HomeMy WebLinkAboutEvaluation ReportTRINITY I ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203)262-9245 ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R8 12505 NW 44th Street FL6332-RB Coral Springs, FL 33065 Date of Issuance: 08/08/2008 (888) 774-1419 Revision 8:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The fa s mile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. VTRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6`h Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: gaint Examination Reference Date ERD (TST 6049) Static Uplift —SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift —SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES (EVL2396) 20121BC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI (TST5878) Static Uplift —SSTD 11 ECM-001-02-01 09/21/2001 PRI(TST5878) Static Uplift —SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST5878) Static Uplift —SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST5878) Static Uplift —SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST5878) Static Uplift —SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST5878) Static Uplift —SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008 PRI(TST5878) Static Uplift —SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD it ECM-006-02-01 06/13/2008 PRI(TST5878) Static Uplift —SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST5878) Static Uplift—SSTD 11 ECM-008-02-01 06/13/2008 UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp.06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives PrOPackO 30 & 100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certificate ofAuthoriration #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 2 of 9 �l I KINITY ERD 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE I: FIELD TILES IN ICP ADHESIVES POLVSET®AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA 2 TOl MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (SINGLE OR EOWINUOUSPADDY) PLAEEMEW 4 TO Z WRONOFSAFEWALREADYAPPOEU FOR IWEROEPENOEM(TWO PADDY) PMCEMEW Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable overturning Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (2x7-inch, -30 gram) 60 Clay or Flat Independent; Single Paddy, Large (2%10-inch, -45 gram) 112 Concrete Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at file overlap) 54 Independent; Single Paddy, Medium (2x7-inch, ^30 gram) 39 Clay or Low/ Independent; Single Paddy, Large (2x10-inch, -54 gram) 67 Concrete Medium Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap) 58 Clay High Independent; Single Paddy, Large (240-inch, -45 gram) 134 Independent; Single Paddy, Medium (2x7-inch, -30 gram) 65 Concrete Clay High Independent; Single Paddy, Large (2x10-inch, -63 gram) 109 Interdependent; Two Paddy (44-Inch on underlayment, 2x4-inch at the overlap) 40 Clay Barrel 2x10-inch x -35 gram for pans; 2 @ 1x10-inch x-17 gram for cap 147 Concrete Barrel 2x10-inch x -35 gram for pans; 2 @ 1x10-inch x `17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy ("34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy (- 34 gram/ft) 116 stringer ClayCap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2'k" screw; Overlap: 1 x 6 inch (" 50.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2W screw; Overlap: 1 x 6 inch (-10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization R9503 6D' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 3 of 9 v I KINITY ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 3A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLysETO AH-16O ALLOWABLE'UPLIFr RESISTANCE PERFORMANCE DATA 3 TO I MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY) PLACEMENT 4 TO MARGIN OFSAFEFYALREADYAPPDED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay 2x PT ridge board Independent: Continuous Paddy (^34 gram/ft) 116 Concrete 2X PT ridge board Independent: Continuous Paddy(- 34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #10 x 2%" screw; 90 Overlap: 1 x 6 inch ("'10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2'/:" screw; Sfi Overlap: 1 x 6 inch (^'30.