Project Information
Project Summary Date: Jan 28, 2020 - wrightsoftAHU 2 BY: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-486-8799 Fax 772466-6796 Emall: QUICKCALCS@AOL.COM Project• • For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORT ST LUCIE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 5999 Btuh Structure 10170 Btuh Ducts 1982 Btuh Ducts 2808 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 7981 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf load 0.95 12329 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2711 Btuh Ducts 740 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) 3451 Btuh Area (ft� 73 738 Equipment latent load Volume (fts) 7454 7454 Airchanges/hour 0.33 0.18 Equipment Total Load (Sen+Lat) 15780 Btuh Equiv. AVF (cfm) 41 22 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NW01800GOA0 AHRI ref Coil FX4DNF019L AHRI ref 9200856 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 2.9 kW Sensible cooling 12390 Btuh Heating output 9727 Btuh Latent cooling 5310 Btuh Temperature rise 15 OF Total cooling 17700 Btuh Actual air flow 590 cfm Actual air flow 590 cfm Air flow factor 0.074 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ -rl*- wrrghTsofftt- 2020-Jan-28 13:25:53 Right -Suite® Universal 201919.0.08 RSU08101 Page 1 44CCA EADocunmetsMdghtsoft WACIROAF RESIDENCE.rup Calc = MJ8 Front Door faces: N wrightsoft• Project Summary Date: Jan 28, 2020 AHU 3 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Faz 772-46&6796 Email: OUCKCALCS@AOL.COM Project• • For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORT ST LUCIE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11236 Btuh Structure 13609 Btuh Ducts 2909 Btuh Ducts 4216 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14145 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 16933 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2903,Btuh Ducts 1108 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft� 1161 1161 Equipment latent load 4011 Btuh Volume (fts) 11470 11470 Air changesthour 0.37 0.20 Equipment Total Load (Sen+Lat) 20944 Btuh Equiv. AVF (cfm) 72 38 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NW02400GOA0 AHRI ref Coil FX4DNF037L I ref 9201326 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.7 kW Sensible cooling 16660 Btuh Heating output 12792 Btuh Latent cooling 7140 Btuh Temperature rise 15 OF Total cooling 23800 Btuh Actual airflow 793 cfm Actual airflow 793 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ wrrgh�sGft' 2020-Jan-2813:25:53 Right -Suite® Unhzrsal 2019 19.0.08 RSU08101 Page 2 E:\DocumnetslWrIghtsoft WAC\ROAF RESIDENCE.rup Cale =MJS Front Door faces: N Project Summary Da e: Jan 28, 2020 A �+ wrightsoft HU1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS ,AOL.COM Project• • For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORT ST LUCIE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10548 Btuh Structure 18677 Btuh Ducts 5676 Btuh Ducts 8119 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh slower 0 Btuh Piping 0 Btuh Equipment load 16224 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf load 0.95 25457 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3299 Btuh Ducts 2279 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft� 1742 1742 Equipment latent load 5579 Btuh Volume (fts) 17589 17589 Airchanges/hour 0.20 0.11 Equipment Total Load (Sen+Lat) 31035 Btuh Equiv. AVF (cfm) 58 31 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03700GOBO AHRI ref Coil FX4DNF037L AHRI ref 202024448 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 3.6 kW Sensible cooling 24640 Btuh Heating output 12416 Btuh Latent cooling 10560 Btuh Temperature rise 10 OF Total cooling 35200 Btuh Actual air flow 1173 cfm Actual air flow 1173 cfm Air flow factor 0.072 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -rk wrrgt2 soft- 2020Jan-2813:25:53 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 3 :Mccurnnet Mrlghlsolt HVAC\ROAF RESIDENCE.rup Calc=MJ8 Front Door faces: N wrightsoft' Right-M) Worksheet Job: AHU 2 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-468-6799 Fac 772-086-6796 Emil: QUICKCALCS@40LCOM 1 Room name AHU 2 M TOILET 2 6yosed wall 920 It 0 it 3 Room height 10.1 ft 10.1 ft heat/cool 4 Room dimensions 7.0 x 6.0 It 5 Room area 738.0 11' 420 ft' Ty Construction number U-,.slue (Btuh/ft?°F) Or HTM (Btul✓m Area (ft') or perimeter (ft) Load (Btuh) Area ((t� or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 lllggqJJJ 131 -7 5fcs - - 2 glaze Gr low-e - 0.083 0.650 0.650 n n 2 32 0.00 10 20 1.10 4:99 14.99 0.00 d 62 8 '0 0 � 0 0 _ - 146 14fi -0 +. 120 120 0 .0 0 0 _ _ , Q 0 0 .__. U 10 0 _ ..0 0 0 11 2 glazing, clr lave 2 glazing; clr lave _ Q650 u n . - . 0.00 0.00 0 � 0 0 , 0 0 --a 0 -__ 0---. 0 0 r0 0 0 0 0 _ 0 _ 2 glazing, or lave 2 gluing, 2 glazing, Ur lave 0.653 0.083 0.650 a a a 12.32 8.20 18.20 31.10 0.39 30.39 515 5 5 481 1 1 1191 91 97 537 152 162 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr lov-e 2 glazing, clr lore 0.650 0.650 a a 0.00 18.20 0.00 3265 0 18 0 1 0 328 0 588 0 0 0 0 0 0 0 0 I - ` G 13A-7.5fcs 2 gluing, Gr lc tie 13A-7.5fcs _ ad83 0.650 0.083 se se s _0 _0-0 - Ago 232 0.00 , , :0.00 1.10 . _ .0 0 152 __ 0 0 92 0 0 213 0 -.0 101 - -0 0 0 _ - 0 0 0 0 _ 0 0 0 `_. ,0 0 I---G 2 glazing, clr lave 2 glazing, clr to -e 0.650 0.650 s s 0 .020 18. 0.00 0 14.99 0 36 0 36 0 65 0 540 0 0 0 0 0 0 0 0 III------GGG 2 glazing, or lox a 2 Razlnq, clr love 13A-7 0.650 0.650 - - 0.650 s s w 18.20 _ 000 _ 232 14.99 0.00 1.10 24 _ 0 10a 24 0_ 80 437 _ _ 0___ - 185 360 __ 0 88 0 0 0 0 0 0 0 0 0 0 0 0 '2 glazing,ng, clr lave 2 glazing, cir lose 2 glazing, clrlav-e 0.650 .650 00.650 w w w 0 00 0.00 000 0.00 0 0.00 a 0 0 0 0 0 0 0 g 0 0 � 0 0 000 0 0 0 0 0 0 0- '0 0 '0 2 glazing, ctr lave - 0.650 _ w ._ 18.20 32.93 _ 21 _ 1 _ . 388 _ .702 0 _ . 0 _ 0 .0 C 16D-30td 0.032 0.90 0.96 720 720 645 6_9.1 41 41 37 3.9 1.358 a _ 38.02 0.00 .:15 -- -- 2 _ 74 0 0 _ 0 _ � 0 0 6 c)AED excursion 0 0 Eaelope loss/gain 4747 4211 37 39 12 a) Infiltration 1252 359 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 5600 750 Subtotal Qines 6to 13) 5999 10170 37 789 Less edertal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 4 4 14 Subtotal 5999 10170 41 794 15 Duct loads 33% 28% 19a2 28os 33% 28% 14 219 Total room Icad 1 7981 1 12978 54 1013 Air required (cfm) 590 590 4 46 J. Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ T wrl9ti�o- 2020.Jan-2813:25:53 Right -Suite® Universal 201919.0.08 RSU08101 Page 1 ��EADocunmelslWrightsoft WAMROAF RESIDENCE.rup Cale =MJ6 Front Door faces: N �+wrightsofC Right-M Worksheet Job: AHU 2 Date: Jan 28, 2D20 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M HALL M WIC 2 2 Eiposed wall 0 ft 0 It 3 Room height 10.1 ft heal/cool 10.1 If heat/ccol 4 Room dimensions 4,0 x 5.0 ft 7.0 x 8.0 ft 5 Room area 20.0 fN 56.0 W Ty Construction U-value Or HTM Area (ft� Lead Area Load number (BtutVftk'F) (Btuhrft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross I N/P/S Heat Cool 8 wIII�--^,'�. 1 7 f_-. 1:10 - - - 0 �- 0 0 0 ' -0 0 0 2 glazing; drlav-e 0.850 n 1820 4.00 10.00 0 0 0 0 0 0 0 0 0 2glazing 'clr lcr a 0.650 n 020 � 00 '0.99 0 0 0 0 0 0 0 0 I--G 2 lazin dr low a 0.650 n 0 00 0 0 0 0 0 0 0 0 11 II--_--'GG clr Im-e 2. glazing, _ _0.650 n. _ 0.00 '0 0 ._ _ . 0 _-_ _0 ...0 _ _. 0 .. 0 - _ .. 0 0,653 a 232 0 0 0 0 0 0 0 0 2 glazing, clr Iav-e 2filming, 0.650 a 18.20 0.39 30.39 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.650 a 18.20 30.39 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 0.00 0.00 a 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.650 e 18.20 32.65 0 0 0 '- _ _ _ 0 - _ 0 _ _ 0 _ 0 0 VN -� 13A-7.5fcs 0.083 se _ _ OAO 0.00 0 - 0 '0 0 _ 0 0 0 0 �G 2glazigq,.drloxre _0.650 se _ _0.00 0.00 0 0 _ 0 - _ -0 _ 0 0 0 0 0.083 s 0 0 0 0 0 0 0 0 2 glazing, cir lave 2 glazing, 0.650 s 0.00 0.10 0 0 0 0 0 0 0 0 2 glazing, clr lorv-e 0.650 s 8.20 18.20 4.99 14.99 0 0 0 0 0 0 0 0 2 glazing, clr lava 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazinq, clr lave 0.650 s 0.00 0.00 0 0 - _ _0 - 0 - '- - _ ., _0 _ „ 0 0 _ .0 - 13A-7.5fcs .- - --(:083 w ' Z32 1.10 _ a 0 0 0 ',0 0 0 0 IW' _ -2 glazing, cir lo" 0.650 w 000 10.00 0 0 ,0 0 0 0 0 0 2 glazing, orlav-e 0.650 w 000 0.00 0 01 0 0 0 0 .0 0 2 glazing, clr 1o.4-e 0.650 w 0.90 0.00 0 0 0 0 0 0 0 0 2 glazing, orJax-e .0.650 w. 18.20 . 3293 10 - .0 . - _. 0 _ 0 {l 0 0 0 C 16D-3Dtd 0.032 - 0.96 15 15 13 14 48 48 43 - 46 F 2pA-tph -_--- - 1:358 -_ _ _0.90 38.02 0.00 '0 _ -0 ._ _. '0 _ _ .0 .. _ - - --0 _ 0 _ 0 0 6 c)AED excursion 0 0 Envelope loss/gain 13 14 43 46 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 750 Subtotal Oines 6 to 13) 13 14 43 796 Less a demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -13 -14 4 4 14 Subtotal 0 0 47 801 15 Duct loads 33% 28% 0 0 33% 28% 16 221 Taal room load 0 0 63 1022 Air required (cfm) 0 D 5 46 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ wnve-t soo R- 2020-Jan-2813:25:53 RighlSuite® Universal 2019 19.0.08 RSU06101 Page 2 E:\Dwumets\W4ghtsoftHVAC\ROAFRESIDENCE.mp Calc=MJB Front Doorfaces: N op m O 0 e• mA W N 0 +' 0 mAWN+ 1g _ C$ O^ww �ALQ S As 9 o;4)4)4J p 0 4) R `-'om mgm,.'gmmm �,ff n �,o-�-���'��n ffi 6 a � 2'.w,-o.2 Ogg f 1 �C po�oOoo pO�,o po�!0000 qo 00,00p0�' HM00000041041`000041000041'I erg v O ^ 1 • O NO o"81.8+8No oo m N� ^ W O ' OlmNp OWON OWpO�NONNWO ONW NIO p•O O ON o O O O N 0.00 O O O N O 8.S O N' E S y I � O • •O,NO O 000000000'O Oi00NO+fG O'000' 3'^ p O ! b m � _ 1o"N 000 o. o'0000 oo o�oo+om�oOoO o' � s , I x o� i o+m u'm oo0 ie o� �" � � 'o �00000000000 dao�oW�00000. �� �n se I A(O mN000 N S. O+ I. I 00000000000'OONOtWO'00000� WO0'O+OOO+lOYmO N•00'0000 N�00000 yf O O m O t im N(�] fO y"00000' y NA x cm m ' �O yy +f0 S80QQ y A m O(� ' 'y N+f,fZ mn mC�� 0A 3 N A � mW O 0 O ON 0 p� m W m. 0 0 �'0 0� Of0 O 0 0 0 m 0 O A O O�SIN.0 0 0'm 0 0 0 0 0 0 oo o� w Li G 9 to Gr O ii wrlghtsotr Right-J® Worksheet Job: AHU 2 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name M CLST M BATH 2 F)osed wall &0 ft 31.0 It 3 Room height 10.1 It heat/coal 10.1 ft heaticool 4 Room dimensions 4.0 x 6.0 It 1.0 x 2220 ft 5 Room area 24.0 ft- 222-0 ft' Ty Construction U-telue Or HTM Area (ft� Load Area (ftj Load number (BlulfflUF) (BtutVft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heal Cool Gmss N/P/S Heat Cod 6 13A-7 Wf - 0 683 n - 232 110 - 0 - 0 -- 0 _ -0 154 357 - 170 2 glazing clr lave 0650 n 1820 14.99 0 '0 '0 0 8 0 146 '0 120 2 glazing, clr Inv 0650 n 000 0.00 0. 0 0 0 0 0 0 glazing, dr lave 0650 n 000 0.00 0 0 0 0. 0 0 0. 0 11 _ 2glazing, clrlotlre. - 0650 n_ 000 0.00 _ _ .0- _ _ _0.. _ _0 _ --a _._ _0 --------- 0 __. 0 0 0.650 a 2.32 1.39 61 61 740 67 155 141 391 152 2 glazing, cir love 2 gluing, 0.650 a 18.20 30.39 0 0 0 0 5 1 91 152 2 glazing, clr love 0.850 a 18.20 30.39 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 gluing, cir lcxe 0.650 e_ 18.20 3265 0 0 0 _ _ 0 __-0 _ 0 0 0 13A-7.5fcs __. 0.083 ., se 000 '-0.00 .0 0_ _- 0 b 0 _ 0 0 0 2 glazing, Ur lace __ a 650 _ se 0.00 _ 0.00 0 .0 .. -0 , _ a 0.650 s 2.00 1.10 0 0 0 0 0 0 0 0 2 glazing, clr love 2 gluing, 0.650 s 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 s 8.20 18.20 4.99 14.99 0 0 0 0 0 0 0 0 2 glazing, clr law-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr lave_ 0.650 s 0.00 0.00 0 - 0 _0 ___ ,_,0 _ _0 __. _0,__ 0 _ 0 _ W „, 0083 w 232 _ 0 0 0 0 0 0 0 0 2 glazing, clr loa-e 2 gluing, 0650 w 000 0.00 0.00 0 0 0 0 0 0 10 0 2 glazing, clrlarpe 0650 w 000 ,0.00 '0 0 0 0 0 0 0 0 2 glazing, Grlawe 0650 w OOD 0.00 0 0 0 0 0 0 0 0 2glazing..cIrlowe ___0650 w: __.18.20 32-93 .0 .._0 ._ ... 0 .. _ _0 ____._0 __ _ _.0 _ __0 ,0 C 16D-30td 0.96 24 24 22 23 222 222 199 213 -0 F 22A-tph - - -, ,_ - ,0.032 1.358 __, _ - J _0.90 38.02 0.00 .0 0 _. .0-- _ 0 _ _ .. _ 0 ._ _ - - 0 0 6 c)AED emursion 0 1 0 Envelope Ices/gain 162 90 1133 816 12 a) Infiltration 82 23 422 121 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 a Appliances/other 750 1000 Subtotal (liras 6 to 13) 244 863 1555 1937 Less external lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 244 863 1555 1937 15 Duct leads 1 33% 28% 81 238 33% 28% 514 535 Total room lead 325 1102 2069 2472 Air required (cfm) 24 50 153 112 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -4- wrfg.RGso6R- 2020-Jan-2813:25:63 Right -Suite® Uniwmal 201919.0.08 RSW8101 Page 4 EADocunnetslWnghlsofl WAC\ROAF RESIDENCE.mp Cale =MJB Front Door faces: N wrightsoft' Right-M Worksheet Job. AHU 3 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCWOL.COM 1 Room narne AHU 3 CLUB HALL 2 Ei9xised wall 166.2 