 17%" Cabinet Finish C 21" U Unpainted D 24%" P Painted N Uncased Nominal Capacity Range @ 13 SEER 25,29,33-2 Tons 47-3'/:Tons Expansion Device 35,37-2'h Tons 49-4 Tons F Flowrater 37,39-3 Tons 59,61-5 Tons T Expansion Valve HKS X 03 X A AA 1 2 3 4 51 6,7 Unit Type Revisions HKS Heat Kit for Engineering Revisions Air Handlers Phase Circuit Breaker A Single Phase 208 V E Three Phase 240 V X No circuit breaker B Single Phase 240 V F Three Phase 208/240 V C Circuit Breaker C Single Phase 208/240 V G Three Phase 460 V D Three Phase 208 V Heating Capacity @ 240 Volts 03 3.0 kW 15 14.4 kW Cabinet Size(MAX) 05 4.5 kW 19 19.2 kW wth 15OF limit C C Cabinet 06 6.0 kW 20 19.2 kW with 170F limit D D Cabinet 08 8.0 kW 25 25.0 kW X All Cabinet Sizes 10 9.6 kW 2 www.goodmanmfg.com SS-GASPT PRODUCT P Cl (CATIONS NOMINAL RATINGS Cooling(Btu/h) 24,000 24,000 24,000 28,000 30,000 36,000 36,000 42,000 48,000 60,000 42,000 18,000 60,000 BLOWER Diameter 9'/" 9%" 105/" 9%2" 9%" 105/" 10%" 10%" 10%" 10%" 10%8' 11/16 1115/6" Width 6" 6" 8" 6" 6" 8" 8" 10%" 8" 10%" 10%" 105/8' 10%8' COIL CONNECTIONS Liquid %11 %11W,%" %8' %. ��� �" W %11 Suction /11 Y" Y"%' '%ee8 � �7/8' 8 Coil Drain Connect(FPT) %" %" %" %" %" %" 3/" %" %" %" %" %" /<' 3 ELECTRICAL DATA Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/23 208/230 08/230 208/230 Minimum Circuit Ampacity 5.8/5.8 5.8/5.8 4.9/4.9 5.6/5.6 5.6/5.6 5.6/5.6 4.9/4.9 4.9/4.9 7.1/7.1 7.9/7. 5.6/5.6 .6/8.6 8.6/8.6 Max.Overcurrent Device 15/15 1S/15 15/15 15/15 15/15 15/15 15/15 15/15 15/1S 15/15 15/15 5/15 15/15 (Amps) Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 2S3 253 253 253 253 2S3 Blower Motor Full Load Amps(FLA) 4.6 4.6 3.9 4.5 4.5 4.5 3.9 3.9 5.7 6.3 4.5 6.9 6.9 Horsepower(HP) % 3/< 3/ '/< 3/ % 3/< 3/ '/, 1 % 1 1 SHIP WEIGHT(LBS.) 116 129 118 129 129 144 118 144 125 144 155 167 167 "Airflow rate @.3 static Note:Assumes dry coil;SUM correction for wet coil=4%(208V/240V) SS-GASPT www.goodmanmfg.com 3 DIMENSIONS 3.08" (7.82 cm) 1.63" (4.13 cm) 1.45" (3.68 cm) 21" 4.50" 9.21"— (11.43 cm) ' 2.93" (19.1 cm) 2.91" (7.44 cm) 5.2" (7.391 cm) �) � (13.3 cm) 3.1" 11.3" —B (7.9 cm) (28.70 cm) DRAIN PORT DETAIL 1,4^ 55" .55" I' �I—.55" (3.6 cm) (1.40cm) (1.40 cm) PLASTIC— BREAKER �U (4.6 cm) COVER — LOGO LOCATION- 2.17" r (5.51 cm) SUCTION TUBE A LIQUID LINE L ,o, INLET— G— _—_ TUBE I SEE DRAIN PORT DETAIL, I D \ E r/ H I 1.73" 7F — 1.73" 1" 19.5"(49.5 cm) .55" (4.39 cm) INLET (4.39 cm) (2.54 cm) INLET (1.40 cm) (FRONT VIEW) (RIGHT SIDE VIEW) 7SPT29Bl4' 45 16% 17% 15'/4 12 14 9 12 3/4 53Y22 16% 17Y2 235/8 20Y2 14 9 7% ASPT33C14* 49 19%8 21 179/16 14% 17'/= 109/16 12% ASPT35B14* 45 16% 17% 15'/4 12 14 9 123/4 ASPT37B14* 53% 16% 17% 235/8 20Y2 14 9 7% ASPT37C14* 53% 193/8 21 2113/16 18%2 17Y22 107/8 6% ASPT39C14* 49 19% 21 179/16 14% 17Y2 109/16 12'/ ASPT47C14* S3% 193/. 21 211i/16 18% 17Y2 102/8 6% ASPT47D14* 53'/2 233/8 24Y2 21% 185/16 21 12% 6'/s ASPT49C14* 49 193/8 21 179/16 14% 17Y2 109/16 12'/2 ASPT49D14* 58 233/8 24Y2 26'/8 22'/8 21 12% 13'/4 .ASPT59C14* 53% 193/s 21 2113/6 18% 17% 107/8 6%e ASPT61D14* 58 233/8 24% 26% 22%8 21 12% 13'/4 4 www.goodmanmfg.com SS-GASPT DIMENSIONS (CONT.) 412"(11.43 cm) 7 3/16°(182 6 cm) 6 1!8"(15.56 cm) 4 5/16'(4.31 cm) 21'(55.88 cm) N 2 118°(5.40 cm) 9 114'(23.50 cm) 11 5/16°(28.73 cm) J � 7 12°(19.05 cm) 5 118'(13.02 cm) 1 518'(4.13 cm) C 3 118"(7.94 cm) 1/2"(1.27 cm) 518°(1.59 cm) I- B� 5/8'(1.59 cm) 13/8'(3.49 cm) Tr 1 5/16'(3.33 cm) L HORIZONTAL DRAIN PORT DETAIL t 3/4'(4.45 cm) 2 11/16'(6.83 cm) 3 1116'(7.78 cm) 1314"(4.45 cm) A o SUCTION TUBE G LIQUID LINE 2 15116°(7.461 cm) o SEE HORIZONTAL INLET TUBE--4 1 DRAIN PORT DETAIL 3 314"(9.53 cm)—,— t 1 SW(4.13 cm 10 3/16°(25.88 cm) D VERTICAL DRAIN PORT DETAIL SEE VERTICAL RAIN PORT DETAIL H , 1'(2.54 cm)--IL-19.5•(49.53 cm)A L 9/16(1.43 cm) 1 13/16"(4.60 cm) F 1 13116'(4.60 cm) INLET INLET (RIGHT SIDE VIEW) (FRONT VIEW) SS-GASPT www.goodmanmfg.com 5 AIRFLOW DATA STATIC PRESSURE(IN W.C) 1 640 585 580 545 510 490 410 340 280 2 800 765 725 700 670 645 595 565 490 ASPT 3 840 805 800 760 740 700 670 625 580 25B14A8 4 985 950 920 885 850 815 800 760 725 5 1,475 1,440 1,400 1,375 1,335 1,305 1,270 1,240 1 1,150 1 595 590 565 530 505 455 380 305 260 2 790 775 745 705 665 625 58S 515 445 ASPT 3 865 820 790 770 735 695 645 595 530 29B14AB 4 1,015 980 9S5 925 880 840 795 770 720 5 1,505 1,465 1,430 1 1,410 1,385 1,350 1,315 1,285 1,220 1 865 685 615 540 480 410 335 270 215 2 935 875 820 785 720 655 600 550 490 ASPT 3 1110 1050 1000 955 905 855 795 760 710 33C14BA 4 1355 1310 1260 1220 1180 1135 1095 1055 1005 5 1560 1515 1475 1430 1395 1370 1 1330 1295 1260 1 875 845 845 825 795 780 730 680 630 2 985 945 925 915 905 880 845 795 760 ASPT 3 1,070 1,025 990 985 980 960 940 905 860 35614A8 4 1,245 1,205 1,170 1,135 1,115 1,115 1,100 1,090 1,035 5 1,310 1,275 1,230 1,190 1,155 1,135 1,085 1,080 1,040 1 1,025 985 945 910 875 830 795 735 690 ASPT 2 l,iSo 1,105 1,065 1,025 995 950 915 870 825 37B14AB 3 1,240 1,200 1,160 1,120 1,085 1,050 1,010 970 925 4 1,425 1,400 1,355 1,320 1,290 1,250 1,215 1,180 1,145 S 1,490 1,455 1,415 1,390 1,355 1,320 1,285 1,250 1,205 1 980 935 895 860 825 800 755 710 665 ASPT 2 1,125 1,075 1,045 1,000 965 930 880 845 820 37C14AC 3 1,235 1,190 1,155 1,120 1,085 1,045 1,005 965 920 4 1,485 1,450 1,425 1,390 1,355 1,315 1,275 1,230 1,190 5 1,565 1,535 1,510 1,480 1,240 1,390 1,365 1,320 1,280 1 865 685 615 540 480 410 335 270 215 2 935 875 820 785 720 655 600 550 490 ASPT 3 1110 1050 1000 955 905 855 795 760 710 39C14BA 4 1355 1310 1260 1220 1180 1135 1095 1055 1005 5 1560 1 1515 1475 1430 1395 1370 1 1330 1295 1260 1 955 895 855 840 780 735 675 615 560 2 1,100 1,050 1,005 965 925 870 815 770 705 ASPT 3 1,205 1,160 1,120 1,075 1,035 990 940 885 830 47C14BA 4 1,445 1,410 1,365 1,320 1,275 1,235 1,190 1,140 1,095 1 1,055 1,015 950 895 830 785 730 680 620 2 1,210 1,165 1,110 1,070 1,015 960 900 840 785 ASPT 3 1,335 1,290 1,250 1,205 1,145 1,100 1,050 980 910 47D14AC 4 1,625 1,580 1,530 1,495 1,455 1,405 1,350 1,295 1,230 S 1,720 1,670 1,625 1,580 1,540 1,490 1,435 1,390 1,325 2 1465 1420 1380 1355 1315 1280 1240 1195 1155 ASPT 3 1505 1465 1425 1390 1355 1330 1290 1245 1205 49C14AC 4 1600 1565 1530 1490 1460 1425 1385 1365 1290 5 1690 1660 1625 1 1585 1555 1520 1 1485 1400 1250 1 1,485 1,435 1,380 1,320 1,265 1,200 1,230 1,015 930 2 1,570 1,525 1,480 1,430 1,370 1,31S 1,235 1,155 1,035 ASPT 49D14AC 3 1,680 1,600 1,570 1,555 1,475 1,430 1,360 1,280 1,185 4 1,800 1,765 1,715 1,670 1,625 1,590 1,510 1,465 1,390 5 2,215 2,160 1 2,120 2,085 1 2,040 1 2,000 1,970 1 1,930 1 1,865 See notes ona � ge 7. 6 www.goodmanmfg.com SS-GASPT AIRFLOW DATA (CONT.) 0.5 0 . 0.7 0: r • 1.0 1 .1,370 1,330 1,295 1,255 1,215 1,180 1,140 1,100 1,060 2 1,535 1,500 1,465 1,430 1,405 1,370 1,335 1,300 1,210 ASPT 3 1,680 1,645 1,615 1,575 1,545 1,510 1,440 1,330 1,205 59C14AC 4 1,905 1,855 1,780 1,690 1,605 1515 1,425 1,330 1,205 5 1,940 1,855 1,775 1,700 1,605 1,505 1,420 1,320 1,205 1. 1,545 1,495 1,440 1,390 1,335 1,260 1,180 1,080 1,030 2 1,745 1,695 1,625 1,575 1,525 1,475 1,400 1,360 1,275 ASPT 3 1,905 1,855 1,815 1,770 1,725 1,670 1,635 1,575 1,Soo 61D14AC 4 2,155 2,105 2,090 2,045 2,000 1,970 1,935 1,890 1,830 S 2,340 1 2,310 1 2,265 1 2,220 2,185 2,165 1 2,120 2,080 1 2,030 NOTES • The chart is for information only.For satisfactory operation,external static pressure must not exceed value shown on rating plate. • Use the CFM adjustment factors of.98 for horizontal left,.95 for horizontal right&.96 for downflow orientations. Assumes dry coil with filter in place. • All models are shipped from the factory with the speed tap set on T4. • Assumes dry coil;SCFM correction for wet coil=4% • All ASPT models are shipped from the factory with the speed tap set on T4. SS-GASPT www.goodmanmfg.com 7 HEAT KIT DATA ASPT25B14AB 0/0 5.8/5.8 15/15 - - - HKSX03XC-208 V 10.8 19 20 --- --- --- - --- HKSX05XC-208 V 17.3 27 30 - --- --- H KSX06XC- --HKSX06XC-208 V No Breaker 21.6 33 35 --- --- --- --- -- HKSX08XC-208 V 28.8 42 45 --- - --- --- - HKSXIOXC-208 V 34.6 49 50 --- --- - -- - HKSC05XC-208 V 17.3 27 30 --- --- --- --- --- HKSC08XC-208 V Breaker 28.8 42 45 --- --- --- --- --- HKSCIOXC-208 V 34.6 49 50 --- --- --- --- --- HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20.0 31 35 --- - --- --- --- HKSX06XC-240 V No Breaker 25 37 40 --- --- --- --- --- HKSX08XC-240 V 33.3 47 50 --- - --- --- --- HKSXIOXC-240 V 40.0 56 60 --- -- --- --- --- HKSC05XC-240 V 20.0 31 35 --- --- --- --- --- HKSC08XC-240 V Breaker 33.3 47 50 - --- --- --- --- HKSCIOXC-240 V 40.0 56 60 --- --- --- ASPT29B14AB 0/0 5.8/5.8 15/15 --- --- --- --- --- H.KSX03XC-208 V 10.8 19 20 --- --- --- --- --- HKSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V No Breaker 21.7 33 35 --- --- --- H KSX08XC- --HKSXO8XC-208 V 28.9 42 45 --- --- --- --- --- HKSXIOXC-208 V 34.7 49 50 --- --- --- --- -- HKSC05XC-208 V 17.3 27 30 --- --- --- --- --- HKSC08XC-208 V 28.9 42 45 --- --- --- --- --- Breaker HKSCIOXC-208 V 34.7 49 50 --- --- --- - --- HKSCI5XA-208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20 31 35 --- --- --- --- H KSX06XC- --HKSX06XC-240 V No Breaker 25 37 40 -- --- --- --- --- HKSX08XC-240 V 33.3 47 50 --- --- --- - HKSXIOXC-240 V 40 56 60 - -- -- -- - HKSC05XC-240 V 20 31 35 --- --- --- --- --- HKSC08XC-240 V 33.3 47 50 --- --- --- --- --- Breaker HKSCIOXC-240 V 40 56 60 --- --- --- --- --- HKSCI5XB-240 V 40 56 60 20 25 25 81 90 ASPT33C14BA 0/0 4.9/4.9 15/15 --- --- --- --- --- HKSX03XC-208 V 10.8 18.4 20 --- - - -- HKSX05XC-208 V 17.3 27 30 --- --- - --- --- HKSX06XC-208 V No Breaker 21.7 32 35 --- --- --- --- --- HKSX08XC-208 V 28.9 41 45 --- - - --- --- HKSXIOXC-208 V 34.7 48 50 --- --- = --- --- HKSC05XC-208 V 17.3 27 30 --- --- --- --- HKSC08XC-208 V Breaker 28.9 41 45 --- --- --- --- HKSCIOXC-208 V 34.7 48 50 --- --- --- --- --- HKSCI5XB 3-208 V 34.7 48 50 17.3 21.7 25 69.9 70 See notes on page 14. 8 www.goodmanmfg.com SS-GASPT HEAT Kir DATA (CONT.) HKSX03XC-240 V 12.5 21 ' 257-- 0HKSX05XC-240 V 20 29.9 3 --- --- --- --- HKSX06XC-240 V No Breaker 25 36.1 40 -- --- --- --- HKSX08XC-240 V 33.3 46.5 50 --- --- --- --- -- HKSXIOXC-240 V 40 54.9 60 -- - - HKSC05XC-240 V 20 29.9 30 --- --- --- HKSC08XC-240 V Breaker 33.3 46.5 50 --- --- --- --- --- HKSCIOXC-240 V 40 54.9 60 --- --- --- --- --- HKSCISXB-240 V 40 54.9 60 20 25 25 79.9 80 ASPT35B34AB 0/0 S.6/5.6 15/15 --- --- --- --- --- HKSX03XC-208 V 10.8 19 20 --- -- -- -- HKSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V 21.7 33 35 --- --- --- --- No Breaker HKSX08XC-208 V 28.9 42 45 --- --- --- --- --- HKSXIOXC-208 V 34.7 49 50 --- --- --- --- --- HKSXISXC-208 V 34.7 49 50 --- --- --- - HKSC05XC-208 V 17.3 27 30 --- -- --- --- --- HKSC08XC-208 V 28.9 42 45 --- --- --- --- Breaker HKSCIOXC-208 V 34.7 49 50 --- --- --- --- --- HKSCISXC-208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20.0 31 35 --- --- --- --- --- HKSX06XC-240 V 25 37 40 --- --- --- - - No Breaker HKSX08XC-240 V 33.3 47 50 -- -- -- -- - HKSXIOXC-240 V 40.0 56 60 -- - - - HKSXISXC-240 V 40 56 60 --- --- --- --- --- H KSC05XC-240 V 20.0 31 35 --- --- --- --- --- HKSC08XC-240 V Breaker 33.3 47 50 --- - --- --- --- HKSCIOXC-240 V 40.0 S6 60 --- --- --- --- --- HKSCISXC-240 V 40.0 56 60 20 25 25 81 90 ASPT37B14AB 0/0 5.6/5.6 15/15 --- --- --- --- --- HKSX03XC-208 V 10.8 19 20 --- --- --- --- --- HKSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V No Breaker 21.7 33 35 --- --- --- --- --- HKSX08XC-208 V 28.9 42 45 --- --- --- --- --- HKSXIOXC-208 V 34.7 49 50 --- - --- --- --- HKSC05XC-208 V 17.3 27 30 --- --- --- --- --- HKSC08XC-208 V 28.9 42 45 --- --- --- --- --- Breaker HKSCIOXC-208 V 34.7 49 50 --- --- --- --- --- HKSCISXA-208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20 31 35 - --- --- --- --- HKSXO6XC-240 V No Breaker 25 37 40 - - --- --- --- HKSX08XC-240 V 33.3 47 50 --- --- --- --- --- HKSXIOXC-240 V 1 1 40 1 56 1 60 1 - - - - - See notes on page 14. SS-GASPT www.goodmanmfg.com 9 HEAT KIT DATA (CONT.) HKSC05XC-240 V 20 31 35 --- --- --- --- HKSC08XC-240 V Breaker 33.3 47 50 --- --- - --- HKSCIOXC-240 V 40 56 60 - - --- --- HKSC15XB-240 V 40 56 60 20 25 25 81 90 ASPT37C14BA 0/0 5.6/5.6 15/15 --- --- --- --- --- HKSX03XC-208 V 10.8 19 20 --- - --- --- HKSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V No Breaker 21.7 33 35 --- -- -- - -- HKSX08XC-208 V 28.9 42 45 --- --- - --- --- HKSX10XC-208 V 34.7 49 50 --- -- --- --- --- HKSC05XC-208 V 17.3 27 30 --- --- --- --- --- HKSC08XC-208 V 28.9 42 45 --- --- --- --- --- HKSCIOXC-208 V 34.7 49 50 --- --- --- --- --- Breaker HKSCISXA-208 V 34.7 49 50 17.3 22 25 71 80 HKSC19CA-208 V 34.7 49 50 34.7 43 45 92 100 HKSC15XF-208 V A 0 5.6 15 30 38 40 --- --- HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20 31 35 - - --- --- --- HKSX06XC-240 V No Breaker 25 37 40 --- --- --- --- --- H KSXOBXC-240 V 33.3 47 50 -- -- --- -- -- HKSX10XC-240 V 40 - 56 60 - - - --- --- HKSC05XC-240 V 20 31 35 --- --- --- --- --- HKSC08XC-240 V 33.3 47 50 --- --- --- --- --- HKSCIOXC-240 V 40 56 60 --- --- --- --- --- Breaker HKSC15XB-240 V 40 56 60 20 25 25 81 90 HKSC19C6-240 V 40 56 60 40 50 50 106 110 HKSC15XF-240 V^ 0 5.6 15 34.6 43 45 --- --- ASPT39C14BA 0.0/0.0 4.9/4.9 15/15 --- --- --- --- -- HKSX03XC-208 V 10.8 18.4 20 --- --- --- --- -- HKSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V No Breaker 21.7 32 35 --- --- - -- -- H KSX08XC-208 V 28.9 41 45 --- --- HKSX10XC-208 V 34.7 48 50 --- --- --- --- --- HKSC05XC-208 V 17.3 27 30 --- --- --- --- --- HKSC08XC-208 V 28.9 41 45 --- --- --- --- HKSCIOXC-208 V 34.7 48 50 --- --- --- --- --- Breaker HKSC15XB 3-208 V 34.7 48.2 50 17.3 21.7 25 69.9 70 HKSC19CH-208 V 34.7 48.2 50 34.7 43.3 45 91.5 100 HKSC15XF-208 V A 0 4.9 15 30 37.5 40 --- --- HKSX03XC-240 V 12.5 21 25 --- - --- --- --- HK5XO5XC-240 V 20 29.9 30 -- --- --- -- - HKSX06XC-240 V No Breaker 25 36.1 40 - - - - HKSX08XC-240 V 33.3 46.5 50 --- --- --- --- --- HKSX10XC-240 V 40 1 54.9 1 60 1 -- -- --- -- - See notes on page 14. 10 www.goodmanmfg.com SS-GASPT HEAT KIT DATA (CONT. HKSC05XC-240 V 20 29.9 30 --- --- - --- --- HKSC08XC-240 V 33.3 46.5 50 --- --- - H KSCIOXC-240 V 40 54.9 60 --- --- --- --- Breaker HKSC15X6-240 V 40 54.9 60 20 25 25 79.9 80 HKSC19C6-240 V 40 54.9 60 40 50 50 104.9 110 HKSC15XF-240 V A 0 4.9 15 34.6 43 45 ASPT47C14BA 0/0 4.9/4.9 15/15 --- --- --- -- HKSX03XC-208 V 10.8 18.4 20 --- --- - --- --- HKSX05XC-208 V 17.3 27 30 --- -- - -- - HKSX06XC-208 V No Breaker 21.7 32 35 --- --- -- -- HKSX08XC-208 V 28.9 41 45 - --- --- --- - ' HKSXIOXC-208 V 34.7 48 50 --- --- -- -- -- HKSC05XC-208 V 17.3 27 30 --- - --- --- --- HKSC08XC-208 V 28.9 41 45 --- --- --- --- --- HKSCIOXC-208 V 34.7 48 50 --- --- --- --- --- Breaker HKSCISXA-208 V 34.7 48.2 50 17.3 22 25 69.9 70 HKSC19CA-208 V 34.7 48.2 50 34.7 43.3 45 91.5 100 HKSC15XF-208 V^ 0 4.9 15 30 38 40 --- --- HKSX03XC-240 V 12.5 21 25 --- --- --- --- --- HKSX05XC-240 V 20 29.9 30 - --- --- --- --- HKSX06XC-240 V No Breaker 25 36.1 40 --- -- --- --- --- H KSXO8XC-240 V. 33.3 46.5 50 HKSXIOXC-240 V 40 54.9 60 --- --- --- --- --- HKSC05XC-240 V 20 29.9 30 --- --- --- --- --- HKSC08XC-240 V 33.3 46.5 50 --- --- --- --- --- HKSCIOXC-240 V 40 54.9 60 --- -- --- --- --- BFeakeF HKSC15X6-240 V 40 54.9 60 20 25 25 79.9 80 HKSC19C6-240 V 40 54.9 60 40 50 50 105 110 HKSC15XF-240 V A 0 4.9 15 34.6 43 45 --- --- ASPT47D14AC 0/0 5.6/5.6 15/15 --- --- --- HKSX03XC-208 V 10.8 19 20 --- --- --- --- --- H KSX05XC-208 V 17.3 27 30 --- --- --- --- --- HKSX06XC-208 V No Breaker 21.7 33 35 --- -- --- --- --- HKSX08XC-208 V X8.9 42 45 --- --- = --- --- HKSXIOXC-208 V 34.7 49' 50 --- --- --- --- --- HKSC05XC-208 V 17.3 27 30 --- --- --- - HKSC08XC-208 V 28.9 42 45 --- --- --- --- --- HKSCIOXC-208 V 34.7 49 50 --- --- --- --- --- HKSCISXA-208 V Breaker 34.7 49 50 17.3 22 25 71 80 HKSC20DA-208 V 34.7 49 50 34.7 43 45 92 100 HKSC15XF-208 V^ 0 5.6 15 30 38 40 --- --- H KSC20XF-208 V A 0 5.6 15 37.5 47 50 See notes on page 14. SS-GASPT www.goodmanmfg.com 11 HEAT KIT DATA (CONT. HKSX03XC-240 V 12.5 21 25 --- --- --- --- -- HKSX05XC-240 V 20 31 35 --- --- -- - -- HKSX06XC-240 V No Breaker 25 37 40 --- --- --- = HKSX08XC-240 V 33.3 47 50 -- --- --- -- -- HKSXIOXC-240 V 40 56 60 --- --- --- --- - HKSC05XC-240 V 20 31 35 --- --- --- --- --- HKSC08XC-240 V 33.3 47 50.. - - --- --- --- HKSCIOXC-240 V 40 56 60 --- --- --- --- --- HKSCISXB-240 V Breaker 40 56 60 20 25 25 81 90 HKSC20DB-240 V 40 56 60 40 50 50 106 110 HKSC15XF-240 V A 0 5.6 15 34.6 43 45 --- --- HKSC20XF-240 V^ 0 5.6 15 43.3 54 60 ASPT49C14AC 0.0/0.0 7.1/7.1 15/15 --- --- --- --- --- HKSX03XC-208 V --- --- --- H KSX05XC- --HKSX05XC-208 V 17.3 28.8 30 --- --- -- HKSX06XC-208 V No Breaker 21.7 34.2 35 --- --- --- --- --- HKSX08XC-208 V 28.9 43:2 45 -- -- --- -- HKSXIOXC-208 V 34.7 50.5 60 --- --- --- --- --- HKSC05XC-208 V 17.3 28.8 30 --- --- --- --- --- HKSC08XC-208 V 28.9 43.2 45 --- --- --- --- --- HKSCIOXC-208 V 34.7 50.5 60 --- --- --- --- --- Breaker HKSC15XB 3-208 V 34.7 50.5 60 17.3 21.7 25 72.1 80 HKSC19CH-208 V 34.7 50.5 60 34.7 43.3 45 93.8 100 HKSC15XF-208 V A 0 7.1 15 30 37.5 40 --- --- H KSX03XC-240 V --- --- --- - - -- -- H KSX05XC-240 V 20 32 35 --- --- --- --- --- HKSX06XC-240 V No Breaker 25 38 40 --- --- --- - -- H KSX08XC-240 V 33.3 49 50 --- --- -- --- --- HKSXIOXC-240 V 40 57 60 --- --- --- HKSC05XC-240 V 20 32 35 --- --- --- --- --- HKSC08XC-240 V 33.3 49 50 --- --- --- --- -- HKSCIOXC-240 V 40 57 60 --- --- --- --- --- Breaker HKSC15XB-240 V 40 57 60 20 25 25 82 90 HKSC19C6-240 V 40 57 60 40 50 50 107 110 HKSCISXF-240 V^ 0 7.1 1 15 34.6 43 45 1 --- --- ASPT49D14AC 0/0 8.6/8.6 15/15 --- --- --- --- --- H KSX03XC-208 V 10.8 22 25 - -- -- - --- H KSXOSXC-208 V 17.3 30.3 35 - --- --- --- -- HKSX06XC-208 V No Breaker 21.7 36 40 --- --- -- -- -- HKSX08XC-208 V 28.9 45 45 - - --- --- - HKSXIOXC-208 V 34.7 52 60 --- --- --- -- -- See notes on page 14. 12 www.goodmanmfg.com SS-GASPT HEAT KIT DATA (CONT.) HKSC05XC-208 V 17.3 30.3 35 - --- --- --- H KSC08XC-208 V 28.9 45 45 - - --- --- --- HKSCIOXC-208 V7 34.7 52 60 --- --- HKSCISXB 3-208 V 34.7 52 60 17.3 22 25 74 80 HKSC20DH-208 V Breaker 34.7 52 60 34.7 43 45 95 100 HKSCISXF-208 V A 0 8.6 15 30 38 40 --- --- HKSC20XF-208 V A 0 8.6 15 37.5 47 50 --- --- HKSC25DA-208 V 52 74 80 35 43 45 117 125 HKSX03XC-240 V 12.5 24 25 --- --- --- --- --- HKSX05XC-240 V 20 34 35 --- -- --- --- --- HKSX06XC-240 V No Breaker 25 40 40 - -- - - -- HKSX08XC-240 V 33.3 50.3 60 - --- --- --- --- HKSXIOXC-240 V . 