HomeMy WebLinkAboutEvaluation ReportTRINITY I ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT 13
OXFORD, CT 06478
(203)262-9245
ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R8
12505 NW 44th Street FL6332-RB
Coral Springs, FL 33065 Date of Issuance: 08/08/2008
(888) 774-1419 Revision 8:10/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6" Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The fa s mile seal appearing was authorized by Robert
Nieminen, P.E. on 10/12/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
VTRINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 6`h Edition (2017) Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Sections
Property
Standard
Year
1504.2.1.1
Overturning resistance
SSTD 11
1997
3. REFERENCES:
gaint
Examination
Reference
Date
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.02.12
02/20/2012
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.11.13-R1
01/02/2015
ICC-ES (EVL2396)
20121BC Compliance
ESR-1709
12/01/2016
Miami -Dade (CER 1592)
HVHZ compliance
17-0322.03
04/27/2017
PRI (TST5878)
Static Uplift —SSTD 11
ECM-001-02-01
09/21/2001
PRI(TST5878)
Static Uplift —SSTD 11
PFI-006-02-01
05/09/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-006-02-02
05/09/2005
PRI (TST5878)
Static Uplift —SSTD 11
PFI-007-02-01
10/11/2005
PRI (TST5878)
Static Uplift —SSTD 11
PFI-008-02-04
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-009-02-03
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift—SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST5878)
Static Uplift—SSTD 11
PFPI-010-02-01
12/07/2006
PRI (TST5878)
Static Uplift —SSTD 11
PFPI-011-02-01
12/07/2006
PRI (TST5878)
Static Uplift —SSTD 11
PFPI-012-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-013-02-01
12/07/2006
PRI (TST 5878)
Static Uplift—SSTD 11
PFPI-014-02-01
12/07/2006
PRI (TST 5878)
Static Uplift—SSTD 11
ECM-003-02-01
06/13/2008
PRI (TST 5878)
Static Uplift—SSTD 11
ECM-004-02-01
06/13/2008
PRI(TST5878)
Static Uplift —SSTD 11
ECM-005-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD it
ECM-006-02-01
06/13/2008
PRI(TST5878)
Static Uplift —SSTD 11
ECM-007-02-01
06/13/2008
PRI (TST5878)
Static Uplift—SSTD 11
ECM-008-02-01
06/13/2008
UL LLC(QUA 9625)
Quality Assurance
Service Confirmation
Exp.06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders (ICP Adhesives PrOPackO 30 & 100).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certificate ofAuthoriration #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset° AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 2 of 9
�l I KINITY ERD
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives
Polyset® AH-160.
5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to
projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables
2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment
values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for
Adhesive Paddy Placement details.
TABLE I: FIELD TILES IN ICP ADHESIVES POLVSET®AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
2 TOl MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (SINGLE OR EOWINUOUSPADDY) PLAEEMEW
4 TO Z WRONOFSAFEWALREADYAPPOEU FOR IWEROEPENOEM(TWO PADDY) PMCEMEW
Tile (FBC 1609.5.3)
Adhesive Paddy Placement
Allowable
overturning
Type
Profile
Moment (ft-lbf)
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
60
Clay or
Flat
Independent; Single Paddy, Large (2%10-inch, -45 gram)
112
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at file overlap)
54
Independent; Single Paddy, Medium (2x7-inch, ^30 gram)
39
Clay or
Low/
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
Concrete
Medium
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap)
58
Clay
High
Independent; Single Paddy, Large (240-inch, -45 gram)
134
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
65
Concrete Clay
High
Independent; Single Paddy, Large (2x10-inch, -63 gram)
109
Interdependent; Two Paddy (44-Inch on underlayment, 2x4-inch at the overlap)
40
Clay
Barrel
2x10-inch x -35 gram for pans; 2 @ 1x10-inch x-17 gram for cap
147
Concrete
Barrel