ft 4.2 it 3 Room height 9.9 it 9.6 ft heaVcool 4 Room dimensions 1.0 x 51.5 ft 5 Room area 1160.5 ft2 51.5 ft2 Ty Cominuctlon U-value Or HTM Area (ft0 Load Am ((l� Load number (Btuh/f k.F) (Btuh/115 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 llpgJJ- 13A-7 5fas'-- -- - - --0 083 -q - - 2 32 '1.10 408 382 888 - 422 � � -- 0 -- - 0 - _ -0 - - -0 F--G 2glazing clr:lo 0650 n 1820 14.99 8 0 146 120 0 0 0 0 2glazing dr lov" 0.650 n 1820 14.99 18 0 328 270 0 0 0 0 III'-------GG 2 glazing, clrwx,l 0.650 n 000 0.00 �0 0 0 0 0 0 0 0 11 2 gluing, dr lmvre , _ 0.650 n _ 000 0.00 -_ 0 _ __0 _- _-.0 - __.0 _a _,_ 0 - '0 _. _ 0 .G 13A-7.5fcs 0.083 a 2.32 1.10 395 386 898 427 0 0 0 0 2 glazing, clr lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr love 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.650 a 18.20 31.52 9 1 164 284 0 0 0 0 2 glazing, clr lave 0.650 a 000 0.00 0 0 --, 0_- -,- 0 , 0 0 _ 0 - 0 -- ltJ 13A-7.5fas -' _ 0.083 se�-232 ,-_1:10 "., 41 20 -47 22 41 '20 47 22 �- 2glazing, olrIa .0.650 se-._ :18.20 23.31 21 . . _-6 _ _ 376 _ --482---- _21 6 376 482 W 13A-7.Sfcs 0.083 s 2.32 1.10 379 206 478 227 0 0 0 0 2 glazing, clr lave 0.650 s 18.20 14.99 45 45 819 675 0 0 0 0 2 glazing, clr Ia 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr tov-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazinq, dr Io 0.650 a 128 128 2330 _ _ 1919 0 _ 0 _ _ 0 _ _ _ 0 __. IW 13A 7.5fm - _ 0 083 w _ _18.20 2.32 , _ _14.99 1.10 413 _ 385 _ _ 894 425 0 'U 0 0 I--C. 2glazing, dr lave 0.650 w 1820 30.39 8 1 146 243 0 0 0 0 � 2 glazing, clr li e 0.650 w' 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr love 0.650 w 18.20 32.42 20 1 364 648 0 0 0 0 Ill-�qG _ 2 glazing, clr lave 0650 .w _000 0.00 _ ._.0 __-o ____0 0 _ ...0 -0 ___-0 C 16D-3Dtd 0.032 0.90 0.96 1161 1_161 1040 1114 ---0 52 52 46 49 F 22A-tpll - - T358 - r _ 38.02 0.00 .16 _ ...,3 _.,. 116 - . , 0 0 0 0 6 c) AED ex:umion 0 121 Envelope toss/gain 9032 7276 469 674 12 a) Infiltration 2204 633 55 16 b) Rminventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 5700 0 Subtotal(lines 6to 13) 11236 13609 524 690 Less eidernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -524 -690 14 Subtotal 11236 13609 0 0 15 Duct loads 1 26% 31% 2909 4216 26% 31% 0 0 Total mom load I 1 14145 1 17825 0 0 Air required (cfm) 793 793 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 4 - wrlghboTe- 2020-Jan-2813:25:53 G:A Right -Suite® Universal 201919.0.08 RSW8101 Page 5 E:\DocumnetslWdghtsoft HVAC\ROAFRESIDENCE.mp Calc=MJB Front Doorfaces: N I�t wrightsott' Right-M) Worksheet Job. AHU 3 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772466-6799 Fac 772466-6796 Email: OUICKCALCS@,AOL.COM 1 Room name BEDROOM 3 LINEN CLST 2 3 Exposed wall Room height 39.0 ft 9.6 ft heat/cool 0 fl 9.6 ft heaNcool 4 5 Room dimensions Room area 1.0 x 198.0 ft 198.0 ft' 20 x 5.0 It 10.0 fP Ty Construction number U-%dw (Btuh/ft-F) Or HTM (Btuhlft� Area (ft' or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Lead (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P!S Heat Cod 6 11 lllggqll! � I---G 13A-75tcs 2glazing, dr love 2 gluing,'Gr laws 2 glazing, clr tco-e 291azing,dr,lwpe _ O.O83 0.650 0.650 0.650 _. 0.650 n n n n _n_ � 232 1820 1820 000 __ 0.00 � 1.10 14.99 14.99 0.00 0.00 -� 0 0 0 0 _ .0 0 0 0 0 _ _ 0 �0 '0 0 0 �- __,0 0 0 0 0 0 0 0 0 '0 ___. __ 0 0 0 0 0 _, 0 - 0 0 0 0 . _ 0 0 0 0 0 0 l((--GG _ 2 glazing, clr lox-e 2 gluing, 2 glazing, Gr tov-e 2 glazing, clr lcry a 2 glazing,. cir lave. _. 13A-7.5fcs 2 glazing, Gr Iw/-e _ 2 glazing, clr lave 2 gluing, 2 glazing, Gr lav-e 2 glazing, dr Iowt 2 gluing, clr lcxe cs 1 glazing, 2 glazing, dr lc a 2 glazing, dr Iox a 2 glazing, dr low-e 0.653 0.650 0.650 0.650 _., 0_650 0.093 _ _0.650 0.083 0.650 0.650 0.650 0.650 - 0.650 0.650 0.650 0.650 a a a a e_. se se s s s s s w w w w 232 0.00 0.00 18.20 __�00 2.32 -18.20 232 10.00 0.00 0.00 18.20 --�i 232 18 20 8.20 �18 20 1.10 0.00 0.00 31.52 0.00 1.10 - 23.31 1.99 14.00 0.00 0.00 14.99 3o 39 30.00 0.00 3242 86 0 0 0 __. a 0 - 0 144 45 0 0 a 140 0 a 0 66 0 0 0 0 0 0 99 45 0 0 0 140 0 0 0 20a 0 0 0 _-. _...0 0 _ 0 810 819 0 0 _ _ 0 330 0 0 0 95 0 0 0 _ ._0 0 .. - _ 0 675 675 0 0 _ __0 150 0 0 0 0 0 0 0 _ _ 0 0 _'0 0 0 0 0 _ - 0 0 '0 0 0 0 0 0 0 _ ._...0 0 - 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 _ _0 0 - 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 Vp! `G _ 2 glazing, dr lowe 0.650 w . _ Age 0.00 _ 0 0 .0 _ .._ 0 _ _ 0 _ ... 0 _ 0 . _0 C 16D-90td. 0.032 - 0.90 e96 198 198 177 _ 190 10 _ _ _10 _ _9 10 F _ -_ _ _ 22Xtph - _ -1-358 - - _ _ 38A2 0.00 _ _ _ 16 _ _ 3 116 _ 0 _ _ 0 - 6 0 0 6 c)AED exursion -110 0 Envelope loss/gain 1878 1118 9 9 12 a) Infiltration 505 w 0 0 b) Room vemilation 0 0 0 0 13 Imemal gains: Occupants @ 230 0 0 0 0 Appliances/other 1500 0 Subtotal (fines 6 to 13) 2383 2763 9 9 Less extemal lead 0 0 0 0 14 Less transfer Redistdbution Subtotal o 203 2586 0 267 3030 0 0 0 0 15 Duct leads 1 26% 31% 669 939 26% 31% 0 0 Total mom lead 1 1 3255 3968 0 0 Air required(cfm) 182 177 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -rla- wrngti�oR- 2020Jan-2813:25:53 Right -Sufi Urthersal 201919.0.08 RSU08101 Page 6 A EMccunmetslWrightsoft HUACIROAF RESIDENCE.rup Cale = MJ8 Front Door faces: N wrightsoft• Right-JO Worksheet Job. AHU 3 Date: Jan 28, zozo By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 ErreII: OUICKCALCS@AOL.COM 1 Room name WIC 3 RATH 3 2 3 Fiyosed wall Room height 5.0 ft 9.6 ft healfcod 6.0 It 9.6 It heallcool 4 5 Room dmensions Room arm 6.0 x 5.0 ft 30.0 ft' 1.0 x 68.0 It 68.0 w Ty Constnxtion number U-value (Stuh/ftz°F) Or HTM (BU1102) Arm or perimeter (ft) Load (Btuh) Arm (ft5 or perimeter (ft) load (Btuh) Heat Cad Gross N/PIS Heat Cool Gross WP/S Heat Cool 611111ggqqq✓✓✓/1 11 � I-G III---GqG _ 13A-75f6s _ 2glazing rlwae 2glazing ocir Iowa 2 glazing or lcxe 2glazing, cir lace _ m-_ri_ 0.650 0.650 0.650 _ 0.650. n n n n _232 `18.200 820 1820 000 _ 000 1110 14.99 14.99 0.00 0.00 _.-_-0 .0 0 0 0 ..-.. 0-_.._ 0 0 0 0 0 0 0 _ 0 _. _� 0 0 0 0 _. _ __a __ __. 0 '0 0 0 , _ _0 _ _ 0 0 0 0 0 ____ _ - 0 0 0 0 __ _0 _ _ .'0 0 0 0 0 ._ 1N �--G 13A-7.5fcs 2 glazing, or Icv a 2 glazing, cir lave 2 glazing, or lcw-e 2glazing, clr lcw-e_ 13A-7.5fm 2 glazing, qr lave 1 glazing, 2 glazing, Ur 10 2 glazing, or lox-e 2 glazing, cir lowe 2 glaziniz dr lcwe_- 1 glazing. 