40 59 60 --- --- --- --- --- H KSC05XC-240 V 20 34 35 --- --- --- --- --- HKSC08XC-240 V 33.3 50.3 60 --- --- -- --- --- H KSCIOXC-240 V 40 59 60 --- --- --- --- --- HKSCISXB-240 V 40 59 60 20 25 25 84 90 Breaker HKSC20DB-240 V 40 59 60 40 SO 50 109 110 HKSCISXF-240 V A 0 8.6 15 34.6 43 45 --- --- HKSC20XF-240 V A 0 8.6 15 43.3 54 60 --- --- HKSC25DB-240 V 60 84 90 40 50 50 134 150 ASPT59C14AC 0.0/.0.0 7.9/7.9 15/15 --- --- --- --- --- H KSX03XC-208 V 10.8 21 25 --- --- --- --- H KSX05XC-208 V 17.3 30 30 --- --- --- H KSX06XC- --HKSX06XC-208 V No Breaker 21.7 35 35 -- -- --- --- -- H KSX08XC-208 V 28.9 44 45 - - --- --- - HKSXIOXC-208 V 34.7 51 60 - - --- - HKSC05XC-208 V 17.3 30 30 - -- --- --- HKSC08XC-208 V 28.9 44 45 --- - --- --- --- HKSCIOXC-208 V 34.7 51 60 --- --- --- --- --- Breaker HKSC15XB 3-208 V 34.7 51 60 17.3 22 25 73 80 HKSC19CH-208 V 34.7 51 60 34.7 43 45 95 100 HKSCISXF-208 V A 0 7.9 15 30 38 40 --- --- H KSX03XC-240 V 12.5 24 25 --- --- --- --- --- HKSX05XC-240 V 20 33 35 - -- -- --- --- HKSX06XC-240 V No Breaker 25 39 40 --- --- --- --- --- HKSX08XC-240 V 33.3 5d 50 --- --- -- --- --- HKSXIOXC-240 V 40 58 60 - --- --- =-- --- H KSCOSXC-240 V 20 33 35 --- --- --- --- --- HKSC08XC-240 V 33.3 50 50 --- --- --- -- -- HKSCIOXC-240 V 40 58 60 --- --- --- --- --- Breaker HKSCISXB-240 V 40 58 60 20 25 25 83 90 HKSC19C6-240 V 40 58 60 40 50 50 108 110 HKSCISXF-240 V A 0.0 1 7.9 15 34.6 1 43 1 45 1 --- See notes on page 14. SS-GASPT www.goodmanmfg.com 13 HEAT KIT DATA (CONT. .• •. • ASPT61D14AC 0/0 8.6/8.6 15/15 --- 15 - - - HKSX03XC-208 V 10.8 22 25 -- _- -- --- --- HKSX05XC-208 V 17.3 30.3 35 --- - --- --- --- HKSX06XC-208V No Breaker 21.7 36, 40 --- --- --- --- --- H KSX08XC-208 V 28.9 45 45 --- -- -- --- --- HKSX10XC-208 V 34.7 52 60 = -- --- --- HKSC05XC-208 V 17.3 30.3 35 --- --- --- --- --- H KSC08XC-208 V 28.9 45 45 - --- --- --- --- HKSCIOXC-208 V 34.7 52 60 --- --- --- --- --- HKSCI5XB 3-208 V 34.7 52 60 17.3 22 25 74 80 Breaker HKSC20DH-208 V 34.7 52 60 34.7 43 45 95 100 H KSC15XF-208 V A 0 8.6 15 30 38 40 --- --- HKSC20XF-208 V A 0 8.6 15 37.5 47 50 --- --- HKSC25DA-208 V 52 74 80 35 43 45 117 125 HKSX03XC-240 V 12.5 24 25 --- --- --- --- --- H KSX05XC-240 V 20 34 35 --- --- --- --- --- HKSX06XC-240 V No Breaker 25 40 40 --- --- --- --- --- HKW8XC-240 V 33.3 50.3 60 --- - --- --- --- HKSX10XC-240 V 40 S9 60 --- --- --- --- --- HKSC05XC-240 V 20 34 35 --- --- --- --- --- HKSC08XC-240 V 33.3 SO.3 60 --- - --- --- --- HKSCIOXC-240 V 40 59 60 --- --- --- --- --- HKSCI5XB-240 V 40 59 60 20 25 25 84 90 Breaker HKSC20DB-240 V 40 59 60 40 50 50 109 110 HKSC15XF-240 V^ 0 8.6 15 34.6 43 45 --- --- HKSC20XF-240 V A 0 8.6 15 43.3 54 60 --- --- HKSC25DB-240 V 1 60 84 1 90 1 40 1 50 1 50 1 134 1150 Minimum Circuit Ampacity(Heater Amps+Motor Amps)X 1.25 Note:The 208 or 240 in the heat kit part number field is for clarification of the nominal Z voltage for this model. Maximum Overcurrent Protection=2.25 X Motor Amps+Heater Amps ' Notation is correct as XB because technically the 240V heater kit application can be used Circuit 1:Single-phase for Air Handlers Circuit 2:Three-phase for HKR3 Heater Kits here without any issues. --- indicates Not Required HEATING KW CORRECTION FACTOR VOLTAGESUPPLY 240 230 220 210 208 • 1.00 0.92 0.84 0.77 0.7S Multiply the 240-volt heating capacity by correction factors. 14 www.goodmanmfg.com SS-GASPT Lf) Z N FL FL F FL TL TL TL (nFL (D RF I TL TL TL K BK BK PlF TL L TL N (D D K CD RD B 3 (D BK BL RO B -BL p `3 M1 RD BLPU RBL B I`J N Lrl R BN A11 MJ D rL�C M2 O R RI B ° w C Ml Ma O K w R1 R2 WrD BK O e BK BK q O R K D O tt I� O T DK qr H7_ O Loi BN QJ Q _ Q L1 L2 L1 L2 Li L2 LI L2 L1 l2 LI L2 Z ONE(1)ELEMENT ROWS❑ TWO(2)ELEMENT ROWS❑ THREE(3)ELEMENT ROWS❑ FOUR(4)ELEMENT ROWS❑ o NOTE:WHEN INSTALLING HEATER KIT,ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED(MBS)SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE.AFTER INSTALLING OPTIONAL HEAT KIT, MARK A"X"IN THE BOX PROVIDED ABOVE.MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED.NO MARK INDICATES NO HEAT KIT INSTALLED. GRO110J E9UIPMENTGROUND —4 2081240 VOLTS / \ OO SEENOTE 2 -E..---A. 1 WIRING CODE 1 2 Y1 Y2 O DH 1 _ L1 L2 ' S FACTORY WIRING d I PLF PLF 2 \ HIGHVOLTAGE ELD WIRING 3 PLF 2 (2) Q � © TO D BO EM /It LOW VOLTAGE j1PLM N PLM 2 3 1 2 LR 4 FHIGH VOLTAGE 1 3 PLM 2 3Q 4 5 6 70 Q8 9Q � LOW VOLTAGE M /GR eK RD BL W WI NOTE On BB SEE NOTE 1 ALTERNATE HEAT RELAY COLOR CODE 3 WN 1 2 1 BK_BLACK GR_GREEN RD-RED PU_PURPLE TR YL_YELLOW BR_BROWN RD�' WH B A 4 7 SL_BLUE WH_WHITE P,J a lav 5 CR COMPONENT CODE FUSE GR J. R. ROL RELAY T NOTE1 (OPTIONAL) 2 EM EM_EVAPORATOR MOTOR WH 3 FL FUSE LINK pD 4 1 RD C zao 5 HTR_HEAT ELEMENTS o TR PLF—FEMALE PLUG CONNECTOR GR A B ° PLM—MALE PLUG CONNECTOR BL R_RELAY D & FUSE PU TB_TERMINAL BOARD aL 1CWER TR_TRANSFORMER RD.BK RDe�erc IOPTIDN4L DR BR YL NOTES: TL_THERMAL LIMIT 1)RED WIRES TO BE ON TRANSFORMER TERMINAL-3-FOR 240 VOLTS AND ON Y 1 n COPPER POWER SUPPLY TERMINAL'2'FOR 208 VOLTS, (USE RATING PLATE) 'EM' 2)SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR O USE MIN.75°C FIELD WIRE 4 PROPER LOW VOLTAGE WIRING CONNECTIONS. T WH el 3)CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION.IF IF REPLACEMENT OF THE ORIGINAL WIRES RD eK SPEED TAP NEEDS TO BE CHANGED,CONNECT PURPLE WIRE FROM TERMINAL 4 2 5 OF CR RELAY TO APPROPRIATE TAP AT TB SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, 4)BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. USE WIRE THAT CONFORMS TO THE NATIONAL G 1 3 5)FUSE:3A,250V,SAG CARTRIDGE FUSE. ELECTRIC CODE. 0140A00063-B ALTERNATE HEAT RELAY C) a Wiring is subject to change.Always HigG h Voltage:Disconnect all power before servicing or installing this unit. Multiple power � F refer to the wiring diagram on the IS WARNING sources maybe present.Failure to do so may cause property damage,personal injury,or death. Ln unit for the most up-to-date wiring. FIVE-ELEMENT HEATER KIT WIRING DIAGRAM TL HTR1 BK TL FL COMPONENT CODE COLOR CODE HTR2 FL RD PC=9 PIN CONNECTOR BK=BLACK 110 HTR=HEATER ELEMENT BL=BLUE R3 TL=THERMAL LMT BR=BROWN M' RS=RELAY/SEQUENCER GR=GREEN HTR3 YL TB=TERMINAL BLOCK OR=ORANGE TL FL BL CB=CIRCUIT BREAKER PK=PINK CC=CONTACTOR PU=PURPLE BK .TRFL BL PU FL=FUSE LINK RD=RED TL EM=EVAPORATOR MOTOR WH=WHITE EBTDR=ELEC.BLOWER TIME DELAY YL=YELLOW HTRSFL BK O RC=RUN CAPACITOR RD TR=TRANSFORMER BL O SR=STRAIN RELIEF BK RD Pu WH WIRING CODE: BL 3 HIGH VOLTAGE PU YL Irz 1w M5 "I RD LOW M11 BL 4 VOLTAGE M13 ies 11. R1 R2 BR s PU aK NOTE:WHEN INSTALLING HEATER KIT,ENSURE SPEED TAP MUST EXCEED OR RD wH 6 EQUAL THE MINIMUM BLOWER SPEED(MBS) SPECIFIED FOR THE AIRHANDLER I OHEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.AFTER INSTALLING ' OPTIONAL HEAT KIT,MARK AN'W'IN THEE] PROVIDED BELOW. vL NO MARK INDICATES NO HEAT KIT INSTALLED. BL O BK RD O FIVE(5)ELEMENT ROWS ❑ NOTE: CB CB1 62 THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION L1 L2 L1 2 L1 L2 = B RD BK R YI B4 L1 L2 0140M00274-A Wiring is subject to change.Always Hig refer to the wiring diagram on the I h Voltoge: Disconnect all power before servicing or installing this unit. Multiple power unit for the most up-to-date wiring. WARNING sources may be present.Failure to do so may cause property damage,personal injury,or death. 7 16 www.goodmanmfg.com SS-GASPT THREE-PHASE HEATER KIT WIRING DIAGRAM. NOTE:WHEN INSTALLING HEATER KIT,ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER —� CIRCUIT 1 SPEED(MBS)SPECIFIED FOR THE AIRHANDLERMEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. O 1 PH 208-240V AFTER INSTALLING OPTIONAL HEAT KIT,MARK AN"X"IN THE O PROVIDED BELOW. Lf L2 NO MARK INDICATES NO HEAT KIT INSTALLED. BK RD 0 Ll BK R B NTRJ FL TL BN RD RD 3 5 B FL NTRz TL Pu-(D U RD BL BL u u Lf BK BL Oe RK FL MRf TL MBK BK RD B oGR PU PU NM7OpR NO GVD B B :R COM BK BK 8K 8K BK BL 9L BL Fo" O NC BK RB WH BR PEEDUP Mt L' LI n 8N BK WH Mf MJ O GR R u R n BK IK PU PK Mx O BL B B u n BK pU BR WM rt-BR RL EM CIRCUIT 2 GR SST R = 3 PH.208-240V O-B AR POWER SUPPLY HKR POWER SUPPLY Lf (CIRCUIT f) (CIRCUIT2) Z 1 —20BRKDVOLTB— 1 1 ('OMPONFNT CODF Cnl nR ronF Tf FL NTRJ 2 L R2 TL NTR_NEATELEMENT EM—EVAPORATORMOTOR BK BLACK RL E EBTOR-ELEGBLOWERTIME DELAY REIAY BLUE RS_RELAYSEOUENCER ER ORGWN LOWMf NC NO R NfRf TL RC RUN CAPACROR GR GREEN B DR TL_TNERMALLIMR OR ORANGE NOTE: coM rR_TRANSFORMER —K THIS LABEL MUST BE ' R re_ERMCLY BLOO Pu PURPLE _CONTACTOR RD REO ATTACHED ON THE J PC_4 CONNECTOR SR_STRAIN REN EF WN'wRfTE AIRHANDLER IN A PROMINENT _PGSE W n Euow LOCATION 24 VOLT B NJ MJ cO�LIRLUR BREAKER YI 'OM1 EBTDR RS WIRING fDDF PK R BR —VOLTAGE v v vv HEATER CONTROL DIABMD02T&A Wiring is subject to change.Althe ways refer to the wiring diagram on � High 1'e: Disconnect all power before servicing or installing this unit. Multiple power unit for the most g d! date wiring. WARNING sources may be present.Failure to do so may cause property damage,personal injury,or death. SS-GASPT www.goodmanmfg.com 17 ACCESSORIES DOWNFLOW INSULATION KIT . DF ASPT24B14** ASPT42C14** ASPT42D14** ASPT35614** ASPT48C14** ASPT48D14** ASPT60D14** ASPT61D14** FILTERS PART# SIZE ALFH16201E 16.0"x 20.0" C ALFH1912201E 19.5"x 20.0" D B 7ALFH20231E 23.0"x 20.0" 18 www.goodmanmfg.com SS-GASPT Englert Residence Model GSX160361 F GSX16 Air Conditioning&Heating COOLING CAPACITY.•18,000-57,000 ENERGY-EFF/CI ENT SPLIT SYSTEM AIR CONDITIONER 1'z To 5 ToNs UP To 16 SEER Contents Nomenclature........................................2 Product Specifications...........................3 Expanded Cooling Data.........................5 • Dimensions..........................................29 Wiring Diagrams .................................30 Accessories.........................:................34 Standard Features Cabinet Features • Energy-efficient compressor • Heavy-gauge galvanized-steel cabinet • Factory-installed filter drier with a louvered sound control top • Fully charged for 15'of tubing length • Attractive Architectural Gray powder-paint • Copper tube/aluminum fin coil finish with 500-hour salt-spray approval • Service valves with sweat connections • Wire fan discharge grille and easy-to-access gauge ports • Steel louver coil guard • Contactor with lug connection • Single-panel access to controls with space • Ground lug connection provided for field-installed accessories • AHRI Certified • When properly anchored,meets the 2017 Florida Building • ETL Listed Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) 1 O PARTS I UNIT �� COMPANYVRfN COMPANY-SY REPLACEMENT \\�\�\..�^��ww�r�'// GU1FMORYDNV ENERWEENTAL SYSTEM Proper sizing and installation of equipment is LIMITED c us cERrmEoavoNvaL cERrffieoerorrvoL ` ® LIMITED .Lsoeoot• •isotmw= 1 critical to achieving optimal performance.Split YEAR WARRANTY' YEAR WARRANTY' �r � system air conditioners and heat pumps must Intertek be matched with appropriate coil components to 'Complete warranty details available your local dealer ora[www.goodmanmfg.com.To receive the 2-Year Unit Replacement BBB. meet ENERGY STAR"criteria.Ask your contractor Limited Warranty and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation. 059 for details or visit www.energystacgov. Online registration is not required in California or Quebec. SS-GSX16 www.goodmanmfg.com 2/20 Supersedes 12/19 NOMENCLATURE G S X 16 0 36 1 AA 1 2 3 4,5 6 7,8 9 10,11 Brand Engineering G Goodman'Brand Major&Minor Revisions (not used for inventory or ordering) Product Category Electrical S Split System 1 208/230 V,1 Phase,60 Hz 2 220/240 V,1 Phase,50 Hz Unit Type 3 208/230 V,3 Phase,60 Hz X Condenser R-410A Z Heat Pump R-410A Nominal Capacity 18 1%Tons 30 2%Tons 42 3'/:Tons Efficiency 19 1%Tons 31 2%Tons 43 T/2 Tons 13 13 SEER 16 16 SEER 24 2 Tons 36 3 Tons 48 4 Tons 14 14 SEER 18 18 SEER 25 2 Tons 37 3 Tons 60 5 Tons Legacy National Model 0 Legacy National Model S Sold In Southeast and North Regions A Sold In All Regions 2 www.goodmanmfg.com SS-GSX16 PRODUCT SPECIFICATIONS 0181F* 0241F* 0301F* 0311A* 0361F* 0371A* �• �•: �.� CAPACITIES Nominal Cooling(BTU/h) 18,000 23,600 29,000 30,000 34,800 36,000 42,000 45,500 54,000 SEER 16 16 16 16 16 16 16 16 16 Decibels 71.5 71.5 71.5 73.5 71.5 73 73 73 73 COMPRESSOR RLA 9.0 13.5 12.8 12.8 14.1 15.4 17.9 17.9 21.4 LRA 46 58.3 64 64 77 83.9 112 112 135 CONDENSER FAN MOTOR Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 1/6 1/4 1/3 FLA 0.95 0.95 0.95 0.95 0.95 0.95 0.95 1.30 2.80 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size("O.D.) W. %" W. W. W. W. W. W. W. Suction Line Size("O.D.) W. Y" Refrigerant Connection Size Liquid Valve Size("O.D.) W. W. W, W, W, W, W. W, Suction Valve Size("O.D.) W '/" %' %" %" %" %e' Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 78 70 78 94 94 93 110 121 237 ELECTRICAL DATA Voltage-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230- 208/230-1 08/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity 1 12.2 17.8 17.0 17.0 18.6 20.2 23.3 23.7 29.6 Max.Overcurrent Protection a 20 30 25 25 30 35 40 40 50 Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size /:"or%" /:"or'/ %"or Y," %"or%" %"or%" %:"or%" %:"or%" %"or%" %"or X" EQUIPMENT WEIGHT(LBS) 145 142 149 155 162 182 206 219 279 SHIP WEIGHT(LBS) 163 160 167 179 180 204 228 241 301 ENERGY STARS CERTIFIED I= rZT1717 M_ ENERGY STAR NOTES • Proper sizing and installation of equipment is critical to achieving optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR''criteria.Ask your contractor for details or visit www.energystar.gov. • The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR'requirements: Tested and rated in accordance with AHRI Standard 210/240 ' Wire size should be determined in accordance with National Electrical Codes;extensive wire runs will require larger wire sizes 3 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply%"to 1%"adapters for suction line connections. • Unit is charged with refrigerant for 15'of%"liquid line.System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-GSX16 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS(CONT.) 181A* 241A* 301A* 361A* 421A* 481A CAPACITIES Nominal Cooling(BTU/h) 18,000 23,600 29,000 34,800 42,000 45,500 SEER 16 16 16 16 16 16 Decibels 71 71 73.S 73.S 73 73 COMPRESSOR RLA 6.0 7.7 12.8 14.1 17.9 17.9 LRA 37.5 38 64 77 112 112 CONDENSER FAN MOTOR Horsepower 1/6 1/6 1/6 1/6 1/6 1/4 FLA 0.95 0.95 0.95 0.95 0.95 1.30 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size("O.D.) W. W. W, 'W, W, 3W, Suction Line Size("O.D.) '/<" W. Refrigerant Connection Size Liquid Valve Size("O.D.) W W, %' %" W. %' Suction Valve Size("O.D.) '/<" '/<" %" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 84 70 78 94 110 121 ELECTRICAL DATA Voltage-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity z 8.5 10.6 17.0 18.6 23.3 23.7 Max.Overcurrent Protections 15 15 25 30 40 40 Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size /:"or%" Y."or%" %"or M" W'or Y4" Y2"or'W %"or%" EQUIPMENT WEIGHT(LBS) 135 132 149 162 206 219 SHIP WEIGHT(LBS) 154 150 167 180 228 241 ENERGY STAR®CERTIFIED © Q NO NO NO NO ENERGY STAR NOTES • Proper sizing and installation of equipment is critical to achieving optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR'criteria.Ask your contractor for details or visit www.energystar.gov. • The www.energystargov website provides up-to-date system combinations certified to meet ENERGY STAR' requirements. ' Tested and rated in accordance with AHRI Standard 210/240 Wire size should be determined in accordance with National Electrical Codes;extensive wire runs will require larger wire sizes 3 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply%"to 1%"adapters for suction line connections. • Unit is charged with refrigerant for 15'of%"liquid line.System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. 4 www.goodmanmfg.com SS-GSX16 Lr, OUTDOOR AMBIENT TEMPERATURE C) 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 - S/T 0.68 0.57 0.40 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.43 0.78 0.65 0.45 0.78 0.66 0.45 AT 19 16 12 19 17 13 19 17 13 19 17 13 19 16 13 18 15 12 525 kW 1.18 1.20 1.23 1.26 1.28 1.31 1.32 1.35 1.38 1.38 1.41 1.45 1.43 1.46 1.50 1.47 1.50 1.54 Amps 4.3 4.3 4.5 4.6 4.7 4.8 4.9 5.0 5.2 5.2 5.4 5.5 5.6 5.7 5.9 5.9 6.0 6.2 HiPR 199 214 226 223 240 254 254 273 289 289 311 329 326 350 370 360 387 409 Lo PR 101 108 118 107 114 125 111 119 129 117 125 136 123 130 142 127. 135 147 MBh 17.1 17.7 19.4 16.7 17.3 19.0 16.3 16.9 18.5 15.9 16.5 18.1 15.1 15.7 17.2 14.0 14.S 15.9 S/T 0.71 0.59 0.41 0.73 0.61 0.43 0.75 0.63 0.44 0.78 0.65 0.45 0.81 0.67 0.47 0.81 0.68 0.47 AT 17 15 11 17 15 11 17 15 11 18 15 12 17 15 11 16 14 11 70 650 kW 1.21 1.23 1.26 1.28 1.31 1.34 1.35 1.38 1.41 1.41 1.44 1.48 1.46 1.49 1.53 1.51 1.54 1.58 Amps 4.4 4.5 4.6 4.7 4.8 4.9 5.1 5.2 5.3 5.4 5.5 5.7 5.7 5.8 6.0 6.0 6.2 6.4 HiPR 205 221 233 230 248 262 262 282 298 298 321 339 336 361 381 371 399 421 Lo PR 105 111 122 111 118 128 115 122 133 121 128 140 126 135 147 131 139 152 MBh 17.1 17.7 19.4 16.7 17.3 19.0 16.3 16.9 18.5 15.9 16.5 18.1 15.1 15.7 17.2 14.0 14.5 15.9 k S/T 0.71 0.59 0.41 0.73 0.61 0.43 0.75 0.63 0.44 0.78 0.65 0.45 0.81 0.67 0.47 0.81 0.68 0.47 n AT 17 14 11 17 14 11 17 15 11 17 15 11 17 14 11 16 13 10 Z 675 kW 1.21 1.23 1.26 1.28 1.31 1.34 1.35 1.38 1.41 1.41 1.44 1.48 1.46 1.49 1.53 1.51 1.54 1.58 o Amps 4.4 4.5 4.6 4.7 4.8 4.9 5.1 5.2 5.3 5.4 5.5 5.7 5.7 5.8 6.0 6.0 6.2 6.4 O Hi PR 205 221 233 - 230 248 262 - 262 282 298 - 298 321 339 - 336 361 381 - 371 399 421 - 0 0- 3 v Lo PR 105 111 122 111 118 128 115 122 133 121 128 140 126 135 147 131 139 152 p Z 3 Z 0o MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7 G1 o S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39 AT 22 20 16 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 21 19 16 11 )5.