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (^34 gram/ft) 169 Concrete galvanized only Clay or Trim Lock" (FL5374): aluminum, Independent: Continuous Paddy ("34 gram/ft) 173 Concrete galvanized, GolvalumeO or stainless steel Clay or Trim Lack— Plus (FL5374): aluminum, Independent: Continuous Paddy ("'34 gram/ft) 178 Concrete galvanized, Galvalume® orstainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (^ 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy (^' 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section S. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC.—QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RB Certificate OfAutharization H9503 6� EDITION(20171 FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset® AH-160; (888) 774.1419 Revision 8:10/12/2017 Page 4 of 9 �I I KINITY I ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddy: Nail through plastic cement Paddy (Beneath rile) (when requi:c, Unc dayerent o It 7in. Battens option al ° Eave Course +�} a 10 in. Fascia 2in Eave Closure Flat/Low Profile Tile Nall through plastic cement (when required) Paddy (Beneath rile) Underlayment 71n.. In. �`•,`.. Battens optional`' loin. 21n. Eave Closure Eave Course Fazcla Medium Profile Tile Nail through plastic ce (when required) Paddy (Beneath Tile) Underlayment 7In.. In. Battens optional EaveCourse Fascia We iphole to in tin: Eaveclosure Drip edge High Profile Tile Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyseta AH-160; (898) 774.1419 Revision 8: 10/12/2017 Page 5 of 9 10.2 Independent, Large Paddy: Underlayment 1 41 0 in\ Battens optional �'Y ° Eave Course 0 e �r�y~'K"j, 10inf Flat/Low Profile Tile Exterior Research and Design, I.I.C. Certificate of Authorization #9503 " I KIIVITi ERD Nall through plasticcement (when required) Paddy (Beneath7ilel Underlayment 2in.wide Battensoptldnal 010 in. `�2in. Eave Closure Eave Course Fascia Medium Profile Tile Nail through plasticce (when required) Paddy(BeneathTile) Underlayment `IIIY 10 in.x 2 in.wide Battens optlonal IV Eave sr+« mot, Eave Course Fascia Vleephale 10 in tin Eave closure Drip edge High Profile Tile fiTM EDITION (2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polysete AH-160; (888) 774-1419 Evaluation Report 02768.03.06-R8 FL6332-R8 Revision 8: 10/12/2017 Page 6 of 9 10.3 Interdependent, Two Paddy: Nail through plastic cement Paddy (between tiles) (when required) Battens option al ° o Paddy (under tile)) ( Single paddy ontopoftile l r 4z4in. Singleif under til Singie paddy on uifderlaymen[ 2 2x 4in. 0 ° N. 10in. i i n. 2Fasca 2 Eave Closure Flat/Low Profile Tile Exterior Research and Design, U.C. Certificate of Authorization #9503 �I TRINITY ERD Nall through plastic cement Single paddy under tile (when required) Paddy(between tiles) Battens Paddy (under tile) (optional Single paddy ��..on top of slle\ �4 x4in. 2%41 .�i Single paddy on `4ti undedayment - 10in. tin. Eave closure Eave Course Fascia Medium Profile Tile Nail It It pI sticce Single paddy undertile (when required) Paddy (between tiles) Battens optional E Paddy (under tile) fyj ��Singlepaddy an underiaymen[ ice! 4 x4 in. Single 2%4in. paddyon top of No /� Eave Course Fascia weephole Eaveclosure �P Drlp edge High ProffleTile 6' EDITION (2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polyseta AH-160; (888) 774-1419 Evaluation Report 02768.03.06-R8 FL6332-RS Revision 8: 10/12/2017 Page 7 of 9 �I I KINIIY J ERD 10.4 Two Piece Barrel (Cap & Pan) Tile: 1) Pfau enough adhesive to achieve 6s to In contest with the pan tile. 2) Tum CoversupaWe down. Place aabealvs is In. is 1 Inch In fmm cutdao caps of cover) Inswilrosques. En sum 20 G 25 sq. in, contact ama s� seen ala�mwaerme. IUnderlayment (motar shown) f the eave worse cover file. Abut to second worse of end of pan and save r111as are Bush at ease fine. Two. Piece Barrel - High Profile Tile 10.5 Hip and Ridge (independent placement): TO abaeh hyhiaPse to s, a bead o[ICPPolysetbAH•!60 may be applied darn the c®terufew Wpledu_e bond or gnhtaired flares - Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB Certificate of Authorization N9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polysete AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 8 of 9 10.6 Hip and Ridge (interdependent placement): END OF EVALUATION REPORT - �I TRINITY ERD Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6n`EDITION (2017)FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyset® AH-160; (8881 774-1419 Revision 8: 10/12/2017 Page 9 of 9 ltli' � Professional Regulation Floridap *Product Approval n USErt: public User 61m EMdUc pproval Menu > ELRAVgt or Application Search > Applica[lon Lls[> Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL5374-RS Affirmation 2017 Approved East Coast Metals, Inc. 2301 West 8 Lane Hialeah, FL 33010 (305) 885-9991 acastellanos@eastcoast-metals.com Tom Castellanos acastellanos@eastcoast-metals.com Tom Castellanos 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 tcastellanos@eastcoast-metals.com Howard Callender Jr. 