2 glazing, cir low a 2 glazing, cir love 2 glazing, cir lave 0.083 0.650 0.650 0.650 0,650 0.008 _ 0.650 0.653 0.650 0.850 0.650 -- 0.650 0.650 0.650 0.650 0.650 a a a a a se se, s s s s s w w w w� 232 0.00 0.00 18.20 0.00 232 18.20 232 10.20 0.00 0.00 18.20 232 18.20 000 1520 1.10 0.00 0.00 31.52 0.00 1.10 23.31 1.99 14.00 0.00 0.00 14.99 1.10 30.00 3242 2-42 0 0 0 0 0 0 0 0 0 0 0 _ _0 48 0 0 0 0 0 0 0 0 0 -. __0 0 0 0 0 0 48 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 _.0 110 0 '0 0 0 0 0 0 _ .._ _0 0 _ . _ _ 0 0 0 0 0 _0 53 0 0' 0 0 0 0 0 _ _ 0 0 -.0 0 0 0 0 0 58 8 0 0 0 0 0 0 __ 0 0 _ _ 0 0 0 0 0 _ 0 50 1 0 0 0 0 0 0 0 0 _ - . 0 0 0 0 0 _ 0 146 140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 243 -0 0 C 2glazxg,clrlave 16D301d _0.650 0_032 w. - 000 0:91) 0.00 0.96 _ 0 30 0 30 0_ 27 _ 0 29 0 68 -0 0 68 0 _ _ 61 0 _65 _ 'F - _ 22A-tpt1 1.358 . - Mk _ _ -0.00 . 0 0 . - `0 _ _ _-0 _ 0 0 0 6 c)ABD excursion 31 93 Envelope loss/gain 1381 51 1 322 456 12 a) Infiltration 65 19 78 22 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Appliances/other 700 500 Subtotal Olney 6 to 13) 203 770 399 978 Less ademal load 0 0 0 0 Less transfer Redistribution 0 5 0 5 0 89 0 117 14 Subtotal 208 775 409 1095 15 Duct loads 26% 31- 54 240 263/6 31% 127 339 Total mom Intl Air required (cfm) 262 15 1015 45 1 615 34 1434 64 Calculations approved byACCA to meet all requirements of Manual J Sth Ed. _ #F w_rrg'.tso 2020-Jan-2813:25:53 RightSuile® U h,ersal 2019 19.0.08 RSU08101 Page 7 E:IDmunnets%Wdghlsoft WAC\ROAFRESIDENCE.mp Calc=MJB Front Doortaces: N wrightsofY Right-.1® Worksheet Job: AHU 3 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 Emit: OUICKCALCS@nOL.COM 1 Room tame CLUB ROOM STAIRS UP 2 3 Elposed wall Room height 66.0 it 10.2 1t heat/cool 46.0 ft 9.6 ft heat/cool 4 5 Room dimensions Room area 1.0 x 549.0 It 549.0 ft2 1.0 x 205.0 ft 205.0 W Ty Construction number U-value (Bh"ftk.F) Or HTM (BtutVft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cod Gross WP/S Heat Cod Gross WP/S Heat Cod 6 �Vt✓✓��--GG 13A-75(cs --- - 2glazing, dr lore 2 glazing, dr lcx a - '-0083 0.650 0.650 i n n 2.32 1820 18,20 1.10 14.99 14.99 - -X5 8 0 237-- - 0 0 _sW 146 0 281 120 0 163 0 18 - 145 0 0 337 0 328 160 0 770 11 2 glazing, dr lc&e 2glming, dir love 0.650 _.,0.650 n n 0 00 _000 0.00 _ 0.00 0 0 0 0 10, 0 0 _ 0 0 ,. 0 0 _ 0 0 0 0 . o 2 glazing, dr lava 2 glazing, 2 glazing, dr bar/-e 2 glazing, cir love 2 glazing, cir love _ 0.650 0.650 0.650 0.650 ___ _0.650 0.650 a a a a a se 232 0.00 0.00 18.20 0.00 232 0.10 0.00 0.00 31.52 __ 0.00 110 190 0 0 9 _ 0 .. 0 180 0 0 1 __ __ 0 0 420 0 0 164 _ 0 0 204 0 0 284 __ _ -0 0 115 0 0 0 0 0 115 0 0 0 _ -__0 0 260 0 0 0 _ __0 0 120 0 0 0 0 0 t-G 2 A,7.5f,.oltlaue _ 2glazing, 2 glazing, cir love 2 glazing, 2 glazing, dr lovr•e 2 glazing, dr lcx a 2 glazlnq.clr IgAt4. 13A-75fm 2 glazing, cir lave 2 glazing, cir lore 2 glazing, dox-e rl - 0083 0.650 0.650 0.850 0.650 0650 - _0083 0.650 06m 50 0650 s a s s s s w w w' w. . 1232 2.20 18.20 0.00 0.00 1820 --� 232 18.20 0 18.2020 23.10 4.99 14.00 0.00 0.00 14.99 1.10 30. 0.0000 3242 --a 230 0 0 0 128 - 0 0 0 0 0 100 0 0 0 128 - - -0 0 0 0 0 240 0 0 0 _2330 0 00 0 0 0 110 0 0 0 .__ 1919 0 0 0 _. a 0 0 0 0 _- _ 0 163 0 0 20 _ _ __ .0 0 0 0 0 -, 0 143 0 0 1 _ _ '0 0 0 0 0 _ __. 0 333 0 0 364 0 0 0 0 0 _ 0 158 0 0 648 I--G 2 glazing, dr lowe ___.0650 -w_ - 0.00 .0.00 a 0 0 _ 0 .. .0 _ 0 _ 0 0 C 16D-30td 0.032 - 0.90 0.96 549 492 50 205 205 _ 184 197 F 27htph _ 1.358 - __ 3t1.02 _ 0.00 .549 _ 0 0 _ _ 0 . - _ 0 _ _0 _ .0 '0 _ 0 6 c)AED excursion -199 128 Eoelope loss/gain 4358 3234 1813 1689 12 a) Infiltration 907 260 595 171 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Applianceslother 1500 1500 Subtotal Qines 6 to 13) 52% 4994 2408 3360 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 239 313 41 42 14 Subtotal 5505 5308 2449 3402 15 Dud loads 26% 31% 1425 1644 26% 31% 634 1054 Total room load 6930 6952 3083 4455 Air requited (cfm) 3. 309 173 198 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jan-2813.25:53 RighlSuiteS Universal 2019 19.0.08 RSU08101 Page 8 ^.CAA E9Docurraets\Wrightsoft HVAC\ROAF RESIDENCE.rup Cale = MJ8 Front Door aces: N I�+wrightsofr Right-M) Worksheet Job: AHU 3 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 Si LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: OUICKCALCS@,AOL.COM 1 Room name ELEV. 3RD FUR 2 E)posed wall 0 It 3 Room height 9.6 ft heaVcod 4 5 Room dimensions Room area 7.0 x 7.0 ft 49.0 W Ty Constnxdicn U-value Or HTM Area (ft� Laid Area Load number I (Btuwft'-°F) (Btulvft� a perimeter (ft) (Bbuh) or perimeter Heat Cad Gloss N/P/S Heat Cool Gross N/P/S Heat Cod 2 glazing,or loxe 2 glmazihg or lowc 0.650 0.650 n n 1820 18.20 14.99 14:99 0 0 -0 0 0 0 0 0 i _ _ 11 2 glazing,dr low a 2 laze cicla .e 0.SS0 - 0.650 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 o 0 D _ 2 glazing, dr Iox a 2 glazing, 0.653 0.650 a a 232 0.00 0.10 0.00 0 0 0 0 0 0 0 0 2 glazing, Ur lox-e 0.650 a 0.00 0.00 0 0 0 0 2 glazing, clr Io 0.650 a 18.20 31.52 0 0 0 0 2 glazing, clr lvv-e 0,650 a 0.00 0.00 0 0 0 0 ,W `G _ 13A-7.Sf., 2glazin0,d[IoN:e _ 0.650 0.083 se 232 _ 18.20 _ 1.10 _ '21.10 - .0 0 0 ___0 _ 0 C 0 , 0 - - 0.650 a s 232 0 0 0 0 2 glazing, clr loNe 2 glazing, 0.650 s 10.20 4.99 14.00 0 0 0 0 291azirg, drlwfe 0.650 s 0.00 0.00 0 0 0 0 2 glazing, dr lcv a 0.650 s 0.00 0.00 0 0 0 0 glazinn, clr love 0.650 s 18.20 1.4.99 0 0 0 0 _ IW _ _2 13A-7.5fcs - - - - - 0.083 -'w - - 232 _ 1.10 0 -- - 0 - - 0 - -0- - - - 2 glazing, dr lox a 0.650 w 18.20 3l .39 0 0. 