- 525 525 kW 1.19 1.21 1.24 1.28 1.27 1.29 1.32 1.36 1.33 1.36 1.39 1.43 1.39 1.42 1.46 1.50 1.44 1.47 1.51 1.55 1.48 1.51 1.56 1.60 Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.1 6.3 6.5 Hi PR 201 216 229 238 226 243 257 268 257 276 292 304 292 315 332 347 329 354 374 390 363 391 413 431 C) Ln Lo PR 103 109 119 127 108 115 126 134 113 120 131 139 118 126 137 146 124 132 144 153 128 136 149 159 >C 1-4 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 O1 S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 �O AT 20 18 15 10 20 19 15 10 20 19 15 10 20 19 15 11 20 18 15 10 19 17 14 10 75 650 kW 1.21 1.24 1.27 1.30 1.29 1.32 1.35 1.39 1.36 1.39 1.42 1.46 1.42 1.45 1.49 1.53 1.47 1.50 1.54 1.59 1.52 1.55 1.59 1.64 6" Amps 4,4 4.5 4.6 4.8 4.7 4.800 5.0 5.2 5.1 5.2 5.4 5.6 5.4 5.6 5.7 5.9 5.8 5.9 6.1 6.3 6.1 6.2 6.4 6.7 Hi PR 207 223 236 246 233 250 264 276 265 285 301 314 301 324 343 357 339 365 385 402 375 403 426 444 Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0,77 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 4T 19 18 14 10 19 18 15 10 19 18 15 10 20 18 15 10 19 18 15 W 10 18 17 14 9 0) 675 kW 1.21 1.24 1.27 1.30 1.29 1.32 1.35 1.39 1.36 1.39 1.42 1.46 1.42 1.45 1.49 1.53 1.47 1.50 1.54 1.59 1.52 1.55 1.59 1.64 W Amps 4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.4 5.6 5.7 5.9 5.8 5.9 6.1 6.3 6.1 6.2 6.4 6.7 (3) Hi PR 207 223 236 246 233 250 264 276 265 285 301 314 301 324 343357 339 365 385 402 375 403 426 444 Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163 + IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) Ln High and low pressures are measured at the liquid and suction service valves. kW=Total system power OUTDOOR AMBIENT TEMPERATURE x 652F 752F 852F 959F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE O IDB AIRFLOW 59 63 67 71 59 63 1 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 m MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6 S/T 0.85 0.80 0.65 0.49 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.55 0.98 0.92 0.75 0.56 p AT 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 25 24 20 16 23 22 19 15 525 kW 1.20 1.22 1.25 1.28 1.27 1.30 1.33 1.37 1.34 1.37 1.40 1.44 1.40 1.43 1.47 1.51 1.45 1.48 1.52 1.57 1.49 1.52 1.57 1.61 Z Amps 4.3 4.4 4.6 4.7 4.6 4.7 4.9 5.1 5.0 5.1 5.3 5.S 5.3 5.5 5.6 5.8 5.7 5.8 6.0 6.2 6.0 6.1 6.3 6.5 G) Hi PR 203 219 231 241 228 245 259 270 259 279 295 307 295 318 336 350 332 358 378 394 367 395 417 435 Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160 n MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9 S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 10.55 1.00 0.94 0.77 0.57 1.00 0.95 0.77 0.58 AT 22 21 18 15 22 21 19 15 22 22 19 15 23 22 19 1S 22 21 19 15 21 20 17 14 k 80 650 kW 1.22 1.24 1.28 1.31 1.30 1.32 1.36 1.40 1.37 1.40 1.43 1.48 1.43 1.46 1.50'; 1.54 1.48 1.51 1.56 1.60 1.53 1,56 1.60 1.65 H Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.4 6.1 6.3 6.5 6.7 (3) Hi PR 209 225 238 248 235 253 267 279 267 288 304 317 304 328 346 ! 361 343 369 389 406 378 407 430 449 Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165 MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9 00 00 S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.95 0.77 0.58 AT 21 20 18 14 22 21 18 14 22 21 18 14 22 21 18 14 21 21 18 14 20 19 17 13 675 kW 1.22 1.24 1.28 1.31 1.30 1.32 1.36 1.40 1.37 1.40 1.43 1.48 1.43 1.46 1.50 1.54 1.48 1.51 1.56 1.60 1.53 1.56 1.60 1.65 o Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.4 6.1 6.3 6.5 6.7 n 00- Hi PR 209 225 238 248 235 253 267 279 267 288 304 317 304 328 346 361 343 369 389 406 378 407 430 449 W 3i Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165 lou 66, MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5 Ql o S/T 0.89 0.86 0.78 0.63 0.93 0.89 0.81 0.65 0.95 0.92 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89_ 0.72 1.00 0.99 0.89 0.72 3 AT 26 26 24 21 26 26 25 21 26 26 25 21 27 26 25 21 26 26 24 21 24 24 23 20 + 525 kW 1.21 1.23 1.26 1.29 1.28 1.31 1.34 1.38 1.35 1.38 1.41 1.45 1.41 1.44 1.48 1.52 1.46 1.49 1.53 1.58 1.51 1.53 1.58 1.63 k Amps 4.4 4.5 4.6 4.7 4.7 4.8 4.9 5.1 5.1 5.2 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 C Hi PR 205 221 233 243 230 248 262 273 262 282 298 310 298 321 339 3S4 336 361 381 398 371 399 421 439 n Lo PR 105 111 121129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 1S6 131 139 152 162 Z Z MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8 ti S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 AT 24 23 22 19 24 24 22 19 24 24 22 19 24 24 22 19 23 23 22 19 21 21 21 18 85 650 kW 1.23 1.25 1.29 1.32 1.31 1.33 1.37 1.41 1.38 1.41 1.44 1.49 1.44 1.47 1.51 1.55 1.49 1.52 1.57 1.61 1.54 1.57 1.62 1.66 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.7 5.8 6.0 5.9 6.0 6.2 6.4 6.2 6.3 6.5 6.8 Hi PR 212 228 240 251 237 255 270 281 270 291 307 320 308 331 349 364 346 372 393 410 382 411 434 453 Lo PR 1 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8 S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 AT 23 22 21 18 23 23 21 19 23 23 21 19 23 23 22 19 22 22 21 18 20 20 20 17 675 kW 1.23 1.25 1.29 1.32 1.31 1.33 1.37 1.41 1.38 1.41 1.44 1.49 1.44 1.47 1.51 1.55 1.49 1.52 1.57 1.61 1.54 1.57 1.62 1.66 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.7 5.8 6.0 5.9 6.0 6.2 6.4 6.2 6.3 6.5 6.8 Hi PR 212 228 240 251 237 255 270 281 270 291 307 320 308 331 349 364 346 372 393 410 382 411 434 453 Y Lo PR 108 11S 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 G) U' IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) x High and low pressures are measured at the liquid and suction service valves. kW=Total system power Ln OUTDOOR AMBIENT TEMPERATURE G) 65°F 75°F 852F 952F 1052F 1152F NI ENTERING INDOOR WET BULB TEMPERATURE lIDE1 AIRIFLOW 1 59 63 67 71 59 63 67 71 59 63 1 67 71 1 59 63 1 67 71 59 63 67 71 59 63 67 71 MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7_ S/T 0.69 0.57 0.40 0.71 0.59 0.41 0.73 0.61 0.42 0.75 0.63 0.44 0.78 0.155 0.45 0.79 0.66 0.46 AT 19.0 16.4 12.5 19.2 16.6 12.6 19.2 16.7 12.6 19.4 16.8 12.7 19.1 16.5 12.6 17.9 15.5 11.7 0 kW 0.93 0.95 0.98 1.00 1.02 1.05 1.06 1.09 1.12 1.12 1.14 1.18 1.17 1.19 1.23 1.21 1.23 1.28 Amps 4.2 4.3 4.4 4.5 4.6 4.7 4.9 5.0 5.1 5'.2 5.3 5.5 5.5 5.6 5.8 5.8 5.9 6.1 Hi PR 195 210 222 219 236 249 249 268 283 284 306 323 320 344 363 353 380 401 Lo PR 105 112 122 111 118 129 116 123 134 122 129 141 127 136 148 132 140 153 M Bh 16.6 17.2 18.9 16.2 16.8 18.4 15.8 16.4 18.0 15.5 16.0 17.5 14.7 15.2 16.7 13.6 14.1 15.4 S/T 0.70 0.58 0.40 0.72 0.60 0.42 0.74 0.62 0.43 0.76 0.64 0.44 0.79 0.66 0.46 0.80 0.67 0.46 AT 17.7 15.4 11.7 18.0 15.5 11.8 18.0 15.6 11.8 18.1 15.7 11.9 17.9 15.5 11.7 16.7 14.4 11.0 70 0 kW 0.94 0.96 0.99 1.01 1.03 1.07 1.07 1.10 1.13 1.13 1.16 1.19 1.18 1.21 1.25 1.22 1.25 1.29 Amps 4.2 4.3 4.5 4.6 4.7 4.8 4.9 5.0 5.2 5.2 5.4 5.5 5.5 5.7 5.9 5.9 6.0 6.2 Hi PR 198 213 225 222 239 253 253 272 287 288 310 327 324 349 368 358 385 407 Lo PR 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 134 142 155 MBh 17.1 17.7 19.4 16.7 17.3 19.0 16.3 16.9 18.5 15.9 16.5 18.1 15.1 15.7 17.2 14.0 14.5 15.9 S/T 0.71 0.59 0.41 0.74 0.62 0.43 0.76 D.63 0.44 0.78 0.65 0.45 0.81 0.68 0.47 0.82 0.68 0.47 :E AT 17.2 14.9 11.3 17.5 15.1 11.5 17.5 15.1 11.5 17.6 15.2 11.6 17.3 15.0 11.4 16.2 14.0 10.6 k 0 kW 0.95 0.97 1.00 1.02 1.05 1.08 1.09 1.11 1.15 1.15 1.17 1.21 1.20 1.22 1.26 1.24 1.27 1.31 a do Amps 4.3 4.4 4.5 4.6 4.7 4.9 5.0 5.1 5.3 5.3 5.4 5.6 5.6 5.8 5.9 5.9 6.1 6.3 CL Hi PR 202 217 229 226 243 257 257 277 292 293 315 333 330 355 374 364 392 414 m 3 Lo PR 109 116 126 115 122 133 119 127 139 125 133 146 131 140 153 136 144 158 3 O 3 MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7 O r o S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.90 0.80 0.61 0.39 Z 3 AT 22.0 20.2 16.6 11.4 22.2 20.5 16.8 11.6 22.2 20.5 16.8' 11.6 22.4 20.6 16.9 11.7 22.1 20.3 16.7 11.5 20.6 19.0 15.6 10.7 G) 0 kW 0.93 0.95 0.98 1.02 1.01 1.03 1.06 1.10 1.07 1.09 1.13 1.17 1.13 1.15 1.19 1.23 1.18 1.20 1.24 1.29 1.22 1.25 1.29 1.33 0 Amps 4.2 4.3 4.5 4.6 4.5 4.6 4.8 5.0 4.9 5.0 5.2 5.4 5.2 5.3 5.5 5.7 5.5 5.7 5.8 6.0 5.8 6.0 6.2 6.4 n Hi PR 197 213 224 234 222 238 252 263 252 271 286 299 287 309 326 340 323 347 367 383 357 384 405 423 Lo PR 1 106 113 124 132 112 120 131 139 117 124 136 145 123 131 143 152 129 137 149 159 133 142 155 165 MBh 16.9 17.4 18.8 20.2 16.5 17.0 18.4 19.7 16.1 16.618.0 19.3 15.7 16.2 17.5 18.8 14.9 15.4 16.6 17.9 13.8 14.2 15.4 16.5 S/T 0.79 0.71 0.54 0.35 0.82 0.73 0.56 0.36 0.84 0.75 0.57. 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40 AT 20.5 18.9 15.5 10.7 20.8 19.1 15.7 10.8 20.8 19.1 15.7 10.8 20.9 19.3 15.8 10.9 20.6 19.0 15.6 10.7 19.3 17.7 14.5 10.0 0) 75 0 kW 0.94 0.96 1.00 1.03 1.02 1.04 1.07 1.11 1.08 1.11 1.14 1.18 1.14 1.17 1.21 1.25 1.19 1.22 1.26 1.30 1.23 1.26 1.30 1.35 Amps 4.3 4.4 4.5 4.7 4.600 4.7 4.8 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 Hi PR 200 215 227 237 225 242 255 266 255 275 290 303 291 313 331 345 327 352 372 388 362 389 411 429 Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 143 157 167 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 AT 19.9 18.4 15.0 10.4 20.2 18.6 15.2 10.5 20.2 18.6 15.2 10.5 20.3 18.7 15.3 10.6 20.0 18.5 15.1 10.4 18.7 17.2 14.1 9.8 W 0 kW 0.96 0.98 1.01 1.04 1.03 1.06 1.09 1.13 1.10 1.12 1.16 1.20 1.16 1.18 1.22 1.26 1.21 1.23 1.28 1.32 1.25 1.28 1.32 1.37 Owl Amps 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.0 5.2 5.3 5.5 5.4 S.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.1 6.3 6.6 Hi PR 204 219 231 241 228 246 260 271 260 280 295 308 296 318 336 351 333 358 378 395 368 396 418 436 Ql Lo PR 110 117 127 136 116 123 135 143 121 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170 IDB:Entering Indoor Dry Bulb Temperature(9F) Shaded area reflects ACCA(TVA)conditions HI PR=PRESSURE AT LIQUID SERVICE VALVE,PSIG Amps=outdoor unit amps(comp.+fan) �I v High and low pressures are measured at the liquid and suction service valves. MBH=NET TOTAL CAPACITY(s000 Biu/HR) LO PR=PRESSURE AT VAPOR SERVICE VALVE,PSIG kW=Total system power S/T=SENSIBLE TO TOTAL CAPACITY RATIO 00 OUTDOOR AMBIENT TEMPERATURE X 652F 752F 85°FI 952F 10521' 1152F ENTERING INDOOR WET BULB TEMPERATURE O ID113 AIRFLOW 59 63 67 71 59 63 67 71 59 63 1 67 71 59 63 67 71 59 63 67 71 59 63 67 73L m MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6 tz) S/T 0.86 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 0.98 0.92 0.75 0.56 0 AT 24.5 23.5 20.4 16.3 24.8 23.8 20.7 16.5 24.8 23.8 20.7 16.5 25.0 24.0 20.8 16.7 24.7 23.6 20.6 16.4 23.0 22.1 19.2 15.3 r 0 kW 0.94 0.96 0.99 1.03 1.02 1.04 1.07 1.11 1.08 1.10 1.14 1.18 1.14 1.16 1.20 1.24 1.19 1.21 1.25 1.30 1.23 1.26 1.30 1.34 Z Amps 4.3 4.4 4.5 4.6 4.6 4.7 4.8 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.7 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.4 Hi PR 199 215 227 236 224 241 254 265 255 274 289 302 290 312 329 344 326 351 371 387 360 388 410 427 Lo PR 108 114 125 133 114 121 132 141 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 17.2 17.6 18.8 20.1 16.8 17.2 18.3 19.6 16.4 16.8 17.9 19.1 16.0 16.3 17.5 18.7 15.2 15.5 16.6 17.7 14.1 14.4 15.4 16.4 S/T 0.87 0.81 0.66 0.50 0.90 0.84 0.69 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.73 O.S4 0.99 0.93 0.76 0.56 1.00 0.94 0.76 0.57 AT 22.9 21.9 19.1 15.2 23.2 22.2 19.3 1S.4 23.2 22.2 19.3 15.4 23.4 22.4 19.5 15.6 23.0 22.1 19.2 15.3 21.5 20.6 17.9 14.3 k 80 0 kW 0.95 0.97 1.00 1.04 1.03 1.05 1.08 1.12 1.09 1.12 1.15 1.19 1.15 1.18 1.22 1.26 1.20 1.23 1.27 1.31 1.24 1.27 1.31 1.36 N Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.1 5.0 5.1 5.3 5.5 5.3 5.4 5.6 5.8 5.6 5.8 6.0 6.2 6.0 6.1 6.3 6.5 0) Hi PR 202 218 230 240 227 244 258 269 258 278 293 306 294 316 334 348 331 356 376 392 365 393 415 433 ti 00 Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169 MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9 S/T 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.95 0.77 0.58 1.00 0.96 0.78 0.58 AT 22.2 21.3 18.5 14.8 22.5 21.6 18.8 15.0 22.5 21.6 18.8 15.0 23.3 21.8 18.9 15.1 22.2 21.4 18.7 14.9 20.5 20.0 17.4 13.9 0 kW 0.96 0.99 1.02 1.05 1.04 1.06 1.10 1.14 1.11 1.13 1.17 1.21 1.17 1.19 1.23 1.28 1.22 1.25 1.29 1.33 1.26 1.29 1.33 1.38 ao Amps 4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.1 5.1 5.2 5.4 5.5 S.4 5.5 5.7 5.9 5.7 5.9 6.0 6.3 6.0 6.2 6.4 6.6 Ql o lu a Hi PR 206 221 234 244 231 248 262 273 262 282 298 311 299 322 340 354 336 362 382 399 372 400 422 440 01 Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171 3 � MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5 3 5/T 0.90 0.87 0.78 0.63 0.93 0.90 0.81 0.66 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 0.99 0.90 0.73 k AT 26.1 25.7 24.3 21.0 26.5 26.0 24.6 21.3 26.5 26.1 24.6 21.3 26.7 26.2 24.8 21.5 25.8 25.9 24.5 21.2 23.9 24.2 22.8 19.8 0 kW 0.95 0.97 1.00 1.03 1.02 1.05 1.08 1.12 1.09 1.11 1.15 1.19 1.15 1.17 1.21 1.25 1.20 1.22 1.26 1.31 1.24 1.27 1.31 1.36 n Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.0 5.0 S.1 5.3 5.4 5.3 5.4 5.6 5.8 5.6 5.8 5.9 6.1 5.9 6.1 6.3 6.5 0 Hi PR 201 217 229 239 226 243 257 268 257 277 292 305 293 315 333 347 329 355 374 390 364 392 414 431 7711 Lo PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168 MBh 17.5 17.8 18.7 19.9 17.1 17.4 18.2 19.5 16.7 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.5 15.8 16.5 17.6 14.3 14.6 15.3 16.3 S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74 AT 24.4 24.0 22.7 19.6 24.7 24.3 23.0 19.9 24.7 24.3 23.0 19.9 24.9 24.5 23.2 20.1 23.7 24.1 22.8 19.8 21.9 22.4 21.3 18.5 85 0 kW 0.96 0.98 1.01 1.04 1.03 1.06 1.09 1.13 1.10 1.13 1.16 1.20 1.16 1.19 1.23 1.27 1.21 1.24 1.28 1.32 1.25 1.28 1.33 1.37 Amps 4.4 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.0 5.2 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.1 6.3 6.6 Hi PR 204 220 232 242 229 247 260 272 261 280 296 309 297 319 337 352 334 359 379 396 369 397 419 437 Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170 MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17AHI47PREsSPAT IQUAERVN%ALVE,1AIP 18.2 .14.8 15.0 15.8 16.8 S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 MWONET4c5L CAPAUY(160 /4RpO C)-9U PP-8PRESSQ47RAT VAICOPiERA-99ALVEOPPIZ 0.75 1.00 1.00 0.93 0.75 AT 23.7 23.3 22.1 19.1 24.0 23.6 22.3 19.3 /24.0ENsiR310 To2A1AAPAd&.BA o23.7 23.8 22.5 19.5 22.5 23.0 22.2 19.2 20.9 21.3 20.7 17.9 0 kW 0.97 0.99 1.03 1.06 1.05 1.07 1.11 1.14 1.12 1.14 1.18 1.22 1.18 1.20 1.24 1.29 1.23 1.26 1.30 1.34 1.27 1.30 1.34 1.39 Amps 4.4 4.S 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.5 5.6 5.7 6.0 5.8 5.9 6.1 6.3 6.1 6.2 6.4 6.7 Hi PR 208 224 236 246 233 251 265 276 265 285 301 314 302 325 343 358 340 365 386 403 375 404 426 445 Ln Ln Lo PR 112 119 130 138 118 126 137 146 123 131 143 152 129 137 150 160 135 144 157 167 140 149 163 173 6 L^ IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) X High and low pressures are measured at the liquid and suction service valves. kW=Total system power Ln LnOUTDOOR AMBIENT TEMPERATURE N 652F 759F 859F 952F 1059F 1159F N ENTERING INDOOR WET BULB TEMPERATURE rn •: AIRFLOW 59 63 67 71 59 63 67 71 59 63 67 71 1 59 1 63 1 67 71 59 63 67 71 59 63 67 71 MBh 22.1 22.9 25.1 - 21.6 22.4 24.5 - 21.1 21.9 23.9 - 20.6 21.3 23.4 - 19.5 20.3 22.2 - 18.1 18.8 20.6 - S/T '0.69 0.58 0.40 0.72 0.60 0.42 0.74 0.61 0.43 0.76 0.63 0.44 0.79 0.66 0.46 0.80 0.66 0.46 AT 20 17 13 20 18 13 20 18 13 21 18 13 20 18 13 19 16 12 700 kW 1.54 1.57 1.61 1.64 1.67 1.72 1.74 1.77 1.82 1.82 1.86 1.91 1.89 1.93 1.99 1.95 1.99 2.05 Amps 5.7 5.8 6.0 6.1 6.3 6.5 6.6 6.8 7.0 7.1 7.3 7.5 7.5 7.7 8.0 8.0 8.2 8.4 HiPR 205 221 233 230 248 262 262 282 298 298 321 339 336 361 381 371 399 421 Lo PR 103 109 119 109 116 126 113 120 131 119 126 138 124 132 144 129 137 149 MBh 22.5 23.3 25.5 21.9 22.7 24.9 21.4 22.2 24.3 20.9 21.6 23.7 19.8 20.6 22.5 18.4 19.1 20.9 S/T 0.72 0.60 0.42 0.74 0.62 0.43 0.76 0.64 0.44 0.79 0.66 0.46 0.82 0.68 0.47 0.82 0.69 0.48 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 19 16 12 70 750 kW 1.56 1.59 1.63 1.66 1.70 1.75 1.76 1.79 1.85 1.84 1.88 1.94 1.91 1.95 2.01 1.98 2.02 2.08 Amps 5.8 5.9 6.1 6.2 6.4 6.6 6.7 6.9 7.1 7.2 7.4 7.6 7.6 7.8 8.1 8.1 8.3 8.6 HiPR 209 225 237 234 252 266 267 287 303 304 327 345 342 368 388 377 406 429 Lo PR 105 111 122 111 118 128 115 122 133 121 128 140 126 135 147 131 139 152 MBh 23.2 24.1 26.4 22.7 23.5 25.8 22.2 23.0 25.2 21.6 22.4 24.5 20.5 21.3 23.3 19.0 19.7 21.6 k S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.73 0.50 0.88 0.73 0.51 n AT 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 17 15 11 Z 900 kW 1.58 1.61 1.65 1.69 1.72 1.77 1.78 1.82 1.87 1.87 1.91 1.97 1.94 1.98 2.04 2.01 2.05 2.11 0 m o Amps 5.9 6.0 6.2 6.3 6.5 6.7 6.9 7.0 7.3 7.3 7.5 7.7 7.8 8.0 8.2 8.2 8.4 8.7 O Q HiPR 213 229 242 239 257 272 272 293 309 310 333 352 348 375 396 385 414 437 3 Lo PR 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 133 142 155 p 3 Z 69, MBh 22.5 23.2 25.1 26.9 22.0 22.6 24.5 26.3 21.4 22.1 23.9 25.6 20.9 21.5 23.3 25.0 19.9 20.5 22.1 23.8 18.4 19.0 20.5 22.0 Gl o S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39 3 AT 23 21 18 12 24 22 18 12 24 22 18 12 24 22 18 12 23 22 18 12 22 20 16 11 n 700 kW 1.55 1.58 1.62 1.67 1.66 1.69 1.74 1.79 1.75 1.78 1.84 1.89 1.83 1.87 1.93 1.99 1.90 1.94 2.00 2.06 1.96 2.00 2.07 2.13 Amps 5.7 5.9 6.1 6.3 6.2 6.3 6.5 6.8 6.7 6.9 7.1 7.3 7.2 7.3 7.6 7.8 7.6 7.8 8.0 8.3 8.0 8.2 8.5 8.8 HiPR 207 223 236 246 233 250 264 276 265 285 301 314 301 324 343 357 339 365 385 402 375 403 426 444Ln n' Lo PR 104 111 121 128 110 117 127 136 114 121 132 141 120 127 139 148 126 134 146 155 130 138 151 .161 >C MBh 22.8 23.5 25.4 27.3 22.3 . 