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 hcallender@eastcoast-metals.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Architectural Testing, Inc., an Intertek Company 12/31/2020 John W. Knezevich, PE O Validation Checklist - Hardcopy Received FL5374 R5 COI 2015 01 COI Nleminen.Rd( Standard Year FRSA/TRI April 2012 (04-12) 2012 RAS 118 1995 RAS 119 1995 PAS 120 1995 SBCCI SSTD 11 1997 TAS 101 1995 Equivalence of Product Standards Certified By 1 Sections from the Code G I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity 0 yes 0 No 0 N/A FL5374 R5 CDC 2017 09 AFFIRMATION ECM FL5374 6th Edition .(2017)ypdf Product Approval Method Method 1 Option D Date Submitted 09/06/2017 Date Validated 09/06/2017 Date Pending FBC Approval Date Approved 09/10/2017 Summary of Products FL # Model, Number or Name Description - 5374.1 East Coast Metals Channel Metals Preformed metal channels designed for use as a hip & ridge base to which roof tiles are bonded. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5374 R5 II 2015 03 FINAL ER ECM Trim Lock F1_5374- R4.12df Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-178 Created by Independent Third Party: Yes Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 for Evaluation Reports Limits of Use In HVHZ and non-HVHZ jurisdictions, respectively. FL5374 RS AE 2015 03 FINAL ER ECM Trim Lock FL5374- R4.od 2.) The design pressure herein pertains to use in non-HVHZ jurisdictions in conjunction with Table IA of FRSA/TRI April Created by Independent Third Party: Yes 2012 (04-12). Refer to Tables 2A and 2B in the Evaluation Report for all options and associated allowable design pressures. Back Next Contact, Us :: 2601 Blair Stone Road, Tallahassee R 32399 Phone: 850-487-1824 The state of Florida is an AA/EEO employer. Coht 2007-2013 State of Florida :: Privacy Statement :: AccessiblIty Statement :: Refund Statement Under Florida law, email addresses are public remrds. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to Nis entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here Product Approval Accepts: ®® M N securkpitSrlkics• TRINITY ERD EVALUATION REPORT East Coast Metals, Inc. 2301 West 8 Lane Hialeah, FL 33010 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E10240.08.08-R4 FL5374-R4 Date of Issuance:09/03/2008 Revision 4: 03/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: . Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The Facsimile seal appearing was authorbed by Robert Nieminen, P.E. on 03/17/1015. This does not serve as an elsevoNeally signed document Signed, sealed hardcopies hive been tmsnmoed tothe Product Approval Administrator and to the named dent CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �/ TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012 (04-12) 2012 1518.8.1 Installation, HVHZ RAS 118,119 & 120 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1711.2.1 Static Uplift Resistance SEW SSTD 11 1997 3. REFERENCES: gaiity Examination Reference Date ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC(T517393) TAS 101 S10-628R 10/27/2010 PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-004-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008 PRI(TST5878) - TAS 101 ECM-008-02-01 06/13/2008 Florida Building Code Attachment Requirements FRSA/rRI April 2012(04-12) 04/2012 Florida Building Code - HVHZ Attachment Requirements RAS 118,119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing(QUA1844) Quality Control Participation Letter Exp.12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 Or 7-inch L 3/8-inch) heights with 1.5-inch L 1/16-inch) deck -Flanges. Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4 CertiJrcate ofAuthorlsation N950 FL5374-R4 Revision 4: 03/17/2015 Page 2 of 7 NINITY ERD 4.2 Trim Lack Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights with 1.5-inch (± 1/16-inch) deck -flanges. 