2x10-inch x -35 gram for pans; 2 @ 1x10-inch x `17 gram for cap
107
Clay
Cap atop 2x
Independent: Continuous Paddy ("34 gram/ft)
135
stringer
Concrete
Cap atop 2x
Independent: Continuous Paddy (- 34 gram/ft)
116
stringer
ClayCap
atop 2x
Interdependent:
105
stringer
Head: One (1) #10 x 2'k" screw; Overlap: 1 x 6 inch (" 50.5 gram)
Concrete
Cap atop 2x
Interdependent:
76
stringer
Head: One (1) #10 x 2W screw; Overlap: 1 x 6 inch (-10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Polyset® AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certificate of Authorization R9503 6D' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB
ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 3 of 9
v I KINITY ERD
5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 3A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLysETO AH-16O
ALLOWABLE'UPLIFr RESISTANCE PERFORMANCE DATA
3 TO I MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY) PLACEMENT
4 TO MARGIN OFSAFEFYALREADYAPPDED FOR INTERDEPENDENT PLACEMENT
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (^34 gram/ft)
116
Concrete
2X PT ridge board
Independent: Continuous Paddy(- 34 gram/ft)
107
Clay
2x PT ridge board
Interdependent: Head: One (1) #10 x 2%" screw;
90
Overlap: 1 x 6 inch ("'10.5 gram)
Concrete
2x PT ridge board
Interdependent: Head: One (1) #10 x 2'/:" screw;
Sfi
Overlap: 1 x 6 inch (^'30.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Independent: Continuous Paddy (^34 gram/ft)
169
Concrete
galvanized only
Clay or
Trim Lock" (FL5374): aluminum,
Independent: Continuous Paddy ("34 gram/ft)
173
Concrete
galvanized, GolvalumeO or stainless steel
Clay or
Trim Lack— Plus (FL5374): aluminum,
Independent: Continuous Paddy ("'34 gram/ft)
178
Concrete
galvanized, Galvalume® orstainless steel
Clay
Top Notch (FL8095)
Independent: Continuous Paddy (^ 32 gram/ft)
125
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy (^' 32 gram/ft)
146
6. INSTALLATION:
6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section S.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
S. MANUFACTURING PLANTS:
Tomball, TX
9. QUALITY ASSURANCE ENTITY:
UL, LLC.—QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RB
Certificate OfAutharization H9503 6� EDITION(20171 FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774.1419 Revision 8:10/12/2017
Page 4 of 9
�I I KINITY I ERD
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE):
10.1 Independent, Medium Paddy:
Nail through plastic cement Paddy (Beneath rile)
(when requi:c,
Unc dayerent
o
It 7in.
Battens option al °
Eave Course +�}
a
10 in.
Fascia
2in
Eave Closure
Flat/Low Profile Tile
Nall through plastic cement
(when required)
Paddy (Beneath rile)
Underlayment
71n.. In.
�`•,`..
Battens optional`'
loin.
21n.
Eave Closure
Eave Course
Fazcla
Medium Profile Tile
Nail through plastic ce
(when required) Paddy (Beneath Tile)
Underlayment
7In.. In.
Battens optional
EaveCourse Fascia
We iphole
to in tin: Eaveclosure
Drip edge
High Profile Tile
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certificate of Authorization#9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyseta AH-160; (898) 774.1419 Revision 8: 10/12/2017
Page 5 of 9
10.2 Independent, Large Paddy:
Underlayment
1 41
0 in\
Battens optional �'Y °
Eave Course
0
e �r�y~'K"j,
10inf
Flat/Low Profile Tile
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
" I KIIVITi ERD
Nall through plasticcement
(when required)
Paddy (Beneath7ilel
Underlayment
2in.wide
Battensoptldnal
010 in. `�2in.
Eave Closure
Eave Course Fascia
Medium Profile Tile
Nail through plasticce
(when required) Paddy(BeneathTile)
Underlayment
`IIIY
10 in.x
2 in.wide
Battens
optlonal IV
Eave sr+«
mot,
Eave Course Fascia
Vleephale
10 in tin Eave closure
Drip edge
High Profile Tile
fiTM EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polysete AH-160; (888) 774-1419
Evaluation Report 02768.03.06-R8
FL6332-R8
Revision 8: 10/12/2017
Page 6 of 9
10.3 Interdependent, Two Paddy:
Nail through plastic cement Paddy (between tiles)
(when required)
Battens option al °
o Paddy (under tile))
( Single paddy
ontopoftile
l r
4z4in.