23.0 24.9 26.7 21.8 22.4 24.3 26.0 21.2 21.9 23.7 25.4 20.2 20.8 22.5 24.1 18.7 19.2 20.8 22.4 S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41 O AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 18 12 23 21 17 12 21 20 16 11 75 750 kW 1.57 1.60 1.64 1.69 1.68 1.71 1.76 1.81 1.77 1.81 1.86 1.92 1.86 1.89 1.95 2.01 1.93 1.97 2.03 2.09 1.99 2.03 2.09 2.16 N Amps 5.8 6.0 6.1 6.4 6.3 6.4 6.6 6.9 6.8 7.0 7.2 7.5 7.3 7.4 7.7 8.0 7.7 7.9 8.2 8.5 8.2 8.4 8.6 9.0 64 HiPR 211 227 240 250 237 255 269 281 269 290 306 319 307 330 348 363 345 371 392 409 381 410 433 452 Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163 n MBh 23.6 24.3 26.3 28.3 23.1 23.8 25.7 27.6 22.5 23.2 25.1 27.0 22.0 22.6 24.5 26.3 20.9 21.5 23.3 25.0 19.3 19.9 21.6 23.1 1:; S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.83 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43 W AT 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10 01 900 kW 1.59 1.62 1.67 1.72 1.70 1.73 1.79 1.84 1.80 1.83 1.89 1.95 1.88 1.92 1.98 2.04 1.96 2.00 2.06 2.12 2.02 2.06 2.13 2.19 Uj Amps 5.9 6.1 6.3 6.5 6.4 6.5 6.7 7.0 6.9 7.1 7.3 7.6 7.4 7.6 7.8 8.1 7.9 8.0 8.3 8.6 8.3 8.5 8.8 9.1 HiPR 215 232 245 255 241 260 274286 275 296 312 326 313 337 355 371 352 379 400 417 389 418 442 461 Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 + IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) x High and low pressures are measured at the liquid and suction service valves. kW=Total system power O OUTDOOR AMBIENT TEMPERATURE 659F 759F 859E I 952F 1059F 1159F n ENTERING INDOOR WET BULB TEMPERATURE 0 IDIB AIRFLOW 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 1 67 71 m MBh 22,9 23.4 25.0 26.7 22.4 22.8 24.4 26.1 21.8 22.3 23.8 25.5 21.3 21.8 23.2 24.8 20.2 20.7 22.1 23.6 18.7 19.1 20.5 21.9 n S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57 p AT 26 25 22 17 26 25 22 18 26 25 22 18 27 25 22 18 26 25 22 17 24 23 20 16 EZ 700 kW 1.56 1.59 1.63 1.68 1.67 1.70 1.75 1.80 1.76 1.80 1.85 1.91 1.85 1.88 1.94 2.00 1.92 1.96 2.02 2.08 1.98 2.02 2.08 2.15 Z Amps. 5.8 5.9 6.1 6.3 6.2 6.4 6.6 6.8 6.8 6.9 7.1 7.4 7.2 7.4 7.6 7.9 7.7 7.9 8.1 8.4 8.1 8.3 8.6 8.9 p Hi PR 209 225 238 248 235 253 267 279 267 288 304 317 304 328 346 361 343 369 389 406 378 407 430 449 Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 MBh 23.2 23.7 25.4 27.1 22.7 23.2 24.8 26.5 22.2 22.6 24.2 25.9 21.6 22.1 23.6 25.2 20.5 21.0 22.4 24.0 19.0 19.4 20.8 22.2 S/T 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 _035, 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59 ATG)26 24 21 17 26 25 22 17 26 25 22 17 26 25 22 17 25 25 21 17 23 23 20' 16 (ig 80 750 kW 1.58 1.61 1.65 1.70 1.69 1.72 1.77 1.83 1.79 1.82 1.88 1.93 1.87 1.91 1.97 2.03 1.94 1.98 2.04 2.11 2.01 2.05 2.11 2.18 Amps 5.9 6.0 6.2 6.4 6.3 6.5 6.7 6.9 6.9 7.0 7.3 7.5 7.3 7.5 7.7 8.0 7.8 8.0 8.2 8.5 8.2 8.4 8.7 9.0 Hi PR 213 229 242 253 239 257 272 283 272 293 309 322 310 333 352 367 348 375 396 413 385 414 438 456 Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 1 152 129 137 150 160 133 142 155 165 MBh 24.1 24.6 26.3 28.1 23.5 24.0 25.6 27.4 22.9 23.4 25.0 26.8 22.4 22.9 24.4 26.1 21.3 21.7 23.2 24.8 19.7 20.1 21.5 23.0 S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62 ~' AT 23 22 19 16 24 23 20 16 23 23 20 16 23 23 20 16 22 22 20 16 20 21 18 15 900 kW 1.60 1.63 1.68 1.73 1.71 1.75 1.80 1.85 1.81 1.85 1.90 1.96 1.90 1.94 2.00 2.06 1.97 2.01 2.08 2.14 2.04 2.08 2.14 2.21 n Amps 6.0 6.1 6.3 6.5 6.4 6.6 6.8 7.1 7.0 7.2 7.4 7.7 7.5 7.6 7.9 8.2 7.9 8.1 8.4 8.7 8.4 8.6 8.9 9.2 a Hi PR 217 234 247 258 244 262 277 289 277 299 315 329 316 340 359 374 355 383 404 421 393 423 446 465 W :`1 Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168 W �3 C) ao MBh 23.3 23.7 24.9 26.5 22.7 23.2 24.3 25.9 22.2 22.6 23.7 25.3 21.7 22.1 23.1 24.7 20.6 21.0 22.0 23.4 19.1 19.4 20.4 21.7 (31 0 S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73 O 3 AT 28 27 26 22 28 28 26 23 28 28 26 23 28 28 26 23 27 27 26 22 25 26 24 21 + 700 kW 1.57 1.60 1.65 1.69 1.68 1.71 1.76 1.82 1.78 1.81 1.87 1.92 1.86 1.90 1.96 2.02 1.93 1.97 2.03 2.10 2.00 2.04 2.10 2.17 k Amps 5.8 6.0 6.2 6.4 6.3 6.4 6.6 6.9 6.8 7.0 7.2 7.5 7.3 7.5 7.7 8.0 7.7 7.9 8.2 8.5 8.2 8.4 8.7 9.0 Hi PR 212 228 240 251 237 255 270 281 270 291 307 320 308 331 349 365 346 372 393 410 382 411 434 453 n Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 158 133 141 154 164 p MBh 23.6 24.1 25.2 26.9 23.1 23.5 24.7 26.3 22.5 23.0 24.1 25.7 22.0 22.4 23.5 25.1 20.9 21.3 22.3 23.8 19.4 19.7 20.7 22.0 y S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76 AT 27 27 25 22 28 27 26 22 28 27 26 22 27 27 26 22 26 26 25 22 24 24 24 21 85 750 kW 1.59 1.62 1.67 1.72 1.70 1.73 1.79 1.84 1.80 1.83 1.89 1.95 1.89 1.92 1.98 2.04 1.96 2.00 2.06 2.12 2.02 2.06 2.13 2.20 Amps 5.9 6.1 6.3 6.5 6.4 6.5 6.7 7.0 6.9 7.1 7.3 7.6 7.4 7.6 7.8 8.1 7.9 8.0 8.3 8.6 8.3 8.5 8.8 9.1 Hi PR 215 232 245 25S 242 260 274 286 275 296 312 326 313 337 356 371 352 379 400 417 389 418 442 461 Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167 MBh 24.5 24.9 26.1 27.9 23.9 24.4 25.5 27.2 23.3 23.8 24.9 26.6 22.8 23.2 24.3 25.9 21.6 22.0 23.1 24.6 20.0 20.4 21.4 22.8 S/T 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81 AT 25 25 23 20 24 25 23 20 24 24 24 20 23 24 24 20 22 23 23 20 20 21 22 19 900 kW 1.61 1.64 1.69 1.74 1.73 1.76 1.81 1.87 1.83 1.86 1.92 1.98 1.91 1.95 2.01 2.08 1.99 2.03 2.09 2.16 2.OS 2.10 2.16 2.23 Amps 6.0 6.2 6.4 6.6 6.5 6.7 6.9 7.1 7.1 7.2 7.5 7.7 7.5 7.7 8.0 8.3 8.0 8.2 8.5 8.8 8.5 8.7 9.0 9.3 Ln Hi PR 220 236 249 260 246 265 280 292 280 302 318 332 319 343 363 378 359 386 408 426 397 427 451 470 LP Lo PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170 Gl X IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) rn High and low pressures are measured at the liquid and suction service valves. kW=Total system power N OUTDOOR AMBIENT TEMPERATURE U-) 652F 75°F 85RF 952F 1052F 1152F x ENTERING INDOOR WET BULB TEMPERATURE DL AIRFLOW 59 63 67 71 59 63 67 71 59 63 1 67 71 1 59 1 63 1 67 71 59 63 67 71 59 63 67 71 MBh 21.8 22.6 24.7 - 21.3 22.0 24.2 - 20.8 21.5 23.6 - 20.3 21.0 23.0 - 19.2 19.9 21.9 - 17.8 18.5 20.2 - S/T 0.68 0.57 0.39 0.70 0.59 0.41 0.72 0.60 0.42 0.74 0.62 0.43 0.77 0.64 0.45 0.78 0.65 0.45 AT 19.4 16.8 12.7 19.6 17.0 12.9 19.6 17.0 12.9 19.7 17.1 13.0 19.5 16.9 12.8 18.2 15.7 11.9 0 kW 1.24 1.27 1.31 1.34 1.37 1.42 1.43 1.46 1.52 1.51 1.55 1.60 1.58 1.62 1.67 1.64 1.68 1.73 Amps 5.2 5.3 5.5 5.6 5.8 5.9 6.1 6.2 6.4 6.5 6.6 6.9 6.9 7.1 7.3 7.3 7.5 7.7 Hi PR 200 216 228 225 242 255 256 275 291 291 313 331 328 353 372 362 389 411 Lo PR 104 111 121 110 117 128 114 121 133 120 128 139 126 134 146 130 138 151 MBh 22,5 23.3 25.5 21.9 22.7 24.9 21.4 22.2 24.3 20.9 21.6 23.7 19.8 20.6 22.5 18.4 19.1 20.9 S/T 0.69 0.58 0.40 0.72 0.60 0.41 0.73 0.61 0.42 0.76 0.63 0.44 0.79 0.66 0.46 0.79 0.66 0.46 AT 19.0 16.5 12.5 19.2 16.7 12.6 19.3 16.7 12.7 19.4 16.8 12.7 19.1 16.6 12.6 17.9 15.5 11.7 70 0 kW 1.26 1.29 1.33 1.36 1.39 1.44 1.45 1.49 1.54 1.53 1.57 1.62 1.60 1.64 1.70 1.66 1.70 1.76 Amps 5.3 S.4 5.6 5.7 5.8 6.0 6.2 6.3 6.5 6.6 6.7 7.0 7.0 7.2 7.4 7.4 7.6 7.8 Hi PR 204 219 232 229 246 260 260 280 296 296 319 337 333 359 379 368 396 418 LO PR 106 113 123 112 119 130 116 124 135 122 130 142 128 136 149 132 141 154 MBh 23.2 24.1 26.4 22.7 23.5 25.8 22.2 23.0 25.2 21.6 22.4 24.5 20.5 21.3 23.3 19.0 19.7 21.6 S/T 0.73 0.61 0.42 0.76 0.64 0.44 0.78 0.65 0.45 0.81 0.67 0.47 0.84 0.70 0.48 0.84 0.70 0.49 AT 17.4 15.1 11.5 17.6 15.3 11.6 17.7 15.3 11.6 17.8 15.4 11.7 17.5 15.2 11.5 16.4 14.2 10.8 0 kW 1.28 1.31 1.35 1.38 1.42 1.47 1.48 1.51 1.57 1.56 1.60 1.65 1.63 1.67 1.73 1.69 1.73 1.79 GQ Amps 5.4 5.5 5.7 5.8 5.9 6.1 6.3 6.4 6.6 6.7 6.9 7.1 7.1 7.3 7.5 7.5 7.7 8.0 m 0 Hi PR 208 224 236 233 251 265 265 285 301 302 325 343 340 366 386 376 404 427 CL Lo PR a 108 115 125 114 121 132 118 126 138 124 132 145 130 139 151 135 144 157 3 O MBh 22.1 22.8 24.7 26.5 21.6 22.3 24.1 25.9 21.1 21.7 23.5 25.3 20.621.2 23.0 24.6 19.6 20.2 21.8 23.4 18.1 18.7 20.2 21.7 p 0 S/T 0.77 0.69 0.52 0.33 0.80 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.37 0.88 0.78 0.59 0.38 0.88 0.79 0.60 0.38 n AT 22.4 20.6 16.9 11.7 22.6 20.9 17.1 11.8 22.7 20.9 17.1 11.8 22.8 21.0 17.2 11.9 22.5 20.7 17.0 11.7 21.0 19.4 15.9 11.0 0 kW 1.25 1.28 1.32 1.37 1.35 1.38 1.43 1.48 1.44 1.48 1.53 1.58 1.52 1.56 1.61 1.67 1.59 1.63 1.69 1.75 1.65 1.69 1.75 1.81 Amps 5.3 5.4 5.6 5.8 5.7 5.8 6.0 6.2 6.1 6.3 6.5 6.7 6.6 6.7 6.9 7.2 7.0 7.1 7.4 7.6 7.4 7.5 7.8 8.1 Hi PR 202 218 23D 1240 227 244 258 269 258 278 293 306 294 317 334 349 331 356 376 392 366 393 415 433 Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 153 162 y MBh 22.8 23.5 25.4 27.3 22.3 23.0 24.9 26.7 21.8 22.4 24.3 26.0 21.2 21.9 23.7 25.4 20.2 20.8 22.5 24.1 18.7 19.2 20.8 22.4 S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.80 0.61 0.39 0.90 0.81 0.61 0.39 AT 22.0 20.2 16.6 11.4 22.2 20.5 16.8 11.6 22.3 20.5 16.8 11.6 22.4 20.7 16.9 11.7 22.1 20.4 16.7 11.5 20.7 19.0 15.6 10.8 M 75 0 kW 1.27 1.30 1.34 1.39 1.37 1.40 1.45 1.50 1.47 1.50 1.55 1.61 1.55 1.58 1.64 1.70 1.62 1.66 1.71 1.77 1.68 1.72 1.78 1.84 k Amps 5.3 5.5 5.6 5.8 5.8 5.9 6.1 6.3 6.2 6.4 6.6 6.8 6.7 6.8 7.0 7.3 7.1 7.2 7.5 7.7 7.5 7.7 7.9 8.2 kA Hi PR 206 222 234 244 231 249 263 274 263 283 299 311 299 322 340 355 337 362 383 399 372 400 423 441 � LO PR 107 114 124 132 113 120 131 140 117 125 136 145 . 123 131 143 152 129 137150 160 134 142 155 165 NJ MBh 23.6 24.3 26.3 28.3 23.1 23.8 25.7 27.6 22.5 23.2 25.1 27.0 22.0 22.6 24.5 26.3 20.9 21.5 23.3 25.0 19.3 19.9 21.6 23.1 9F S/T 0.83 0.75 0.56 0.36 0.86 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.6S 0.42 AT 20.1 18.6 1S.2 10.5 20.4 18.8 15.4 10.6 20.4 18.8 15.4 10.6 20.6 18.9 15.5 10.7 20.3 18.7 15.3 10.6 18.9 17.4 14.3 9.9 n 0 kW 1.29 1.32 1.36 1.41 1.40 1.43 1.48 1.53 1.49 1.53 1.58 1.64 1.58 1.61 1.67 1.73 1.65 1.68 1.74 1.81 1.71 1.75 1.81 1.87 Amps 5.4 5.6 5.7 5.9 5.9 6.0 6.2 6.4 6.4 6.5 6.7 7.0 6.8 . 6.9 7.2 7.4 7.2 7.4 7.6 7.9 7.6 7.8 8.0 8.3 W Hi PR 210 226 239 249 236 254 268 279 268 288 305 318 305 328 347 362 343 370 390 407 379 408 431 450 W Lo PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 156 132 140 153 163 1 136 145 158 169 (31 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions HI PR=PRESSURE AT LIQUID SERVICE VALVE,PSIG Amps=outdoor unit amps(camp.+fan) O High and low pressures are measured at the liquid and suction service valves. MBH=NETTOTAL CAPACITY(i000 BTU/HR) LO PR=PRESSURE AT VAPOR SERVICE VALVE,PSIG M=Total system power S/T=SENSIBLE TO TOTAL CAPACITY RATIO N OUTDOOR AMBIENT TEMPERATURE k 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE Z D: AIRFLOWrri� MBh 22,5 23.0 24.6 26.3 22.0 22.5 24.0 25.7 21.5 22.0 23.5 25.1 21.0 21.4 22.9 24.5 19.9 20.4 21.7 23.2 18.5 18.9 20.1 21.5 0 S/T 0.84 0.79 0.64 0.48 0.87 0.82 0.67 0.50 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.97 0.91 0.74 0.55 p AT 25.0 23.9 20.8 16.6 25.3 24.2 21.1 16.8 25.3 24.2 21.1 16.8 25.5 24.4 21.2 17.0 25.1 24.1 20.9 16.7 23.5 22.5 19.6 15.6 0 kW 1.26 1.29 1.33 1.38 1.36 1.40 1.44 1.49 1.46 1.49 1.54 1.60 1.54 1.57 1.63 1.69 1.61 1.65 1.70 1.76 1.67 1.71 1.77 1.83 Z Amps 5.3 5.4 5.6 5.8 5.7 5.9 6.0 6.3 6.2 6.3 6.5 6.8 6.6 6.8 7.0 7.2 7.0 7.2 7.4 7.7 7.4 7.6 7.9 8.1 Hi PR 204 220 232 242 229 247 261 272 261 281 296 309 297 320 338 352 334 360 380 396 369 397 420 438 Lo PR 106 113 123 131 112 119 130 139 117 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164 MBh 23.2 23.7 25.4 27.1 22.7 23.2 24.8 26.5 22.2 22.6 24.2 25.9 21.6 22.1 23.6 25.2 20.5 21.0 22.4 24.0 19.0 19.4 20.8 22.2 S/T 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.75 0.56 AT 24.5 23.5 20.4 16.3 24.8 23.8 20.7 16.5 24.9 23.8 20.7 16.6 25.0 24.0 20.9 16.7 24.7 23.7 20.6 16.4 23.1 22.1 19.2 15.4 80 0 kW 1.28 1.31 1.35 1.40 1.39 1.42 1.47 1.52 1.48 1.51 1.57 1.62 1.56 1.60 1.65 1.71 1.63 1.67 1.73 1.79 1.69 1.73 1.79 1.86 N Amps 5.4 5.5 5.7 5.9 5.8 5.9 6.1 6.4 6.3 6.4 6.7 6.9 6.7 6.9 7.1 7.4 7.1 7.3 7.5 7.8 7.5 7.7 8.0 8.3 Ln Hi PR 208 224 236 246 233 251 265 277 265 286 302 315 302 325 343 358 340 366 386 403 376 404 427 445 Lo PR 108 115 125 134 114 121 132 141 119 126 138 147 125 132 145 154 130 139 152 161 135 144 157 167 N MBh 24.1 24.6 26.3 28.1 23.5 24.0 25.6 27.4 22.9 23.4 25.0 26.8 22.4 22.9 24.4 26.1 21.3 21.7 23.2 24.8 19.7 20.1 21.5 23.0 dF S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 1.00 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 1.00 0.80 0.59 1.00 1.00 0.80 0.60 n AT 22.5 21.6 18.7 15.0 22.8 21.8 19.0 15.2 23.4 21.8 19.0 15.2 22.9 22.0 19.1 15.3 21.7 22.2 18.9 15.1 20.1 20.6 17.6 14.1 0 kW 1.30 1.33 1.38 1.42 1.41 1.44 1.49 1.54 1.50 1.54 1.59 1.65 1.59 1.63 1.68 1.74 1.66 1.70 1.76 1.82 1.72 1.76 1.83 1.89 Amps 5.5 5.6 5.8 6.0 5.9 6.1 6.2 6.5 6.4 6.6 6.8 7.0 6.8 7.0 7.2 7.5 7.3 7.4 7.7 8.0 7.7 7.9 8.1 8.4 L CL Hi PR 212 228 241 251 238 256 270 282 271 291 308 321 308 332 350 365 347 373 394 411 383 412 435 454 � v Lo PR 1 110 117 128 136 1 116 124 135 144 1 121 129 140 150 127 135 148 157 133 142 155 165 138 146 160 170 � O �+ MBh 22,9 23,4 24.5 26.1 22.4 22.8 23.9 25.5 21.9 22.3 23.3 24.9 21.3 21.7 22.8 24.3 20.3 20.7 21.6 23.1 18.8 19.1 20.0 21.4 C) S/T 0.88 0.85 0.77 0.62 0.92 0.88 0.80 0.65 0.94 0.91 0.82 0.66 0.97 0.94 0.84 0.69 1.00 0.97 0.88 0.71 1.00 0.98 0.88 0.72 :1 AT 26.6 26.2 24.8 21.4 27.0 26.5 25.1 21.7 27.0 26.5 25.1 21.7 27.2 26.7 25.3 21.9 26.6 26.4 24.9 21.6 24.7 24.6 23.3 20.1 Z 0 kW 1.27 1.30 1.34 1.39 1.38 1.41 1.46 1.51 1.47 1.50 1.56 1.61 1.55 1.59 1.64 1.70 1.62 1.66 1.72 1.78 1.68 1.72 1.78 1.85 Amps 5.4 S.S 5.7 5.9 5.8 5.9 6.1 6.3 6.3 6.4 6.6 6.8 6.7 6.8 7.0 7.3 7.1 7.3 7.5 7.8 7.5 7.7 7.9 8.2 Hi PR 206 222 235 245 232 249 263 275 263 284 299 312 300 323 341 356 338 363 384 400 373 401 424 442 Lo PR 107 114 124 133 113 120 132 140 118 125 137 146 124 132 144 153 130 138 150 160 134 143 156 166 MBh 23.6 24.1 25.2 26.9 23.1 23.5 24.7 26.3 22.5 23.0 24.1 25.7 22.0 22.4 23.5 25.1 .20.9 21.3 22.3 23.8 19.4 19.7 20.7 22.0 S/T 0.90 0.87 0.79 0.64 0.94 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.90 0.73 AT 26.2 25.7 24.3 21.1 26.5 26.1 24.6 21.3 26.5 26.1 24.7 21.3 26.7 26.3 24.8 21.5 25.6 25.9 24.5 21.2 23.7 24.2 22.9 19.8 85 0 kW 1.29 1.32 1.36 1.41 1.40 1.43 1.48 1.53 1.49 1.53 1.58 1.64 1.58 1.61 1.67 1.73 1.65 1.69 1.74 1.81 1.71 1.75 1.81 1.87 Amps 5.4 5.6 5.7 5.9 5.9 6.0 6.2 6.4 6.4 6.5 6.7 7.0 6.8 6.9 7.2 7.4 7.2 7.4 7.6 7.9 7.6 7.8 8.0 8.3 Hi PR 210 226 239 249 236 254 268 279 268 288 305 318 305 329 347 362 343 370 390 407 379 408 431 450 Lo PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 MBh 24.5 24.9 26.1 27.9 23.9 24.4 25.5 27.2 23.3 23.8 24.9 26.6 22.8 23.2 24.3 25.9 21.6 22.0 23.1 24.6 20.0 20.4 21.4 22.8 S/T 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 AT 24.0 23.6 22.3 19.3 24.3 23.9 22.6 19.5 23.8 23.9 22.6 19.6 23.3 23.7 22.8 19.7 22.1 22.5 22.4 19.4 20.5 20.9 21.0 18.1 0 kW 1.31 1.34 1.39 1.44 1.42 1.45 1.50 1.56 1.52 1.55 1.61 1.66 1.60 1.64 1.70 1.76 1.68 1.72 1.78 1.84 1.74 1.78 1.84 1.91 Amps 5.5 5.7 5.8 6.0 6.0 6.1 6.3 6.5 6.5 6.6 6.8 7.1 6.9 7.1 7.3 7.6 7.3 7.5 7.7 8.0 7.7 7.9 8.2 8.5 Hi PR 214 231 243 254 240 259 273 285 273 294 311 324 311 335 354 369 350 377 398 415 387 417 440 459 rr"n Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172 G1 r" IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions HI PR=PRESSURE AT LIQUID SERVICE VALVE,PSIG Amps=outdoor unit amps(comp.+fan) X 00) High and low pressures are measured at the liquid and suction service valves. MBH=NET TOTAL CAPACITY(1000 BTU/HR) LO PR=PRESSURE AT VAPOR SERVICE VALVE,PSIG kW=Total system power S/T=SENSIBLE TO TOTAL CAPACITY RATIO vNi - OUTDOOR AMBIENT TEMPERATURE L� 65°F 752F 852F 952F 1052F 1152F FX-+ ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 1 59 63 67 71 59 63 67 71 59 63 1 67 71 1 59 1 63 1 67 71 59 63 67 71 59 63 67 71 MBh 25.5 26.4 28.9 - 24.9 25.8 28.2 - 24.3 25.2 27.6 - 23.7 24.6 26.9 - 22.5 23.3 25.6 - 20.8 21.6 23.7 - S/T 0.70 0.59 0.41 0.73 0.61 0.42 0.75 0.62 0.43 0.77 0.64 0.45 0.80 0.67 0.46 0.81 0.67 0.47 AT 19 16 12 19 16 12 19 16 13 19 17 13 19 16 12 18 15 12 875 kW 1.87 1.90 1.96 2.00 2.04 2.10 2.11 2.15 2.22 2.21 2.26 2.32 2.30 2.34 2.41 2.37 2.42 2.49 Amps 6.8 6.9 7.1 7.3 7.5 7.7 7.9 8.1 8.4 8.5 8.7 9.0 9.0 9.2 9.5 9.5 9.8 10.1 Hi PR 214 230 243 240 258 272 272 293 310 310 334 353 349 376 397 386 415 438 Lo PR 104 110 120 109 116 127 114 121 132 119 127 139 125 133 145 130 138 150 MBh 27.6 28.6 31.3 26.9 27.9 30.6 26.3 27.3 29.9 25.7 26.6 29.1 24.4 25.3 27.7 22.6 23.4 25.6 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 0.70 0.48 AT 18 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 15 11 70 1000 kW 1.91 1.95 2.00 2.04 2.08 2.14 2.16 2.20 2.27 2.26 2.31 2.38 2.35 2.40 2.47 2.43 2.48 2.55 Amps 6.9 7.1 7.3 7.5 7.7 7.9 8.2 8.3 8.6 8.7 8.9 9.2 9.3 9.5 9.8 9.8 10.1 10.4 Hi PR 220 237 250 247 266 281 281 302 319 320 344 364 360 387 409 398 428 452 Lo PR 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 134 142 155 MBh 28.4 29.5 32.3 27.8 28.8 31.5 27.1 28.1 30.8 26.4 27.4 30.0 25.1 26.0 28.5 23.3 24.1 26.4 m S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.73 0.50 0.88 0.73 0.51 :E AT 18 15 12 18 16 12 18 16 12 18 16 12 18 15 12 17 14 11 n 1125 kW 1.92 1.96 2.02 2.06 2.10 2.16 2.18 2.22 2.29 2.28 2.33 2.40 2.37 2.42 2.49 2.45 2.50 2.57 D rn o Amps 7.0 7.2 7.4 7.6 7.8 8.0 8.2 8.4 8.7 8.8 9.0 9.3 9.4 9.6 9.9 9.9 10.1 10.5 p 0 Hi PR 222 239 253 249 268 283 284 305 322 323 348 367 364 391 413 402 432 456 On v Lo PR 108 115 125 114 121 132 118 126 138 124 132 145 130 139 151 135 143 157 3 Z oar' MBh 25.9 26.7 28.9 31.0 25.3 26.0 28.2 30.3 24.7 25.4 27.5 29.5 24.1 24.8 26.8 28.8 22.9 23.6 25.5 27.4 21.2 21.8 23.6 25.4 G) o S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40 O AT 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 16 11 20 19 15 11 y 875 kW 1.88 1.92 1.97 2.03 2.01 2.05 2.11 2.17 2.13 2.17 2.23 2.30 2.23 2.27 2.34 2.41 2.31 2.36 2.43 2.51 2.39 2.44 2.51 2.59 n Amps 6.8 7.0 7.2 7.5 7.4 7.5 7.8 8.1 8.0 8.2 8.5 8.8 8.5 8.8 9.0 9.4 9.1 9.3 9.6 10.0 9.6 9.9 10.2 10.6 Hi PR 216 232 245 256 242 260 275 287 275 296 313 326 314 337 356 372 353 380 401 418 390 419 443 462 Lo PR 105 111 122 129 111 118 128 137 115 122 133 142 121 128 140 149 127 135 147 156 131 139 152 162 MBh 28.1 28.9 31.3 33.6 27.4 28.2 30.5 32.8 26.8 27.5 29.8 32.0 26.1 26.9 29.1 31.2 24.8 25.5 27.6 29.7 23.0 23.6 25.6 27.5 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 p AT 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 L 75 1000 kW 1.92 1.96 2.02 2.08 2.06 2.10 2.16 2.22 2.18 2.22 2.29 2.36 2.28 2.33 2.40 2.47 2,37 2.42 2.49 2.57 2.45 2.50 2.57 2.66 O Amps 7.0 7.2 7.4 7.7 7.6 7.8 8.0 8.3 8.28.4 8.7 9.0 8.8 9.0 9.3 9.7 9.4 9.6 9.9 10.3 9.9 10.2 10.5 10.9 Hi PR 222 239 253 264 250 269 284 296 284 305 322 336 323 348 367 383 364 391 413 431 402 432 457 476 Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 144 157 167 MBh 28.9 29.8 32.2 34.6 28.2 29.1 31.5 33.8 27.6 28.4 30.7 33.0 26.9 27.7 30.0 32.2 25.5 26.3 28.5 30.5 23.7 24.4 26.4 28.3 S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 . 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43 AT 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 WV 1125 kW 1.94 1.97 2.03 2.09 2.07 2.11 2.18 2.24 2.19 2.24 2.30 2.37 2.30 2.35 2.42 2.49 2.39 2.44 2.51 2.59 2.47 2.52 2.60 2.68 p W Amps 7.1 7.2 7.5 7.8 7.6 7.8 8.1 8.4 8.3 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.7 10.0 10.4 10.0 10.2 10.6 11.0 Hi PR 225 242 255 266 252 271 286 299 287 308 326 340 326 351 371 387 367 395 417 435 406 437 461 481 Lo PR 1 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) x LU High and low pressures are measured at the liquid and suction service valves. kW=Total system power .gyp OUTDOOR AMBIENT TEMPERATURE k 659F 759F 859E 1 952F 1059F 1152F ENTERING INDOOR WET BULB TEMPERATURE - 0 3: m MBh' 26.4 26.9 28.8 30.8 25.7 26.3 28.1 30.0 25.1 25.7 27.4 29.3 24.5 25.1 26.8 28.6 23.3 23.8 25.4 27.2 21.6 22.0 23.6 25.2 n S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 p AT 24 23 20 16 25 24 20 16 25 24 20 16 25 24 21 16 24 23 20 16 23 22 19 15 EZ 875 kW 1.90 1.93 1.99 2.04 2.03 2.07 2.13 2.19 2.14 2.19 2.25 2.32 2.25 2.29 2.36 2.43 2.33 2.38 2.45 2.53 2.41 2.46 2.53 2.61 Z Amps 6.9 7.0 7.3 7.5 7.4 7.6 7.9 8.2 8.1 8.3 8.5 8.9 8.6 8.8 9.1 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.7 G) Hi PR 218 234 248 258 244 263 278 290 278 299 316 330 317 341 360 375 356 383 405 422 394 424 447 467 Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 154 163 MBh 28.6 29.2 31.2 33.3 27.9 28.5 30.5 32.6 27.2 27.8 29.7 31.8 26.6 27.1 29.0 31.0 25.2 25.8 27.6 29.5 23.4 23.9 25.5 27.3 S/T 0.91. 