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch (±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights with 1.5-inch it 1/16-inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI. ➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI. ➢ Aluminum: Min. 0.032±0.002-inch, ASTM 13209, 3003-H14, min. 21 KSI. ➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4 Certgicate ofAuthorhation 119503 FL5374-R4 Revision 4: 03/17/2015 Page 3 of 7 VTRINrry I ERD 5.2 FOR HVHZJURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr), as determined in accordance with RAS 127, not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLEIA: PERFORMANCE LIMrrATuJNS-HVHZ, INDEPENDENT PADDY PLACEMENT _ f2 TO MARGIN OFSAFEIYALREADYAPPNEDj Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement Mt(ft-Ihf) F'(Ibf) Hip &Ridge galvanized clay or 3M'"2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalumea, clay or 3M'"2-Component Foam Independent 171 159 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume®, clay or 3M'"2-Component Foam Independent 177 165 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 TABLE IB: PERFORMANCE LIMITATIONS - HVHZ, INTERDEPENDENT PADDY PLACEMENT _ f4TO1 MARGIN OFSAFET'AL_READYAPPUEDj Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement Mr(ft-Ihf) F'(Ihf) Trim Lock or Trim galvanized, GalvalumeO, clay or 3M'"2-Component Foam Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Interdependent 95 88 Trim Lock galvanized, Galvalume•, clay or 3M'" Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 clay or 3M'" Foam Roof Tile Trim Lock aluminum concrete Adhesive RTA-1 Interdependent 90 84 Trim Lock Plus galvanized, Galvalumet', clay or 3Mm Foam Roof Tile Interdependent 90 84 aluminum or stainless steel concrete Adhesive RTA-1 Trim Lock galvanized, Galvalume°or clay or TILE BOND'" Roof Tile Interdependent 123 117 stainless steel concrete Adhesive Trim Lock aluminum clay or TILE BOND'" Roof Tile Interdependent 79 73 concrete Adhesive Trim Lock Plus galvanized, Galvalume•, clay or TILE BOND'" Roof Tile Interdependent 79 73 aluminum or stainless steel concrete Adhesive Trim Lock galvanized, Galvalume• or clay or Touch'n Seal Storm Bond Interdependent 146 139 stainless steel concrete Roof Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54 concrete Roof Tile Adhesive galvanized, Galvalume•, I clay or Touch 'in Seal Storm Bond Trim Lock Plus aluminum or stainless steel concrete RoofTile Adhesive Interdependent 58 54 Exterior Research and Design, L-C. Evaluation Report E10240.08.08-R4 Certicate of Authorization #9503 FL5374-114 Revision 4: 03/17/2015 Page 4 of 7 �1 1 KINITY ERD 5.3 FOR NON-HVHZJURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructionsfor adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bands the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE 2A: PERFORMANCE LIMLTAniiNS-NON-HVHZ, INDEPENDENT. PADDY PLACEMENT (2 To MARGIN OF SAFETYALREADYAPPLIEOJ Hip/Ridge Metal Tile Adhesive Adhesive Allowable Uplift (Psf) Design Metal Type Placement Hip &Ridge galvanized clay or 3M-2-Component Foam Roof Independent 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume°, aluminum or clay or 3M-2-Component Foam Roof Independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume®, aluminum or clayor 3M-2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 TABLE_2B: PERFORMANCE LIMiTATIONs-NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT (4 TO MARGIN 0F9 FETYMREAOYAPPNEO) _ Hip/Ridge Metal Tile Adhesive Allowable Uplift (psf) Design Metal Type Type Placement Trim Lock or Trim galvanized, Galvalume®, aluminum or day or 3M'" 2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 galvanized, Galvalume• or stainless clay or 3M`" Foam Roof Tile Adhesive Trim Lock steel concrete RTA-1 Interdependent 110 clay or 3M- Foam Roof Tile Adhesive Trim Lock aluminum Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalume•, aluminum or clay or 3M- Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized, Galvalume' or stainless clay or TILE BOND- RoofTile Adhesive Interdependent 152 steel concrete Trim Lock aluminum clay or TILE BOND- Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized, Galvalume®, aluminum or clay or TILE BOND- Roof Tile Adhesive Interdependent 82 stainless steel concrete Trim Lock galvanized, Galvalume® orstainless clay or Touch'n Seal StormBond Roof Interdependent 148 steel concrete Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Plus