Singleif
under til
Singie paddy
on uifderlaymen[ 2 2x 4in.
0
° N.
10in.
i i n.
2Fasca
2
Eave Closure
Flat/Low Profile Tile
Exterior Research and Design, U.C.
Certificate of Authorization #9503
�I TRINITY ERD
Nall through plastic cement Single paddy under tile
(when required)
Paddy(between tiles)
Battens Paddy (under tile)
(optional
Single paddy
��..on top of slle\
�4 x4in.
2%41 .�i
Single paddy on `4ti
undedayment -
10in. tin.
Eave closure
Eave Course Fascia
Medium Profile Tile
Nail It It pI sticce
Single paddy undertile
(when required)
Paddy (between tiles)
Battens
optional E
Paddy (under tile)
fyj
��Singlepaddy
an underiaymen[
ice!
4 x4 in.
Single 2%4in.
paddyon
top of No
/� Eave Course
Fascia
weephole
Eaveclosure
�P
Drlp edge
High ProffleTile
6' EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyseta AH-160; (888) 774-1419
Evaluation Report 02768.03.06-R8
FL6332-RS
Revision 8: 10/12/2017
Page 7 of 9
�I I KINIIY J ERD
10.4 Two Piece Barrel (Cap & Pan) Tile:
1) Pfau enough adhesive to achieve 6s to
In contest with the pan tile.
2) Tum CoversupaWe down. Place aabealvs
is In. is 1 Inch In fmm cutdao caps of cover)
Inswilrosques.
En sum 20 G 25 sq. in, contact ama s�
seen ala�mwaerme.
IUnderlayment
(motar shown)
f the eave worse cover file. Abut to second worse of
end of pan and save r111as are Bush at ease fine.
Two. Piece Barrel - High Profile Tile
10.5 Hip and Ridge (independent placement):
TO abaeh hyhiaPse to s, a bead o[ICPPolysetbAH•!60 may
be applied darn the c®terufew Wpledu_e bond or gnhtaired
flares -
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB
Certificate of Authorization N9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polysete AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 8 of 9
10.6
Hip and Ridge (interdependent placement):
END OF EVALUATION REPORT -
�I TRINITY ERD
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certificate of Authorization#9503 6n`EDITION (2017)FBC NON-HVHZ EVALUATION FL6332-RB
ICP Adhesives Polyset® AH-160; (8881 774-1419 Revision 8: 10/12/2017
Page 9 of 9
ltli'
�
Professional Regulation
Floridap
*Product Approval
n USErt: public User
61m
EMdUc pproval Menu > ELRAVgt or Application Search > Applica[lon Lls[> Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5374-RS
Affirmation
2017
Approved
East Coast Metals, Inc.
2301 West 8 Lane
Hialeah, FL 33010
(305) 885-9991
acastellanos@eastcoast-metals.com
Tom Castellanos
acastellanos@eastcoast-metals.com
Tom Castellanos
2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
tcastellanos@eastcoast-metals.com
Howard Callender Jr.
2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
hcallender@eastcoast-metals.com
Roofing
Roofing Accessories that are an Integral Part of the Roofing System
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
O Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
Architectural Testing, Inc., an Intertek Company
12/31/2020
John W. Knezevich, PE
O Validation Checklist - Hardcopy Received
FL5374 R5 COI 2015 01 COI Nleminen.Rd(
Standard
Year
FRSA/TRI April 2012 (04-12)
2012
RAS 118
1995
RAS 119
1995
PAS 120
1995
SBCCI SSTD 11
1997
TAS 101
1995
Equivalence of Product Standards
Certified By
1
Sections from the Code
G I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity 0 yes 0 No 0 N/A
FL5374 R5 CDC 2017 09 AFFIRMATION ECM FL5374 6th Edition
.(2017)ypdf
Product Approval Method Method 1 Option D
Date Submitted 09/06/2017
Date Validated 09/06/2017
Date Pending FBC Approval
Date Approved 09/10/2017
Summary of Products
FL #
Model, Number or Name
Description -
5374.1
East Coast Metals Channel Metals
Preformed metal channels designed for use as a hip & ridge
base to which roof tiles are bonded.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5374 R5 II 2015 03 FINAL ER ECM Trim Lock F1_5374-
R4.12df
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-178
Created by Independent Third Party: Yes
Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 for
Evaluation Reports
Limits of Use In HVHZ and non-HVHZ jurisdictions, respectively.