0 0 2 glazing, Ur [o '2 glazing, dr,l: 0.650 0.650 .w w 0.00 18.20 o.00 3242 0 '0 0 0 0 0 0 0 _ 2 glazing, Ur low-e_ _ _ 0.650 w. 0.00 0.00 0 _ ,0 ._- _-_a _ _ 0 C 16D-301d 0.032 - 0.90 0.96 49 49 44 47 F - 224tph_. _ 1.358 - 38.02 0.00 0 �0 _ - ,_ , :0 - , _ 0 _ 6 c)AED eloursion -2 Envelope Ices/gain 44 45 12 a) Nfikration 0 0 b) Roan%entilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appfiances/dher 0 Subtotal (fines 6 to 13) 44 45 Less e#emal load 0 0 Less transfer 0 0 Redistribution -44 -05 14 Subtotal 0 0 15 Dud loads 26% 31% 0 0 Total mom load 0 0 Air required (drn) 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. _ -p}f wrrghisoit- 2020-Jan-2813:25:53 RightSuiteO Universal 2019 19.0.08 RSU08101 Page 9 E:1DecunmetslWdghtsoftWAC1ROAFRESIDENCE.mp Calc=MJ8 Fmnl Doorfaces: N wrightsoft Right-M) Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A66-6796 Eneil: OUICKCALCS@AOL.COM 1 Room name AHU1 LMNGlDMING 2 Bposed wall 131.2 It 23.0 ft 3 Room height 10.1 ft 10.1 ft heat(cool 4 Room dimensions 1.0 x 547.5 ft 5 Room area 1741.5 W 547.5 ft- Ty Construction U-,.aloe Or HTM Arm (ft5 Load Area (R5 Load number (BtulVftMF7 (Btuh/ftj or perimeter (ft) (Btuh) or pedmeter (ft) (Btuh) Heat Cod Gmss N/P/S Heat Cool Gross N/P!S Heal Cod 6 13A-7.5fcs 2 glazing clr 1w 6.083 0.650 n n 232 0.00 1:10 0.00 394 0 - 286 0 - ---608 0 -- 327 0 - 0 0 --0 0 -- - 0 0 - -0 0 2 glazing, clrIo 0.650 n 000 0.00 0 0 0 0 '0 0 0 0 11 2 glazing, clr love 2 glazing,clr lox-e 0.650 0650 n _n,_ 1820 .1820, 14.99 14.99 50 _ 48-_ 0 0 910 __'SZ4 750 --._720 0 _ _ 0 0 _. .0._ 0 _ '0_ 0 - 0 I� 2 glazing, clr 2glazing, 0.650 0.650 a a 232 0.00 0.10 0.00 81 0 81 0 180 0 89 0 0 0 0 0 0 0 0 0 Io 2 glazing, dr lave 0.850 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir lox-e 2 glazing, clr lower 0.650 0.650 a e 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I - _ '2 _ - 0.650 se _ _ 232 _ 43 22 _ 24 0 - - 0 - - - ' _ 0 _ 2glazi5f Urlax-e - glazing, 0.65g -,se 18.20 3.31 .21.10 21 . _ ._ _ 76 - __212 __ __ --0 _ ___4 0 .-. _ _0 __.0 0.653 s 232 1.10 370 2 190 446 44a 21a 232 104 240 110 2 glazing, or lave 2 glazing, 0.650 s 0 0 0 0 0 0 0 0 2 glazing, or low-e 0.650 s 8.20 18.20 4.99 14.99 54 54 983 810 0 0 0 0 2 glazing, or low a 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 plazim, df low-e 13A-75fas _ 0.650 0.083 s_ -w 18.20 - --232 14.99 1.A0 _ _ _ 128 434 _128 418 2330 972 1919 ----462 128 - -'0 128 - - - 0 2330 - - -0 1919 - 0 2 glazing, or Io 0.650 w 18.20 30.39 8 1 146 243 0 0 0 0 2 glazing, or Io 2 glazing, or 1a 0.650 0.650 w w 18 20 0.00 3208 -0.00 8 0 1 -0 146 0 267 0 0 0 0 0 0 0 0 0 _ 2 glazing, or lox e _ _ 0.650 _w- _ 0.00 . _ 0.00-- .0 _ .0 __ :0 - -_0 _ . -0 ..._ 0 .0 0 C 16D-30td 0.032 0.90 0.98 648 648 580 622 46 46 41 44 F `27/>,-tpti _ _ _ _ - 1.358 -_ 38.02 0.00 - -59 - .2 - 73 _. _ . 0 _ _ . 0 . _ 0 _ 0 _ _ _ 0 6 c)AED excursion 0 -96 Ermlope losslgain 8762 6914 2513 1982 12 a) Infiltration 1787 513 313 90 b) Room ventilation 0 0 0 0 13 Int mat gains: Occupants @ 230 0 0 0 0 Appliances/other 11250 2400 Subtotal (fines 6 to 13) 10548 18677 2926 4471 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 187 253 14 Subtotal 10548 18677 3113 4725 15 Duct loads 1 54% 43% 5676 8119 54% 43% 1675 2054 Total room load 16224 26797 1 4769 6779 Air required(cfm) 1173 1173 346 297 Calculations approved Calculations approved byACCA to meet all requirements of Manual J 8th Edto meet all requirements of Manual J 8th Ed. wrlgf.boR- 2020-Jan-2813:25:53 C Right-SUHeS Universal 2019 19.0.08 RSU08101 Page 10 E:1Docunnets\Wdghtsoft HVAC1ROAFRESIDENCE.mp Calc=MJ8 Front Doorfaces: N +wrightscift* Righttil®Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM 1 Room name GARAGE ELEV. ELEV. 2ND 2 E1posed wall 0 It 0 ft 3 Room height 10.1 ft heaUcool 10.1 It heat/cool 4 5 Room dimensions Room area 1.0 x 47.0 ft 47.0 ft2 7.0 x 7.0 It 49.0 W Ty Constnx:tion U-value Or HTM Arm (ftl Load Area (ft� Load number (Btuhfft�-F) (Bluwft� or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 _ 13H-75fc5 lose 2 glazing, cir l650 2glazing, dr love _-..00m 0.650 0650 o n n _232 000 000 1.10 0.00 0.00 ___O. 0 0 ------ 0_ 0 a .-0 0 '0 _- _ O.__ 0 0 _a a 0 0 0 0 0 0 0 0 0 11 l-G -GG 2 glazing, Gr lcm e 2glazig,dr lwv 0.650 - 0.650 n -n 18.20 ._ 18.20 14.99 14.99 0 _ _ 0 0 _ 0. 0 __.__0, 0 _0 0 a 0 0 0 _ 0 0 _ _ -0 llf/--G 136-7.5fes 2 glazing, dr lave 2 glazing, dr love 0.083 0.650 0.650 a a a 232 0.00 0.00 1.10 0.00 0.00 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I-G 2 glazing, clr lore 2 glazing, dr lave 0.650 0.650 a e 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 o 0 0 0 0 0 0 lqJ `G _ 13A-7.51cs 2 glazing,.dr love _ O609 _. 0.650 s-e se _ 232 _ 18.20 1.16 . _ 23.31 _ 0 - 0 0 _ _0 _ _ -0 0 _ , 0 _ _ _ --a 0 0 _ _ 0 _ _. _ 0 _ 0 _ _ 0 6 '0 _ 0 _ 0 �N 13A-7.5fcs 0.083 s 232 1.10 0 0 0 0 0 a 0 0 l--G I--G 2 glazing, dr lave 2 glazing, dr lox-e 0.650 0.650 s s 0.00 18.20 0.00 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I�---GG 2 glazing, dr lave 2glazing, clr lave _ _ 13A-7.51cs 0.650 0.650 0.083 s _a_ w 0.00 _ 18.20 232 0.00 _14.99 1.10 0 0 0 0 _ 0 0 a ___ _ 0 0 0 _ 0 i_o 0 _ _ 0 0 0 __ 0 0 0 0 0 0 _ 0 0 c 2 glazing, or lowe 2 glazing, cir love 2 glazing, or lave 2 glazing,. cir Im" 16D30td 0.650 0.650 0.650 __ _:0.650 0.032 w w w w-.. 1820 18.20 0.00 0.D0 0.90 30.39 32-08 0.00 0.00 0 0 0 - _ .0 a 0 0 0 0 0 0 0 0 _ .. 0 0 0 0 0 ._ _.a a a 0 0 _ _ 0 a a 0 0 a a 0 0 0 0 0 0 0 0 0 0 _ F _ _ 7JA-tph _ .. __ _ 1.358 - 38.02 _0.96 0.00 _ 47 0 _ ___ . _ �0 _ �__ . _ 0 _ _ _0 0 0 _ 0 6 c)AED excursion a 0 Ermlope loss/gain 0 0 0 0 12 a) Inrinnaticn 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internet gains: Occupants Q 230 0 0 0 0 Applianceslother 0 0 Subtotal 01nes 6 to 13) 0 0 0 0 Less edema) load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 549% 439/6 0 0 54% 43% 0 0 Total room load 0 0 0 0 Air required(cfm) a a 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -/}f wrlg_l.c�sofc- 2020Jan-2813:25:53 A - Right -Suite® Universal 2019 19.0.08 RSU08101 Page 11 E:1DocunoelslWdghlsoft HVAC1ROAFRESIDENCE.mp Calc=MJB Front Doorfaces: N wrightsoft Right -A) Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 F. 7724666796 Email: OUICKCALCS@AOL.COM 1 Room name UTILITY STORAGE WIC 2 3 Flrposed wall Room height 19.0 ft 10.1 ft heat/cool 8.0 ft 10.1 ft heal/cool 4 5 Room dimensions Room area 1.0 x 108.0 ft 108.0 ft2 1.0 x 50.0 ft 50.0 ft2 Ty Construction number U-telue (Btu Vitt-F) Or HTM (Btut✓ft Arm (ftj or perimeter (ft) Load (Btuh) Arm (ft' or perimeter (ft) Load (Btuh) Heat Cod Gloss WP/S Heat Cool Grass WP/S Heat Cod 6 11 IV 13A-75f6 2glazing clr ldve 2 glazing cir bate 2 glazing, cir love 2glazing, cirlotte � 0.083 0.650 0.650 0.650 _ 0.650 n n n n n 232 000 0.00 18.20 ___1820 1.70�-- 0.00 0.00 14.99 _ .14.99 111 0 0 20 0 �- �91 0 0 0 _0 ------212 0 0 364 0 - 101 0 0 300 _ _ _ �-0- 0 0 0 _ - 0- 0 0 0 0 0 0 0 _O 0 0 0 0 _ 0 _--G -L=:G 13A-7.5fcs 2 glazing, clr low a 2 glazing, cir lave 2 glazing, clr lowe 2 glazing, cir_ lovv-e _ 13A-7.5fw 2 glazing, clr lowe _ _ 13A-7.5fcs 2 glazing, clr lowe 2 glazing, cir lowe 2 glazing, dr lave 2 plazlnp cir lox-e_ 13A-751cs 2 glazing, dr to a 2 glazing dr lc a 2 lazing, dr lose g 2 glazing, dr lave 16D30td 0.083 0.650 0.650 0.650 . _ 0.650 O.OB3 __. 