galvanized, Galvalume-, aluminum or clayor Touch'n Seal Storm Bond Roof Interdependent fit stainless steel concrete Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E30240.08.08-R4 certificate o)Authorizatlon N9503 FL5374-R4 Revision 4: 03/17/2015 Page 5 of 7 VTRINITYIERD 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. it ga. x N-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RA5118, Drawing 13, Detail 3; RA5119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It Is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile adhesive. Exterior Research and Design, LLG Evaluation Report E30240.08.08-R4 CeAiifwte o)Authoruation #9503 FL5374-114 Revision 4: 03/17/201S Page 6 of 7 �l I KINITY ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturers Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other band -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACrURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc.—QUA1844; (717) 764-7700 - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 Certifimte oJAuthorGotlon p950 FL5374-R4 Revision 4:03/17/2015 Page 7 of 7 1 \I I KINITY ERD EVALUATION REPORT East Coast Metals, Inc. 2301 West 8 Lane Hialeah, FL 33010 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E10240.08.08-R4 FL5374-R4 Date of Issuance:09/03/2008 Revision 4: 03/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Sin Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEcnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The fzaimile seal appearing svasauthorhed by Robert Meminen, P.E. on 03/17/2015. This does notserveas an eleNonicallysigned document Signed, sealed hardccpies have been trznsmitted to the Product Approval Administrator and to the named dent CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. VTRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012 (04-12) 2012 1518.8.1 Installation, HVHZ RAS 118, 119 & 120 1995 1523.6.5.2.2 Static Uplift Resistance TA5101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: 9afint Examination Reference Date ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD (TST6G49) Static Uplift Resistance ECM-SC6795.12.14-1 - 02/27/2015 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC (TST7393) TAS 101 510-628R 10/27/2010 PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI (TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-004-02-01 O6/13/2008 PRI (TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008 PRI (TST5878) TAS101 ECM-008-02-01 06/13/2008 Florida Building Cade Attachment Requirements FRSA/TRI April 2012 (04-12) 04/2012 Florida Building Code -HVHZ Attachment Requirements RA5118, 119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing(QUA1844) Quality Control Participation Letter Exp.12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. ' Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4 Certificate oJAuthodrotlon #9503 F .5374-R4 Revision 4: 03/17/2015 Page 2 of 7 VTRINITYIERD 4.2 Trim Lack Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch L 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 K51. ➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI. ➢ Aluminum: Min. 0.032±0,002-inch, ASTM B209, 3003-1-114, min. 21 K51. ➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4 Certiflcote olAuthorization #950 FL5374-114 Revision 4: 03/17/2015 Page 3 of 7 VTRINITYIERD 5.2 FOR HVHZ JURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip &.Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data in Tables SA and SB is supplemental to these prescriptive allowances. Installations of Trim Lack Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr), as determined in accordance with RAS 127, not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is banded to the Channel Metal in its own, single foam paddy, the head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. - I TABLEIA: PERFORMANCE LIMITATIONS- HVHZ, INDEPENDENT PADDY PLACEMENT _ _ (2.T01 MARG)NOFSAFETYA_LREAOYAPP0ED) Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based M,(ft-lbf) F'(Ibf) Hip &Ridge galvanized clay or 3M'"2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalume®, clay or 3M'"2-Component Foam Independent 171 159 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume®, clay or 3M"2-Component Foam Independent 177 1fi5 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 