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 AT 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 21 19 15 Ln 80 1000 kW 1.94 1.97 2.03 2.09 2.07 2.11 2.18 2.24 2.19 2.24 2.30 2.37 2.30 2.35 2.42 2.49 2.39 2.44 2.51 2.59 2.47 2.52 2.60 2.68 N Amps 7.1 7.2 7.5 7.8 7.6 7.8 8.1 8.4 8.3 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.7 10.0 10.4 10.0 10.2 10.6 11.0 Hi PR 225 242 255 266 252 271 286 299 287 308 326 340 326 351 371 387 367 395 417 435 406 437 461 481 O Lo PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169 Lei165 MBh29.4 30.1 32.1 34.3 28.7 29.4 31.4 33.5 28.0 28.7 30.6 32.7 27.4 28.0 29.9 31.9 26.0 26.6 28.4 30.3 24.1 24.6 26.3 28.1 (Z) O S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62 4 AT 23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 16 21 22 19 15 20 20 18 14 :E 1125 kW 1.95 1.99 2.05 2.11 2.09 2.13 2.19 2.26 2.21 2.25 2.32 2.39 2.32 2.36 2.44 2.51 2.41 2.46 2.53 2.61 2.48 2.54 2.62 2.70 n o Amps 7.1 7.3 7.5 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.5 10.1 10.3 10.7 11.1 a Hi PR 227 244 258 269 255 274 289 302 290 312 329 343 330 355 375 391 371 399 422 440 410 441 466 486 (Tu o3i Lo PR 110 117 128 136 116 124 135 144 121 129 140 150 127 135 147 157 133 142 155 165 138 146 160 170 A LAJ MBh 26.8 27.3 28.6 30.5 26.2 26.7 28.0 29.8 25.6 26.1 27.3 29.1 24.9 25.4 26.6 28.4 23.7 24.2 25.3 27.0 22.0 22.4 23.4 25.0 (0) o S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74 3 AT 26 25 24 21 26 26 24 21 26 26 24 21 26 26 25 21 25 25 24 21 23 24 23 20 F 875 kW 1.91 1.95 2.00 2.06 2.04 2.08 2.14 2.21 2.16 2.20 2.27 2.34 2.26 2.31 2.38 2.45 2.35 2.40 2.47 2.55 2.43 2.48 2.55 2.63 k Amps 6.9 7.1 7.3 7.6 7.5 7.7 7.9 8.2 8.1 8.3 8.6 8.9 8.7 8.9 9.2 9.6 9.3 9.5 9.8 10.2 9.8 10.1 10.4 10.8 C Hi PR 220 237 250 261 247 266 281 293 281 302 319 333 320 344 363 379 360 387 409 426 398 428 452 471 O Lo PR 107 114 124 132 113 120 131 140 117 12S 136 145 123 131 143 152 129 137 150 '160 133 142 155 165 Z MBh 29.1 29.6 31.0 33.1 28.4 28.9 30.3 32.3 27.7 28.2 29.6 31.6 27.0 27.6 28.9 30.8 25.7 26.2 27.4 29.2 23.8 24.2 25.4 27.1 �~ S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 AT 2S 25 24 20 26 25 24 21 25 25 24 21 25 25 24 21 24 24 24 21 22 22 22 19 85 1000 kW 1.95 1.99 2.05 2.11 2.09 2.13 2.19 2.26 2.21 2.25 2.32 2.39 2.32 2.36 2.44 2.51 2.41 2.46 2.53 2.61 2.48 2.54 2.62 2.70 Amps 7.1 7.3 7.5 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.5 10.1 10.3 10.7 11.1 Hi PR 227 244 258 269 255 274 289 302 290 312 329 343 330 355 375 391 371 399 422 440 410 441 466 486 Lo PR 110 117 128 136 116 124 135 144 121 129 140 150 127 135 147 157 133 142 155 165 138 146 160 170 MBh 29.9 30.5 31.9 34.1 29.2 29.8 31.2 33.3 28.5 29.1 30.5 32.5 27.8 28.4 29.7 31.7 26.4 27.0 28.2 30.1 24.5 25.0 26.2 27.9 S/T 1.00 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.D0 1.00 0.99 0.80 1.00 1.00 1.00 0.81 AT 24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 22 22 23 20 20 20 21 18 1125 kW 1.97 2.00 2.06 2.12 2.10 2.15 2.21 2.28 2.23 2.27 2.34 2.41 2.33 2.38 2.45 2.53 2.43 2.48 2.55 2.63 2.50 2.56 2.64 2.72 Amps 7.2 7.4 7.6 7.9 7.8 8.0 8.2 8.5 8.5 8.7 8.9 9.3 9.0 9.3 9.6 9.9 9.6 9.9 10.2 10.6 10.2 10.4 10.8 11.2 Hi PR 229 247 260 272 257 277 292 305 292 315 332 347 333 358 378 395 375 403 426 444 414 445 470 491 Ln LO PIR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172 Ln IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) rn High and low pressures are measured at the liquid and suction service valves. kW=Total system power cNiOUTDOOR AMBIENT TEMPERATURE N 652F 752F 852F 959F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 59 63 67 71 S9 63 1 67 71 5963 67 71 59 63 1 67 71 59 63 67 71 59 63 67 71 MBh 29.1 29.5 30.4 --- 28.8 29.2 30.1 --- 28.1 28.5 29.4 --- 26.8 27.2 28.0 --- 25.2 25.6 26.5 --- 23.7 24.1 25.0 --- S/T 0.62 0.54 0.40 --- 0.63 0.55 0.41 --- 0.65 0.57 0.44 --- 0.67 0.59 0.46 --- 1.00 0.62 0.48 --- 1.00 0.67 0.53 --- AT 20 18 15 --- 20 18 15 --- 20 18 15 20 18 15 --- 20 18 14 --- 21 19 15 --- 875 kW 1.67 1.67 1.67 --- 1.86 1.86 1.86 --- 2.07 2.07 2.07 - 2.30 2.30 2.30 --- 2.55 2.55 2.55 --- 2.85 2.85 2.85 --- Amps 6.0 6.0 6.0 --- 6.9 6.8 6.8 --- 7.8 7.8 7.8 --- 8.9 8.8 8.8 --- 10.0 10.0 10.0 --- 11.4 11.4 11.4 --- Hi PR 241 242 244 --- 280 281 282 --- 319 321 322 --- 362 363 365 --- 409 410 412 --- 458 459 461 --- Lo PR 123 125 128 --- 130 132 135 --- 137 139 142 --- 143 144 147 --- 148 150 153 --- 155 156 159 --- MBh 29.5 29.9 30.8 --- 29.2 29.6 30.S --- 28.5 28.9 29.7 --- 27.2 27.6 28.4 --- 25.6 26.0 26.8 --- 24.1 24.5 25.4 --- S/T 0.68 0.60 0.47 --- 0.69 0.61 0.47 --- 0.71 0.64 0.50 --- 1.00 0.66 0.52 --- 1.00 0.68 0.54 --- 1.00 0.73 0.59 --- AT 19 17 13 --- 19 17 13 --- 19 17 14 --- 19 17 13 --- 18 17 13 -- 20 18 14 --- 70 1000 kW 1.68 1.68 1.68 --- 1.87 1.87 1.87 --- 2.08 2.08 2.08 --- 2.31 2.31 2.31 2.56 2.56 2.56 --- 2.86 2.86 2.86 --- Amps 6.0 6.0 6.0 --- 6.9 6.9 6.9 --- 7.9 7.9 7.8 --- 8.9 8.9 8.9 10.1 10.1 10.0 --- 11.4 11.4 11.4 --- Hi PR 243 245 246 --- 282 283 284 --- 322 323 324 --- 364 366 367 --- 411 412 414 --- 460 461 463 --- m Lo PR 125 126 129 --- 132 134 137 --- 139 140 144 --- 144 146 149 --- 150 151 154 --- 157 158 161 --- M13h 29.9 30.3 31.2 --- 29.7 30.1 31.0 --- 28.9 29.3 30.2 --- 27.6 28.0 28.9 --- 26.0 26.4 27.3 --- 24.6 25.0 25.8 --- n S/T 0.72 0.64 0.50 --- 0.72 0.65 0.51 --- 0.75 0.67 0.53 --- 1.00 0.69 0.55 --- 1.00 0.71 0.57 --- 1.00 0.77 0.63 O g AT 18 16 13 --- 18 16 12 --- 18 16 13 --- 18 16 12 --- 17 16 12 --- 19 17 13 p 1125 kW 1.69 1.69 1.69 --- 1.88 1.88 1.88 --- 2.09 2.09 2.09 --- 2.32 2.32 2.31 -- 2.57 2.57 2.57 --- 2.87 2.87 2.87 --- n oAmps 6.1 6.1 6.1 --- 6.9 6.9 6.9 --- 7.9 7.9 7.9 --- 8.9 8.9 8.9 --- 10.1 10.1 10.1 --- 11.5 11.5 11.4 O Hi PR 245 247 248 --- 284 285 286 --- 323 325 326 --- 366 368 369 --- 413 414 416 --- 462 463 465 --- 3 Lo PR 127 128 131 --- 134 136 139 --- 141 142 146 --- 146 148 151 --- 1S2 153 156 --- 159 160 163 3 oa MBh 29.1 29.5 30.4 31.7 28.9 29.3 30.1 31.5 28.1 28.5 29.4 30.7 26.8 27.2 28.1 29.4 25.2 25.6 26.5 27.8 23.7 24.1 25.0 26.3 y o S/T 0.75 0.68 0.54 0.39 0.76 0.68 0.54 0.40 1.00 0.71 0.57 0.42 1.00 0.73 0.59 0.44 1.00 0.75 0.61 0.46 1.00 1.00 0.66 0.52 n AT 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 18 15 25 23 19 16 875 kW 1.67 1.67 1.67 1.68 1.86 1.86 1.86 1.87 2.07 2.07 2.07 2.08 2.30 2.30 2.29 2.31 2.55 2.55 2.55 2.56 2.85 2.85 2.85 2.86 G) Amps 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 k Hi PR 242 243 244 249 280 281 282 287 320 321 322 327 363 364 365 370 409 410 412 416 458 459 461 465 ~' O^1 Lo PR 123 125 128 133 131 132 135 140 137 139 142 147 143 144 147 153 148 150 153 158 155 156 160 165 O MBh 29.5 29.9 30.8 32.1 29.2 29.6 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.4 29.8 2S.6 26.0 26.9 28.2 24.1 24.5 25.4 26.7 IN N S/T 0.81 0.74 0.60 0.45 0.82 0.74 0.60 0.46 1.00 0.77 0.63 0.48 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.53 1.00 1.00 0.73 0.58 AT 23 21 18 14 23 21 17 14 23 21 18 14 23 21 17 14 22 21 17 14 24 22 18 15 75 1000 kW 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 2.30 2.32 2.56 2.56 2.56 2.57 2.86 2.86 2.86 2.87 w O Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.9 7.8 7.8 7.9 8.9 8.9 8.9 8.9 10.1 10.1 10.0 10.1 11.4 11.4 11.4 11.5 64 Hi PR 244 245 246 251 282 283 285 289 322 323 324 329 365 366 367 372 411 412 414 418 460 462 463 467 Lo PR 125 126 129 135 132 134 137 142 139 140 144 149 144 146 149 154 150 151 155 160 157 158 161 167 n MBh 30.0 30.4 31.2 32.6 29.7 30.1 31.0 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 .25.9 27.2 n S/T 0.85 0.77 0.63 0.49 1.00 0.78 0.64 0.49 1.00 0.80 0.66 0.52 1.00 0.82 0.68 0.54 1.00 0.85 0.71 0.56 1.00 1.00 0.76 0.61 AT 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 17 14 V 1125 kW 1.69 1.69 1.69 1.70 1.88 1.88 1.87 1.89 2.09 2.09 2.08 2.10 2.32 2.32 2.31 2.33 2.57 2.57 2.57 2.58 2.87 2.87 2.86 2.88 W Amps 6.1 6.1 6.0 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.5 11.5 11.4 11.5 Hi PR 246 247 248 253 284 285 287 291 324 325 326 331 367 368 369 374 413 414 416 420 462 464 465 469 Lo PR 127 128 132 137 134 136 139 144 141 142 146 151 146 148 151 156 152 153 157 162 159 160 163 169 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) Lri High and low pressures are measured at the liquid and suction service valves. kW=Total system power F. OUTDOOR AMBIENT TEMPERATURE k 652F 752F 852F 952F 1052F 1152F n ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 59 63 67 71 .59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 29.3 29.7 30.5 31.9 29.0 29.4 30.3 31.6 28.2 28.7 29.5 30.9 26.9 27.3 28.2 29.5 25.3 25.8 26.6 27.9 23.9 24.3 25.2 26.5 to S/T 1.00 0.80 0.66 0.52 1.00 0.81 0.67 0.52 1.00 0.84 0.70 0.55 1.00 0.86 0.72 0.57 1.00 1.00 0.74 0.59 1.00 1.00 0.79 0.65 p AT 28 26 23 19 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 29 27 24 20 O 875 kW 1.67 1.67 1.67 1.68 1.86 1.86 1.86 1.87 2.07 2.07 2.07 2.08 2.30 2.30 2.30 2.31 2.55 2.55 2.55 2.56 2.85 2.85 2.85 2.86 Z Amps 6.0 6.0 6.0 6.0 6.9 6.8 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 242 243 245 249 280 281 283 287 320 321 323 327 363 364 366 370 409 410 412 416 459 460 462 466 Lo PR 124 125 128 133 131 133 136 141 138 139 142 148 143 145 148 153 149 150 153 158 155 157 160 165 n MBh 29.6 30.1 30.9 32.3 29.4 29.8 30.7 32.0 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.5 26.9 S/T 1.00 0.87 0.73 0.58 1.00 0.87 0.73 0.59 1.00 0.90 0.76 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.85 0.71 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 27 25 21 18 28 26 22 19 (n 80 1000 kW 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 i 2.30 j 2.32 2.56 2.56 2.56 2.57 2.86 2.86 2.86 2.87 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.9 7.9 7.8 7.9 8.9 8.9 8.9 8.9 10.1 10.1 10.0 10.1 11.4 11.4 11.4 11.5 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 411 413 414 418 461 462 464 468 Uj Lo PR 125 127 130 135 133 134 138 143 139 141 144 149 145 146 150 155 150 152 155 160 157 159 162 167 MBh 30.1 30.5 31.4 32.7 29.8 30.3 31.1 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.7 25.1 26.0 27.3 S/T 1.00 0.90 0.76 0.61 1.00 0.91 0.77 0.62 1.00 0.93 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.89 0.74 W AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 27 25 21 18 O 1125 kW 1.69 1.69 1.69 1.70 1.88 1.88 1.88 1.89 2.09 2.09 2.09 2.10 2.32 2.32 2.31 2.33 2.57 2.57 2.57 2.58 2.87 2.87 2.86 2.88 o Amps 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.5 11.5 11.4 11.5 a Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 415 416 420 463 464 466 470 S Lo PR 1 127 129 132 137 1 135 136 140 145 1 141 143 146 151 1 147 148 152 157 1 152 154 157 162 1 159 161 164 169 66,� W MBh 29.8 30.2 31.0 32.4 29.5 29.9 30.8 32.1 28.7 29.1 30.0 31.3 27.4 27.8 28.7 '30.0 25.8 26.2 27.1 28.4 24.4 24.8 25.7 27.0 o S/T 1.00 0.91 0.77 0.62 1.00 0.91 0.77 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.84 0.70 1.00 1.00 1.00 0.75 Uj 3 AT 32 30 26 23 31 30 26 23 32 30 26 23 31 30 26 23 31 29 26 22 32 31 27 24 Ol 875 kW 1.68 1.68 1.67 1.69 1.87 1.86 1.86 1.88 2.08 2.07 2.07 2.09 2.30 2.30 2.30 2.31 2.56 2.56 2.55 2.57 2.86 2.85 2.85 2.86 iE Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.8 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 y Hi PR 243 244 246 250 281 282 284 288 321 322 324 328 364 365 367 371 411 412 413 418 460 461 463 467 Lo PR 125 127 130 135 133 134 138 143 139 141 144 149 145 147 150 155 150 152 155 160 157 159 162 167 MBh 30.1 30.S 31.4 32.7 29.9 30.3 31.2 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.8 25.2 26.0 27.4 0 S/T 1.00 0.97 0.83 0.68 1.00 1.00 0.84 0.69 1.00 1.00 0.86 0.72 1.00 1.00 0.88 0.74 1.00 1.00 0.90 0.76 1.00 1.00 1.00 0.81 Z AT 30 29 25 22 30 29 25 22 31 29 25 22 30 29 25 22 30 28 25 21 31 29 26 22 85 1000 kW 1.69 1.69 1.68 1.70 1.88 1.87 1.87 1.89 2.09 2.08 2.08 2.10 2.31 2.31 2.31 2.32 2.57 2.57 2.56 2.58 2.87 2.86 2.86 2.87 Am ps 6.1 6.0 6.0 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.1 10.1 10.1 10.1 11.4 11.4 11.4 11.5 Hi PR 245 246 248 252 283 284 286 290 323 324 326 330 366 367 369 373 413 414 415 420 462 463 465 469 Lo PR 127 129 132 137 135 136 139 145 141 143 146 151 147 148 151 157 152 154 157 162 159 161 164 169 MBh 30.6 31.0 31.9 33.2 30.3 30.7 31.6 32.9 29.6 30.0 30.9 32.2 28.3 28.7 29.5 30.9 26.7 27.1 28.0 29.3 25.2 25.6 26.5 27.8 S/T 1.00 1.00 0.86 0.72 1.00 1.00 0.87 0.72 1.00 1.00 0.90 0.75 1.00 1.00 0.92 0.77 1.00 1.00 1.00 0.79 1.00 1.00 1.00 0.85 AT 29 28 24 21 29 28 24 21 30 28 24 21 29 28 24 21 29 27 24 20 30 28 25 22 1125 kW 1.70 1.69 1.69 1.71 1.88 1.88 1.88 1.89 2.09 2.09 2.09 2.10 2.32 2.32 2.32 2.33 2.58 2.57 2.57 2.59 2.87 2.87 2.87 2.88 Amps 6.1 6.1 6.1 6.1 7.0 6.9 6.9 7.0 7.9 7.9 7.9 8.0 9.0 8.9 8.9 9.0 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 Hi PR 247 248 250 254 285 286 288 292 325 326 328 332 368 369 371 375 415 416 417 422 464 465 467 471 V) Lo PR 129 131 134 139 137 138 141 147 143 145 148 153 149 150 153 159 154 156 159 164 161 163 166 171 Gl X IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) I High and low pressures are measured at the liquid and suction service valves. kW=Total system power m N OUTDOOR AMBIENT TEMPERATURE C) 659F 752F 852F 959F 1052F 11521' fx-+ ENTERING INDOOR WET BULB TEMPERATURE -M wgrm 67 71 59 63 67 71 59 1 63 1 67 71 59 63 67 71 S9 63 1 67 71 MBh 30.6 31.7 34.7 29.8 30.9 33.9 - 29.1 30.2 33.1 - 28.4 29.5 32.3 - 27.0 28.0 30.7 - 25.0 25.9 28.4 - S/T 0.71 0.59 0.41 0.74 0.62 0.43 0.76 0.63 0.44 0.78 0.65 0.45 0.81 0.68 0.47 0.82 0.68 0.47 AT 19 16 13 19 17 13 19 17 13 19 17 13 19 17 13 18 15 12 1050 kW 2.23 2.27 2.34 2.39 2.44 2.51 2.53 2.58 2.66 2.65 2.70 2.79 2.75 2.81 2.90 2.84 2.90 2.99 Amps 8.1 8.3 8.5 8.7 8.9 9.2 9.5 9.7 10.0 10.1 10.4 10.7 10.8 11.1 11.4 11.5 11.7 12.1 W PR 219 236 249 246 265 280 280 301 318 319 343 362 359 386 407 396 426 450 Lo PR 103 109 120 109 116 126 113 120 131 119 126 138 124 132 144 129 137 149 MBh, 33.1 34.3 37.6 32.3 33.5 36.7 31.6 32.7 35.8 30.8 31.9 35.0 29.3 30.3 33.2 27.1 28.1 30.8 S/T 0.74 0.62 0.43 0.76 0.64 0.44 0.78 0.65 0.45 0.81 0.68 0.47 0.84 0.70 0.49 0.85 0.71 0.49 AT 19 16 12 19 16 12 19 16 12 19 17 13 19 16 12 18 15 12 70 1200 kW 2.28 2.33 2.39 2.44 2.49 2.57 2.59 2.64 2.72 2.71 2.77 2.8S 2.82 2.88 2.97 2.91 2.97 3.07 Amps 8.3 8.5 8.8 9.0 9.2 9.5 9.8 10.0 10.3 10.4 10.7 11.1 11.1 11.4 11.8 11.8 12.1 12.5 HiPR 226 243 257 254 273 288 288 310 328 329 354 373 370 398 420 408 440 464 Lo PR 106 113 123 112 119 130 116 124 135 122 130 142 128 136 149 133 141 154 MBh 34.1 35.3 38.7 33.3 34.5 37.8 32.5 33.7 36.9 31.7 32.9 36.0 30.1 31.2 34.2 27.9 28.9 31.7 m S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 0.74 0.51 b AT 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 17 15 11 a 1350 kW 2.30 2.34 2.41 2.46 2.51 2.59 2.61 2.66 2.74 2.73 2.79 2.88 2.84 2.90 2.99 2.94 3.00 3.09 O Go Amps 8.4 8.6 8.9 9.1 9.3 9.6 9.9 10.1 10.4 10.5 10.8 11.2 11.2 11.5 11.9 11.9 12.2 12.6 m v 0 Hi PR 228 246 259 - 256 276 291 - 291 314 331 - 332 357 377 - 373 402 424 - 413 444 469 - O Lo PR 107 114 124 113 120 131 118 125 137 124 131 144 130 138 150 134 143 156 :3 r- 3 Z oa MBh 31.1 32.0 34.6 37.2 30.4 31.3 33.8 36.3 29.6 30.5 33.0 35.4 28.9 29.8 32.2 34.6 27.5 28.3 30.6 32.8 25.4 26.2 28.4 30.4 Gl o S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 O 3 AT 22 20 17 11 22 21 17 12 22 21 17 12 22 21 17 12 22 20 17 12 21 19 16 11 1050 kW 2.25 2.29 2.36 2.43 2.41 2.45 2.53 2.60 2.55 2.60 2.68 2.76 2.67 2.73 2.81 2.90 2.78 2.83 2.92 3.01 2.87 2.93 3.02 3.11 D Amps 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.7 9.6 9.8 10.1 10.5 10.2 10.5 10.9 11.3 10.9 11.2 11.6 12.0 11.6 11.9 12.3 12.7 Hi PR 222 238 252 263 249 267 282 295 283 304 321 335 322 346 366 382 362 390 412 429 400 431 455 474 G) Lo PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161 k MBh 33.7 34.7 37.5 40.3 32.9 33.9 36.6 39.3 32.1 33.1 35.8 38.4 31.3 32.2 34.9 37.5 29.8 30.6 33.2 35.6 27.6 28.4 30.7 33.0 (31 ~' S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.65 0.42 0.96 0.86 0.65 0.42 p AT 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 11 22 20 16 11 20 19 15 11 N 75 1200 kW 2.30 2.34 2.41 2.48 2.46 2.S1 2.59 2.67 2.61 2.66 2.74 2.83 2.73 2.79 2.88 2.97 2.84 2.90 2.99 3.09 2.94 3.00 3.09 3.19 W Amps 8.4 8.6 8.9 9.2 9.1 9.3 9.6 10.0 9.9 10.1 10.4 10.8 10.5 10.8 11.2 11.6 11.2 11.5 11.9 12.3 11.9 12.2 12.6 13.1 Hi PR 228 246 260 271 256 276 291 304 291 314 331 345 332 357 377 393 373 402 424 443 413 444 469 489 Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166 MBh 34.7 35.7 38.6 41.5 33.9 34.9 37.7 40.5 33.1 34.0 36.9 39.6 32.3 33.2 36.0 38.6 30.6 31.6 34.2 36.7 28.4 29.2 31.6 34.0 S/T 0.88 0.79 0.60 0.38 0.91 0.81 0.62 0.40 0.93 0.84 0.63 0.41 0.96 0.86 0.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44 AT 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 19 18 15 10 � 1350 kW 2.32 2.36 2.43 2.50 2.48 2.53 2.61 2.69 2.63 2.68 2.76 2.85 2.76 2.81 2.90 2.99 2.86 2.93 3.02 3.11 2.96 3.02 3.12 3.22 O Amps 8.5 8.7 8.9 9.3 9.1 9.4 9.7 10.0 9.9 10.2 10.5 10.9 10.6 10.9 11.3 11.7 11.3 11.6 12.0 12.5 12.0 12.3 12.7 13.2 Hi PR 231 248 262 273 259 279 294 307 294 317 334 349 335 361 381 397 377 406 429 447 417 448 474 494 a) Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) x High and low pressures are measured at the liquid and suction service valves. kW=Total system power V W OUTDOOR AMBIENT TEMPERATURE X 652F 752F 852F 952F 1052F 1152F n ENTERING INDOOR WET BULB TEMPERATURE O IDIB AIRFLOW 59 63 1 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 1 71 59 1 63 1 67 1 71 m MBh 31.6 32.3 34.5 36.9 30.9 31.6 33.7 36.1 30.2 30.8 32.9 35.2 29.4 30.1 32.1 34.3 28.0 28.6 30.5 32.6 25.9 26.5 28.3 30.2 rz) 5/T 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.01 0.95 0.77 0.58 1.02 0.95 0.78 0.58 p AT 25 24 20 16 25 24 21 17 25 24 21 17 25 24 21. 17 25 24 21 16 23 22 19 15 0 1050 kW 2.26 2.31 2.38 2.45 2.42 2.47 2.55 2.62 2.57 2.62 2.70 2.78 2.69 2.75 2.83 2.92 2.80 2.86 2.94 3.04 2.89 2.95 3.04 3.14 Z Amps 8.2 8.4 8.7 9.0 8.9 9.1 9.4 9.8 9.7 9.9 10.2 10.6 10.3 10.6 11.0 11.4 .11.0 11.3 11.7 12.1 11.7 12.0 12.4 12.8 G) Hi PR 224 241 254 265 251 270 285 298 286 307 324 338 325 350 370 385 366 394 416 434 . 