0.650 0.083 0.650 0.650 0.650 0.650 0.083 0.680 0.650 0.650 0.650 0.032 a a a a _ e se se. a s s s s _ w w w w w. - 232 0.00 0.00 0.00 _ 0_00 232 _ .18.20 232 0.00 18.20 0.00 18 20 232 18.20 1820 020 0 00 0.90 1.10 0.00 0.00 0.00 _ 0.00 11.10 23.31 1.10 0.00 14.99 0.00 1.10 30.39 039 3200 '0.00 0.00 0.96 0 0 0 0 _ 0 0 _ _ -0-- 0 0 0 0 _ _ 0 81 0 0 0 _ _ -0 88 0 0 0 0 _ 0 0 0 0 0 0 0 _ 0 81 0 0 0 0 88 0 0 0 0 0 6 10 0 0 0 0 _ _ _ 0 188 0 0 0 _ 0 79 0 0 0 0 _ 0 - -0 _ _0 0 0 0 0 ___.._ 0 89 0 0 0 _ 0 0 0 0 0 _ _ _ 0 0 _ _ 0 0 0 0 0 __ 0 81 0 '0 0 _ 0 _ 0 0 0 0 0 _ 0 0 _. _ _ 0 0 0 0 0 _ _. 0 - 81 0 0 0 _ .6 0 0 0 0 0 _ _ 0 0 _ 0 0 0 0 _ 0 188 0 0 0 _ 0 _ 0 0 0 0 0 0 0 0 0 0 0 _ 0 '89 0 0 0 0 0 15J .`_G W . C F 224tph _ 1.358 --- - 38.02 - - . _ .0.00 _ _ _ 0 _ 0 _ 0 _ _84 0 0 _ 0 0 0 6 c)AED emursion- -24 -17 Envelope loss/gain 842 550 188 72 12 a) Infiltration 259 74 109 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appriances/other 0 0 500 0 0 700 Subtotal (fines 6 to 13) 1101 1124 297 803 Less e#emal load 0 0 1 0 0 14 15 Less transfer Redistribution Subtotal Dud loads 54% 43% 0 0 1101 592 0 0 1124 489 54-A 43% 0 0 297 160 0 0 803 349 Total room load Air required (otm) 1693 122 1613 71 456 33 1152 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -rp- mnon!mntR 2020-Ja 2813:25.53 RightSuee® Universal 2019 19.0.08 RSU08101 Page 12 AC�A EADocurmets\Wrightsoft HVAC\ROAF RESIDENCE.mp Cato =MJB Front Door faces: N wrightsofiRight-JO Worksheet Job: AHU9 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Rcom name FOYER PANTRY 2 Fposed well 9.0 ft 17.0 It 3 Room height 10.1 ft heav000l 10.1 It heat/cool 4 5 Room dimensions Room area 9.0 x 8.0 ft 720 ft' 1.0 x 128.0 It 128.0 ft' Ty Construction number U-lelue (BtUVft22F) Or HTM (BtuNft5 Area (ftj a perimeter (ft) Load (Btuh) Area (ft� a perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cod 6 2 glazing cir love 2 g1ming, Ur ldwe 2 g1ming, 0.653 0.650 0.650 n n n 232 0.00 O 00 1 10 0.00 '0.00 - .0 '0 0 -40 0 0 -- --100 0 0 - 47 0 0 152 0 0 _� 122 0 0 280 0 0 -_734 0 0 11 2 glazing, Ur love 2g1azng, cIr ldx 0.650 -0.650 n -n.. 1820 _ _ 1820 14.99 _14.99 '0 _ 48 0 - . 0 10 _87.4 0 ___ 720 30 _ ----0 0 _ _0 546 _ '0 450 0 lq/ 2 glazing, Ur 1w 2glazing, z glazing, co- love 0.650 0.650 0.650 a a a 232 0.00 0.00 1.10 0.00 0.06 0 0 D 0 0 o 0 0 0 0 0 0 10 0 0 10 0 0 23 0 0 11 0 0 2 glazing, cir loH a 2 glazing, dr lore 0.650 0.650 a e 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 lqJ LG _ 13A-7.5fm 2 glazing, Ur lmN e - - _ _ 0.083 _ 0.650 _ se -se _ 232 18.20 _ 1.10 23.31 '0 _ 0 0 0 _ 0 _ ..0 _ 0 - . _ 0 _ - 0 _ 0 _ _ 0 0 _ '0 0 0 0 0.650 s 232 1.10 0 0 0 0 0 0 0 0 2 glazing, Ur 1w 2 glazing, 2 glazing, Ur lows 0.650 0.650 s s 18.20 8.20 4.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr taros 2 glazing, cir lone _ 13A-7.51cs 0.650 _ 0.650 0.083 s s % 0.00 18.20 232 0.00 14.99 1.10 0 0 0 0 , _ 0 a 0 _ _ 0 - o 0 _ -- 0 0 0 - -- 0 10 0 _ 0 10 0 _ _ 0 23 0 0 11 2 glazing, Ur lone 2 glazing, Ur IoN a 2 glazing, dr lox a 0.650 0.650 0.650 w w w 18.20 18.20 0.00 30.39 3208 0.00 0 0 '0 0 0 0 0 g 6 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, Ur lave .. __. 0.656 _w- 0.00 0.00' 0 _ 0 - - 0 0 _ - 0 ..0 _ .0 0 C 16D-Md 0.032 - 0.90 0.96 72 72 65 69 128 128 115 123 F _ _ 22Fttph - � 11358 a 38.02 0.00 0 '0 _ 0 � _ ,0 8 _ 1 40 0 6 c)AEC) mursion -33 -24 Envelope lass/gain 1038 803 1030 705 12 a) Infiltration 123 35 231 66 b) Room %entilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 700 350 Subtotal (fines 6 to 13) 1160 1538 1252 1121 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 118 59 14 Subtotal 1160 1538 1380 1181 15 Duct loads 54% 43% 624 669 54% 43% 743 513 Trial room load 1785 22W 2122 1694 Air required (cfm) 129 97 153 74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -pi- wrighiv-o� 2020.Wn-2813:25:53 Right-Sufte® Universal 201919.0.08 RSW8101 Page 13 E:1DmurmetslWdghtsoft i1UAC\ROAF RESIDENCE.mp Celc = MJ8 Front Door faces: N wrightsoftRight- J® Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: ONCKCALCS@AOL.COM 1 Room name A/C CHASE IaTCHEN 2 3 Elrposed wall Room height 4.0 ft 10.1 If heal/cool 0 it 10.1 ft txaUccol 4 5 Room dmensions Room area 4.0 x 8.0 If 320 It' 1.0 x 369.0 ft 369.0 ft' Ty Construction number U-talus (BtuWftk'F) Or HTM (BlulVit') Arm (ftj or perineter (ft) Wall (Btuh) Area (ft� or Perimeter (it) Load (Btuh) Heat Cool Gross NIP/S Heat Cool GIo s WP/S Heat Cool 6 13A-7 5fcs 2 glazing Ur lore 2 glazing, dr Iode - -0.083 0.650 0.650 n - n n - -- 232 O OD 0.00 _ 1.1040 0.00 0.00 0 0 -- 40-' 0 0 - 94 0 a -- 45 0 0 0 o 0 0 0 0 00 0 0 0 0 11 2 glazing, Ur lore 2 glazing,Ur lcwe 0.650 -0.650 n --.n- 18 20 _1820 14.99 _14.99 a . 0 0 0 a 0 0 _ _ 0 0 ._.. _0 a _. '0 0 _ 0 0 _ _ 0 llllljj�(jJJJJ/ I-G III----GGG _ 1p1 -`G _ W ' - C 13A-7.51cs 2 glazing, Ur lace 2 glazing, Ur lowe 2 glazing, Ur lowe 2 glazing, Ur lave 13A- 5fcs 2glazirg, ilr lave 2 glazing, clr lowe 2 glazing, 2 glazing, Ur lode 2 glazing, Ur lode 2 glazing,_ or low-e 13A-7.5fcs 2 glazing, Ur lode 2 glatirg,Ur lave 2 glazing, Ur lode 2glazirg, drlode 16D-301d_ 0.D83 0.650 0.650 Q650 _ 0.650 O m 0.650 Q683 (1650 0.650 0.650 0.650 - - 0.083 0.650 0.650 0.650 0.650 0.032 a a a a a se as. s s s s s w- w w w w - 232 0.00 0.00 0.00 0.00 232 18.20 232 .. 188.2020 0.00 18.20 232 18.20 1820 -000 0.00 0.90 1.10 0.00 0.00 0.00 _ 0.00 1.1(1 _ 23.31 1.10 14.9999 0.00 14.99 ' " 1.10 30.39 3208 (100 _ 0.00 0,96 0 0 0 0 _ _ 0 6. _ . 0 0 0 0 0 0 0' 0 0 0 -0 32 0 0 0 0 0 - �- '0 _ , 0 0 0 0 0 _ 0 - 0 0 0 0 __ 0 32 0 0 a 0 0 - - 0 0 0 a 0 0 --0 0 0 0 0 -0 29 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 _ -_ -_0 31 0 0 0 0 0 '- 0 ,_ 0 0 0 0 0 _ , _-0 �a 0 o 'a 0 276 0 0 a 0 _ _ 0 0 , - - _:0 0 0 0 0 ._ 0 - 0 0 0 0 _ 0 276 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 _ _ 0 247 0 0 0 0 0 0 a 0 0 0 0 _ _ o 0 0 0 0 0 265 _ F _ 22A-tph .. _ .1.358 _ - - 38.02 0.00 _. 