FL5374 RS AE 2015 03 FINAL ER ECM Trim Lock FL5374-
R4.od
2.) The design pressure herein pertains to use in non-HVHZ
jurisdictions in conjunction with Table IA of FRSA/TRI April
Created by Independent Third Party: Yes
2012 (04-12). Refer to Tables 2A and 2B in the Evaluation
Report for all options and associated allowable design
pressures.
Back Next
Contact, Us :: 2601 Blair Stone Road, Tallahassee R 32399 Phone: 850-487-1824
The state of Florida is an AA/EEO employer. Coht 2007-2013 State of Florida :: Privacy Statement :: AccessiblIty Statement :: Refund Statement
Under Florida law, email addresses are public remrds. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to Nis entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 45S.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here
Product Approval Accepts:
®® M N
securkpitSrlkics•
TRINITY ERD
EVALUATION REPORT
East Coast Metals, Inc.
2301 West 8 Lane
Hialeah, FL 33010
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report E10240.08.08-R4
FL5374-R4
Date of Issuance:09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: .
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The Facsimile seal appearing was authorbed by Robert Nieminen,
P.E. on 03/17/1015. This does not serve as an elsevoNeally signed
document Signed, sealed hardcopies hive been tmsnmoed tothe
Product Approval Administrator and to the named dent
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�/ TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118,119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1711.2.1
Static Uplift Resistance
SEW SSTD 11
1997
3. REFERENCES:
gaiity
Examination
Reference
Date
ERD (TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-1
02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-2
02/27/2015
Florida TEC(T517393)
TAS 101
S10-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI(TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI(TST5878) -
TAS 101
ECM-008-02-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/rRI April 2012(04-12)
04/2012
Florida Building Code - HVHZ
Attachment Requirements
RAS 118,119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 Or 7-inch L 3/8-inch)
heights with 1.5-inch L 1/16-inch) deck -Flanges.
Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4
CertiJrcate ofAuthorlsation N950 FL5374-R4
Revision 4: 03/17/2015
Page 2 of 7
NINITY ERD
4.2 Trim Lack Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (± 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights
with 1.5-inch it 1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032±0.002-inch, ASTM 13209, 3003-H14, min. 21 KSI.
➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nleminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4
Certgicate ofAuthorhation 119503 FL5374-R4
Revision 4: 03/17/2015
Page 3 of 7
VTRINrry I ERD
5.2 FOR HVHZJURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables 1A and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLEIA: PERFORMANCE LIMrrATuJNS-HVHZ, INDEPENDENT PADDY PLACEMENT
_ f2 TO MARGIN OFSAFEIYALREADYAPPNEDj
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
Mt(ft-Ihf)
F'(Ibf)
Hip &Ridge
galvanized
clay or
3M'"2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalumea,
clay or
3M'"2-Component Foam
Independent
171
159
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®,
clay or
3M'"2-Component Foam
Independent
177
165
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
TABLE IB: PERFORMANCE LIMITATIONS - HVHZ, INTERDEPENDENT PADDY PLACEMENT
_ f4TO1 MARGIN OFSAFET'AL_READYAPPUEDj
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
Mr(ft-Ihf)
F'(Ihf)
Trim Lock or Trim
galvanized, GalvalumeO,
clay or
3M'"2-Component Foam
Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume•,
clay or
3M'" Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
clay or
3M'" Foam Roof Tile
Trim Lock
aluminum
concrete
Adhesive RTA-1
Interdependent
90
84
Trim Lock Plus
galvanized, Galvalumet',
clay or
3Mm Foam Roof Tile
Interdependent
90
84
aluminum or stainless steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume°or
clay or
TILE BOND'" Roof Tile
Interdependent
123
117
stainless steel
concrete
Adhesive
Trim Lock
aluminum
clay or
TILE BOND'" Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume•,
clay or
TILE BOND'" Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume• or
clay or
Touch'n Seal Storm Bond
Interdependent
146
139
stainless steel
concrete
Roof Tile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
galvanized, Galvalume•,
I clay or
Touch 'in Seal Storm Bond
Trim Lock Plus
aluminum or stainless steel
concrete
RoofTile Adhesive
Interdependent
58
54