404 435 459 479 Lo PR 1 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 n MBh 34.3 35.0 37.4 40.0 33.5 34.2 36.5 39.1 32.7 33.4 35.7 38.1 31.9 32.6 34.8 37.2 30.3 30.9 33.1 35.3 28.1 28.7 30.6 32.7 S/T 0.92 0.86 0.70 0.52 0.95- 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 0.99 0.81 0.60 AT 24 23 20 16 24 23 20 16 24 23 20 16 24 24 21 16 23' 23 20 16 21 22 19 15 k 80 1200 kW 2.32 2.36 2.43 2.50 2.48 2.53 2.61 2.69 2.63 2.68 2.76 2.85 2.76 2.81 2.90 2.99 2.87 2.93 3.02 3.11 2.96 3.02 3.12 3.22 Amps 8.5 8.7 8.9 9.3 9.1 9.4 9.7 10.0 9.9 10.2 10.5 10.9 10.6 10.9 11.3 11.7 11.3 11.6 12.0 12.5 12.0 12.3 12.7 13.2 � Hi PR 231 248 262 273 259 279 294 307 294 317 335 349 335 361 381 397 377 406 429 447 417 448 474 494 Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 MBh 35.3 36.1 38.5 41.2 34.5 35.2 37.6 40.2 33.7 34.4 36.7 39.3 32.8 33.5 35.8 38.3 31.2 31.9 34.1 36.4 28.9 29.5 31.5 33.7 lu S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 1.00 0.84 0.63 644 AT 23 22 19 15 23 22 20 16 23 23 20 16 22 23 20 16 21 22 19 16 20 20 18 15 1350 kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.70 2.78 2.87 2.78 2.84 2.92 3.02 2.89 2.95 3.04 3.14 2.98 3.05 3.14 3.24 n o Amps 8.5 8.7 9.0 9.4 9.2 9.5 9.8 10.1 10.0 10.3 10.6 11.0 10.7 11.0 11.4 11.8 11.4 11.7 12.1 12.6 12.1 12.4 12.8 13.3 C)- Hi PR 233 251 265 276 261 281 297 310 297 320 338 352 339 364 385 401 381 410 433 452 421 453 478 499 v Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169 00 O 69, MBh 32.2 32.8 34.4 36.7 31.4 32.0 33.6 35.8 30.7 31.3 32.8 34.9 29.9 30.5 32.0 34.1 28.4 29.0 30.4 32.4 26.3 26.9 28.1 30.0 o S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 O AT 26 26 24 21 27 26 25 21 27 26 25 21 26 26 25 22 25 25 25 21 23 24 23 20 + 1050 kW 2.28 2.33 2.39 2.46 2.44 2.49 2.57 2.64 2.59 2.64 2.72 2.80 2.71 2.77 2.85 2.94 2.82 2.88 2.97 3.06 2.91 2.97 3.07 3.16 k Amps 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.9 9.8 10.0 10.3 10.7 10.4 10.7 11.1 11.5 11.1 11.4 11.8 12.2 11.8 12.1 12.5 13.0 C Hi PR 226 243 257 268 254 273 288 301 288 310 328 342 328 353 373 389 370 398 420 438 408 439 464 484 0 Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164 z MBh 34.9 35.5 37.2 39.7 34.1 34.7 36.4 38.8 33.2 33.9 35.5 37.9 32.4 33.1 34.6 36.9 30.8 31.4 32.9 35.1 28.5 29.1 30.5 32.5 y 5/T 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.96 0.78 AT 26 25 24 21 26 26 24 21 25 26 24 21 25 25 24 21 24 24 24 21 22 22 22 19 85 1200 kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.70 2,78 2.87 2.78 2.84 2.92 3.02 2.89 2.95 3.04 3,14 2.98 3.05 3.14 3.24 Amps 8.5 8.7 9.0 9.4 9.2 9.5 9.8 10.1 10.0 10.3 10.6 11.0 10.7 11.0 11.4 11.8 11.4 11.7 12.1 12.6 12.1 12.4 12.8 13.3 Hi PR 233 251 265 276 261 281 297 310 297 320 338 352 339 364 385 401 381 410 433 452 421 453 478 499 Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169 MBh 35.9 36.6 38.3 40.9 35.1 35.8 37.4 40.0 34.2 34.9 36.6 39.0 33.4 34.1 35.7 38.0 31.7 32.4 33.9 36.1 29.4 30.0 31.4 33.5 S/T 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82 AT 24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 22 22 23 20 20 20 21 19 1350 kW 2.35 2.40 2.47 2.54 2.52 2.57 2.65 2.73 2.67 2.72 2.81 2.89 2.80 2.86 2.95 3.04 2.91 2.97 3.07 3.16 3.01 3.07 3.17 3.27 Amps 8.6 8.8 9.1 9.5 9.3 9.5 9.9 10.2 10.1 10.4 10.7 11.1 10.8 11.1 11.5 11.9 11.5 11.8 12.2 12.7 12.2 12.5 13.0 13.5 Hi PR 235 253 267 279 264 284 300 313 300 323 341 356 342 368 389 405 385 414 437 456 425 457 483 504 Y Lo PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 158 133 142 155 165 138 147 160 171 G1 Ln IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) X M High and low pressures are measured at the liquid and suction service valves, kW=Total system power LP OUTDOOR AMBIENT TEMPERATURE N I 659F 752F 85eF 952F 1052F 1152F tX- ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 59 63 67 71. 59 63 67 71 59 63 67 71 59 63 1 67 71 59 63 67 71 59 63 1 67 71 MBh 36.6 37.1 38.2 --- 36.3 36.8 37.9 --- 35.3 35.9 37.0 --- 33.7 34.2 35.3 --- 31.7 32.2 33.3 --- 29.8 30.4 31.5 --- S/T 0.60 0.53 0.39 --- 0.61 0.53 0.40 --- 0.63 0.56 0.42 --- 0.65 0.58 0.44 --- 0.67 0.60 0.46 --- 1.00 0.65 0.51 --- OT 21 19 15 --- 21 19 15 --- 21 19 16 --- 21 19 15 --- 21 19 15 --- 22 20 16 --- 1050 kW 2.10 2.10 2.10 --- 2.34 2.34 2.34 --- 2.61 2.61 2.60 --- 2.90 2.89 2.89 --- 3.22 3.21 3.21 --- 3.59 3.59 3.59 --- Amps 7.6 7.6 7.6 --- 8.7 8.7 8.7 --- 9.9 9.9 9.9 --- 11.2 11.2 11.2 --- 12.7 12.7 12.7 --- 14.4 14.4 14.4 --- Hi PR 245 246 248 --- 283 285 286 --- 324 325 327 --- 367 369 370 --- 414 416 417 --- 465 466 467 --- Lo PR 118 120 123 --- 126 127 130 --- 132 133 136 -- 137 139 142 --- 143 144 147 --- 149 151 154 --- MBh 37.1 37.6 38.7 --- 36.8 37.3 38.4 --- 35.8 36.3 37.4 --- 34.2 34.7 35.8 --- 32.2 32.7 33.8 --- 30.3 30.8 31.9 --- S/T 0.66 0.59 0.45 --- 0.67 0.59 0.46 --- 0.69 0.62 0.48 --- 0.71 0.64 0.50 --- 1.00 0.66 0.52 --- 1.00 0.71 O.S7 AT 20 18 14 --- 20 18 14 --- 20 18 14 --- 20 18 14 --- 19 17 14 --- 21 19 15 70 1200 kW 2.12 2.11 2.11 --- 2.35 2.35 2.35 --- 2.62 2.62 2.61 --- 2.91 2.91 2.90 --- 3.23 3.23 3.22 --- 3.61 3.60 3.60 --- Amps 7.7 7.7 7.7 --- 8.8 8.8 8.7 --- 10.0 10.0 10.0 --- 11.3 11.3 11.3 --- 12.8 12.8 12.7 --- 14.5 14.5 14.5 -- Hi PR 247 248 250 --- 286 287 288 --- 326 327 329 --- 370 371 372 --- 417 418 419 --- 467 468 469 --- k Lo PR 120 122 125 --- 127 129 132 --- 134 135 138 --- 139 140 143 --- 144 146 149 --- 151 152 155 --- M13h 37.7 38.2 39.3 --- 37.4 37.9 39.0 --- 36.4 36.9 38.0 --- 34.8 35.3 36.4 --- 32.7 33.3 34.4 --- 30.9 31.4 32.5 � S/T 0.70 0.62 0.48 --- 0.70 0.63 0.49 --- 0.73 0.65 0.52 --- 0.75 0.67 0.54 --- 1.00 0.69 0.56 --- 1.00 0.74 0.61 --- M AT 19 17 13 --- 19 17 13 --- 19 17 13 --- 19 17 13 --- 18 16 13 --- 20 18 14 --- O 1350 kW 2.13 2.12 2.12 --- 2.36 2.36 2.36 --- 2.63 2.63 2.62 --- 2.92 2.92 2.91 --- 3.24 3.24 3.23 --- 3.62 3.61 3.61 --- 0 o Amps 7.7 7.7 7.7 --- 8.8 8.8 8.8 --- 10.0 10.0 10.0 --- 11.4 11.3 11.3 --- 12.8 12.8 12.8 --- 14.5 14.5 14.5 --- p O Hi PR 249 250 252 --- 288 289 290 --- 328 329 331 --- 372 373 374 --- 419 420 421 --- 469 470 472 Lo PR 122 124 127 --- 129 131 134 --- 136 137 140 --- 141 142 145 --- 146 148 151 --- 153 154 157 --- Gl 3 66, MBh 36.6 37.2 38.3 39.9 36.3 36.8 37.9 39.6 35.4 35.9 37.0 38.6 33.7 34.2 35.3 37.0 31.7 32.2 33.3 35.0 29.9 30.4 31.5 33.2 n o S/T 0.73 0.65 0.52 0.38 0.74 0.66 0.53 0.38 0.76 0.69 0.55 0.41 1.00 0.70 0.57 0.43 1.00 0.73 0.59 0.45 1.00 0.78 0.64 0.50 3 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 20 17 1050 kW 2.10 2.10 2.10 2.11 2.34 2.34 2.33 2.35 2.61 2.60 2.60 2.62 2.89 2.89 2.89 2.91 3.22 3.21 3.21 3.23 3.59 3.59 3.59 3.60 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 Hi PR 245 246 248 252 284 285 286 291 324 325 327 331 368 369 370 375 415 416 417 422 465 466 468 472 p� Lo PR 118 120 123 128 126 127 130 135 132 133 136 141 137 139 142 147 143 144 147 152 149 151 154 159 O MBh 37.1 37.6 38.7 40.4 36.8 37.3 38.4 40.1 35.8 36.4 37.5 39.1 34.2 34.7 35.8 37.5 32.2 32.7 33.8 35.5 30.4 30.9 32.0 33.6 Ij IVa S/T 0.79 0.71 0.58 0.44 0.80 0.72 0.59 0.44 1.00 0.75 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.79 0.65 0.51 1.00 0.84 0.70 0.56 � AT 24 22 18 15 24 22 18 15 24 22 19 15 24 22 18 15 24 22 18 14 25 23 19 16 A 75 1200 kW 2.11 2.11 2.11 2.13 2.35 2.35 2.35 2.36 2.62 2.62 2.61 2.63 2.91 2.90 2.90 2.92 3.23 3.23 3.22 3.24 3.60 3.60 3.60 3.62 O� Amps 7.7 7.7 7.6 7.7 8.8 8.8 8.7 8.8 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 12.8 12.8 12.7 12.8 14.5 14.5 14.5 14.5 Hi PR 247 248 250 254 286 287 289 293 326 327 329 333 370 371 373 377 417 418 420 424 467 468 470 474 Lo PR 120 122 125 130 127 129 132 137 134 135 138 143 139 140 144 149 144 146 149 154 151 152 155 160 MBh 37.7 38.2 39.3 41.0 37.4 37.9 39.0 40.7 36.4 36.9 38.0 39.7 34.8 35.3 36.4 38.1 32.8 33.3 34.4 36.0 30.9 31.4 32.5 34.2 1:; S/T 0.82 0.75 0.61 0.47 0.83 0.75 0.62 0.48 1.00 0.78 0.64 0.50 1.00 0.80 0.66 O.S2 1.00 0.82 0.69 0.54 1.00 0.87 0.74 0.59 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 23 21 17 13 24 22 18 15 00 1350 kW 2.12 2.12 2.12 2.14 2.36 2.36 2.36 2.38 2.63 2.63 2.62 2.64 2.92 2.91 2.91 2.93 3.24 3.24 3.23 3.25 3.61 3.61 3.61 3.63 Ol O Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 Hi PR 249 250 252 256 288 289 291 295 328 329 331 335 372 373 375 379 419 420 422 426 469 470 472 476 1::1 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 150 146 148 151 156 153 154 157 162 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) LD High and low pressures are measured at the liquid and suction service valves, kW=Total system power C O OUTDOOR AMBIENT TEMPERATURE X 659F 759E T 859F 959F 1059F 1159F n ENTERING INDOOR WET BULB TEMPERATURE Z D: 0 MBh 36.8 37.4 38.4 40.1 36.5 37.0 38.1 39.8 35.6 36.1 37.2 38.8 33.9 34.4 35.5 37.2 31.9 32.4 33.5 35.2 30.1 30.6 31.7 33.3 r S/T 0.85 0.78 0.64 0.50 1.00 0.79 0.65 0.51 1.00 0.81 0.68 0.53 1.00 0.83 0.69 0.55 1.00 .0.85 0.72 0.57 1.00 1.00 0.77 0.63 p AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 24 20 30 28 25 21 1050 kW 2.10 2.10 2.10 2.12 2.34 2.34 2.34 2.35 2.61 2.61 2.60 2.62 2.90 2.89 2.89 2.91 3.22 3.21 3.21 3.23 3.59 3.59 3.59 3.61 Z Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 G) Hi PR 245 247 248 253 284 285 287 291 325 326 327 332 368 369 371 375 415 416 418 422 465 466 468 472 Lo PR 119 120 123 128 126 128 131 136 132 134 137 142 138 139 142 147 143 145 148 153 150 151 154 159 n MBh 37.3 37.8 38.9 40.6 37.0 37.5 38.6 40.3 36.0 36.6 37.6 39.3 34.4 34.9 36.0 37.7 32.4 32.9 34.0 35.7 30.5 31.1 32.2 33.8 S/T 0.91 0.84 0.70 0.56 1.00 0.84 0.71 0.57 1.00 0.87 0.73 0.59 1.00 0.89 0.75 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.83 0.69 AT 28 26 23 19 28 26 23 19 28 27 23 19 28 26 23 19 28 26 22 19 29 27 24 20 Ln 80 1200 kW 2.12 2.11 2.11 2.13 2.35 2.35 2.35 2.37 2.62 2.62 2.61 2.63 2.91 2.91 2.90 2.92 3.23 3.23 3.22 3.24 3.61 3.60 3.60 3.62 64 Amps 7.7 7.7 7.7 7.7 8.8 8.8 8.7 8.8 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 12.8 12.8 12.7 12.8 14.5 14.5 14.5 14.6 (3) Hi PR 248 249 250 255 286 287 289 293 327 328 329 334 370 371 373 377 417 418 420 424 467 468 470 474 O Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 154 151 153 156 161 MBh 37.9 38.4 39.5 41.2 37.6 38.1 39.2 40.9 36.6 37.1 38.2 39.9 35.0 35.5 36.6 38.2 33.0 33.5 34.6 36.2 31.1 31.6 32.7 34.4 S/T 1.00 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.90 0.77 0.63 1.00 0.92 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72 W g AT 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 21 18 28 26 23 19 a) 1350 kW 2.13 2.12 2.12 2.14 2.36 2.36 2.36 2.38 2.63 2.63 2.62 2.64 2.92 2.92 2.91 2.93 3.24 3.24 3.23 3.25 3.62 3.61 3.61 3.63 o Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 a Hi PR 250 251 252 257 288 289 291 295 329 330 331 336 372 373 375 379 419 420 422 426 469 470 472 476 n v Lo PR 1 123 124 127 132 1 130 131 134 139 1 136 138 141 146 1 141 143 146 151 147 148 151 156 153 155 158 163 7 3 00 6TMBh 37.5 38.0 39.1 40.7 37.1 37.6 38.7 40.4 36.2 36.7 37.8 39.5 34.5 35.0 36.1 37.8 32.5 33.0 34.1 35.8 30.7 31.2 32.3 34.0 Ql o S/T 1.00 0.88 0.74 0.60 1.00 0.89 0.75 0.61 1.00 1.00 0.78 0.63 1.00 1.00 0.80 0.65 1.00 1.00 0.82 0.68 1.00 1.00 0.87 0.73 O 3 AT 33 31 28 24 33 31 28 24 33 32 28 24 33 31 28 24 33 31 27 24 34 32 29 25 Ol 1050 kW 2.11 2.11 2.10 2.12 2.35 2.34 2.34 2.36 2.61 2.61 2.61 2.62 2.90 2.90 2.89 2.91 3.22 3.22 3.22 3.23 3.60 3.60 3.59 3.61 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.3 11.3 11.2 11.3 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.5 i Hi PR 247 248 249 254 285 286 288 292 326 327 329 333 369 370 372 376 416 417 419 423 466 468 469 473 k Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146149 154 151 153 156 161 MBh 37.9 38.5 39.5 41.2 37.6 38.1 39.2 40.9 36.7 37.2 38.3 39.9 35.0 35.5 36.6 38.3 33.0 33.5 34.6 36.3 31.2 31.7 32.8 34.4 r) S/T 1.00 0.94 0.80 0.66 1.00 0.95 0.81 0.67 1.00 1.00 0.84 0.69 1.00 1.00 0.85 0.71 1.00 1.00 0.88 0.73 1.00 1.00 0.93 0.79 Z AT 32 30 27 23 32 30 26 23 32 30 27 23 32 30 26 23 32 30 26 22 33 31 27 24 85 1200 kW 2.12 2.12 2.11 2.13 2.36 2.36 2.35 2.37 2.62 2.62 2.62 2.64 2.91 2.91 2.91 2.92 3.23 3.23 3.23 3.25 3.61 3.61 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.8 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.8 14.5 14.5 14.5 14.6 Hi PR 249 250 251 256 287 288 290 294 328 329 331 335 371 372 374 378 418 419 421 425 469 470 471 476 Lo PR 122 124 127 132 130 131 134 139 136 137 140 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 38.5 39.0 40.1 41.8 38.2 38.7 39.8 41.5 37.2 37.7 38.8 40.5 35.6 36.1 37.2 38.9 33.6 34.1 35.2 36.9 31,7 32.3 33.3 35.0 S/T 1.00 0.97 0.84 0.70 1.00 0.98 0.84 0.70 1.00 1.00 0.87 0.73 1.00 1.00 0.89 0.75 1.00 1.00 0.91 0.77 1.00 1.00 1.00 0.82 AT 31 29 26 22 31 29 25 22 31 29 26 22 31 29 25 22 31 29 25 21 32 30 26 23 1350 kW 2.13 2.13 2.12 2.14 2.37 2.37 2.36 2.38 2.63 2.63 2.63 2.65 2.92 2.92 2.92 2.93 3.24 3.24 3.24 3.26 3.62 3.62 3.61 3.63 Amps 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.1 10.0 10.0 10.1 11.4 11.4 11.3 11.4 12.8 12.8 12.8 12.9 14.6 14.6 14.5 14.6 Ln Hi PR 251 252 254 258 289 290 292 296 330 331 333 337 373 374 376 380 420 421 423 427 471 472 473 478 I^ Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 G) x IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) N High and low pressures are measured at the liquid and suction service valves. kW=Total system power OUTDOOR AMBIENT TEMPERATURE N 65°F 752F 859F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 1 59 63 1 67 71 59 63 67 71 59 63 1 67 71 1 59 1 63 67 71 59 63 67 71 59 63 67 71 MBh 36.9 38.2 41.9 - 36.0 37.3 40.9 - 35.2 36.4 39.9 - 34.3 35.6 39.0 - 32.6 33.8 37.0 - 30.2 31.3 34.3 - S/T 0.70 0.59 0.41 0.73 0.61 0.42 0.75 0.62 0.43 0.77 0.64 0.45 0.80 0.67 0.46 0.81 0.67 0.47 AT 19 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 1225 kW 2.70 2.76 2.83 2.89 2.95 3.03 3.06 3.12 3.21 3.20 3.27 3.37 3.33 3.39 3.50 3.43 3.50 3.61 Amps 9.9 10.1 10.4 10.7 10.9 11.3 11.6 11.8 12.2 12.3 12.6 13.1 13.1 13.4 13.9 13.9 14.2 14.7 HiPR 220 237 250 247 265 280 281 302 319 320 344 363 359 387 409 397 427 451 Lo PR 102 109 119 108 115 125 112 119 130 118 125 137 124 131 143 128 136 148 MBh 40.0 41.4 45.4 39.0 40.5 44.3 38.1 39.5 43.3 37.2 38.5 42.2 35.3 36.6 40.1 32.7 33.9 37.1 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 0.70 0.48 AT 19 17 13 19 17 13 19 17 13 19 17 13 19 17 13 18 16 12 70 1400 kW 2.76 2.82 2.90 2.96 3.02 3.10 3.13 3.19 3.29 3.28 3.34 3.45 3.40 3.48 3.58 3.51 3.59 3.70 Amps 10.1 10.4 10.7 10.9 11.2 11.6 11.9 12.2 12.6 12.7 13.0 13.4 13.5 13.8 14.3 14.3 14.6 15.1 HiPR 227 244 258 254 274 289 289 311 329 329 355 374 371 399 421 409 441 465 Lo PR 105 112 122 111 118 129 116 123 134 122 129 141 127 135 148 132 140 153 r MBh 41.2 42.7 46.7 40.2 41.7 45.7 39.2 40.7 44.6 38.3 39.7 43.5 36.4 37.7 41.3 33.7 34.9 38.3 n S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.73 0.50 0.88 0.73 0.51 AT 18 16 12 19 16 12 19 16 12 19 16 12 18 16 12 17 15 11 0 1575 kW 2.78 2.84 2.92 2.98 3.04 3.13 3.15 3.21 3.31 3.30 3.37 3.47 3.43 3.50 3.61 3.54 3.62 3.73 o Amps 10.2 10.5 10.8 11.0 11.3 11.7 12.0 12.3 12.7 12.8 13.1 13.6 13.6 14.0 14.4 14.4 14.8 15.3 On Q Hi PR 229 246 260 257 276 292 292 314 332 333 358 378 374 403 425 414 445 470 p 3 Lo PR 106 113 124 112 120 131 117 124 136 123 131 143 129 137 149 133 142 155 � Z 3 G) 66, MBh 37.5 38.6 41.8 44.9 36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9 35.9 38.9 41.7 33.1 34.1 36.9 39.6 30.7 31.6 34.2 36.7 I:j hS/T 0.80 0.71 0.54 D.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40 n AT 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 19 16 11 1225 kW 2.72 2.78 2.86 2.94 2.91 2.97 3.06 3.15 3.08 3.14 3.23 3.33 3.23 3.29 3.39 3.50 3.35 3.42 3.53 3.64 3.46 3.53 3.64 3.76 Amps 10.0 10.2 10.5 10.9 10.8 11.0 11.4 11.8 11.7 11.9 12.3 12.8 12.5 12.8 13.2 13.7 13.3 13.6 14.0 14.6 14.0 14.4 14.9 15.4 G) HiPR 222 239 252 263 249 268 283 295 283 305 322 336 323 347 367 383 363 391 413 430 401 432 456 476 >C Lo PR 103 110 120 128 109 116 127 135 113 121 132 140 119 127 138 147 125 133 145 154 129 137 150 160 O1 MBh 40.6 41.8 45.3 48.6 39.7 40.9 44.2 47.5 38.7 39.9 43.2 46.3 37.8 38.9 42.1 45.2 35.9 37.0 40.0 43.0 33.3 34.2 37.1 39.8 O S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.8S 0.64 0.41 L'i AT 22 20 17 12 22 21 17 12 22 21 17 12 23 21 17 12 22 20 17 12 21 19 16 11 75 1400 kW 2.78 2.84 2.92 3.01 2.98 3.04 3.13 3.22 3.15 3.21 3.31 3.41 3.30 3.37 3.47 3.58 3.43 3.50 3.61 3.72 3.54 3.62 3.73 3.85 A Amps 10.2 10.5 10.8 11.2 11.0 11.3 11.7 12.1 12.0 12.3 12.7 13.2 12.8 13.1 13.6 14.1 13.6 14.0 14.4 15.0 14.4 14.8 15.3 15.9 N HiPR 229 246 260 271 257 276 292 305 292 314 332 346 333 358 378 394 374 403 425 444 414 445 470 ' 490 Lo PR 1 106 113 124 132 112 120 131 139 117 124 136 145 123 131 143 152 129 137 149 159 133 142 155 165 n MBh 41.9 43.1 46.6 50.1 40.9 42.1 45.6 48.9 39.9 41.1 44.5 47.7 38.9 40.1 43.4 46.6 37.0 38.1 41.2 44.2 34.3 35.3 38.2 41.0 S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43 AT 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 00 1575 kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.25 3.17 3.24 3.34 3.44 3.33 3.40 3.50 3.61 3.46 3.53 3.64 3.75 3.57 3.65 3.76 3.88 � Amps 10.3 10.6 10.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 HiPR 231 249 263 274 259 279 295 308 295318 335 350 336 362 382 398 378 407 430 448 418 450 475 495 D Lo PR 1 107 114 125 133 114 121 132 140 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 + IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) x High and low pressures are measured at the liquid and suction service valves. kW=Total system power ti m n! OUTDOOR AMBIENT TEMPERATURE X 652F 752F 852F 952F 1052F. 1152F ENTERING INDOOR WET BULB TEMPERATURE b 1: AIRFLOWr ri MBh 38.2 39.0 41.7 44.5 37.3 38.1 40.7 - 43.5 36.4 37.2 39.7 42.5 35.5 36.3 38.8 41.4 33.7 34.5 36.8 39.4 31.2 31.9 34.1 36.5 S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 AT 25 24 21 17 25 24 21 17 25 24 21 17 26 25 21 17 25 24 21 17 24 23 20 16 O 1225 kW 2.74 2.80 2.88 2.96 2.93 2.99 3.08 3.17 3.10 3.17 3.26 3.36 3.25 3.32 3.42 3.52 3.38 3.45 3.55 3.66 3.49 3.56 3.67 3.79 Amps 10.0 10.3 10.6 11.0 10.8 11.1 11.5 11.9 11.8 12.1 12.5 12.9 12.6 12.9 13.3 13.8 13.4 13.7 14.2 14.7 14.2 14.5 15.0 15.6 G1 Hi PR 224 241 255 266 252 271 286 298 286 308 325 339 326 351 371 386 367 395 417 435 405 436 461 480 Lo PR 104 111 121 129 110 117 128 136 114 122 133 142 120 128 140 149 126 134 146 156 130 139 151 161 n MBh 41.4 42.3 45.2 48.3 40.4 41.3 44.1 47.1 39.4 40.3 43.1 46.0 38.5 39.3 42.0 44.9 36.5 37.3 39.9 42.7 33.9 34.6 37.0 39.5 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 ; 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 AT 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 17 22 22 19 15 80 1400 kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.25 3.18 3.24 3.34 3.44 3.33 3.40 3.50 3.61 3.46 3.53 3.64 3.75 3.57 3.65 3.76 3.88 Amps 10.3 10.6 10.