TAeLE 113: PERFORMANCE LIMITATIONS -HVHZ,INTERUEPENDENT PADDY PLACEMENT '(4 TO I MARGIN OFSAFETYA_L_READYAPPOED) Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based M, (ft-lbf) F' (Ibf) Trim Lock or Trim galvanized, Galvalume®, clay or 3M"2-Component Foam Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Interdependent 95 88 Trim Lock galvanized, Galvalume•, clay or 3M1" Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 Trim Lock aluminum clay or 3M'" Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim Lock Plus galvanized, Galvalume•, clay or 3M•" Foam RoofTle Interdependent 90 84 aluminum or stainless steel concrete Adhesive RTA-1 Trim Lock galvanized, Galvalume®or clayor TILE BOND"' Roof Tile Interdependent 123 117 stainless steel concrete Adhesive ' clay or TILE BOND"' RoofTle Trim Lock aluminum concrete Adhesive Interdependent 79 73 Trim Lock Plus galvanized, Galvalume®, clay or TILE BOND"' Roof Tile Interdependent 79 73 aluminum or stainless steel concrete Adhesive Trim Lock galvanized, Galvalume®or clay or Touch'n Seal Storm Bond Interdependent 146 239 stainless steel concrete RoofTile Adhesive Trim Lock Aluminum clay or Touch'n Seal StarmBond Interdependent 58 54 concrete Roof Tile Adhesive Trim Lock Plus galvanized, Galvalume°, clay or Touch'n Seal StormBond Interdependent 58 54 aluminum or stainless steel concrete Roof Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E10240.68.08-114 Certificate of Aathorizatiaa 49503 FL5374-114 Revision 4: 03/17/201S Page 4 of 7 �l I KINITY ERD 5.3 FOR NON-HVHZ JURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturers published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE2.A: PERFORMANCE LIMITATIONS—NON-HVHZ; INDEPENDENT PADDY PLACEMENT (1 TO 1_ MARGIN OFSAFETYALREADYAPPNED). Hip/Ridge Metal Tile Adhesive Allowable Uplift (psf) Design Metal Type Type Placement Hip & Ridge galvanized clay or 3M'" 2-Component Foam Roof Independent 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume®, aluminum or clay or 310 ' 2-Component Foam Roof Independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanlzed, Galvalume•, aluminum or clay or 3M'" 2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 TABLE2B: PERFORMANCE LIMITATIONS—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT _ (4To 3 NIARGINOFSAFETYALH_EADYAPAUEOj Hip/Ridge Metal Tile Adhesive Allowable Uplift (psf) Design Metal Type Type Placement Trim Lock or Trim galvanized, Galvalume®, aluminum or clay or 3M" 2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trim Lock galvanized, Galvalume® or stainless clay or 3M'" Foam Roof Tile Adhesive Interdependent 110 steel concrete RTA-1 Trim Lock aluminum clay or 3M'" Foam Roof Tile Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalume®, aluminum or clay or 3M"' Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized, Galvalume' or stainless clay or TILE BOND- Roof Tile Adhesive Interdependent 152 steel concrete clay or Trim Lock aluminum TILE BOND'" Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized, Galvalume°, aluminum or clay or TILE BOND"' Roof Tile Adhesive Interdependent 82 stainless steel concrete galvanized, Galvalume® or stainless clay or Touch'n Seal StormBond Roof Trim Lock steel concrete Tile Adhesive Interdependent 148 clay or Touch'n Seal StormBond Roof Trim Lock Aluminum concrete Tile Adhesive Interdependent fit Trim Lock Plus galvanized, Galvalume®, aluminum or clay or Touch'n Seal Storm Bond Roof Interdependent fit stainless steel concrete Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E30240.08.08-R4 Certificate of Authorbation 49503 FL5374-R4 Revision 4: 03/17/2015 Page 5 of 7 �I I KINrry I ERD 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned''/. -inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placementof the ridge tiles. 6.3.2 ApptoVed UI1d2flByments are the codifed'30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile adhesive EXterlor Research and Design, LLC. CertlJltate ofAuthorbation W9503 Evaluation Report E102A0.05;7 - Revision 4Opage 6 of 7 �I I KINITY ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACrURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc.—QUA1844; (717) 764-7700 END OF EVALUATION REPORT - Exterior Research and Design, U.C. certificate ofAuthorizorion #9503 Evaluation Report E10240.08.08-R4 FL5374-R4 Revision 4: 03/17/2015 Page 7 of 7