0: _ .0 - _ _ _ 6 c)AED excursion -2 -101 Envelope loss/gain 123 73 247 164 12 a) Infiltration 54 16 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appriancesfother 0 4500 Subtotal (fines 6 to 13) 177 89 247 4664 Less eldemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -177 0 0 -89 0 0 59 306 0 30 4694 15 Duct loads 54% 43% 0 0 54% 43% 165 2041 Total man load Air required I'M) 0 0 0 0 471 34 6735 295 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -+- wrighlsoR- 2020Jam2813:25:53 RighlSudeG Universal 2019 19.0.08 RSUD8101 Page 14 EADocurmetslWrightsoft HVACIROAF RESIDENCE.rup Calc = MJ8 Front Door faces: N wrightsofr Right-M Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone- 772-4666799 Faz 772-4666796 ErreiC OUICKCALCSrAOL.COM 1 Roomnarne BEDROOM HALL2 2 Eked wall 35.0 it 4.2 It 3 Room height 10.1 It heat/cool 10.1 It heatfcool 4 5 Room dimenaicna Room area 1.0 x 161.5 it 161.5 ft2 1.0 x 30.0 ft 30.0 It' Ty Construction number U-value (etuh/ttz°F) Or HTM (BtulVft5 Area (ftj or perimeter (ft) Load (Btuh) AM (ftj or pedmeter (ft) Load (Btuh) Heat Cool Gmss N/P/S Heat Cool Gmss N/P/S Heat Cool 6 ___. 13A-75fds dr loiiii,e_ dr 0.083 n 232 0.00 0.00 _ 0 0 a ._. 0. 0 o ___ 0 0 a _.__0 0 o _.-___ 0 0 0 __ _0 0 o __ __ d 0 q _ __0 0 0 dr la�e 0.650 n 4.99 a 0 0 0 0 a 0 0 11 2glazing,drloA•e 0650 ' n _- 1800 1110 _4.99 '0 _-_0 --.--0 ---- _ u_ a __ _o_ _ o-. a _ WWWWllttJJ 13A-7.5fm 2 glazing, cir low a 2 glazing, dr lore 0.083 0.650 0.650 a a a 232 0.00 0.00 1.10 0.00 0.00 71 0 0 71 0 0 164 0 0 78 0 0 0 0 0 a 0 0 0 0 0 0 0 0 2 glazing, dr lox-e 2glazing, dr Im" 0.650 0.650 a a 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ lqJ `G 13A-7.ng,- 2 gla&g, �r bv-e 13A-7.5fcs 0.650 _ _ _ 0.083 0.083 se a s 232 1&20 2.32 _0.00 410 _ 21.10 1.10 - -.0 -0 141 0 _ --0 87 - 0 0 203 -0 . _. _ 6 96 _ 43 _20 0 _ 22 _ _ 6 0 _0 52 376 0 24 480 0 2 glazing, dr hx 2 glazng, dr lbv 0.650 0.650 s s 0.00 18.20 0.00 14.99 0 54 0 54 0 983 0 810 0 0 0 0 0 0 0 0 .___. 2 glazing, cir tome 2glazirim Ur lore '13A-7.5fcs 0.650 __._ 0.650 0.083 s _ s_ w 0.00 A20 232 0.00 _ 14.99 1.10 0 _ 0 141 0 _ _ _. _0 141 0 _ __ .__ 0 329 0 __ ___ _0 156 0 . ._ __ 0.. 0 0 _ _ ._ 0 0 0 0 0 0 0 0 2 glazing, cir low.e 2 glazing, dr tm, 2glazing, clr Iw 0.650 0.650 0.650 w w w 18.20 18.20 0.00 30.39 3208 0.00 0 0 0 0 0 0 '0 0 0 0 0 0 0 '0 6 a 0 0 0 0 0 0 0 0 ' C 2 glazing, clr lose 16D30td _ ._0.650 0.032 w. _ ..0.00 0.90 0.00 0.96 .0 4 _0 4 _ __ _0 -_ 4 __ ___ 0 4 .. _ .0 2 . . _ 0 _ _ 2 _ 0 2 . _ 0 2 _ F _ OA-tph _ .,1.'350 = _ 38.02 0.00 4 _1 _ 30 - ___.___ .0 _ .0. 0 0 0 61 c)AED excursion -27 134 Envelope loss/gain 1715 1117 429 642 12 a) Infiltration 476 137 58 17 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (fides 6 to 13) 2192 1254 487 658 Less eternal load 0 0 0 0 Less transfer Redistnhution 0 187 0 253 0 487 0 -am 14 Subtotal 2379 1507 0 0 15 Dud loads 1 54% 43% 1280 655 54% 43% 0 0 Total rmm Imd 3658 2162 0 0 Pin sequined 265 95 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. 2020-Jan-28 13:25:53 Right -Suite® Universal 201919.0eB RSU08101 Page 15 �A EADocumretslWrightsoft WAC\ROAF RESIDENCE.rup Calc=MJS Front Door taws:N wrightsoftRight-JO Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fauc 772-466-6796 Emil: OUICKCALCS(gAOLCOM 1 Room name WIC 2 BATH 2 2 Exposed wall 0 1t 120 It 3 Room height 10.1 ft heat(Caol 10.1 It heaUcool 4 5 Room drtxnsions Room am 1.0 x 23.5 ft 23.5 W 1.0 x 66.0 ft 66.0 ft' Ty Constmcum U-value Or HTM Area (ft� Load Area Load number (BtuIVWF) (BtuWftj or perimeter (ft) (Btuh) or Penmeter (ft) (atuh) Heat Cool Gross WP/S Heat Cad Gross WP/S Heat Ccd 6 13A-7 5fcs - 2 glazing, cir lowe 2 glazing, dr Ia." - 0 083 Q650 0.650 I n n __ 232 000 000 1.10 0.00 0.00 -0 0 0 -.-. 0 0 0 ._ . -_ 0 0 0 - . _ __.0 0 0 _._ _0 0 0 __ _ _ .0 0 0 _ _ _ 0 0 0 _-_.r0 '0 0 11 2 glazing; or lov" 2glazing, or Im" 0.650 _ 0.650 n ,n__ 18.20 1820 14.99 14.99 0 - 0 0 -- 0 0 __ .0 0 - 0 0 _ -0 0 _ _ 0 0 - 0 0 _ -, 0 - lqJ 2 glazing, olr lave 2 glazing, 2 glazing, or e bp 0.650 0.650 0.850 a a a 232 0.00 0.00 0.10 0.oa e00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 tl4J =G 2 glazing, clr lave 2g1azing, dr loye 13A-7.5fm 2glazing,drlati-e 0.650 _ __ 0.650 0.083 0.650 0.650 a _ e se -se-. s 0.00 0.00 232 .18.20 232 0.00 0.00 1.10 . _ 23.31 1.10 0 _0 0 - ... 0 0 0 _ _ .0 0 - 0 0 0 . 0 '0 0 0 0 _ _. _..0 0 0 0 0 _ _ 0 0 _ _ 0 0 0 _ 0 �0 0 0 0 _ 0 0 -_ 0 0 0 __- _ 0 6 _ _.0 0 2 glazing, clr lave 2 glazing, 2 glazing, clr Ivv-e 0.650 0.650 s s .. 18.20 20 144.9999 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 2 glazing, cir lope 2glazimdr lava 13A-7.5fm - 2 glazing, dr lope 2 glazing. dr lope 2 glazing, dr lave 2 glazing, dr lave 0.650 0.650 - 0083 0.650 0.650 0.650 _0.650 s s w w w w w 0.00 __1820 232 18.20 18.20 (DO 0.00 Den 14.99 1.10 30.39 3208 '0.00 ._0.00 0 0 - - 0 0 0 0 _0 0 0 - 0 0 0 0 _. _ _0 0 0 - - 0 0 0 0 _. 0. 0 0 - -0' 0 0 0 _ 0 0 0 121 a 8 0 _ _ 0 0 __0 105 1 1 0 _ _.0 0 0 - - 244 146 146 0 t ._ 0 0 0 - 116 243 257 0 0 C 16DMd 0.D32 0.90 0.96 0 0 0 0 0 0 0 0 F 22A-tph _ 1.358 _�- �38.02 0.00 _ 0 0 _ ._ 0 o 0 _-0 0 0 6 c)AED excursion -15 220 Envelope loss/gain 0 -is 536 836 12 a) InFiftration 0 0 163 47 b) Roomlentilation 0 0 1 0 0 13 Interval gains: Occupants @ 230 0 0 0 0 Appliances/aher 700 700 Subtotal (fines 6 to 13) 0 685 699 1583 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 112 152 0 0 14 Subtotal 112 837 699 1583 15 Duct leads 549% 43% 60 364 54% 43% 376 688 Totalroomload 173 1201 1075 2271 Air required (cfm) 12 53 78 99 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. _ -4- wrrg!=laoPl- 202(Wan-2813:26.53 ACM Right -Suite® Universal 2019 19.0.08 RSU08101 Page 16 E:1DocurmetslWrightsoft HVAC1ROAF RESIDENCE.rup Cale=MJ8 Front Door faces: N wrightsoft Right-JO Worksheet Job: AHU1 Date: Jan 28, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 Room name POWDER RM 2 EKpmed wall 0 ft 3 Room height 10.1 ft heat/cool 4 Room dimensions 1.0 x 58.0 It 5 Room area 58.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area Load number (BtuIJft2-F) (Btulvft= a perimeter (ft) (Btuh) or perimeter Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-75fos -__. 0.083 n 232 110� - -.0__ ._0__ -.,0. _g 2 glazing Ur Iowe 2 glazing or lave Q650 0.650 n n D DO 0.00 0.00 .0.00 0 0 0 0 0 0 a a -.II --��2 1-G III -- 11 2glazing ctr lobe 2glazing,clrlox.e__ 0.650 0.650 n n 1820 _.. 