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 (3) Hi PR 231 249 263 274 260 279 295 308 295 318 335 350 336 362 382'' 398 378 407 430 448 418 450 475 495 Lo PR 107 114 125 133 114 121 132 140 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 42.6 43.5 46.5 49.7 41.6 42.5 45.4 48.6 40.6 41.5 44.3 47.4 39.6 40.5 43.3 46.2 37.6 38.5 41.1 43.9 34.9 35.6 38.1 40.7 S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62 p AT 24 23 20 16 24 23 20 16 24 23 20 16 23 24 20 16 22 22 20 16 20 21 19 15 H 1575 kW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.47 3.35 3.42 3.53 3.64 3.49 3.56 3.67 3 78 3.60 3.67 3.79 3.91 Amps 10.4 10.7 11.0 11.4 11.2 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.4 13.8 14.3 13.9 14.2 14.7 15.2 14.7 15.1 15.6 16.2 0o0L Hi PR 234 251 265 277 262 282 298 311 298 321 339 353 340 365 386 402 382 411 434 453 422 454 480 500 n v Lo PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168 MBh 38.8 39.6 41.5 44.2 37.9 38.7 40.5 43.2 37.0 37.7 39.5 42.2 36.1 36.8 38.6' 41.2 34.3 35.0 36.6 39.1 31.8 32.4 33.9 36.2 Q) o S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74 z`1 AT 27 26 25 22 27 27 25 22 27 27 25 22 27 27 25 22 26 26 25 22 24 24 23 20 1225 kW 2.76 2.82 2.90 2.98 2.96 3.01 3.10 3.20 3.13 3.19 3.28 3.38 3.28 3.34 3.44 3.55 3.40 3.47 3.58 3.69 3.51 3.59 3.70 3.82 } Amps 10.1 10.4 10.7 11.1 10.9 11.2 11.6 12.0 11.9 12.2 12.6 13.0 12.7 13.0 13.4 13.9 13.5 13.8 14.3 14.8 14.3 14.6 15.1 15.7 k Hi PR 227 244 257 269 254 274 289 301 289 311 329 343 329 354 374 390 371 399 421 439 409 441 465 485 C Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 163 n MBh 42.1 42.9 44.9 47.9 41.1 41.9 43.9 46.8 40.1 40.9 42.8 45.7 39.1 39.9 41.8 44.6 37.2 37.9 39.7 42.4 34.4 35.1 36.8 39.2 O S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 AT 26 26 24 21 27 26 25 21 26 26 25 21 26 26 25 22 24 25 25 21 23 23 23 20 85 1400 kW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.47 3.35 3.42 3.53 3.64 3.49 3.56 3.67 3.78 3.60 3.67 3.79 3.91 Amps 10.4 10.7 11.0 11.4 11.2 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.4 13.8 14.3 13.9 14.2 14.7 15.2 14.7 15.1 15.6 16.2 Hi PR 234 251 265 277 262 282 298 311 298 321 339 353 340 365 386 402 382 411 434 453 422 454 480 500 Lo PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168 MBh 43.3 44.2 46.3 49.4 42.3 43.2 45.2 48.2 41.3 42.1 44.1 47.1 40.3 41.1 43.0 45.9 38.3 39.0 40.9 43.6 35.5 36.2 37.9 40.4 S/T 1.00 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81 AT 25 25 23 20 25 25 24 21 24 25 24 21 24 24 24 21 22 23 24 20 21 21 22 19 1575 kW 2.85 2.90 2.98 3.07 3.05 3.11 3.20 3.30 3.22 3.29 3.39 3.49 3.38 3.45 3.55 3.67 3.51 3.59 3.70 3.81 3.63 3.70 3.82 3.94 Amps 10.5 10.8 11.1 11.5 11.3 11.6 12.0 12.4 12.3 12.6 13.0 13.5 13.2 13.5 13.9 14.5 14.0 14.3 14.8 15.4 14.8 15.2 15.7 16.3 Hi PR 236 254 268 280 265 285 301 314 301 324 342 357 343 369 390 406 386 415 438 457 426 459 484 505 Ln Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 146 159 170 Gl L' IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) x rn High and low pressures are measured at the liquid and suction service valves. kW=Total system power LO OUTDOOR AMBIENT TEMPERATURE N 65°F 75°F 859F 952F 1052F 1159F ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW 59 63 67 71 59 63 67 71 59 63 1 67 71 59 1 63 67 71 59 63 67 71 59 63 67 71 MBh 42.6 44.2 48.4 - 41.6 43.2 47.3 - 40.7 42.1 46.2 - 39.7 41.1 45.0 - 37.7 39.1 42.8 - 34.9 36.2 39.6 - S/T 0.70 0.59 0.41 0.73 0.61 0.42 0.75 0.62 0.43 0.77 0.64 0.45 0.80 0.67 0.46 0.81 0.67 0.47 AT 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 16 12 1400 kW 2.95 3.01 3.09 3.16 3.22 3.32 3.34 3.41 3.51 3.50 3.57 3.68 3.64 3.71 3.83 3.76 3.84 3.95 Amps 10.8 11.0 11.4 11.7 11.9 12.3 12.7 13.0 13.4 13.5 13.9 14.3 14.4 14.7 15.2 15.3 15.6 16.2 HiPR 221 238 251 248 267 282 282 304 321 321 346 365 361 389 411 399 430 454 Lo PR 105 112 122 111 118 129 115 123 134 121 129 141 127 135 147 131 140 152 MBh 43.3 44.9 49.2 42.3 43.8 48.0 41.3 42.8 46.9 40.3 41.7 45.7 38.3 39.6 43.4 35.4 36.7 40.2 5/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 0.70 0.48 AT 19 17 13 20 17 13 20 17 13 20 17 13 19 17 13 18 16 12 70 1500 kW 2.99 3.05 3.13 3.20 3.26 3.36 3.38 3.45 3.56 3.55 3.62 3.73 3.69 3.76 3.88 3.81 3.89 4.01 Amps 11.0 11.2 11.6 11.8 12.1 12.5 12.9 13.2 13.6 13.7 14.1 14.5 14.6 15.0 15.5 15.5 15.9 16.4 HiPR 225 242 256 252 272 287 287 309 326 327 352 371 368 396 418 406 437 462 Lo PR 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 134 142 155 R1 MBh 44.8 46.4 50.9 43.8 45.4 49.7 42.7 44.3 48.5 41.7 43.2 47.3 39.6 41.0 45.0 36.7 38.0 41.6 n S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 0.74 0.51 Z AT 18 15 12 18 16 12 18 16 12 18 16 12 18 15 12 17 14 11 rz) 1800 kW 3.03 3.09 3.18 3.25 3.31 3.41 3.44 3.51 3.61 3.60 3.68 3.79 3.75 3.82 3.94 3.87 3.95 4.07 O o Amps 11.2 11.4 11.8 12.1 12.3 12.8 13.1 13.4 13.9 14.0 14.3 14.8 14.9 15.3 15.8 15.8 16.2 16.7 r a Hi PR 229 247 261 257 277 292 293 315 333 333 359 379 375 404 426 414 446 471 p a Lo PR 109 116 127 115 122 134 120 127 139 126 134 146 132 140 153 136 145 158 � Z 3 G) oa MBh 43.4 44.6 48.3 51.9 42.4 43.6 47.2 50.7 41.3 42.6 46.1 49.5 40.3 41.5 45.0 48.2 38.3 39.5 42.7 45.8 35.5 36.5 39.6 42.5 Q 0 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40 y AT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 n 1400 kW 2.97 3.03 3.12 3.21 3.18 3.25 3.34 3.44 3.37 3.43 3.54 3.65 3.53 3.60 3.71 3.83 3.67 3.74 3.86 3.98 3.79 3.87 3.99 4.11 Amps 10.9 11.2 11.5 11.9 11.8 12.0 12.4 12.9 12.8 13.1 13.5 14.0 13.7 14.0 14.5 15.0 14.5 14.9 15.4 16.0 15.4 15.8 16.3 16.9 C) Hi PR 223 240 254 265 251 270 285 297 285 307 324 338 325 349 369 385 365 393 415 433 403 434 458 478 Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164 Q) MBh 44.0 45.3 49.1 52.7 43.0 44.3 47.9 51.4 42.0 43.2 46.8 50.2 41.0 42.2 45.6 49.0 38.9 40.1 43.4 46.5 36.0 37.1 40.2 43.1 O S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 (�6 AT 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11 75 1500 kW 3.01 3.07 3.16 3.25 3.22 3.29 3.38 3.49 3.41 3.48 3.59 3.70 3.58 3.65 3.76 3.88 3.72 3.79 3.91 4.04 3.84 3.92 4.04 4.17CO �A Amps 11.1 11.3 11.7 12.1 12.0 12.2 12.6 13.1 13.0 13.3 13.7 14.3 13.9 14.2 14.7 15.2 14.8 15.1 15.6 16.2 15.6 16.0 16.6 17.2 HiPR 227 244 258 269 255 274 290 302 290 312 329 344 330 355 375 391 371 400 422 440 410 442 466 486 Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 144 157 167 MBh 45.6 46.9 50.8 54.5 44.5 45.8 49.6 53.2 43.4 44.7 48.4 52.0 42.4 43.6 47.2 50.7 40.3 41.5 44.9 48.2 37.3 38.4 41.6 44.6 S/T 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.93 0.84 0.63 0.41 0.96 0.86 0.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44 AT 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 � 1800 kW 3.05 3.11 3.20 3.30 3.27 3.34 3.44 3.54 3.46 3.53 3.64 3.75 3.63 3.71 3.82 3.94 3.78 3.85 3.97 4.10 3.90 3.98 4.11 4.24 Amps 11.3 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.2 13.5 14.0 14.5 14.1 14.5 15.0 15.5 15.0 15.4 15.9 16.5 15.9 16.3 16.9 17.5 Hi PR 232 249 263 275 260 280 295 308 296 318 336 350 337 362 383 399 379 408 431 449 419 451 476 496 O Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) x LU High and low pressures are measured at the liquid and suction service valves. kW=Total system power .Np OUTDOOR AMBIENT TEMPERATURE rr 652F 752F 859F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE Z D: AIRFLOW 59 63 67 71 59 63 67 71 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 710 rri MBh 44.1 45.1 48.2 51.5 43.1 44.0 47.1 50.3 42.1 43.0 45.9 49.1 41.1 41.9 44.8 47.9 39.0 39.9 42.6 45.5 36.1 36.9 39.4 42.2 S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57 AT 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 26 24 21 17 24 23 20 16 O 1400 kW 2.99 3.05 3.14 3.23 3.21 3.27 3.37 3.47 3.39 3.46 3.57 3.68 3.56 3.63 3.74 3.86 3.70 3.77 3.89 4.01 3.82 3.90 4.02 4.15 Z Amps 11.0 11.3 11.6 12.0 11.9 12.2 12.6 13.0 12.9 13.2 13.6 14.2 13.8 14.1 14.6 15.1 14.7 15.0 15.5 16.1 1S.5 15.9 16.5 17.1 O Hi PR 226 243 256 267 253 272 288 300 288 310 327 341 328 353 373 389 369 397 419 437 408 439 463 483 O Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 1S0 160 134 143 156 166 n MBh 44.8 45.8 48.9 52.3 43.8 44.7 47.8 51.1 42.7 43.7 46.6 49.9 41.7 42.6 45.5 48.6 39.6 40.5 43.2 46.2 36.7 37.5 40.0 42.8 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 LOD 0.93 0.76 ' 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 AT 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 17 22 22 20 16Ln 80 1500 kW 3.03 3.09 3.18 3.28 3.25 3.31 3.41 3.51 3.44 3.51 3.61 3.73 3.60 3.68 3.79 3.91 3.75 3.82 3.94 4.07 3.87 3.95 4.07 4.20 Amps 11.2 11.4 11.8 12.2 12.1 12.4 12.8 13.2 13.1 13.4 13.9 14.4 14.0 14.3 14.8 15.4 14.9 15.3 15.8 16.4 15.8 16.2 16.7 17.4 001 _ Hi PR 229 247 261 272 257 277 293 305 293 315 333 347 334 359 379 395 375 404 426 445 415 446 471 491 Lo PR 109 116 127 135 115 123 134 142 .120 127 139 148 126 134 , 146 155 132 140 153 163 136 145 158 169 MBh 46.4 47.4 50.6 54.1 45.3 46.3 49.4 52.9 44.2 45.2 48.3 51.6 43.1 44.1 47.1 50.3 41.0 41.9 44.7 47.8 38.0 38.8 41.4 44.3 S/T 0.96 0.90 0.74 0.S5 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 1.00 0.85 0.63 AT 23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 16 21 21 19 15 19 20 18 14 � 1800 kW 3.08 3.14 3.23 3.33 3.30 3.36 3.46 3.57 3.49 3.56 3.67 3.78 3.66 3.74 3.85 3.97 3.81 3.88 4.01 4.13 3.93 4.01 4.14 4.27 Amps 11.4 11.6 12.0 12.5 12.3 12.6 13.0 13.5 13.3 13.7 14.1 14.7 14.3 14.6 15.1 15.7 15.2 15.5 16.1 16.7 16.1 16.5 17.0 17.7 n 0 0 Hi PR 234 252 266 277 263 283 298 311 299 321 339 354 340 366 387 403 383 412 435 454 423 455 481 501 Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172 66, MBh 44.9 45.8 47.9 51.1 43.9 44.7 46.8 50.0 42.8 43.6 45.7 48.8 41.8 42.6 44.6 47.6 39.7 40.4 42.4 45.2 36.8 37.5 39.2 41.9 N o S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74 3 AT 27 27 25 22 27 27 25 22 27 27 25 22 27 27 26 22 26 27 25 22 24 25 24 20 1400 kW 3.02 3.08 3.16 3.26 3.23 3.29 3.39 3.50 3.42 3.49 3.59 3.70 3.58 3.66 3.77 3.89 3.73 3.80 3.92 4.05 3.85 3.93 4.05 4.18 + Amps 11.1 11.4 11.7 12.2 12.0 12.3 12.7 13.1 13.0 13.3 13.8 14.3 13.9 14.2 14.7 1S.3 14.8 1S.2 15.7 16.3 15.7 16.1 16.6 17.2 k Hi PR 228 245 259 270 256 275 290 303 291 313 330 345 331 356 376 392 373 401 423 442 412 443 468 488 <1- Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 n MBh 45.6 46.5 48.7 51.9 44.5 45.4 47.5 50.7 43.5 44.3 46.4 49.5 42.4 43.2 45.3 48.3 40.3 41.1 43.0 45.9 37.3 38.0 39.8 42.5 O S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 �I AT 27 26 25 21 27 26 25 22 27 26 25 22 26 26 25 22 25 25 25 22 23 23 23 20 85 1500 kW 3.05 3.11 3.21 3.30 3.27 3.34 3.44 3.54 3.46 3.53 3.64 3.75 3.63 3.71 3.82 3.94 3.78 3.85 3.97 4.10 3.90 3.98 4.11 4.24 Amps 11.3 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.2 13.5 14.0 14.5 14.1 14.5 15.0 15.5 15.0 15.4 15.9 16.5 15.9 16.3 16.9 17.5 Hi PR 232 249 263 275 260 280 296 308 296 318 336 351 337 363 383 399 379 408 431 449 419 451 476 496 Lo PR 110 117 128 136 116 .124 135 144 121 129 140 150 127 135 147 157 133 142 155 165 138 146 160 170 MBh 47.2 48.1 50.4 53.7 46.1 47.0 49.2 52.5 45.0 45.9 48.0 51.2 43.9 44.7 46.9 50.0 41.7 42.5 44.5 47.5 38.6 39.4 41.2 44.0 S/T 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82 AT 24 24 23 20 24 24 23 20 23 23 23 20 22 23 23 20 21 22 23 20 20 20 21 18 1800 kW 3.10 3.16 3.25 3.35 3.32 3.39 3.49 3.60 3.52 3.59 3.70 3.81 3.69 3.77 3.88 4.00 3.83 3.92 4.04 4.17 3.96 4.05 4.17 4.31 Amps 11.5 11.7 12.1 12.6 12.4 12.7 13.1 13.6 13.5 13.8 14.2 14.8 14.4 14.7 15.2 15.8 15.3 15.7 16.2 16.8 16.2 16.6 17.2 17.9 Hi PR 236 254 269 280 265 285 301 314 302 325 343 358 344 370 390 407 387 416 439 458 427 460 485 506 Ln Lo PR 112 119 130 139 119 126 138 147 123 131 143 152 130 138 150 160 136 144 158 168 140 149 163 174 Gl X IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) rn High and low pressures are measured at the liquid and suction service valves. kW=Total system power Lnn OUTDOOR AMBIENT TEMPERATURE �n'„ 659F 759F 859F 959F 1059E 1159E N ENTERING INDOOR WET BULB TEMPERATURE Ql D: AIRFLOW 59 63 67 71 59 63 67 71 59 63 1 67 71 59 1 63 1 67 71 59 63 1 67 71 59 63 67 71 MBh 51.9 53.8 58.9 - 50.7 52.5 57.6 - 49.5 51.3 56.2 - 48.3 50.0 54.8 - 45.9 47.5 52.1 - 42.5 44.0 48.2 - S/T 0.74 0.62 0.43 0.77 0.64 0.45 0.79 0.66 0.46 0.81 0.68 0.47 0.85 0.71 0.49 0.85' 0.71 0.49 AT 20 18 13 20 18 13 21 18 13 21 18 14 20 18 13 19 16 12 1750 kW 3.55 3.62 3.73 3.80 3.88 3.99 4.03 4.11 4.23 4.22 4.31 4.44 4.39 4.48 4.62 4.53 4.63 4.77 Amps 13.2 13.5 14.0 14.3 14.6 15.1 15.5 15.9 16.4 16.6 17.0 17.5 17.6 18.0 18.6 18.6 19.1 19.7 HiPR 217 233 246 243 262 276 276 297 314 315 339 358 354 381 403 391 421 445 Lo PR 103 109 119 109 115 126 113 120 131 118 126 138 124 132 144 128 137 149 MBh 51.4 53.2 58.3 50.2 52.0 57.0 49.0 50.8 55.6 47.8 49.5 54.3 45.4 47.1 51.6 42.1 43.6 47.8 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 0.70 0.48 U 21 18 14 21 19 14 21 19 14 22 19 14 21 18 14 20 17 13 70 1625 kW 3.55 3.61 3.72 3.80 3.87 3.99 4.02 4.10 4.22 4.21 4.30 4.43 4.38 4.47 4.61 4.52 4.61 4.76 Amps 13.2 13.5 13.9 14.2 14.6 15.1 15.5 15.8 16.3 16.5 16.9 17.5 17.6 18.0 18.6 18.6 19.0 19.7 HiPR 216 232 245 242 261 275 276 297 313 314 338 357 353 380 401 390 420 443 Lo PR 102 109 119 108 115 126 112 120 131 118 126 137 124 132 144 128 136 149 MBh 53.2 55.1 60.4 51.9 53.8 59.0 50.7 52.5 57.6 49.5 51.3 56.2 47.0 48.7 53.4 43.5 45.1 49.4 rt S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 0.74 0.51 n AT 17 15 11 17 15 11 17 15 11 17 15 11 17 15 11 16 14 10 z 2250 kW 3.60 3.67 3.77 3.85 3.93 4.05 4.08 4.16 4.29 4.28 4.36 4.50 4.44 4.54 4.68 4.59 4.69 4.83 o Amps 13.4 13.7 14.2 14.5 14.8 15.3 15.7 16.1 16.6 16.8 17.2 17.8 17.9 18.3 18.9 18.9 19.4 20.0 O a HiPR 220 237 250 247 266 281 281 303 319 320 345 364 360 388 409 398 428 452 d Lo PR 1 104 111 121 110 117 128 115 122 133 120 128 140 126 134 147 131 139 152 p 3 Z 0o MBh 52.8 54.3 58.8 63.1 51.5 53.1 57.4 61.6 50.3 51.8 56.1 60.2 49.1 50.5 54.7 58.7 46.6 48.0 52.0 55.8 43.2 44.5 48.1 51.7 C) o S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42 O AT 23 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 22 20 17 11 n 1750 kW 3.58 3.65 3.76 3.87 3.83 3.91 4.03 4.15 4.06 4.14 4.26 4.40 4.25 4.34 4.48 4.62 4.42 4.51 4.65 4.80 4.57 4.66 4.81 4.96 Amps 13.4 13.7 14.1 14.6 14.4 14.8 15.2 15.8 15.6 16.0 16.5 17.2 16.7 17.1 17.7 18.3 17.8 18.2 18.8 19.5 18.8 19.3 19.9 20.7 HiPR 219 235 249 259 246 264 279 291 279 301 317 331 318 342 361 377 358 385 407 424 395 425 449 469Ln 'n Lo PR 104 110 121 128 110 117 127 136 114 121 132 141 120 127 139 148 125 133 146 155 130 138 151 160 MBh 52.2 53.8 58.2 62.5 51.0 52.5 56.9 61.0 49.8 51.3 55.5 59.6 48.6 50.0 54.2 58.1 46.2 47.5 51.5 55.2 42.8 44.0 47.7 51.2 01 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 O AT 24 23 - 18 13 25 23 19 13 25 23 19 13 25 23 19 13 25 23 19 13 23 21 17 12 75 1625 kW 3.57 3.64 3.75 3.86 3.82 3.90 4.02 4.14 4.05 4.13 4.25 4.39 4.24 4.33 4.46 4.60 4.41 4.50 4.64 4.79 4.56 4.65 4.80 4.95 00) Amps 13.3 13.6 14.1 14.6 14.4 14.7 15.2 15.8 15.6 16.0 16.5 17.1 16.7 17.1 17.6 18.3 17.7 18.2 18.8 19.5 18.8 19.2 19.9 20.6 HiPR 218 235 248 259 245 263 278 290 278 300 316 330 317 341 360 376 357 384 405 423 394 424 448 467 Lo PR 103 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 14S 155 129 138 150 160 n MBh 54.1 55.7 60.3 64.7 52.8 54.4 58.9 63.2 51.6 53.1 57.5 61.7 50.3 51.8 56.1 60.2 47.8 49.2 53.3 57.2 44.3 45.6 49.3 52.9 S/T 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.93 0.84 0.63 0.41 0.96 0.86 0.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44 AT 19 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10 2250 kW 3.62 3.69 3.80 3.92 3.88 3.96 4.08 4.20 4.11 4.19 4.32 4.45 4.31 4.40 4.53 4.68 4.48 4.57 4.72 4.87 4.63 4.73 4.87 5.03 � Amps 13.6 13.9 14.3 14.8 14.6 15.0 15.5 16.0 15.9 16.3 16.8 17.4 17.0 17.4 17.9 18.6 18.0 18.5 19.1 19.8 19.1 19.6 20.2 21.0 HiPR 223 239 253 264 250 269 284 296 284 306 323 337 323 348 368 383 364 392 414 431 402 433 457 477 Lo PR 106 112 123 131 111 119 129 138 116 123 135 143 122 129 141 151 128 136 148 158 132 140 153 163 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACOA(TVA)conditions Amps=outdoor unit amps(comp.