Exterior Research and Design, L-C. Evaluation Report E10240.08.08-R4
Certicate of Authorization #9503 FL5374-114
Revision 4: 03/17/2015
Page 4 of 7
�1 1 KINITY ERD
5.3 FOR NON-HVHZJURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructionsfor adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bands the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 2A: PERFORMANCE LIMLTAniiNS-NON-HVHZ, INDEPENDENT. PADDY PLACEMENT
(2 To MARGIN OF SAFETYALREADYAPPLIEOJ
Hip/Ridge Metal
Tile
Adhesive
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Placement
Hip &Ridge
galvanized
clay or
3M-2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°, aluminum or
clay or
3M-2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clayor
3M-2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
TABLE_2B: PERFORMANCE LIMiTATIONs-NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4 TO MARGIN 0F9 FETYMREAOYAPPNEO) _
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(psf)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume®, aluminum or
day or
3M'" 2-Component Foam Roof
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Interdependent
98
galvanized, Galvalume• or stainless
clay or
3M`" Foam Roof Tile Adhesive
Trim Lock
steel
concrete
RTA-1
Interdependent
110
clay or
3M- Foam Roof Tile Adhesive
Trim Lock
aluminum
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume•, aluminum or
clay or
3M- Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume' or stainless
clay or
TILE BOND- RoofTile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
Trim Lock
galvanized, Galvalume® orstainless
clay or
Touch'n Seal StormBond Roof
Interdependent
148
steel
concrete
Tile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
galvanized, Galvalume-, aluminum or
clayor
Touch'n Seal Storm Bond Roof
Interdependent
fit
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E30240.08.08-R4
certificate o)Authorizatlon N9503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
VTRINITYIERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. it ga. x N-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RA5118, Drawing 13, Detail 3; RA5119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It Is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design, LLG Evaluation Report E30240.08.08-R4
CeAiifwte o)Authoruation #9503 FL5374-114
Revision 4: 03/17/201S
Page 6 of 7
�l I KINITY ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturers Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other band -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACrURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc.—QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
Certifimte oJAuthorGotlon p950 FL5374-R4
Revision 4:03/17/2015
Page 7 of 7
1
\I I KINITY ERD
EVALUATION REPORT
East Coast Metals, Inc.
2301 West 8 Lane
Hialeah, FL 33010
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report E10240.08.08-R4
FL5374-R4
Date of Issuance:09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the Sin Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEcnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The fzaimile seal appearing svasauthorhed by Robert Meminen,
P.E. on 03/17/2015. This does notserveas an eleNonicallysigned
document Signed, sealed hardccpies have been trznsmitted to the
Product Approval Administrator and to the named dent
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
VTRINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118, 119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TA5101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
9afint
Examination
Reference
Date
ERD (TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD (TST6G49)
Static Uplift Resistance
ECM-SC6795.12.14-1
- 02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-2
02/27/2015
Florida TEC (TST7393)
TAS 101
510-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-004-02-01
O6/13/2008
PRI (TST5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI (TST5878)
TAS101
ECM-008-02-01
06/13/2008
Florida Building Cade
Attachment Requirements
FRSA/TRI April 2012 (04-12)
04/2012
Florida Building Code -HVHZ
Attachment Requirements
RA5118, 119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch)
heights with 1.5-inch (±1/16-inch) deck -flanges. '
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
Certificate oJAuthodrotlon #9503 F .5374-R4
Revision 4: 03/17/2015
Page 2 of 7
VTRINITYIERD
4.2 Trim Lack Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch L 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(± 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 K51.
➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032±0,002-inch, ASTM B209, 3003-1-114, min. 21 K51.
➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4
Certiflcote olAuthorization #950 FL5374-114
Revision 4: 03/17/2015
Page 3 of 7
VTRINITYIERD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip &.Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables SA and SB is supplemental to these prescriptive allowances.
Installations of Trim Lack Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is banded to the Channel Metal in its own, single
foam paddy, the head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance. - I
TABLEIA: PERFORMANCE LIMITATIONS- HVHZ, INDEPENDENT PADDY PLACEMENT
_ _ (2.T01 MARG)NOFSAFETYA_LREAOYAPP0ED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
M,(ft-lbf)
F'(Ibf)
Hip &Ridge
galvanized
clay or
3M'"2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume®,
clay or
3M'"2-Component Foam
Independent
171
159
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®,
clay or
3M"2-Component Foam
Independent
177
1fi5
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
TAeLE 113: PERFORMANCE LIMITATIONS -HVHZ,INTERUEPENDENT PADDY PLACEMENT
'(4 TO I MARGIN OFSAFETYA_L_READYAPPOED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
M, (ft-lbf)
F' (Ibf)
Trim Lock or Trim
galvanized, Galvalume®,
clay or
3M"2-Component Foam
Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume•,
clay or
3M1" Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M'" Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume•,
clay or
3M•" Foam RoofTle
Interdependent
90
84
aluminum or stainless steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume®or
clayor
TILE BOND"' Roof Tile
Interdependent
123
117
stainless steel
concrete
Adhesive
'
clay or
TILE BOND"' RoofTle
Trim Lock
aluminum
concrete
Adhesive
Interdependent
79
73
Trim Lock Plus
galvanized, Galvalume®,
clay or
TILE BOND"' Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume®or
clay or
Touch'n Seal Storm Bond
Interdependent
146
239
stainless steel
concrete
RoofTile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StarmBond
Interdependent
58
54
concrete
Roof Tile Adhesive
Trim Lock Plus
galvanized, Galvalume°,
clay or
Touch'n Seal StormBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.68.08-114
Certificate of Aathorizatiaa 49503 FL5374-114
Revision 4: 03/17/201S
Page 4 of 7
�l I KINITY ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturers published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE2.A: PERFORMANCE LIMITATIONS—NON-HVHZ; INDEPENDENT PADDY PLACEMENT
(1 TO 1_ MARGIN OFSAFETYALREADYAPPNED).
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(psf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
clay or
3M'" 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume®, aluminum or
clay or
310 ' 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanlzed, Galvalume•, aluminum or
clay or
3M'" 2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
TABLE2B: PERFORMANCE LIMITATIONS—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT
_ (4To 3 NIARGINOFSAFETYALH_EADYAPAUEOj
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(psf)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume®, aluminum or
clay or
3M" 2-Component Foam Roof
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Interdependent
98
Trim Lock
galvanized, Galvalume® or stainless
clay or
3M'" Foam Roof Tile Adhesive
Interdependent
110
steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M'" Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
3M"' Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume' or stainless
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
152
steel
concrete
clay or
Trim Lock
aluminum
TILE BOND'" Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
TILE BOND"' Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
galvanized, Galvalume® or stainless
clay or
Touch'n Seal StormBond Roof
Trim Lock
steel
concrete
Tile Adhesive
Interdependent
148
clay or
Touch'n Seal StormBond Roof
Trim Lock
Aluminum
concrete
Tile Adhesive
Interdependent
fit
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
Touch'n Seal Storm Bond Roof
Interdependent
fit
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E30240.08.08-R4
Certificate of Authorbation 49503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
�I I KINrry I ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned''/. -inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placementof the ridge tiles.
6.3.2 ApptoVed UI1d2flByments are the codifed'30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive
EXterlor Research and Design, LLC.
CertlJltate ofAuthorbation W9503
Evaluation Report E102A0.05;7 -
Revision 4Opage 6 of 7
�I I KINITY ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACrURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc.—QUA1844; (717) 764-7700
END OF EVALUATION REPORT -
Exterior Research and Design, U.C.
certificate ofAuthorizorion #9503
Evaluation Report E10240.08.08-R4
FL5374-R4
Revision 4: 03/17/2015
Page 7 of 7