1820 14.99 14:99 0 .. _ _0 0 _ _0_ 0 _ , 0 0 ___0 0.650 a 232 0 0 0 a 2 glazing, ctr lave 2 glazing, 0.650 a 0.00 0.10 0.00 0 0 0 0 2 glazing, clrlave 0.650 a 0.00 0.00 0 0 a 0 2 glazing, ctr Iave 0.650 a 0.00 0.00 0 0 o 0 2glazing,clrlov-e 0.650 a 0.00 0_00 0 0 0_ 0 1hV �G _ 13h7.5fm 291azirg,drlo . 0.083 _ _ 0.65a 0.653 se ,se_ s 2.32 .18.20 = 1.10 23.31 1.10 '0 0 0 _ 0 0 0 _ 0 _ a 0 - --0 __. -0 0 - �- -- --- - - - - 2 glazing, dr love 2 glazing, s 0.00 0 a 0 0 2 glazing, ctr lave 0.650 0.650 s 8.20 10.00 4.99 14.00 0 a 0 0 2 glazing, ctr loves 0.650 s 0 0 0 0 yly�yV 2 glazing, ctr law:e___ 13A-b5fcs _ _ -o.650 0.083 - s_ w 8.20 _ 12-32 232 4.99 _1.4.99 � 1.10 0 0 -' a 0 __'_ 0 0 __. -.- p 0 l--G 2 glazing, dr lava 0.650 w 18.20 30.39 0 0 0 0 2 glazing, ctr Iawe cw-e z glazing, drl 0.650 0.650 w w 18.20 o.00 30.0 0.00 0 a 0 o �0 0 0 0 IIL----GGG C 2 glazing or lave _. 16D30td _. 0.650 0.032 .w - 0.00 0.90 . _ 0.00 0.96 0 0 .. -0 0 _ _ 0 0 . _ -0 0 F _ MA-tph 1.358 _�. _ . 38.02 _ A. -Go a .0 __ _0 __. __ 0- 6 c)AED exumlon -15 Envelope loss/gain 0 -15 12 a) infiltration 0 o b) Room ventilation o 0 13 Intenlal gains: Occupants @ 230 0 0 Appliances/other 700 Subrtotal (lines 6 to 13) a 685 Less endemal load o 0 Less lmnsfer a 0 Redistribution a 0 14 Subtotal 0 685 15 Duct loads 549% 43%1 0 298 Total nwm load a 983 Air required (cfm) 0 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -ri- wrlglrlsofC 2020-Jan-2813:25:53 Right -Suite® Uniwrsai 201919.0.08 RSU08101 Page 17 E:\Docunmets%Wdghtsoft WACIROAF RESIDENCE.mp Calc = MJ8 Front Door faces: N + wrightsofto Duct System Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6796 Email: ONCKCALCSgAOL.COM Project• • For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORTST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (I -EL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 590 cfm Job: Date: Jan 28, 2020 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 590 cfm 216 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk M BATH h 2069 153 112 1.000 7.0 Ox 0 VIFx 23.0 155.0 st10 M CLST c 1102 24 50 1.000 6.0 Ox0 VIFx 24.0 155.0 st10 M TOILET c 1013 4 46 1.000 6.0 Ox0 VIFx 21.7 155.0 st10 M wic i h 816 60 44 1.000 6.0 OxO VIFx 39.6 175.0 st11 M WIC c 1022 5 46 1,000 6.0 OxO VIFx 36.9 175.0 st11 MASTER BEDROOM h 2327 172 146 1.000 8.0 OxO VIFx 40.3 175.0 St11 MASTER BEDROOM -A h 2327 172 1 146 1.000 8.0 Ox0 VIFx 41.1 175.0 St11 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (n) Material Trunk st11 Peak AVF 409 381 1.000 750 10.0 0 x 0 VinlFlx st10 st10 Peak AVF 590 590 1,000 751 12.0 0 x 0 VinIFIX st4 st4 Peak AVF 590 590 1.000 751 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (n) Htg (cfm) Clg (cfm) TEL (ft) Design Veloc Diam H x W Stud/Joist Opening (n) Duct Matl Trunk rb1 OxO 1 590 590 0 1 0 0 0 Ox 0 1 VIFx wright safY' 2020-Jan-28 13:26:05 � Right -Suite® UniwtsaI201919.0.08 RSU08101 Page 1 zr;KE:\DocunmetslWnghtsoAHVAC\ROAFRESIDENCE.mp Calc=MJ9 Front Doorfaces: N Duct System Summary Date: Jan 28, 2020 - wrightsoftAHU 3 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fasc 772-466-6795 Erretl: QUICKCALCS@AOL.COM Project• • For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORT ST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 793 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 793 cfm 180 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Gig (cfm) Design FR Diam (in) H x W (In) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH3 c 1434 34 64 1.000 6.0 Ox0 VIFx 10.9 115.0 st1 BEDROOM h 3255 182 177 1.000 8.0 Ox0 VIFx 11.5 115.0 st1 CLUBROOM h 3465 194 155 1.000 8.0 Ox0 VIFx 22.1 115.0 st2 CLUB ROOM -A h 3465 194 155 1.000 8.0 Ox0 VIFx 20.1 115.0 st2 STAIRS UP -A c 2228 86 99 1.000 7.0 Ox0 VIFx 43.6 135.0 sty SWIRS UP-B c 2228 86 99 1.000 7.0 OxO VIFx 44.6 135.0 sty Nnc 3 c 1015 15 45 1.000 6.0 Ox 0 VIFx 11.5 115.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st5 Peak AVF 173 198 1.000 568 8.0 0 x 0 VinlFlx st2 st2 Peak AVF 561 507 1.000 851 11.0 0 x 0 VinIFIX st1 Peak AVF 232 286 1.000 646 9.0 0 x 0 VInIFIX Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matt Trunk rb3 Ox0 793 793 0 0 0 0 Ox 0 VIFx .` wrightsofY 2020-Jan-2813:26:05 Right-Sufte® Unn,ersal 201919.0.08 RSW8101 Page 2 E:1DocumOets\Wrightsoft WAC\ROAF RESIDENCE.rap Cale = MJ8 Front Door faces: N - wrightsoft Duct System Summary AHU9 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772-466-6799 Faz 772AB6-6798 Emil: OUICKCALCSIAOL.COM For. ROAF RESIDENCE, OAKMONT CUSTOM HOMES 7683 PELICAN POINTE DRIVE, PORT ST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm Job: Date: Jan 28, 2020 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm 238 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Gig (cfm) Design FR Diam (In) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA1142 c 2271 78 99 1.000 7.0 Ox0 VIFx 52.0 180.0 st7 BEDROOM h 3659 265 95 1.000 7.0 Ox0 VIFx 58.4 180.0 st7 FOYER h 1785 129 97 1.000 7.0 Ox0 VIFx 22.7 160.0 st8 GARAGE ELEV. c 0 0 0 1.000 0 OX0 VIFx 0 0 KITCHEN c 3367 17 147 1.000 8.0 OxO VIFx 24.1 160.0 st8 KITCHEN -A c 3367 17 147 1.000 8.0 OxO VIFx 21.4 160.0 st8 LIVINGIDINING h 2394 173 148 1.000 8.0 OxO VIFx 39.4 160.0 st6 LIVING/DIMNG-A h 2394 173 148 1.000 8.0 OxO VIFx 37.5 160.0 st6 PANTRY h 2122 153 74 1.000 6.0 OxO VIFx 19.8 160.0 st8 POWDER RM c 983 0 43 1.000 6.0 0x0 VIFx 53.4 180.0 st7 STORAGEWIC c 1152 33 50 1.000 6.0 0x0 VIFx 37.5 180.0 st9 Un LITY h 1693 122 71 1.000 6.0 0x0 VIFx 36.7 180.0 st9 WC c 1201 12 53 1.000 6.0 Ox0 VIFx 52.0 180.0 st7 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st7 Peak AVF 355 290 1.000 803 9.0 0 x 0 VinlFlx st6 st6 Peak AVF 701 586 1.000 893 12.0 0 x 0 VinlFlx st3 st9 Peak AVF 155 121 1.000 582 7.0 0 x 0 VinlFlx st8 st8 Peak AVF 472 587 1.000 747 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 1173 1173 1.000 840 16.0 0 x 0 VinIFIX Wrightsof m 2020-Jan-2813:26:05 Right -Suite® Uniwfsal 201919.0.08 RSW8101 Page 3 E:1Docmmets%Wnghtscft RVAC\ROAF RESIDENCE.mp Calc=MJ8 Front Door faces: N y Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb2 Ox0 1173 1173 0 0 0 0 Ox 0 VIFx Wr19htro t- 2020-Jan-2813:26:05 $ •••+� �—.•�. RightSuite® Uti�al 201919.0.08 RSW8101 Page 4 E:10ocunnels\Wrightson HUAC1ROAF RESIDENCE.mp Cole =MJB Front Door faces: N