+fan) �I � High and low pressures are measured at the liquid and suction service valves. kW=Total system power CD OUTDOOR AMBIENT TEMPERATURE k 652F 752F 852F 952F 1052F 1152F D ENTERING INDOOR WET BULB TEMPERATURE O D: AIRIFLOW 59 63 67 71 59 63 1 67 71 1 59 63 67 1 71 59 1 63 67 71 59 63 1 67 1 71 59 1 63 67 71 m MBh 53.7 54.9 58.6 62.7 52.5 53.6 57.3 61.2 51.2 52.3 55.9 59.8 50.0 51.0 54.5 58.3 47.5 48.5 51.8 55.4 44.0 44.9 48.0 51.3 U S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 0.99 0.80 0.60 1.00 1.00 0.81 0.61 p AT 26 25 22 17 26 25 22 18 26 25 22 18 26 26 22 18 25 25 22 17 23 24 20 16 EZ 1750 kW 3.61 3.68 3.78 3.90 3.86 3.94 4.06 4.18 4.09 4.17 4.30 4.43 4.29 4.38 4.51 4.65 4.46 4.55 4.69 4.84_ 4.60 4.70 4.85 5.00 Z Amps 13.5 13.8 14.2 14.8 14.5 14.9 15.4 15.9 15.8 16.2 16.7 17.3 16.9 17.3 17.8 18.5 17.9 18.4 19.0 19.7 19.0 19.5 20.1 20.9 G) Hi PR 221 238 251 262 248 267 282 294 282 304 321 334 321 346 365 381 361 389 411 428 399 430 454 473 Lo PR 105 112 122 130 111 118 129 137 115 122 134 142 121 129 140 150 127 135 147 157 131 139 152 162 n MBh 53.2 54.3 58.1 62.1 51.9 53.1 56.7 60.6 50.7 51.8 55.4 59.2 49.5 50.5 54.0 57.7 47.0 48.0 51.3 54.8 43.5 44.5 47.5 50.8 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59 AT 27 26 23 18 28 26 23 18 28 27 23 18 28 27 23 19 27 26 23 18 25 25 21 17 (n 80 1625 kW 3.60 3.67 3.77 3.89 3.85 3.93 4.05 4.17 4.08 4.16 4.29 4.42 4.28 4.37 4.50 4.64 4.45 4.54 4.68 4.83 4.59 4.69 4.84 4.99 ti Amps 13.4 13.8 14.2 14.7 14.5 14.8 15.3 15.9 15.7 16.1 16.7 17.3 16.8 17.2 17.8 18.5 17.9 18.3 18.9 19.6 18.9 19.4 20.1 20.8 Hi PR 220 237 2S0 261 247 266 281 293 281 303 320 333 320 345 364 380 360 388 410 427 398 428 452 472 Lo PR 105 111 121 129 110 117 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162 MBh 55.0 56.2 60.1 64.2 53.8 54.9 58.7 62.7 52.5 53.6 57.3 61.2 51.2 52.3 55.9 59.7 48.6 49.7 53.1 56.8 45.1 46.0 49.2 52.6 a) S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 1.00 0.85 0.63 AT 22 21 18 14 22 21 18 15 21 21 18 15 21 21 18 15 20 20 18 15 18 19 17 14 2250 kW 3.65 3.72 3.83 3.95 3.91 3.99 4.11 4.23 4.14 4.23 4.35 4.49 4.34 4.43 4.57 4.72 4.52 4.61 4.75 4.91 4.66 4.76 4.91 5.07 n aQ o Amps 13.7 14.0 14.4 15.0 14.8 15.1 15.6 16.2 16.0 16.4 17.0 17.6 17.1 17.5 18.1 18.8 18.2 18.7 19.3 20.0 19.3 19.8 20.4 21.2 n Hi PR 225 242 255 266 252 271 287 299 287 309 326 340 327 352 371 387 368 396 418 436 406 437 462 481 Lo PR 107 113 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 159 133 142 155 165 1p MBh 54.6 55.7 58.3 62.2 53.4 54.4 57.0 60.8 52.1 53.1 55.6 59.3 50.8 51.8 54.3 57.9 48.3 49.2 51.6 55.0 44.7 45.6 47.8 50.9 O) o S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 O 3 AT 28 27 26 22 28 28 26 23 27 28 26 23 27 27 26 23 25 26 26 23 23 24 24 21 1750 kW 3.63 3.70 3.81 3.93 3.89 3.97 4.09 4.21 4.12 4.20 4.33 4.47 4.32 4.41 4.55 4.69 4.49 4.59 4.73 4.88 4.64 4.74 4.89 5.04 k Amps 13.6 13.9 14.4 14.9 14.7 15.0 15.5 16.1 15.9 16.3 16.8 17.5 17.0 17.4 18.0 18.7 18.1 18.5 19.2 19.9 19.2 19.6 20.3 21.1 Hi PR 223 240 254 265 251 270 285 297 285 307 324 338 ' 324 349 369 385 365 393 415 433 403 434 458 478 n Lo PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 149 158 132 141 154 164 C) Z MBh 54.1 55.1 57.8 61.6 52.8 53.9 56.4 60.2 51.6 52.6 55.1 58.8 50.3 51.3 53.7 57.3 47.8 48.7 51.0 54.5 44.3 45.1 47.3 50.4 S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77 AT 29 29 27 23 29 29 27 24 29 29 27 24 28 29 28 24 27 28 27 24 25 26 25 22 85 1625 kW 3.62 3.70 3.80 3.92 3.88 3.96 4.08 4.20 4.11 4.19 4.32 4.46 4.31 4.40 4.54 4.68 4.48 4.57 4.72 4.87 4.63 4.73 4.87 5.03 Amps 13.6 13.9 14.3 14.8 14.6 15.0 15.5 16.0 15.9 16.3 16.8 17.4 17.0 17.4 18.0 18.6 18.0 18.5 19.1 19.8 19.1 19.6 20.2 21.0 Hi PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 383 364 392 414 431 402 433 457 477 Lo PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163 MBh 56.0 57.1 59.8 63.8 54.7 55.8 58.4 62.3 53.4 54.4 57.0 60.8 52.1 53.1 55.6 59.3 49.5 50.4 52.8 56.4 45.8 46.7 48.9 52.2 5/T 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82 AT 23 23 22 19 22 23 22 19 22 22 22 19 21 22 22 19 20 21 22 19 19 19 20 17 2250 kW 3.68 3.75 3.86 3.98 3.94 4.02 4.14 4.27 4.17 4.26 4.39 4.53 4.38 4.47 4.61 4.75 4.55 4.65 4.79 4.95 4.70 4.80 4.95 5.11 Amps 13.8 14.1 14.6 15.1 14.9 15.3 15.8 16.3 16.2 16.6 17.1 17.7 17.3 17.7 18.3 19.0 18.4 18.8 19.5 20.2 19.5 19.9 20.6 21.4 Hi PR 227 244 258 269 255 274 289 302 290 312 329 343 330 355 375 391 371 400 422 440 410 441 466 486 Ln �^ Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 138 151 161 135 143 156 167 Gl V' IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(camp.+fan) X rn High and low pressures are measured at the liquid and suction service valves. kW=Total system power tin OUTDOOR AMBIENT TEMPERATURE N 652F 752F 852F 952F 1052F 11591' N ENTERING INDOOR WET BULB TEMPERATURE O� D: AIRFLOW 59 63 67 71 59 63 67 71 59 63 1 67 1 71 59 63 67 71 59 63 67 71 59 63 1 67 71 MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 - S/T 0.66 ' 0.55 0.38 0.68 0.57 0.39 0.70 0.58 0.40 0.72 0.60 0.42 0.75 0.62 0.43 0.75 0.63 0.44 AT 21 18 14 21 19 14 21 19 14 22 19 14 21 18 14 20 17 13 1550 kW 3.75 3.83 3.95 4.04 4.13 4.27 4.31 4.40 4.55 4.54 4.64 4.79 4.73 4.84 5.00 4.90 5.01 5.18 Amps 13.4 13.8 14.3 14.6 15.0 15.5 16.0 16.4 17.0 17.2 17.6 18.3 18.4 18.8 19.5 19.5 20.0 20.8 HiPR 227 244 248 257 276 280 292 314 318 333 358 363 359 386 392 426 458 464 Lo PR 113 116 127 116 120 131 120 124 135 123 127 139 126 130 141 129 133 145 MBh 55.9 57.9 63.4 54.6 56.5 62.0 53.3 55.2 60.5 52.0 53.9 59.0 49.4 51.2 56.1 45.7 47.4 51.9 S/T 0.69 0.58 0.40 0.71 0.60 0.41 0.73 0.61 0.42 0.76 0.63 0.44 0.78 0.66 0.45 0.79 0.66 0.46 AT 20 18 13 20 18 13 20 18 13 21 18 14 20 18 13 19 16 12 70 1750 kW 3.78 3.86 3.99 4.08 4.17 4.31 4.34 4.44 4.59 4.57 4.68 4.83 4.77 4.88 5.05 4.94 5.06 5.23 Amps 13.6 13.9 14.4 14.8 15.1 15.7 16.1 16.6 17.2 17.3 17.8 18.4 18.5 19.0 19.7 19.7 20.2 21.0 HiPR 229 247 250 259 279 283 295 317 322 336 361 366 363 390 396 430 462 469 Lo PR 114 117 128 117 121 132 121 125 136 124 128 140 127 131 143 130 134 146 rT MBh 56.1 58.2 63.7 54.8 56.8 62.3 53.5 55.5 60.8 52.2 54.1 59.3 49.6 51.4 56.3 - 45.9 47.6 52.2 n S/T 0.70 0.58 0.40 0.72 0.60 0.42 0.74 0.62 0.43 0.77 0.64 0.44 0.80 0.66 0.46 0.80 0.67 0.46 Z g AT 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 17 15 11 rri 2000 kW 3.81 3.89 4.02 4.11 4.20 4.34 4.38 4.48 4.63 4.61 4.72 4.88 4.81 4.92 5.09 4.98 5.10 5.27 O o Amps 13.7 14.1 14.6 14.9 15.3 15.8 16.3 16.7 17.3 17.5 18.0 18.6 18.7 19.2 19.9 19.9 20.4 21.2 0 HiPR 232 249 253 262 282 286 298 320 325 339 365 370 366 394 400 434 467 474 Q a Q 3 Lo PR 115 119 129 - 118 122 133 - 122 126 138 - 126 130 141 - 128 132 144 - 131 135 148 - Z 3 Q 66, MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3 52.8 57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0 O 0 S/T 0.75 0.67 0.51 0.33 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.85 0.76 0.58 0.37 0.86 0.77 0.58 0.37 n AT 24 23 18 13 25 23 19 13 25 23 19 13 25 23 19 13 25 23 19 13 23 21 17 12 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 Ln HiPR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 O1 MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8 54.4 58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6 0) S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39 ~' I-a AT 23 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 24 22 18 12 22 20 17 11 Z1 75 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 5.23 5.41 Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 n HiPR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 � Lo PR 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 MBh 57.1 58.8 63.6 68.3 55.8 57.4 62.1 66.7 54.4 56.0 60.7 65.1 53.1 54.7 59.2 63.5 50.4 51.9 56.2 60.3 46.7 48.1 52.1 55.9 1,10 5/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40 N AT 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10 Ql 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 O Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.S 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 + HiPR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 m Lo PR 1 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 1 128 132 144 154 1 131 135 148 157 IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)conditions Amps=outdoor unit amps(comp.+fan) y High and low pressures are measured at the liquid and suction service valves. kW=Total system power 000 OUTDOOR AMBIENT TEMPERATURE rr 659F 759F 859F 959F 1059F 1159F ENTERING INDOOR WET BULB TEMPERATURE O D= AIRFLOW 59 63 67 1 71 59 1 63 67 71 1 59 63 67 71 1 59 1 63 F 67 71 59 63 67 71 59 63 67 71m MBh 56.1 57.4 61.3 65.5 54.8 56.0 59.9 64.0 53.5 54.7 58.4 62.5 52.2 53.4 57.0 60.9 49.6 50.7 54.2 57.9 45.9 46.9 50.2 53.6 rz) S/T 0.82 0.77 0.63 0.47 0.85 0.80 0.65 0.48 0.87 0.82 0.66 0.50 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 0.94 0.88 0.72 0.54 p AT- 27 26 23 18 28 26 23 18 28 26 23 18 28 27 23 j 19 27 26 23 18 26 25 21 17 a EZ 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 ; 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Z Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 G) Hi PR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 1 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 n MBh 57.8 59.1 63.1 67.5 56.5 57.7 61.6 65.9 55.1 56.3 60.2 64.3 53.8 55.0 58.7 62.8 51.1 52.2 55.8 59.6 47.3 48.4 51.7 55.2 S/T 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.93 0.75 0.56 AT 26 25 22 17 26 25 22 18 26 25 22 18 27 26 22 18 27 25 22 17 25 24 20 16 (n 80 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 S.23 S.41 N Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 p Hi PR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 (3) Lo PR 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 H MBh 58.1 59.4 63.4 67.8 S6.7 58.0 61.9 66.2 55.4 56.6 60.5 64.6 54.0 55.2 59.0 63.1 51.3 52.5 56.0 59.9 47.6 48.6 51.9 S5.5 T S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.76 0.57 \ AT 23 22 19 15 24 23 20 16 24 23 20 16 24 23 20 16 24 22 19 16 22 21 18 15 IN 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 T o Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.5 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 A 0a Hi PR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 Lo PR 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 128 132 144 154 131 135 148 157 v � QOM' MBh 57.1 58.2 61.0 65.0 55.8 56.9 59.6 63.5 54.5 55.5 58.1 62.0 53.1 54.2 56.7 60.5 50.5 51.4 53.9 57.5 46.7 47.7 49.9 53.2 � 0 S/T 0.86 0.83 0.75 0.61 0.89 0.86 0.78 0.63 0.91 0.88 0.80 0.65 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 0.99 0.95 0.86 0.70 + 3 AT 29 29 27 23 29 29 27 24 29 29 27 24 30 29 28 24 29 29 27 24 27 27 25 22 m 1550 kW 3.75 3.83 3.95 4.08 4.04 4.13 4.27 4.41 4.31 4.40 4.55 4.70 4.54 4.64 4.79 4.96 4.73 4.84 5.00 5.18 4.90 5.01 5.18 5.36 Amps 13.4 13.8 14.3 14.8 14.6 15.0 15.5 16.2 16.0 16.4 17.0 17.7 17.2 17.6 18.3 19.0 18.4 18.8 19.5 20.3 19.5 20.0 20.8 21.6 k Hi PR 227 244 248 253 257 276 280 286 292 314 318 326 333 358 363 371 359 386 392 400 426 458 464 475 Lo PR 113 116 127 135 116 120 131 139 120 124 135 144 123 127 139 148 126 130 141 151 129 133 145 154 n MBh 58.8 60.0 62.8 67.0 57.5 58.6 61.3 65.4 56.1 57.2 59.9 63.9 54.7 S5.8 58.4 62.3 52.0 53.0 55.5 59.2 48.2 49.1 51.4 54.8 Z S/T 0.90 0.87 0.78 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.90 0.73 'I AT 28 27 26 22 28 28 26 23 28 28 26 23 28 28 26 23 27 28 26 23 25 26 24 21 85 1750 kW 3.78 3.86 3.99 4.12 4.08 4.17 4.31 4.45 4.34 4.44 4.59 4.74 4.57 4.68 4.83 5.00 4.77 4.88 5.05 5.22 4.94 5.06 5.23 5.41 Amps 13.6 13.9 14.4 15.0 14.8 15.1 15.7 16.3 16.1 16.6 17.2 17.9 17.3 17.8 18.4 19.2 18.5 19.0 19.7 20.5 19.7 20.2 21.0 21.8 Hi PR 229 247 250 256 259 279 283 289 295 317 322 329 336 361 366 374 363 390 396 404 430 462 469 479 Lo PR 114 117 128 137 117 121 132 141 121 125 136 145 124 128 140 149 127 131 143 152 130 134 146 156 MBh 59.1 60.3 63.1 67.3 57.7 58.8 61.6 65.8 56.4 57.4 60.2 64.2 5S.0 56.0 58.7 62.6 52.2 53.2 55.8 59.5 48.4 49.3 51.7 55.1 S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.84 0.69 1.00 0.97 0.87 0.7.1 1.00 1.00 0.91 0.73 1.00 1.00 0.91 0.74 AT 25 24 23 20 25 25 23 20 25 25 23 20 25 25 24 20 24 24 23 20 22 23 22 19 2000 kW 3.81 3.89 4.02 4.15 4.11 4.20 4.34 4.49 4.38 4.48 4.63 4.78 4.61 4.72 4.88 5.04 4.81 4.92 5.09 5.26 4.98 5.10 5.27 5.46 Amps 13.7 14.1 14.6 15.1 14.9 15.3 15.8 16.5 16.3 16.7 17.3 18.0 17.5 18.0 18.6 19.4 18.7 19.2 19.9 20.7 19.9 20.4 21.2 22.0 Hi PR 232 249 253 258 262 282 286 292 298 320 325 332 339 365 370 378 366 394 400 408 434 467 474 484 `^ Lo PR 115 119 129 138 118 122 133 142 122 126 138 147 126 130 141 151 128 132 144 154 131 135 148 157 G) V^ IDB:Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps=outdoor unit amps(comp.+fan) x High and low pressures are measured at the liquid and suction service valves. kW=Total system power 87 8 5 4 31 2 1 I^ ECN REV 2CNE DESCRPTO CHK DR BATE G1 N )00000IX A )0000( 4�ilAL RELEASE - X N CJl E E DIMENSIONS MODEL W„ D„ H„ GSX160181** 29 29 32 GSX160241** 29 29 32 GSX160301** 29 29 35Y4 GSX160311** 29 29 39%2 GSX160361** 29 29 39%2 D GSX160371** 35'/2 35%2 35% D GSX160421** 35'/2 35%2 35'/< GSX160481** 35'/2 35%2 39% W GSX160601** 35% 35%: 1 37'/ D *Note:All the Dimensions(W,D,H)are for reference only. on 0 Q C DIMENSIONS MODEL C W„ D" H" Z) 3 4 ' GSX16S181A* 29 29 32 1. GSX16S241A* 29 29 32 0 GSX16S301A* 29 29 35 GSX165361A* 29 29 39%2 GSX16S421A* 35%2 35%2 35'/° GSX16S481A* 35%2 35%2 39%2 *Note:All the Dimensions(W,D,H)are for reference only. B B H 4 Goodman Manufacturing Co., L.P. AA GSX16 °°cuacviw.[x; Q v2r.:mMron.cmrt° SPECLALCWIRACTERISTICS: Ca.9UEMSAfLt11A1ERu1SSFEOFlEDHEF£C1Ay1ALSO WON IOTHEAIPI.IfJBLESECTl6'IOiWOpYNeSP82101M'OROJMfiHP IVAi 111r, 0010t5U10ORAl70 STP&RD FORFR.FEEL A�F21% MC.11 2,11 _-._. _ S!010F1 m Q=66IGN,A �=CRIMAL CHARACTERSTIC SOTICANT GVRACTERISTIC CvFwm4FFAFERTY OF THE OOODUN WUACTLAN0 C0.PkiY.LP.TUT TO Es<lTS(1MTOOTFOrS FED.CA UOFOR ANf PLRFO°.E ucz`..F,° FEV HEPTA 99HOR2EDNKRETM MUST FEWTIAUEDL.PONDFWJQONCOMUTIMOFORDER ORODERRAPOKFOR MMaIRWAS" W%.00 O� A 1 8 7 6 5 4 3 ��wl°2 1 LU O LVJB CONTROL13OX OUTDOOR POWER SUPPLY _ I YL—Y SEE NOTE 1 _ SEE RATING PLATE BL—C }} I I I I 'n I Ti C T2 I I G7 L1 5 SR 2 1 SC C L2 COLOR CODE 10 H C /� BK -BLACK �1 BL----BLUE J C J+ S BR----.-BROWN Z RCCF P ORORANGEm 0 COMP SC PU-----PURPLE o0 1 F 91 RDREDw Usti R WH---WHITE r 7� BL B YL---YELLOW z Co R i t w J} SA � Q O 10 P (IF USED) NJ R WIRING CODE ,p B R FACTORY WIRING y kA SR YL'tT2 2� HIGH VOLTAGE CIA ��')' `. 5 LOW VOLTAGE ri C OPTIONAL HIGH VOLTAGE 1 � FIELD WIRING V 1 RD HIGH VOLTAGE YL PU R I '1 00 RCCF H C F COMPONENT CODE QL C---------CONTACTOR t!I _ CM--OUTDOOR FAN MOTOR C —YL ' COMP----COMPRESSOR V YL BR 10----INTERNALOVERLOAD (N LVJB-----LOW VOLTAGE JUNCTION BOX RCCF--RUN CAPACITOR FOR COMPRESSOR&FAN N 0 SA---START ASSIST SC----START CAPACITOR FOR COMPRESSOR(OPTIONAL) SA SR------START RELAY FOR COMPRESSOR(OPTIONALI Q Ti0 T20 (IF USED) NOTE 2 CONTROLS SHOWN WITH THERMOSTAT IN'OFF POSITION. � L7O L2Q RO ALTERNATE DOUBLE POLE CONTACTOR Y C Z�LJ SEE E 1 COMP J— NOTES: MAIN — 1)TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK& RD EQUIPMENT GROUND INDOOR THERMOSTAT. MAIN BK AUX SEE NOTE 3 2)START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3)USE COPPER CONDUCTORS ONLY. PU C S AUX yl BR LL 10 ■ ■ BK R t USE N.E.C.CLASS 2 WIRE ■ ■ CM 0140R00015P-C LrI Gl LnWiring is subject to ch ange.Alwaysrefertothewiring High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L WARNING J L diagram or the unit for the most up-to-date wiring. sources may be present.Failure to do so may cause property damage,personal injury,or death. rn Ln T x � LVJB O1 CONTROLBOX OUTDOOR POWER SUPPLY BUPK—YSEE NOTE 1 SEE RATING PLATE BL—C SEE NOTE 3 SEE NOTE 3 - BL/PK L1 1-2 5 SR � Sc C 10 COLOR CODE C 1 PJ-F�•.S ' T17 BKBLACKJz LRcc1 BL-------------BLUE m 0 COMP s0 BUPK--------BLUE/PINK STRIPEp p yggt�r R F • J BR---------BROWN v r r OR----------ORANGE a 1��.,�I�iCV�7 BL Brc PU--------------PURPLE f FBK BK RD RD RD RD-----•—•--RED W 0 10 PJ`vv SA WH-------------WHITE _ ` (IF USED) J J W rz�l ao <0 BK Sa u� L2C, RD I YL----------------YELLOW O ICM Hit, 5. i V 2f�}•k{ RD YL 0 RD O 0WIRING CODE C YL FACTORY WIRING —;i'riGQG4QG Pu l HIGH VOLTAGE c HERM YL LOW VOLTAGE RD F YLYL I OPTIONAL HIGH VOLTAGE —�- 69, BR RCCF ` n0 1 FIELD WIRING HPS C HIGH VOLTAGE � 1 SA 710 Tzo B�rc (iF USED) LOW VOLTAGE — — T1T 1TT �N-T_—p L1p L2pRD BL PK ALTERNATE DOUBLE Y C 5 POLE CONTACTOR SEE NOTE 1 SEE NOTE Z NOTES: G) 1 COMPONENT CODE 1)TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND 1INDOOR THERMOSTAT.USE N.E.C.CLASS 2 WIRE. COMP = C----------CONTACTOR 2) START ASSIST FACTORY n MAIN = CM-----•----OUTDOOR FAN MOTOR EQUIPPED WHEN REQUIRED, ni R0 EQUIPMENT GROUND COMP••------COMPRESSOR 3) USE COPPER CONDUCTORS ONLY. MAIN BK A .� SEE NOTE 3 HPS----------HIGH PRESSURE SWITCH MAIN Pu 10-----------INTERNALOVERLOAD HPS LVJB---•----LOW VOLTAGE JUNCTION BOX AUX YL IO RCCF--------RUN CAPACITOR FOR COMPRESSOR&FAN IO Zl (S) SA----- ASSIST _ ' BK SC------------START CAPACITOR FOR COMPRESSOR _ lG)R� SR-------------START RELAY FOR COMPRESSOR x N cm CONTROLS SHOWN WITH THERMOSTAT IN'OFF'POSITION. � 0140800617-A (/1 H 00 iV N Wiring is subject to change.Always refer tothewiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L LU diagram or the unit for the most up-to-date wiring. WARNING sources may be present.Failure to do so may cause property damage,personal injury,or death. 7 W N LVJB CONTROL BOX YL I OUTDOOR PLATE i BL-C t} SEENOTE1 I I T1 T2 L1 5 C SR 2 1 SC C COLOR CODE 10 H C BK--BLACK BL---BLUE J C J+ S Ln BR BROWN I w Z P RCC I OR -ORANGE m O COMP 1 SC PuPURPLE ' o O �Hi RD------- -RED w U '(' R WH------WHITE YLYELLOWz BL B R B GR/YL------GREEN/YELLOW STRIPE w SA `• B B 1 I GRGREENT <a CM (IF USED) O TI T2 R •�•� WIRING CODE IV SR FACTORYWIRING BK L1 L2 13K ')F YL L7 L2 HIGH VOLTAGE wY 9(. S C LOW VOLTAGE OPTIONAL HIGH VOLTAGE ���� �-- CH 1 1 FIELDWIRING RD HIGH VOLTAGE r YL PU •RO GR II OO I ' RCC H C ( COMPONENTCODE d ' C----CONTACTOR E3 CM--OUTDOOR FAN MOTOR QJ -YLI COMP—COMPRESSOR C =Y 10--INTERNAL OVERLOAD VL LVJB-----LOW VOLTAGE JUNCTION BOX - ' 1 I RCC----RUN CAPACITOR FOR COMPRESSOR 0 SA------START ASSIST CM ' I J SC--START CAPACITOR FOR COMPRESSOR(OPTIONAL) B SA L SR--START RELAY FOR COMPRESSOR(OPTIONAL) Q T10 T2O I (IF USED CH----CRANKCASE HEATER YL NO17 TE 2 _.RO CONTROLS SHOWN WITH THERMOSTAT IN'OFF'POSITION. L1Q L2p 1 ALTERNATE DOUBLE POLE CONTACTOR Y C frT1 COMP 1 ' NOTES: BL F-1MAIN1)TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK S GR/YL RO EQUIPNIENTGROUND INDOOR THERMOSTAT. BK AUX SEE NOTE 3 2)START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3)USE COPPER CONDUCTORS ONLY. rCHWH �JGND L1 BKYL GR YI ti YL L2 BR y c s "f-t USE N.E.C.CLASS 2 WIRE R _ CM 0140R00287-A Lf) Y, Gl X Wiring is subject to change.Always refer to the wiring High Voltage: Disconnect all power before servicing or installing this unit. Multiple power rn diagram or the unit for the most up-to-date wiring. WARNING sources may be present.Failure to do so may cause property damage,personal injury,or death. 7 r NOTES i SS-GSX16 www.goodmanmfg.com 33 ACCESSORIES MODELI 0181F* 0241F* 0301F* 0311A* 0361F' 0371A* 0. 0•: �.� ABK-20 Anchor Bracket Kit A X X X X X X X X X ABK-21 Anchor Bracket Kit^ ASC-01 Anti-Short Cycle Kit X X X X X X X X X CSR-U-1 Hard-Start Kit X X X X X X CSR-U-2 Hard-start Kit X X X X X CSR-U-3 Hard-start Kit X X FSK01A' Freeze-Protection Kit X X X X X X X X X LSK0242 Liquid-Line Solenoid Kit X X X" X X X X X X LAKT0IA Low-Ambient Kit X X X X X X X X 0130ROi]000S Low-Pressure Switch Kit X X X X X X X X X TXV-302 TXV Kit X X X X TXV-422 TXV Kit X X X TXV-482 TXV Kit X TXV-602 TXV Kit X Contains 20 brackets;four brackets needed to anchor unit to pad Installed on indoor coil ' Field-installed,non-bleed,expansion valve kit. MODEL ABK-20 Anchor Bracket Kit A X X X X X X ABK-21 Anchor Bracket Kit A ASC-01 Anti-Short Cycle Kit X X X X X X CSR-U-1 Hard-start Kit X X X X CSR-U-2 Hard-start Kit X X X CSR-U-3 Hard-start Kit X FSK01A' Freeze Protection Kit X X X X X X LSK02A2 Liquid Line Solenoid Kit X X X X X X LAKT01A Low-Ambient Kit X X X X X X 0130R00000S Low-Pressure Switch Kit X X X X X X TXV-302 TXV Kit X X X TXV-422 TXV Kit X X TXV-482 TXV Kit X TXV-602 TXV Kit Contains 20 brackets;four brackets needed to anchor unit to pad ' Installed on indoor coil 2 Field-installed,non-bleed,expansion valve kit. All AHRI system ratings are accessible in the System Configurator tool"via Partnerl-ink. Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without incurring obligations.9)2020 Goodman Manufacturing Company,L.P. • Houston,Texas • Printed in the USA. 34 www.goodmanmfg.com SS-GSX16